Search
Find a vulnerability
Search criteria
7 vulnerabilities found for DIVAR IP all-in-one 4000 by Bosch
CVE-2024-33618 (GCVE-0-2024-33618)
Vulnerability from nvd – Published: 2026-04-15 09:51 – Updated: 2026-04-15 13:09
VLAI
Summary
Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1
allows attackers to consume excessive amounts of disk space via network interface.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | BVMS |
Affected:
6.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | BVMS Viewer |
Affected:
8.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 R3 |
Affected:
10.1 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP 7000 R2 |
Affected:
9.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 5000 |
Affected:
9.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 |
Affected:
6.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | DIVAR IP all-in-one 4000 |
Affected:
11.1.1 , ≤ 12.0.1
(custom)
|
|
| Bosch | DIVAR IP all-in-one 6000 |
Affected:
11.1.1 , ≤ 12.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33618",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-15T13:09:08.201665Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T13:09:13.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "11.1.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "11.1.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1 \r\nallows attackers to consume excessive amounts of disk space via network interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T09:51:52.722Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2024-33618",
"datePublished": "2026-04-15T09:51:52.722Z",
"dateReserved": "2024-06-17T09:19:04.535Z",
"dateUpdated": "2026-04-15T13:09:13.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-35867 (GCVE-0-2023-35867)
Vulnerability from nvd – Published: 2023-12-18 12:59 – Updated: 2024-08-02 16:30
VLAI
Summary
An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks.
Severity
5.9 (Medium)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | BVMS |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | BVMS Viewer |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | Configuration Manager |
Affected:
0 , ≤ 7.62
(custom)
|
|
| Bosch | DIVAR IP 7000 R2 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 5000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 7000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 7000 R3 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 4000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 6000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | Project Assistant |
Affected:
0 , ≤ 2.3
(custom)
|
|
| Bosch | Video Security Client |
Affected:
0 , ≤ 3.3.5
(custom)
|
|
| Bosch | BIS Video Engine |
Affected:
0 , ≤ 5.0.1
(custom)
|
|
| Bosch | Intelligent Insights |
Affected:
0 , ≤ 1.0.3.14
(custom)
|
|
| Bosch | ONVIF Camera Event Driver Tool |
Affected:
0 , ≤ 2.0.0.8
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:30:45.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Configuration Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "7.62",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Project Assistant",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Security Client",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.3.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "BIS Video Engine",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "5.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Intelligent Insights",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "1.0.3.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "ONVIF Camera Event Driver Tool",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.0.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:59:48.604Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-35867",
"datePublished": "2023-12-18T12:59:48.604Z",
"dateReserved": "2023-06-19T09:15:32.387Z",
"dateUpdated": "2024-08-02T16:30:45.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28175 (GCVE-0-2023-28175)
Vulnerability from nvd – Published: 2023-06-15 10:14 – Updated: 2024-12-17 20:51
VLAI
Summary
Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | BVMS |
Affected:
7.5 , ≤ 11.1.1
(custom)
|
|
| Bosch | BVMS Viewer |
Affected:
7.5 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP 3000 |
Affected:
7.5 , ≤ 8.0
(custom)
|
|
| Bosch | Bosch DIVAR IP 7000 R1 |
Affected:
7.5 , ≤ 8.0
(custom)
|
|
| Bosch | Bosch DIVAR IP 7000 R2 |
Affected:
7.5 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 R3 |
Affected:
10.1.1 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 5000 |
Affected:
9.0 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 |
Affected:
9.0 , ≤ 11.1.1
(custom)
|
|
| Bosch | DIVAR IP all-in-one 4000 |
Affected:
11.1.1
|
|
| Bosch | DIVAR IP all-in-one 6000 |
Affected:
11.1.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:24.180Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-17T20:49:39.796592Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-17T20:51:14.639Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 3000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.0",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R1",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.0",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "10.1.1",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "11.1.1"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "11.1.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-15T10:14:34.076Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-28175",
"datePublished": "2023-06-15T10:14:34.076Z",
"dateReserved": "2023-03-13T15:46:37.814Z",
"dateUpdated": "2024-12-17T20:51:14.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-33618 (GCVE-0-2024-33618)
Vulnerability from cvelistv5 – Published: 2026-04-15 09:51 – Updated: 2026-04-15 13:09
VLAI
Summary
Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1
allows attackers to consume excessive amounts of disk space via network interface.
