    CVE-2025-31704 (GCVE-0-2025-31704)

    Vulnerability from nvd – Published: 2026-10-30 10:25 – Updated: 2026-10-30 15:07
    VLAI
    Title
    Dahua Intelligent Connection Center command injection
    Summary
    A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-30 14:56 UTC
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    dahua CNA under the mitre root
    CNA scorecard – unranked: 4 records in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    Dahua Intelligent Connection Center Affected: V1.000.0000000.1 , ≤ 1.000.0000005.0 (custom)
    Affected: V5.000.0000000.6 , < V5.000.0000000.15 (custom)
    Create a notification for this product.
    Date Public
    2026-10-30 08:46
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-31704",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-30T14:56:03.867102Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T15:07:34.049Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intelligent Connection Center",
              "vendor": "Dahua",
              "versions": [
                {
                  "lessThanOrEqual": "1.000.0000005.0",
                  "status": "affected",
                  "version": "V1.000.0000000.1",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V5.000.0000000.15",
                  "status": "affected",
                  "version": "V5.000.0000000.6",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2026-10-30T08:46:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution."
                }
              ],
              "value": "A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-116",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-116 Excavation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-30T10:25:46.561Z",
            "orgId": "79ee569e-7d1e-4364-98f0-3a18e2a739ad",
            "shortName": "dahua"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2025-00420"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Dahua Intelligent Connection Center command injection",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "79ee569e-7d1e-4364-98f0-3a18e2a739ad",
        "assignerShortName": "dahua",
        "cveId": "CVE-2025-31704",
        "datePublished": "2026-10-30T10:25:46.561Z",
        "dateReserved": "2025-04-01T05:57:11.783Z",
        "dateUpdated": "2026-10-30T15:07:34.049Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2025-31704 (GCVE-0-2025-31704)

    Vulnerability from cvelistv5 – Published: 2026-10-30 10:25 – Updated: 2026-10-30 15:07
    VLAI
    Title
    Dahua Intelligent Connection Center command injection
    Summary
    A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-10-30 14:56 UTC
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS command injection')
    Assigner
    dahua CNA under the mitre root
    CNA scorecard – unranked: 4 records in the last 180 days, 10 needed details
    References
    Impacted products
    Vendor Product Version
    Dahua Intelligent Connection Center Affected: V1.000.0000000.1 , ≤ 1.000.0000005.0 (custom)
    Affected: V5.000.0000000.6 , < V5.000.0000000.15 (custom)
    Create a notification for this product.
    Date Public
    2026-10-30 08:46
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-31704",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-10-30T14:56:03.867102Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-10-30T15:07:34.049Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "Intelligent Connection Center",
              "vendor": "Dahua",
              "versions": [
                {
                  "lessThanOrEqual": "1.000.0000005.0",
                  "status": "affected",
                  "version": "V1.000.0000000.1",
                  "versionType": "custom"
                },
                {
                  "lessThan": "V5.000.0000000.15",
                  "status": "affected",
                  "version": "V5.000.0000000.6",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2026-10-30T08:46:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution."
                }
              ],
              "value": "A vulnerability has been found in the Dahua Intelligent Connection Center. A remote attacker could send a specially crafted request to the affected system, allowing the attacker to execute arbitrary commands, resulting in remote code execution."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-116",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-116 Excavation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "CWE-78 Improper neutralization of special elements used in an OS command (\u0027OS command injection\u0027)",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-10-30T10:25:46.561Z",
            "orgId": "79ee569e-7d1e-4364-98f0-3a18e2a739ad",
            "shortName": "dahua"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cnvd.org.cn/flaw/show/CNVD-2025-00420"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Dahua Intelligent Connection Center command injection",
          "x_generator": {
            "engine": "Vulnogram 1.0.5"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "79ee569e-7d1e-4364-98f0-3a18e2a739ad",
        "assignerShortName": "dahua",
        "cveId": "CVE-2025-31704",
        "datePublished": "2026-10-30T10:25:46.561Z",
        "dateReserved": "2025-04-01T05:57:11.783Z",
        "dateUpdated": "2026-10-30T15:07:34.049Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }