Search

Find a vulnerability

Search criteria

    14 vulnerabilities found for EN7528, EN7580 by MediaTek, Inc.

    CVE-2021-31578 (GCVE-0-2021-31578)

    Vulnerability from nvd – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
    VLAI
    Summary
    In Boa, there is a possible escalation of privilege due to a stack buffer overflow. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
    Severity
    No CVSS data available.
    CWE
    • Elevation of Privilege
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.483Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-64"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible escalation of privilege due to a stack buffer overflow. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31578",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:03:33.483Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31577 (GCVE-0-2021-31577)

    Vulnerability from nvd – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
    VLAI
    Summary
    In Boa, there is a possible escalation of privilege due to a missing permission check. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
    Severity
    No CVSS data available.
    CWE
    • Elevation of Privilege
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.246Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-64"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible escalation of privilege due to a missing permission check. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31577",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:03:33.246Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31576 (GCVE-0-2021-31576)

    Vulnerability from nvd – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
    VLAI
    Summary
    In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
    Severity
    No CVSS data available.
    CWE
    • Elevation of Privilege
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.568Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-64"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31576",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:03:33.568Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31575 (GCVE-0-2021-31575)

    Vulnerability from nvd – Published: 2023-02-06 00:00 – Updated: 2025-03-26 15:27
    VLAI
    Summary
    In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-82
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.508Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31575",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T15:27:14.085599Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:27:49.451Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-82"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31575",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2025-03-26T15:27:49.451Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31574 (GCVE-0-2021-31574)

    Vulnerability from nvd – Published: 2023-02-06 00:00 – Updated: 2025-03-26 14:36
    VLAI
    Summary
    In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-82
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.370Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T14:35:21.434500Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T14:36:30.701Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-82"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31574",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2025-03-26T14:36:30.701Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31573 (GCVE-0-2021-31573)

    Vulnerability from nvd – Published: 2023-02-06 00:00 – Updated: 2025-03-26 14:40
    VLAI
    Summary
    In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-82
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.614Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31573",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T14:39:00.883013Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T14:40:09.765Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-82"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31573",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2025-03-26T14:40:09.765Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-32665 (GCVE-0-2022-32665)

    Vulnerability from nvd – Published: 2023-01-03 00:00 – Updated: 2025-04-10 15:57
    VLAI
    Summary
    In Boa, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20220026; Issue ID: OSBNB00144124.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLB7.3.258.100-P1-1555
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:46:45.134Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-bulletin/January-2023"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-32665",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-10T15:56:45.718929Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-10T15:57:02.389Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLB7.3.258.100-P1-1555"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20220026; Issue ID: OSBNB00144124."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-03T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-bulletin/January-2023"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2022-32665",
        "datePublished": "2023-01-03T00:00:00.000Z",
        "dateReserved": "2022-06-09T00:00:00.000Z",
        "dateUpdated": "2025-04-10T15:57:02.389Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31573 (GCVE-0-2021-31573)

    Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2025-03-26 14:40
    VLAI
    Summary
    In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-82
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.614Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31573",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T14:39:00.883013Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T14:40:09.765Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-82"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31573",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2025-03-26T14:40:09.765Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31577 (GCVE-0-2021-31577)

    Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
    VLAI
    Summary
    In Boa, there is a possible escalation of privilege due to a missing permission check. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
    Severity
    No CVSS data available.
    CWE
    • Elevation of Privilege
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.246Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-64"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible escalation of privilege due to a missing permission check. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31577",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:03:33.246Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31574 (GCVE-0-2021-31574)

    Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2025-03-26 14:36
    VLAI
    Summary
    In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-82
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.370Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31574",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T14:35:21.434500Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T14:36:30.701Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-82"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31574",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2025-03-26T14:36:30.701Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31578 (GCVE-0-2021-31578)

    Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
    VLAI
    Summary
    In Boa, there is a possible escalation of privilege due to a stack buffer overflow. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
    Severity
    No CVSS data available.
    CWE
    • Elevation of Privilege
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.483Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-64"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible escalation of privilege due to a stack buffer overflow. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31578",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:03:33.483Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31576 (GCVE-0-2021-31576)

    Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2024-08-03 23:03
    VLAI
    Summary
    In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241.
    Severity
    No CVSS data available.
    CWE
    • Elevation of Privilege
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-64
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.568Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-64"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible information disclosure due to a missing permission check. This could lead to remote information disclosure to a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210008; Issue ID: OSBNB00123241."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31576",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2024-08-03T23:03:33.568Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2021-31575 (GCVE-0-2021-31575)

    Vulnerability from cvelistv5 – Published: 2023-02-06 00:00 – Updated: 2025-03-26 15:27
    VLAI
    Summary
    In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLM7.3.275.0-82
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T23:03:33.508Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-acknowledgements"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2021-31575",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-03-26T15:27:14.085599Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-03-26T15:27:49.451Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLM7.3.275.0-82"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Config Manager, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege from a proximal attacker with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20210009; Issue ID: OSBNB00123234."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-02-06T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-acknowledgements"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2021-31575",
        "datePublished": "2023-02-06T00:00:00.000Z",
        "dateReserved": "2021-04-22T00:00:00.000Z",
        "dateUpdated": "2025-03-26T15:27:49.451Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-32665 (GCVE-0-2022-32665)

    Vulnerability from cvelistv5 – Published: 2023-01-03 00:00 – Updated: 2025-04-10 15:57
    VLAI
    Summary
    In Boa, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20220026; Issue ID: OSBNB00144124.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • Elevation of Privilege
    • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
    Assigner
    Impacted products
    Vendor Product Version
    MediaTek, Inc. EN7528, EN7580 Affected: Linux SDK versions less than TLB7.3.258.100-P1-1555
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T07:46:45.134Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://corp.mediatek.com/product-security-bulletin/January-2023"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-32665",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-04-10T15:56:45.718929Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-77",
                    "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-04-10T15:57:02.389Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "EN7528, EN7580",
              "vendor": "MediaTek, Inc.",
              "versions": [
                {
                  "status": "affected",
                  "version": "Linux SDK versions less than TLB7.3.258.100-P1-1555"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "In Boa, there is a possible command injection due to improper input validation. This could lead to remote escalation of privilege with no additional execution privileges needed. User interaction is not needed for exploitation. Patch ID: A20220026; Issue ID: OSBNB00144124."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Elevation of Privilege",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-01-03T00:00:00.000Z",
            "orgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
            "shortName": "MediaTek"
          },
          "references": [
            {
              "url": "https://corp.mediatek.com/product-security-bulletin/January-2023"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ee979b05-11f8-4f25-a7e0-a1fa9c190374",
        "assignerShortName": "MediaTek",
        "cveId": "CVE-2022-32665",
        "datePublished": "2023-01-03T00:00:00.000Z",
        "dateReserved": "2022-06-09T00:00:00.000Z",
        "dateUpdated": "2025-04-10T15:57:02.389Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }