Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for LenovoSystemUpdatePlugin for Lenovo System Interface Foundation by Lenovo

    CVE-2020-8318 (GCVE-0-2020-8318)

    Vulnerability from nvd – Published: 2020-04-14 21:05 – Updated: 2024-09-16 22:56
    VLAI
    Summary
    A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges.
    CWE
    • Privilege escalation
    Assigner
    References
    Impacted products
    Date Public
    2020-04-14 00:00
    Credits
    Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:56:28.350Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
              "vendor": "Lenovo",
              "versions": [
                {
                  "lessThan": "2.0.0.92",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
            }
          ],
          "datePublic": "2020-04-14T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Privilege escalation",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-14T21:05:19.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
            }
          ],
          "source": {
            "advisory": "LEN-30401",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
              "ID": "CVE-2020-8318",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2.0.0.92"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Privilege escalation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
              }
            ],
            "source": {
              "advisory": "LEN-30401",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2020-8318",
        "datePublished": "2020-04-14T21:05:20.039Z",
        "dateReserved": "2020-01-28T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:56:31.781Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2020-8318 (GCVE-0-2020-8318)

    Vulnerability from cvelistv5 – Published: 2020-04-14 21:05 – Updated: 2024-09-16 22:56
    VLAI
    Summary
    A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges.
    CWE
    • Privilege escalation
    Assigner
    References
    Impacted products
    Date Public
    2020-04-14 00:00
    Credits
    Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T09:56:28.350Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
              "vendor": "Lenovo",
              "versions": [
                {
                  "lessThan": "2.0.0.92",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
            }
          ],
          "datePublic": "2020-04-14T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Privilege escalation",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-04-14T21:05:19.000Z",
            "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
            "shortName": "lenovo"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
            }
          ],
          "source": {
            "advisory": "LEN-30401",
            "discovery": "UNKNOWN"
          },
          "x_generator": {
            "engine": "Vulnogram 0.0.9"
          },
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "psirt@lenovo.com",
              "DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
              "ID": "CVE-2020-8318",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "LenovoSystemUpdatePlugin for Lenovo System Interface Foundation",
                          "version": {
                            "version_data": [
                              {
                                "version_affected": "\u003c",
                                "version_value": "2.0.0.92"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "Lenovo"
                  }
                ]
              }
            },
            "credit": [
              {
                "lang": "eng",
                "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
              }
            ],
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "A privilege escalation vulnerability was reported in the LenovoSystemUpdatePlugin for Lenovo System Interface Foundation prior to version that could allow an authenticated user to execute code with elevated privileges."
                }
              ]
            },
            "generator": {
              "engine": "Vulnogram 0.0.9"
            },
            "impact": {
              "cvss": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Privilege escalation"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
                  "refsource": "MISC",
                  "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
                }
              ]
            },
            "solution": [
              {
                "lang": "en",
                "value": "Update LenovoSystemUpdatePlugin for Lenovo System Interface Foundation to version 2.0.0.92.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
              }
            ],
            "source": {
              "advisory": "LEN-30401",
              "discovery": "UNKNOWN"
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "assignerShortName": "lenovo",
        "cveId": "CVE-2020-8318",
        "datePublished": "2020-04-14T21:05:20.039Z",
        "dateReserved": "2020-01-28T00:00:00.000Z",
        "dateUpdated": "2024-09-16T22:56:31.781Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }