Search
Find a vulnerability
Search criteria
4 vulnerabilities found for CompactLogix® 5370 Compact GuardLogix® 5370 ControlLogix® 5570 GuardLogix® 5570 by Rockwell Automation
CVE-2025-12012 (GCVE-0-2025-12012)
Vulnerability from nvd – Published: 2026-07-14 15:04 – Updated: 2026-07-14 15:26
VLAI
EPSS
VEX
Title
CompactLogix ®, ControlLogix ®, Compact GuardLogix ® and GuardLogix ® Buffer Overflow
Summary
A denial-of-service issue exists in 5380/5480/5580 controllers. This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to enter a major non-recoverable fault (MNRF).
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | CompactLogix® 5370 Compact GuardLogix® 5370 ControlLogix® 5570 GuardLogix® 5570 |
Affected:
V34.012 and earlier V35.011 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12012",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T15:25:51.670680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:26:00.338Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix\u00ae 5370 Compact GuardLogix\u00ae 5370 ControlLogix\u00ae 5570 GuardLogix\u00ae 5570",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "V34.012 and earlier V35.011 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A denial-of-service issue exists in\u0026nbsp;5380/5480/5580\u0026nbsp;controllers.\u0026nbsp;This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to\u0026nbsp;enter a major non-recoverable fault (MNRF).\u0026nbsp;"
}
],
"value": "A denial-of-service issue exists in\u00a05380/5480/5580\u00a0controllers.\u00a0This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to\u00a0enter a major non-recoverable fault (MNRF)."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:04:18.725Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1781.html"
}
],
"source": {
"advisory": "SD1781",
"discovery": "INTERNAL"
},
"title": "CompactLogix \u00ae, ControlLogix \u00ae, Compact GuardLogix \u00ae and GuardLogix \u00ae Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-12012",
"datePublished": "2026-07-14T15:04:18.725Z",
"dateReserved": "2025-10-21T12:58:15.696Z",
"dateUpdated": "2026-07-14T15:26:00.338Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12011 (GCVE-0-2025-12011)
Vulnerability from nvd – Published: 2026-07-14 15:03 – Updated: 2026-07-14 15:26
VLAI
EPSS
VEX
Title
CompactLogix ®, ControlLogix ®, Compact GuardLogix ® and GuardLogix ® Buffer Overflow
Summary
A denial-of-service issue exists in 5370/5570 controllers. This vulnerability could potentially allow a remote user to load an invalid project, causing the device to enter a major non-recoverable fault (MNRF).
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | CompactLogix® 5370 Compact GuardLogix® 5370 ControlLogix® 5570 GuardLogix® 5570 |
Affected:
35.015 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12011",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T15:26:14.053988Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:26:29.661Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix\u00ae 5370 Compact GuardLogix\u00ae 5370 ControlLogix\u00ae 5570 GuardLogix\u00ae 5570",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "35.015 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A denial-of-service issue exists\u0026nbsp;in\u0026nbsp;\u0026nbsp;5370/5570\u0026nbsp;controllers. This vulnerability could potentially allow a\u0026nbsp;remote\u0026nbsp;user to\u0026nbsp;load an invalid project, causing the device to\u0026nbsp;enter\u0026nbsp;a\u0026nbsp;major non-recoverable fault (MNRF).\u0026nbsp;"
}
],
"value": "A denial-of-service issue exists\u00a0in\u00a0\u00a05370/5570\u00a0controllers. This vulnerability could potentially allow a\u00a0remote\u00a0user to\u00a0load an invalid project, causing the device to\u00a0enter\u00a0a\u00a0major non-recoverable fault (MNRF)."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:03:11.708Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1781.html"
}
],
"source": {
"advisory": "SD1781",
"discovery": "UNKNOWN"
},
"title": "CompactLogix \u00ae, ControlLogix \u00ae, Compact GuardLogix \u00ae and GuardLogix \u00ae Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-12011",
"datePublished": "2026-07-14T15:03:11.708Z",
"dateReserved": "2025-10-21T12:56:46.593Z",
"dateUpdated": "2026-07-14T15:26:29.661Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12012 (GCVE-0-2025-12012)
Vulnerability from cvelistv5 – Published: 2026-07-14 15:04 – Updated: 2026-07-14 15:26
VLAI
EPSS
VEX
Title
CompactLogix ®, ControlLogix ®, Compact GuardLogix ® and GuardLogix ® Buffer Overflow
Summary
A denial-of-service issue exists in 5380/5480/5580 controllers. This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to enter a major non-recoverable fault (MNRF).
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | CompactLogix® 5370 Compact GuardLogix® 5370 ControlLogix® 5570 GuardLogix® 5570 |
Affected:
V34.012 and earlier V35.011 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12012",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T15:25:51.670680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:26:00.338Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix\u00ae 5370 Compact GuardLogix\u00ae 5370 ControlLogix\u00ae 5570 GuardLogix\u00ae 5570",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "V34.012 and earlier V35.011 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A denial-of-service issue exists in\u0026nbsp;5380/5480/5580\u0026nbsp;controllers.\u0026nbsp;This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to\u0026nbsp;enter a major non-recoverable fault (MNRF).\u0026nbsp;"
}
],
"value": "A denial-of-service issue exists in\u00a05380/5480/5580\u00a0controllers.\u00a0This vulnerability could potentially allow a malicious user to write invalid file data to the controller, causing the device to\u00a0enter a major non-recoverable fault (MNRF)."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:04:18.725Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1781.html"
}
],
"source": {
"advisory": "SD1781",
"discovery": "INTERNAL"
},
"title": "CompactLogix \u00ae, ControlLogix \u00ae, Compact GuardLogix \u00ae and GuardLogix \u00ae Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-12012",
"datePublished": "2026-07-14T15:04:18.725Z",
"dateReserved": "2025-10-21T12:58:15.696Z",
"dateUpdated": "2026-07-14T15:26:00.338Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-12011 (GCVE-0-2025-12011)
Vulnerability from cvelistv5 – Published: 2026-07-14 15:03 – Updated: 2026-07-14 15:26
VLAI
EPSS
VEX
Title
CompactLogix ®, ControlLogix ®, Compact GuardLogix ® and GuardLogix ® Buffer Overflow
Summary
A denial-of-service issue exists in 5370/5570 controllers. This vulnerability could potentially allow a remote user to load an invalid project, causing the device to enter a major non-recoverable fault (MNRF).
Severity
SSVC
Exploitation: none
Automatable: yes
Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Rockwell Automation | CompactLogix® 5370 Compact GuardLogix® 5370 ControlLogix® 5570 GuardLogix® 5570 |
Affected:
35.015 and earlier
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-12011",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-07-14T15:26:14.053988Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:26:29.661Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CompactLogix\u00ae 5370 Compact GuardLogix\u00ae 5370 ControlLogix\u00ae 5570 GuardLogix\u00ae 5570",
"vendor": "Rockwell Automation",
"versions": [
{
"status": "affected",
"version": "35.015 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A denial-of-service issue exists\u0026nbsp;in\u0026nbsp;\u0026nbsp;5370/5570\u0026nbsp;controllers. This vulnerability could potentially allow a\u0026nbsp;remote\u0026nbsp;user to\u0026nbsp;load an invalid project, causing the device to\u0026nbsp;enter\u0026nbsp;a\u0026nbsp;major non-recoverable fault (MNRF).\u0026nbsp;"
}
],
"value": "A denial-of-service issue exists\u00a0in\u00a0\u00a05370/5570\u00a0controllers. This vulnerability could potentially allow a\u00a0remote\u00a0user to\u00a0load an invalid project, causing the device to\u00a0enter\u00a0a\u00a0major non-recoverable fault (MNRF)."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 9.2,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-07-14T15:03:11.708Z",
"orgId": "b73dd486-f505-4403-b634-40b078b177f0",
"shortName": "Rockwell"
},
"references": [
{
"url": "https://www.rockwellautomation.com/en-us/trust-center/security-advisories/advisory.SD1781.html"
}
],
"source": {
"advisory": "SD1781",
"discovery": "UNKNOWN"
},
"title": "CompactLogix \u00ae, ControlLogix \u00ae, Compact GuardLogix \u00ae and GuardLogix \u00ae Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 1.0.2"
}
}
},
"cveMetadata": {
"assignerOrgId": "b73dd486-f505-4403-b634-40b078b177f0",
"assignerShortName": "Rockwell",
"cveId": "CVE-2025-12011",
"datePublished": "2026-07-14T15:03:11.708Z",
"dateReserved": "2025-10-21T12:56:46.593Z",
"dateUpdated": "2026-07-14T15:26:29.661Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}