Search

Find a vulnerability

Search criteria

    14 vulnerabilities found for HG10 by Tenda

    CVE-2026-11553 (GCVE-0-2026-11553)

    Vulnerability from nvd – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
    VLAI
    Title
    Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 18:49 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11553",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T18:49:04.954919Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T18:49:14.135Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zhihua xie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T17:15:11.855Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369163"
            },
            {
              "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369163/cti"
            },
            {
              "name": "CVE-2026-11553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11553"
            },
            {
              "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836778"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T07:48:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11553",
        "datePublished": "2026-06-08T17:15:11.855Z",
        "dateReserved": "2026-06-08T05:43:31.214Z",
        "dateUpdated": "2026-06-08T18:49:14.135Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11499 (GCVE-0-2026-11499)

    Vulnerability from nvd – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
    VLAI
    Title
    Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
    Summary
    A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:55 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369119 vdb-entrytechnical-description
    https://vuldb.com/vuln/369119/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
    https://vuldb.com/submit/834888 third-party-advisory
    https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:55:19.613788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:55:29.374Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T07:00:23.672Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369119"
            },
            {
              "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369119/cti"
            },
            {
              "name": "CVE-2026-11499 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11499"
            },
            {
              "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834888"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:28:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11499",
        "datePublished": "2026-06-08T07:00:23.672Z",
        "dateReserved": "2026-06-07T13:23:38.138Z",
        "dateUpdated": "2026-06-08T12:55:29.374Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11498 (GCVE-0-2026-11498)

    Vulnerability from nvd – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
    VLAI
    Title
    Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:47 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369118 vdb-entrytechnical-description
    https://vuldb.com/vuln/369118/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
    https://vuldb.com/submit/834887 third-party-advisory
    https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:47:31.920390Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:24.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T06:45:21.289Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369118"
            },
            {
              "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369118/cti"
            },
            {
              "name": "CVE-2026-11498 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11498"
            },
            {
              "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834887"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:27:15.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11498",
        "datePublished": "2026-06-08T06:45:21.289Z",
        "dateReserved": "2026-06-07T13:22:12.336Z",
        "dateUpdated": "2026-06-08T16:22:24.244Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-6988 (GCVE-0-2026-6988)

    Vulnerability from nvd – Published: 2026-04-25 17:00 – Updated: 2026-04-27 14:07
    VLAI
    Title
    Tenda HG10 Boa Service formRouting formRoute buffer overflow
    Summary
    A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-04-27 14:07 UTC
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6988",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-27T14:07:39.860516Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-27T14:07:53.405Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Service"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xuanyu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-25T17:00:24.221Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-359540 | Tenda HG10 Boa Service formRouting formRoute buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/359540"
            },
            {
              "name": "VDB-359540 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/359540/cti"
            },
            {
              "name": "Submit #796427 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/796427"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xyh4ck/iot_poc/blob/main/Tenda/HG10/01_Buffer_Overflow_nextHop/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-24T21:28:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Service formRouting formRoute buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6988",
        "datePublished": "2026-04-25T17:00:24.221Z",
        "dateReserved": "2026-04-24T19:23:13.271Z",
        "dateUpdated": "2026-04-27T14:07:53.405Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1690 (GCVE-0-2026-1690)

    Vulnerability from nvd – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:10
    VLAI
    Title
    Tenda HG10 formSysCmd system command injection
    Summary
    A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-30 16:53 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: US_HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1690",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-30T16:53:41.108984Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-30T16:54:08.213Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "US_HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abcd1234 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.8,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:10:09.575Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-343484 | Tenda HG10 formSysCmd system command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.343484"
            },
            {
              "name": "VDB-343484 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.343484"
            },
            {
              "name": "Submit #741425 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.741425"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-30T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-31T10:40:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 formSysCmd system command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1690",
        "datePublished": "2026-01-30T16:32:11.826Z",
        "dateReserved": "2026-01-30T07:57:40.795Z",
        "dateUpdated": "2026-02-23T09:10:09.575Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1689 (GCVE-0-2026-1689)

    Vulnerability from nvd – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:09
    VLAI
    Title
    Tenda HG10 Login formLogin checkUserFromLanOrWan command injection
    Summary
    A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-30 16:51 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: US_HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1689",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-30T16:51:23.837327Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-30T16:51:49.332Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Login Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "US_HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abcd1234 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:09:54.959Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-343483 | Tenda HG10 Login formLogin checkUserFromLanOrWan command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.343483"
            },
            {
              "name": "VDB-343483 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.343483"
            },
            {
              "name": "Submit #741411 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.741411"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-30T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-31T10:40:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Login formLogin checkUserFromLanOrWan command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1689",
        "datePublished": "2026-01-30T16:32:08.118Z",
        "dateReserved": "2026-01-30T07:56:21.633Z",
        "dateUpdated": "2026-02-23T09:09:54.959Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1687 (GCVE-0-2026-1687)

    Vulnerability from nvd – Published: 2026-01-30 16:02 – Updated: 2026-02-23 09:09
    VLAI
    Title
    Tenda HG10 Boa Webserver formSamba command injection
    Summary
    A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-30 16:26 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: US_HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1687",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-30T16:26:20.214560Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-30T16:26:27.737Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Webserver"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "US_HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abcd1234 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:09:26.903Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-343481 | Tenda HG10 Boa Webserver formSamba command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.343481"
            },
            {
              "name": "VDB-343481 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.343481"
            },
            {
              "name": "Submit #741281 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.741281"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-30T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-31T10:40:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Webserver formSamba command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1687",
        "datePublished": "2026-01-30T16:02:09.067Z",
        "dateReserved": "2026-01-30T07:51:50.019Z",
        "dateUpdated": "2026-02-23T09:09:26.903Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11553 (GCVE-0-2026-11553)

    Vulnerability from cvelistv5 – Published: 2026-06-08 17:15 – Updated: 2026-06-08 18:49
    VLAI
    Title
    Tenda HG7HG9/HG10 formPPPEdit stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 18:49 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11553",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T18:49:04.954919Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T18:49:14.135Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "zhihua xie (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formPPPEdit of the file /boaform/formPPPEdit. The manipulation of the argument encodename results in stack-based buffer overflow. The attack can be launched remotely. The exploit has been made public and could be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T17:15:11.855Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369163 | Tenda HG7HG9/HG10 formPPPEdit stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369163"
            },
            {
              "name": "VDB-369163 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369163/cti"
            },
            {
              "name": "CVE-2026-11553 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11553"
            },
            {
              "name": "Submit #836778 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/836778"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow.git"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xiezhihua-1127/Tenda-Stack-Overflow/blob/main/report.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-08T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-08T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-08T07:48:34.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formPPPEdit stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11553",
        "datePublished": "2026-06-08T17:15:11.855Z",
        "dateReserved": "2026-06-08T05:43:31.214Z",
        "dateUpdated": "2026-06-08T18:49:14.135Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11499 (GCVE-0-2026-11499)

    Vulnerability from cvelistv5 – Published: 2026-06-08 07:00 – Updated: 2026-06-08 12:55
    VLAI
    Title
    Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow
    Summary
    A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:55 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369119 vdb-entrytechnical-description
    https://vuldb.com/vuln/369119/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11499 third-party-advisory
    https://vuldb.com/submit/834888 third-party-advisory
    https://github.com/ssaaaa1234/Tenda-HG10-formDOMA… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11499",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:55:19.613788Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T12:55:29.374Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was determined in Tenda HG7HG9 and HG10 300001138_en_xpon. This affects the function formDOMAINBLK of the file /boaform/formDOMAINBLK. Executing a manipulation of the argument blkDomain can lead to stack-based buffer overflow. The attack may be performed from remote."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 9.3,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 10,
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T07:00:23.672Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369119 | Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369119"
            },
            {
              "name": "VDB-369119 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369119/cti"
            },
            {
              "name": "CVE-2026-11499 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11499"
            },
            {
              "name": "Submit #834888 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834888"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/Tenda-HG10-formDOMAINBLK-stack-overflow-2"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:28:41.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 formDOMAINBLK stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11499",
        "datePublished": "2026-06-08T07:00:23.672Z",
        "dateReserved": "2026-06-07T13:23:38.138Z",
        "dateUpdated": "2026-06-08T12:55:29.374Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-11498 (GCVE-0-2026-11498)

    Vulnerability from cvelistv5 – Published: 2026-06-08 06:45 – Updated: 2026-06-08 16:22
    VLAI
    Title
    Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow
    Summary
    A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-06-08 12:47 UTC
    CWE
    Assigner
    References
    URL Tags
    https://vuldb.com/vuln/369118 vdb-entrytechnical-description
    https://vuldb.com/vuln/369118/cti signaturepermissions-required
    https://vuldb.com/cve/CVE-2026-11498 third-party-advisory
    https://vuldb.com/submit/834887 third-party-advisory
    https://github.com/ssaaaa1234/tenda-hg10-voip-oth… broken-link
    https://www.tenda.com.cn/ product
    Impacted products
    Vendor Product Version
    Tenda HG7HG9 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Tenda HG10 Affected: 300001138_en_xpon
        cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-11498",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-06-08T12:47:31.920390Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-06-08T16:22:24.244Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg7hg9:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG7HG9",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            },
            {
              "cpes": [
                "cpe:2.3:h:tenda:hg10:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Web Management Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "moist (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was found in Tenda HG7HG9 and HG10 300001138_en_xpon. Affected by this issue is the function asp_voip_OtherSet of the file /boaform/voip_other_set of the component Web Management Interface. Performing a manipulation of the argument funckey_transfer results in stack-based buffer overflow. The attack is possible to be carried out remotely."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:X/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:ND/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-121",
                  "description": "Stack-based Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-06-08T06:45:21.289Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-369118 | Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/369118"
            },
            {
              "name": "VDB-369118 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/369118/cti"
            },
            {
              "name": "CVE-2026-11498 | CVE Analysis and Report",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/cve/CVE-2026-11498"
            },
            {
              "name": "Submit #834887 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon stack-based buffer overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/834887"
            },
            {
              "tags": [
                "broken-link"
              ],
              "url": "https://github.com/ssaaaa1234/tenda-hg10-voip-other-set-stack-overflow"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-06-07T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-06-07T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-06-07T15:27:15.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG7HG9/HG10 Web Management voip_other_set asp_voip_OtherSet stack-based overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-11498",
        "datePublished": "2026-06-08T06:45:21.289Z",
        "dateReserved": "2026-06-07T13:22:12.336Z",
        "dateUpdated": "2026-06-08T16:22:24.244Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-6988 (GCVE-0-2026-6988)

    Vulnerability from cvelistv5 – Published: 2026-04-25 17:00 – Updated: 2026-04-27 14:07
    VLAI
    Title
    Tenda HG10 Boa Service formRouting formRoute buffer overflow
    Summary
    A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-04-27 14:07 UTC
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-6988",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-04-27T14:07:39.860516Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-04-27T14:07:53.405Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Service"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "xuanyu (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon. This issue affects the function formRoute of the file /boaform/formRouting of the component Boa Service. This manipulation of the argument nextHop causes buffer overflow. It is possible to initiate the attack remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 9,
                "vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "Buffer Overflow",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-119",
                  "description": "Memory Corruption",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-04-25T17:00:24.221Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-359540 | Tenda HG10 Boa Service formRouting formRoute buffer overflow",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/vuln/359540"
            },
            {
              "name": "VDB-359540 | CTI Indicators (IOB, IOC, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/vuln/359540/cti"
            },
            {
              "name": "Submit #796427 | Tenda HG10 HG7_HG9_HG10re_300001138_en_xpon Buffer Overflow",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/submit/796427"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/xyh4ck/iot_poc/blob/main/Tenda/HG10/01_Buffer_Overflow_nextHop/README.md"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-04-24T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-04-24T02:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-04-24T21:28:18.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Service formRouting formRoute buffer overflow"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-6988",
        "datePublished": "2026-04-25T17:00:24.221Z",
        "dateReserved": "2026-04-24T19:23:13.271Z",
        "dateUpdated": "2026-04-27T14:07:53.405Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1690 (GCVE-0-2026-1690)

    Vulnerability from cvelistv5 – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:10
    VLAI
    Title
    Tenda HG10 formSysCmd system command injection
    Summary
    A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used.
    SSVC
    Exploitation: poc Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-30 16:53 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: US_HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1690",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-30T16:53:41.108984Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-30T16:54:08.213Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "US_HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abcd1234 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A flaw has been found in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. This affects the function system of the file /boaform/formSysCmd. This manipulation of the argument sysCmd causes command injection. The attack may be initiated remotely. The exploit has been published and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 4.7,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5.8,
                "vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:10:09.575Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-343484 | Tenda HG10 formSysCmd system command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.343484"
            },
            {
              "name": "VDB-343484 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.343484"
            },
            {
              "name": "Submit #741425 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.741425"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSysCmd-sysCmd-command.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-30T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-31T10:40:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 formSysCmd system command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1690",
        "datePublished": "2026-01-30T16:32:11.826Z",
        "dateReserved": "2026-01-30T07:57:40.795Z",
        "dateUpdated": "2026-02-23T09:10:09.575Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1689 (GCVE-0-2026-1689)

    Vulnerability from cvelistv5 – Published: 2026-01-30 16:32 – Updated: 2026-02-23 09:09
    VLAI
    Title
    Tenda HG10 Login formLogin checkUserFromLanOrWan command injection
    Summary
    A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-30 16:51 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: US_HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1689",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-30T16:51:23.837327Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-30T16:51:49.332Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Login Interface"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "US_HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abcd1234 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability was detected in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. The impacted element is the function checkUserFromLanOrWan of the file /boaform/admin/formLogin of the component Login Interface. The manipulation of the argument Host results in command injection. The attack can be launched remotely. The exploit is now public and may be used."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:09:54.959Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-343483 | Tenda HG10 Login formLogin checkUserFromLanOrWan command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.343483"
            },
            {
              "name": "VDB-343483 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.343483"
            },
            {
              "name": "Submit #741411 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.741411"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formLogin-Host-command.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-30T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-31T10:40:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Login formLogin checkUserFromLanOrWan command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1689",
        "datePublished": "2026-01-30T16:32:08.118Z",
        "dateReserved": "2026-01-30T07:56:21.633Z",
        "dateUpdated": "2026-02-23T09:09:54.959Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-1687 (GCVE-0-2026-1687)

    Vulnerability from cvelistv5 – Published: 2026-01-30 16:02 – Updated: 2026-02-23 09:09
    VLAI
    Title
    Tenda HG10 Boa Webserver formSamba command injection
    Summary
    A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks.
    SSVC
    Exploitation: poc Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-01-30 16:26 UTC
    CWE
    Assigner
    Impacted products
    Vendor Product Version
    Tenda HG10 Affected: US_HG7_HG9_HG10re_300001138_en_xpon
        cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-1687",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-30T16:26:20.214560Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-30T16:26:27.737Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "cpes": [
                "cpe:2.3:o:tenda:hg10_firmware:*:*:*:*:*:*:*:*"
              ],
              "modules": [
                "Boa Webserver"
              ],
              "product": "HG10",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "US_HG7_HG9_HG10re_300001138_en_xpon"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "Abcd1234 (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A weakness has been identified in Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon. Impacted is an unknown function of the file /boaform/formSamba of the component Boa Webserver. Executing a manipulation of the argument serverString can lead to command injection. It is possible to launch the attack remotely. The exploit has been made available to the public and could be used for attacks."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:P",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 7.3,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L/E:P/RL:X/RC:R",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 7.5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P/E:POC/RL:ND/RC:UR",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-77",
                  "description": "Command Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-74",
                  "description": "Injection",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-02-23T09:09:26.903Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-343481 | Tenda HG10 Boa Webserver formSamba command injection",
              "tags": [
                "vdb-entry",
                "technical-description"
              ],
              "url": "https://vuldb.com/?id.343481"
            },
            {
              "name": "VDB-343481 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.343481"
            },
            {
              "name": "Submit #741281 | Tenda HG10 US_HG7_HG9_HG10re_300001138_en_xpon Command Injection",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.741281"
            },
            {
              "tags": [
                "related"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/SunnyYANGyaya/cuicuishark-sheep-fishIOT/blob/main/Tenda/HG10/formSamba-serverString-command.md#poc"
            },
            {
              "tags": [
                "product"
              ],
              "url": "https://www.tenda.com.cn/"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2026-01-30T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2026-01-30T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2026-01-31T10:40:45.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Tenda HG10 Boa Webserver formSamba command injection"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2026-1687",
        "datePublished": "2026-01-30T16:02:09.067Z",
        "dateReserved": "2026-01-30T07:51:50.019Z",
        "dateUpdated": "2026-02-23T09:09:26.903Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }