Search criteria
20 vulnerabilities found for MC Works64 by Mitsubishi Electric
CVE-2022-33320 (GCVE-0-2022-33320)
Vulnerability from nvd – Published: 2022-07-20 16:56 – Updated: 2026-01-09 05:16
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.319Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:16:27.798Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33320",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33320",
"datePublished": "2022-07-20T16:56:24",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:16:27.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33319 (GCVE-0-2022-33319)
Vulnerability from nvd – Published: 2022-07-20 16:58 – Updated: 2026-01-09 05:14
VLAI?
Summary
Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
Severity ?
8.2 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.355Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:14:32.690Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33319",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33319",
"datePublished": "2022-07-20T16:58:49",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:14:32.690Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33318 (GCVE-0-2022-33318)
Vulnerability from nvd – Published: 2022-07-20 16:57 – Updated: 2026-01-09 05:12
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
Severity ?
9.8 (Critical)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:12:41.871Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33318",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33318",
"datePublished": "2022-07-20T16:57:38",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:12:41.871Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33317 (GCVE-0-2022-33317)
Vulnerability from nvd – Published: 2022-07-20 16:53 – Updated: 2026-01-09 05:09
VLAI?
Summary
Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
Severity ?
7.8 (High)
CWE
- CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
}
],
"value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-829",
"description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:09:15.556Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33317",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Inclusion of Functionality from Untrusted Control Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33317",
"datePublished": "2022-07-20T16:53:59",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:09:15.556Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33316 (GCVE-0-2022-33316)
Vulnerability from nvd – Published: 2022-07-20 16:51 – Updated: 2026-01-09 05:07
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.142Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:07:12.066Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33316",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33316",
"datePublished": "2022-07-20T16:51:27",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:07:12.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33315 (GCVE-0-2022-33315)
Vulnerability from nvd – Published: 2022-07-20 16:55 – Updated: 2026-01-09 04:58
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:01:20.500Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T04:58:25.913Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33315",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33315",
"datePublished": "2022-07-20T16:55:13",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T04:58:25.913Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-12015 (GCVE-0-2020-12015)
Vulnerability from nvd – Published: 2020-07-16 21:30 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.726Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "version 10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "version 9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:30:43",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12015",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "version 10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "version 9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12015",
"datePublished": "2020-07-16T21:30:43",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.726Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12013 (GCVE-0-2020-12013)
Vulnerability from nvd – Published: 2020-07-16 21:14 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-94 - IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') CWE-94
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
Version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.506Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:14:34",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12013",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "Version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12013",
"datePublished": "2020-07-16T21:14:34",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12007 (GCVE-0-2020-12007)
Vulnerability from nvd – Published: 2020-07-16 21:49 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
Version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.519Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02%2C"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:49:12",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02%2C"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12007",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "Version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02,",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02,"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12007",
"datePublished": "2020-07-16T21:49:12",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.519Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12009 (GCVE-0-2020-12009)
Vulnerability from nvd – Published: 2020-07-16 19:39 – Updated: 2024-09-16 23:00
VLAI?
Summary
A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"datePublic": "2020-06-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T19:39:24",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-06-18T15:00:00.000Z",
"ID": "CVE-2020-12009",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12009",
"datePublished": "2020-07-16T19:39:24.072953Z",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-09-16T23:00:29.508Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-33319 (GCVE-0-2022-33319)
Vulnerability from cvelistv5 – Published: 2022-07-20 16:58 – Updated: 2026-01-09 05:14
VLAI?
Summary
Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
Severity ?
8.2 (High)
CWE
- CWE-125 - Out-of-bounds Read
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.355Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"value": "Out-of-bounds Read vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125 Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:14:32.690Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33319",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Out-of-bounds Read vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to disclose information on memory or cause a Denial of Service (DoS) condition by sending specially crafted packets to the GENESIS64 server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33319",
"datePublished": "2022-07-20T16:58:49",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:14:32.690Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33318 (GCVE-0-2022-33318)
Vulnerability from cvelistv5 – Published: 2022-07-20 16:57 – Updated: 2026-01-09 05:12
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server.
Severity ?
9.8 (Critical)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.263Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS32",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 9.7 and prior"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric GENESIS32 versions 9.7 and prior, Mitsubishi Electric Iconics Digital Solutions GENESIS32 versions 9.7 and prior, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64, ICONICS Suite, GENESIS32, or MC Works64 server."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:12:41.871Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33318",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows a remote unauthenticated attacker to execute an arbitrary malicious code by sending specially crafted packets to the GENESIS64 server."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33318",
"datePublished": "2022-07-20T16:57:38",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:12:41.871Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33320 (GCVE-0-2022-33320)
Vulnerability from cvelistv5 – Published: 2022-07-20 16:56 – Updated: 2026-01-09 05:16
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.319Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:16:27.798Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33320",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a project configuration file including malicious XML codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33320",
"datePublished": "2022-07-20T16:56:24",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:16:27.798Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33315 (GCVE-0-2022-33315)
Vulnerability from cvelistv5 – Published: 2022-07-20 16:55 – Updated: 2026-01-09 04:58
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:01:20.500Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T04:58:25.913Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33315",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33315",
"datePublished": "2022-07-20T16:55:13",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T04:58:25.913Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33317 (GCVE-0-2022-33317)
Vulnerability from cvelistv5 – Published: 2022-07-20 16:53 – Updated: 2026-01-09 05:09
VLAI?
Summary
Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes.
Severity ?
7.8 (High)
CWE
- CWE-829 - Inclusion of Functionality from Untrusted Control Sphere
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.143Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
}
],
"value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-829",
"description": "CWE-829 Inclusion of Functionality from Untrusted Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:09:15.556Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33317",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Inclusion of Functionality from Untrusted Control Sphere vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious script codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Inclusion of Functionality from Untrusted Control Sphere"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33317",
"datePublished": "2022-07-20T16:53:59",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:09:15.556Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2022-33316 (GCVE-0-2022-33316)
Vulnerability from cvelistv5 – Published: 2022-07-20 16:51 – Updated: 2026-01-09 05:07
VLAI?
Summary
Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes.
Severity ?
7.8 (High)
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | GENESIS64 |
Affected:
Versions 10.97 to 10.97.1
|
||||||||||||||||||||||
|
||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T08:09:21.142Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "GENESIS64",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "ICONICS Suite",
"vendor": "Mitsubishi Electric Iconics Digital Solutions",
"versions": [
{
"status": "affected",
"version": "Versions 10.97 to 10.97.1"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Versions 4.04E and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"value": "Deserialization of Untrusted Data vulnerability in Mitsubishi Electric GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions GENESIS64 versions 10.97 to 10.97.1, Mitsubishi Electric ICONICS Suite versions 10.97 to 10.97.1, Mitsubishi Electric Iconics Digital Solutions ICONICS Suite versions 10.97 to 10.97.1, and Mitsubishi Electric MC Works64 versions 4.04E and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T05:07:12.066Z",
"orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"shortName": "Mitsubishi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"tags": [
"government-resource"
],
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
},
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-22-202-04"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.5.0"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "Mitsubishielectric.Psirt@yd.MitsubishiElectric.co.jp",
"ID": "CVE-2022-33316",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ICONICS GENESIS64; Mitsubishi Electric MC Works64",
"version": {
"version_data": [
{
"version_value": "ICONICS GENESIS64 versions 10.97.1 and prior"
},
{
"version_value": "Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data vulnerability in ICONICS GENESIS64 versions 10.97.1 and prior and Mitsubishi Electric MC Works64 versions 4.04E (10.95.210.01) and prior allows an unauthenticated attacker to execute an arbitrary malicious code by leading a user to load a monitoring screen file including malicious XAML codes."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Deserialization of Untrusted Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf",
"refsource": "MISC",
"url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2022-008_en.pdf"
},
{
"name": "https://jvn.jp/vu/JVNVU96480474/index.html",
"refsource": "MISC",
"url": "https://jvn.jp/vu/JVNVU96480474/index.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
"assignerShortName": "Mitsubishi",
"cveId": "CVE-2022-33316",
"datePublished": "2022-07-20T16:51:27",
"dateReserved": "2022-06-14T00:00:00",
"dateUpdated": "2026-01-09T05:07:12.066Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2020-12007 (GCVE-0-2020-12007)
Vulnerability from cvelistv5 – Published: 2020-07-16 21:49 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
Version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.519Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02%2C"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:49:12",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02%2C"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12007",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "Version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted communication packet sent to the affected devices could allow remote code execution and a denial-of-service condition due to a deserialization vulnerability. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02,",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02,"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12007",
"datePublished": "2020-07-16T21:49:12",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.519Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12015 (GCVE-0-2020-12015)
Vulnerability from cvelistv5 – Published: 2020-07-16 21:30 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.726Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "version 10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "version 9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:30:43",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12015",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "version 10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "version 9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted communication packet sent to the affected systems could cause a denial-of-service condition due to improper deserialization. This issue affects: Mitsubishi Electric MC Works64 version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server version 10.96 and prior; ICONICS GenBroker32 version 9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-03"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://www.us-cert.gov/ics/advisories/icsa-20-170-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12015",
"datePublished": "2020-07-16T21:30:43",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.726Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12013 (GCVE-0-2020-12013)
Vulnerability from cvelistv5 – Published: 2020-07-16 21:14 – Updated: 2024-08-04 11:48
VLAI?
Summary
A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-94 - IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') CWE-94
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
Version 4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.506Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-94",
"description": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T21:14:34",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2020-12013",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "Version 4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted WCF client that interfaces to the may allow the execution of certain arbitrary SQL commands remotely. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12013",
"datePublished": "2020-07-16T21:14:34",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-08-04T11:48:57.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-12009 (GCVE-0-2020-12009)
Vulnerability from cvelistv5 – Published: 2020-07-16 19:39 – Updated: 2024-09-16 23:00
VLAI?
Summary
A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior.
Severity ?
No CVSS data available.
CWE
- CWE-502 - DESERIALIZATION OF UNTRUSTED DATA CWE-502
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Mitsubishi Electric | MC Works64 |
Affected:
4.02C (10.95.208.31) and earlier
Affected: all versions |
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T11:48:57.050Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "MC Works64",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "4.02C (10.95.208.31) and earlier"
},
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "MC Works32",
"vendor": "Mitsubishi Electric",
"versions": [
{
"status": "affected",
"version": "Version 3.00A (9.50.255.02)"
}
]
},
{
"product": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v10.96 and prior"
}
]
},
{
"product": "GenBroker32",
"vendor": "ICONICS",
"versions": [
{
"status": "affected",
"version": "v9.5 and prior"
}
]
}
],
"datePublic": "2020-06-18T00:00:00",
"descriptions": [
{
"lang": "en",
"value": "A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "DESERIALIZATION OF UNTRUSTED DATA CWE-502",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-07-16T19:39:24",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2020-06-18T15:00:00.000Z",
"ID": "CVE-2020-12009",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "MC Works64",
"version": {
"version_data": [
{
"version_value": "4.02C (10.95.208.31) and earlier"
},
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "MC Works32",
"version": {
"version_data": [
{
"version_value": "Version 3.00A (9.50.255.02)"
}
]
}
}
]
},
"vendor_name": "Mitsubishi Electric"
},
{
"product": {
"product_data": [
{
"product_name": "GenBroker64, Platform Services, Workbench, FrameWorX Server",
"version": {
"version_data": [
{
"version_value": "v10.96 and prior"
}
]
}
},
{
"product_name": "GenBroker32",
"version": {
"version_data": [
{
"version_value": "v9.5 and prior"
}
]
}
}
]
},
"vendor_name": "ICONICS"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A specially crafted communication packet sent to the affected device could cause a denial-of-service condition due to a deserialization vulnerability. This affects: Mitsubishi Electric MC Works64 Version 4.02C (10.95.208.31) and earlier, all versions; Mitsubishi Electric MC Works32 Version 3.00A (9.50.255.02); ICONICS GenBroker64, Platform Services, Workbench, FrameWorX Server v10.96 and prior; ICONICS GenBroker32 v9.5 and prior."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "DESERIALIZATION OF UNTRUSTED DATA CWE-502"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-02"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-20-170-03"
}
]
},
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2020-12009",
"datePublished": "2020-07-16T19:39:24.072953Z",
"dateReserved": "2020-04-21T00:00:00",
"dateUpdated": "2024-09-16T23:00:29.508Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",