Search
Find a vulnerability
Search criteria
4 vulnerabilities found for EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) by Schneider Electric
CVE-2023-22611 (GCVE-0-2023-22611)
Vulnerability from nvd – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
VLAI
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Information Exposure
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) |
Affected:
All , < October 2022
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.470Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22611",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:54:59.647770Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:52.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "October 2022",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-22611",
"datePublished": "2023-01-31T00:00:00.000Z",
"dateReserved": "2023-01-04T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:52.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22610 (GCVE-0-2023-22610)
Vulnerability from nvd – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
VLAI
Summary
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of
Service against the Geo SCADA server when specific messages are sent to the server over the
database server TCP port.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) |
Affected:
All , < October 2022
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.385Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22610",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:55:02.779459Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:58.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "October 2022",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\n\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\u003c/p\u003e"
}
],
"value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-14T07:17:44.658Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-22610",
"datePublished": "2023-01-31T00:00:00.000Z",
"dateReserved": "2023-01-04T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:58.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22610 (GCVE-0-2023-22610)
Vulnerability from cvelistv5 – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
VLAI
Summary
A CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of
Service against the Geo SCADA server when specific messages are sent to the server over the
database server TCP port.
Severity
9.1 (Critical)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-863 - Incorrect Authorization
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) |
Affected:
All , < October 2022
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.385Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22610",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:55:02.779459Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:58.944Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "October 2022",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\n\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\u003c/p\u003e"
}
],
"value": "\nA CWE-863: Incorrect Authorization vulnerability exists that could cause Denial of\nService against the Geo SCADA server when specific messages are sent to the server over the\ndatabase server TCP port. \n\n\n\n"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-863",
"description": "CWE-863 Incorrect Authorization",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-14T07:17:44.658Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-22610",
"datePublished": "2023-01-31T00:00:00.000Z",
"dateReserved": "2023-01-04T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:58.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-22611 (GCVE-0-2023-22611)
Vulnerability from cvelistv5 – Published: 2023-01-31 00:00 – Updated: 2025-02-05 20:06
VLAI
Summary
A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Information Exposure
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric | EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) |
Affected:
All , < October 2022
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.470Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-22611",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T19:54:59.647770Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T20:06:52.179Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA)",
"vendor": "Schneider Electric",
"versions": [
{
"lessThan": "October 2022",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-200: Exposure of Sensitive Information to an Unauthorized Actor vulnerability exists that could cause information disclosure when specific messages are sent to the server over the database server TCP port. Affected Products: EcoStruxure Geo SCADA Expert 2019 - 2021 (formerly known as ClearSCADA) (Versions prior to October 2022)"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-03T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-010-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-010-02_Geo_SCADA_Security_Notification.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2023-22611",
"datePublished": "2023-01-31T00:00:00.000Z",
"dateReserved": "2023-01-04T00:00:00.000Z",
"dateUpdated": "2025-02-05T20:06:52.179Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}