Severity
7.5 (High)
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-400 - Uncontrolled Resource Consumption
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
8 products
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | BVMS |
Affected:
6.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | BVMS Viewer |
Affected:
8.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 R3 |
Affected:
10.1 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP 7000 R2 |
Affected:
9.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 5000 |
Affected:
9.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 |
Affected:
6.0 , ≤ 12.0.1
(custom)
|
|
| Bosch | DIVAR IP all-in-one 4000 |
Affected:
11.1.1 , ≤ 12.0.1
(custom)
|
|
| Bosch | DIVAR IP all-in-one 6000 |
Affected:
11.1.1 , ≤ 12.0.1
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-33618",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-04-15T13:09:08.201665Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T13:09:13.468Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "8.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "10.1",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "6.0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "11.1.1",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.1",
"status": "affected",
"version": "11.1.1",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Uncontrolled Resource Consumption in Bosch VMS Central Server in Bosch VMS 12.0.1 \r\nallows attackers to consume excessive amounts of disk space via network interface."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-400",
"description": "CWE-400 Uncontrolled Resource Consumption",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-15T09:51:52.722Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-162032-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2024-33618",
"datePublished": "2026-04-15T09:51:52.722Z",
"dateReserved": "2024-06-17T09:19:04.535Z",
"dateUpdated": "2026-04-15T13:09:13.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2023-35867 (GCVE-0-2023-35867)
Vulnerability from cvelistv5 – Published: 2023-12-18 12:59 – Updated: 2024-08-02 16:30
VLAI
Summary
An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks.
Severity
5.9 (Medium)
CWE
- CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
14 products
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | BVMS |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | BVMS Viewer |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | Configuration Manager |
Affected:
0 , ≤ 7.62
(custom)
|
|
| Bosch | DIVAR IP 7000 R2 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 5000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 7000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 7000 R3 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 4000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | DIVAR IP all-in-one 6000 |
Affected:
0 , ≤ 12.0.0
(custom)
|
|
| Bosch | Project Assistant |
Affected:
0 , ≤ 2.3
(custom)
|
|
| Bosch | Video Security Client |
Affected:
0 , ≤ 3.3.5
(custom)
|
|
| Bosch | BIS Video Engine |
Affected:
0 , ≤ 5.0.1
(custom)
|
|
| Bosch | Intelligent Insights |
Affected:
0 , ≤ 1.0.3.14
(custom)
|
|
| Bosch | ONVIF Camera Event Driver Tool |
Affected:
0 , ≤ 2.0.0.8
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T16:30:45.391Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Configuration Manager",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "7.62",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "12.0.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Project Assistant",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Video Security Client",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "3.3.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "BIS Video Engine",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "5.0.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "Intelligent Insights",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "1.0.3.14",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"product": "ONVIF Camera Event Driver Tool",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "2.0.0.8",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-703",
"description": "CWE-703 Improper Check or Handling of Exceptional Conditions",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-18T12:59:48.604Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-092656-BT.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-35867",
"datePublished": "2023-12-18T12:59:48.604Z",
"dateReserved": "2023-06-19T09:15:32.387Z",
"dateUpdated": "2024-08-02T16:30:45.391Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-28175 (GCVE-0-2023-28175)
Vulnerability from cvelistv5 – Published: 2023-06-15 10:14 – Updated: 2024-12-17 20:51
VLAI
Summary
Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request.
Severity
7.1 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
10 products
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch | BVMS |
Affected:
7.5 , ≤ 11.1.1
(custom)
|
|
| Bosch | BVMS Viewer |
Affected:
7.5 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP 3000 |
Affected:
7.5 , ≤ 8.0
(custom)
|
|
| Bosch | Bosch DIVAR IP 7000 R1 |
Affected:
7.5 , ≤ 8.0
(custom)
|
|
| Bosch | Bosch DIVAR IP 7000 R2 |
Affected:
7.5 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 R3 |
Affected:
10.1.1 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 5000 |
Affected:
9.0 , ≤ 11.1.1
(custom)
|
|
| Bosch | Bosch DIVAR IP all-in-one 7000 |
Affected:
9.0 , ≤ 11.1.1
(custom)
|
|
| Bosch | DIVAR IP all-in-one 4000 |
Affected:
11.1.1
|
|
| Bosch | DIVAR IP all-in-one 6000 |
Affected:
11.1.1
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T12:30:24.180Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-28175",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-17T20:49:39.796592Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-17T20:51:14.639Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BVMS",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "BVMS Viewer",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 3000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.0",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R1",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "8.0",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP 7000 R2",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "7.5",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000 R3",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "10.1.1",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 5000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "Bosch DIVAR IP all-in-one 7000",
"vendor": "Bosch",
"versions": [
{
"lessThanOrEqual": "11.1.1",
"status": "affected",
"version": "9.0",
"versionType": "custom"
}
]
},
{
"product": "DIVAR IP all-in-one 4000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "11.1.1"
}
]
},
{
"product": "DIVAR IP all-in-one 6000",
"vendor": "Bosch",
"versions": [
{
"status": "affected",
"version": "11.1.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Authorization in SSH server in Bosch VMS 11.0, 11.1.0, and 11.1.1 allows a remote authenticated user to access resources within the trusted internal network via a port forwarding request."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-06-15T10:14:34.076Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-025794-bt.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2023-28175",
"datePublished": "2023-06-15T10:14:34.076Z",
"dateReserved": "2023-03-13T15:46:37.814Z",
"dateUpdated": "2024-12-17T20:51:14.639Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
VAR-202312-1220
Vulnerability from variot - Updated: 2024-08-14 14:42An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks. building integration system video engine , bosch video management system , Bosch BVMS Viewer etc. multiple Robert Bosch GmbH There are unspecified vulnerabilities in the product.Service operation interruption (DoS) It may be in a state
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202312-1220",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "onvif camera event driver tool",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "2.0.0.8"
},
{
"model": "video management system",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "divar ip all-in-one 6000",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "divar ip all-in-one 7000 r3",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "building integration system video engine",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "5.0.1"
},
{
"model": "configuration manager",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "7.62"
},
{
"model": "project assistant",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "2.3"
},
{
"model": "video security client",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "3.3.5"
},
{
"model": "divar ip all-in-one 5000",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "divar ip all-in-one 7000",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "divar ip all-in-one 4000",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "divar ip 7000 r2",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "intelligent insights",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "1.0.3.14"
},
{
"model": "video management system viewer",
"scope": "lte",
"trust": 1.0,
"vendor": "bosch",
"version": "12.0"
},
{
"model": "bvms viewer",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "video management system",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip all-in-one 5000",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "project assistant",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip all-in-one 4000",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip all-in-one 6000",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip all-in-one 7000",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip 7000 r2",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "divar ip all-in-one 7000 r3",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "building integration system video engine",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "video security client",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "intelligent insights",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "configuration manager",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
},
{
"model": "onvif camera event driver tool",
"scope": null,
"trust": 0.8,
"vendor": "robert bosch",
"version": null
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"cve": "CVE-2023-35867",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 5.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"exploitabilityScore": 2.2,
"id": "CVE-2023-35867",
"impactScore": 3.6,
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
{
"attackComplexity": "High",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 5.9,
"baseSeverity": "Medium",
"confidentialityImpact": "None",
"exploitabilityScore": null,
"id": "CVE-2023-35867",
"impactScore": null,
"integrityImpact": "None",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-35867",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "psirt@bosch.com",
"id": "CVE-2023-35867",
"trust": 1.0,
"value": "MEDIUM"
},
{
"author": "NVD",
"id": "CVE-2023-35867",
"trust": 0.8,
"value": "Medium"
}
]
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "An improper handling of a malformed API answer packets to API clients in Bosch BT software products can allow an unauthenticated attacker to cause a Denial of Service (DoS) situation. To exploit this vulnerability an attacker has to replace an existing API server e.g. through Man-in-the-Middle attacks. building integration system video engine , bosch video management system , Bosch BVMS Viewer etc. multiple Robert Bosch GmbH There are unspecified vulnerabilities in the product.Service operation interruption (DoS) It may be in a state",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-35867"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
}
],
"trust": 1.62
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-35867",
"trust": 2.6
},
{
"db": "JVNDB",
"id": "JVNDB-2023-020269",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"id": "VAR-202312-1220",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.28333333
},
"last_update_date": "2024-08-14T14:42:54.637000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-703",
"trust": 1.0
},
{
"problemtype": "NVD-CWE-Other",
"trust": 1.0
},
{
"problemtype": "others (CWE-Other) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://psirt.bosch.com/security-advisories/bosch-sa-092656-bt.html"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-35867"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-16T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"date": "2023-12-18T13:15:07.010000",
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-01-16T03:30:00",
"db": "JVNDB",
"id": "JVNDB-2023-020269"
},
{
"date": "2023-12-22T20:13:40.507000",
"db": "NVD",
"id": "CVE-2023-35867"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "plural \u00a0Robert\u00a0Bosch\u00a0GmbH\u00a0 Product vulnerabilities",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-020269"
}
],
"trust": 0.8
}
}