Search criteria

6 vulnerabilities found for Lenovo System Interface Foundation by Lenovo

CVE-2020-8319 (GCVE-0-2020-8319)

Vulnerability from nvd – Published: 2020-04-14 21:05 – Updated: 2024-09-16 17:27
VLAI?
Summary
A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges.
CWE
  • Privilege escalation
Assigner
References
Impacted products
Vendor Product Version
Lenovo Lenovo System Interface Foundation Affected: unspecified , < 1.1.19.3 (custom)
Create a notification for this product.
Credits
Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:56:28.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Lenovo System Interface Foundation",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.1.19.3",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
        }
      ],
      "datePublic": "2020-04-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Privilege escalation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-14T21:05:20",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update Lenovo System Interface Foundation to version 1.1.19.3.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
        }
      ],
      "source": {
        "advisory": "LEN-30401",
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
          "ID": "CVE-2020-8319",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Lenovo System Interface Foundation",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "1.1.19.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Privilege escalation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update Lenovo System Interface Foundation to version 1.1.19.3.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
          }
        ],
        "source": {
          "advisory": "LEN-30401",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2020-8319",
    "datePublished": "2020-04-14T21:05:20.446842Z",
    "dateReserved": "2020-01-28T00:00:00",
    "dateUpdated": "2024-09-16T17:27:40.189Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6189 (GCVE-0-2019-6189)

Vulnerability from nvd – Published: 2019-11-20 01:31 – Updated: 2024-09-16 20:16
VLAI?
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL.
Severity ?
No CVSS data available.
CWE
  • local privilege escalation
Assigner
References
Impacted products
Vendor Product Version
Lenovo Lenovo System Interface Foundation Unknown: unspecified , ≤ 1.1.18.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:24.514Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/solutions/LEN-29198"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Lenovo System Interface Foundation",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThanOrEqual": "1.1.18.3",
              "status": "unknown",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-11-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "local privilege escalation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-20T01:31:14",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/solutions/LEN-29198"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
        }
      ],
      "source": {
        "advisory": "LEN-29198",
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
          "ID": "CVE-2019-6189",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Lenovo System Interface Foundation",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "?\u003c=",
                            "version_value": "1.1.18.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "local privilege escalation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/solutions/LEN-29198",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/solutions/LEN-29198"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
          }
        ],
        "source": {
          "advisory": "LEN-29198",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2019-6189",
    "datePublished": "2019-11-20T01:31:14.196742Z",
    "dateReserved": "2019-01-11T00:00:00",
    "dateUpdated": "2024-09-16T20:16:34.199Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6186 (GCVE-0-2019-6186)

Vulnerability from nvd – Published: 2019-11-20 01:31 – Updated: 2024-09-16 17:23
VLAI?
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user.
Severity ?
No CVSS data available.
CWE
  • local privilege escalation
Assigner
References
Impacted products
Vendor Product Version
Lenovo Lenovo System Interface Foundation Unknown: unspecified , ≤ 1.1.18.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:23.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/solutions/LEN-29198"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Lenovo System Interface Foundation",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThanOrEqual": "1.1.18.3",
              "status": "unknown",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-11-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "local privilege escalation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-20T01:31:13",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/solutions/LEN-29198"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
        }
      ],
      "source": {
        "advisory": "LEN-29198",
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
          "ID": "CVE-2019-6186",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Lenovo System Interface Foundation",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "?\u003c=",
                            "version_value": "1.1.18.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "local privilege escalation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/solutions/LEN-29198",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/solutions/LEN-29198"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
          }
        ],
        "source": {
          "advisory": "LEN-29198",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2019-6186",
    "datePublished": "2019-11-20T01:31:13.404005Z",
    "dateReserved": "2019-01-11T00:00:00",
    "dateUpdated": "2024-09-16T17:23:01.398Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-8319 (GCVE-0-2020-8319)

Vulnerability from cvelistv5 – Published: 2020-04-14 21:05 – Updated: 2024-09-16 17:27
VLAI?
Summary
A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges.
CWE
  • Privilege escalation
Assigner
References
Impacted products
Vendor Product Version
Lenovo Lenovo System Interface Foundation Affected: unspecified , < 1.1.19.3 (custom)
Create a notification for this product.
Credits
Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:56:28.339Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Lenovo System Interface Foundation",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThan": "1.1.19.3",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
        }
      ],
      "datePublic": "2020-04-14T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Privilege escalation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-14T21:05:20",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update Lenovo System Interface Foundation to version 1.1.19.3.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
        }
      ],
      "source": {
        "advisory": "LEN-30401",
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2020-04-14T21:00:00.000Z",
          "ID": "CVE-2020-8319",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Lenovo System Interface Foundation",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "1.1.19.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Lenovo thanks Ceri Coburn at Pen Test Partners for reporting this issue."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A privilege escalation vulnerability was reported in Lenovo System Interface Foundation prior to version 1.1.19.3 that could allow an authenticated user to execute code with elevated privileges."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Privilege escalation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/us/en/product_security/LEN-30401",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/us/en/product_security/LEN-30401"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update Lenovo System Interface Foundation to version 1.1.19.3.  To update Vantage and its Lenovo System Interface Foundation component, follow these steps: 1) Update Lenovo Vantage to version 10.2003.10.0 from the Microsoft Store. 2) Re-launch Lenovo Vantage to complete the update."
          }
        ],
        "source": {
          "advisory": "LEN-30401",
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2020-8319",
    "datePublished": "2020-04-14T21:05:20.446842Z",
    "dateReserved": "2020-01-28T00:00:00",
    "dateUpdated": "2024-09-16T17:27:40.189Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6189 (GCVE-0-2019-6189)

Vulnerability from cvelistv5 – Published: 2019-11-20 01:31 – Updated: 2024-09-16 20:16
VLAI?
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL.
Severity ?
No CVSS data available.
CWE
  • local privilege escalation
Assigner
References
Impacted products
Vendor Product Version
Lenovo Lenovo System Interface Foundation Unknown: unspecified , ≤ 1.1.18.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:24.514Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/solutions/LEN-29198"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Lenovo System Interface Foundation",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThanOrEqual": "1.1.18.3",
              "status": "unknown",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-11-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "local privilege escalation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-20T01:31:14",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/solutions/LEN-29198"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
        }
      ],
      "source": {
        "advisory": "LEN-29198",
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
          "ID": "CVE-2019-6189",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Lenovo System Interface Foundation",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "?\u003c=",
                            "version_value": "1.1.18.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an administrative user to load an unsigned DLL."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "local privilege escalation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/solutions/LEN-29198",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/solutions/LEN-29198"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
          }
        ],
        "source": {
          "advisory": "LEN-29198",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2019-6189",
    "datePublished": "2019-11-20T01:31:14.196742Z",
    "dateReserved": "2019-01-11T00:00:00",
    "dateUpdated": "2024-09-16T20:16:34.199Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6186 (GCVE-0-2019-6186)

Vulnerability from cvelistv5 – Published: 2019-11-20 01:31 – Updated: 2024-09-16 17:23
VLAI?
Summary
A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user.
Severity ?
No CVSS data available.
CWE
  • local privilege escalation
Assigner
References
Impacted products
Vendor Product Version
Lenovo Lenovo System Interface Foundation Unknown: unspecified , ≤ 1.1.18.3 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:16:23.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://support.lenovo.com/solutions/LEN-29198"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Lenovo System Interface Foundation",
          "vendor": "Lenovo",
          "versions": [
            {
              "lessThanOrEqual": "1.1.18.3",
              "status": "unknown",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-11-19T00:00:00",
      "descriptions": [
        {
          "lang": "en",
          "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "local privilege escalation",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-11-20T01:31:13",
        "orgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
        "shortName": "lenovo"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://support.lenovo.com/solutions/LEN-29198"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
        }
      ],
      "source": {
        "advisory": "LEN-29198",
        "discovery": "EXTERNAL"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.8"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@lenovo.com",
          "DATE_PUBLIC": "2019-11-19T17:00:00.000Z",
          "ID": "CVE-2019-6186",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Lenovo System Interface Foundation",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "?\u003c=",
                            "version_value": "1.1.18.3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Lenovo"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A potential vulnerability was reported in Lenovo System Interface Foundation versions before v1.1.18.3 that could allow an authenticated user to execute code as another user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.8"
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "local privilege escalation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://support.lenovo.com/solutions/LEN-29198",
              "refsource": "MISC",
              "url": "https://support.lenovo.com/solutions/LEN-29198"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update Lenovo System Interface Foundation to version 1.1.18.3 (or higher)"
          }
        ],
        "source": {
          "advisory": "LEN-29198",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "da227ddf-6e25-4b41-b023-0f976dcaca4b",
    "assignerShortName": "lenovo",
    "cveId": "CVE-2019-6186",
    "datePublished": "2019-11-20T01:31:13.404005Z",
    "dateReserved": "2019-01-11T00:00:00",
    "dateUpdated": "2024-09-16T17:23:01.398Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}