    CVE-2026-42808 (GCVE-0-2026-42808)

    Vulnerability from nvd – Published: 2026-09-10 09:05 – Updated: 2026-09-10 13:17
    VLAI
    Summary
    An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.  The host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer. Internally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer's accumulated data into {{coines_stream_rsp_buf}}. Subsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough. A malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment. This can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 13:17 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    References
    Impacted products
    Vendor Product Version
    Bosch Sensortec COINES_SDK Affected: 2.0 , ≤ 2.11 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42808",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T13:17:29.757002Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T13:17:41.450Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "COINES_SDK",
              "vendor": "Bosch Sensortec",
              "versions": [
                {
                  "lessThanOrEqual": "2.11",
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.\u00a0\r\n\r\nThe host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.\r\n\r\nInternally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer\u0027s accumulated data into {{coines_stream_rsp_buf}}.\r\n\r\nSubsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.\r\n\r\nA malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.\r\n\r\nThis can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T09:05:36.803Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2026-42808",
        "datePublished": "2026-09-10T09:05:36.803Z",
        "dateReserved": "2026-04-30T08:03:11.875Z",
        "dateUpdated": "2026-09-10T13:17:41.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42807 (GCVE-0-2026-42807)

    Vulnerability from nvd – Published: 2026-09-10 09:05 – Updated: 2026-09-10 15:00
    VLAI
    Summary
    A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. The bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. A malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. This results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 14:59 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Bosch Sensortec COINES_SDK Affected: 2.10 , ≤ 2.12.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42807",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T14:59:49.196198Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T15:00:04.892Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "COINES_SDK",
              "vendor": "Bosch Sensortec",
              "versions": [
                {
                  "lessThanOrEqual": "2.12.2",
                  "status": "affected",
                  "version": "2.10",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device\u0027s response."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T09:05:10.550Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2026-42807",
        "datePublished": "2026-09-10T09:05:10.550Z",
        "dateReserved": "2026-04-30T08:03:11.875Z",
        "dateUpdated": "2026-09-10T15:00:04.892Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42808 (GCVE-0-2026-42808)

    Vulnerability from cvelistv5 – Published: 2026-09-10 09:05 – Updated: 2026-09-10 13:17
    VLAI
    Summary
    An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.  The host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer. Internally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer's accumulated data into {{coines_stream_rsp_buf}}. Subsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough. A malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment. This can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 13:17 UTC
    CWE
    • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
    References
    Impacted products
    Vendor Product Version
    Bosch Sensortec COINES_SDK Affected: 2.0 , ≤ 2.11 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42808",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T13:17:29.757002Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T13:17:41.450Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "COINES_SDK",
              "vendor": "Bosch Sensortec",
              "versions": [
                {
                  "lessThanOrEqual": "2.11",
                  "status": "affected",
                  "version": "2.0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.\u00a0\r\n\r\nThe host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.\r\n\r\nInternally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer\u0027s accumulated data into {{coines_stream_rsp_buf}}.\r\n\r\nSubsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.\r\n\r\nA malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.\r\n\r\nThis can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "PHYSICAL",
                "availabilityImpact": "HIGH",
                "baseScore": 6.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-120",
                  "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T09:05:36.803Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2026-42808",
        "datePublished": "2026-09-10T09:05:36.803Z",
        "dateReserved": "2026-04-30T08:03:11.875Z",
        "dateUpdated": "2026-09-10T13:17:41.450Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-42807 (GCVE-0-2026-42807)

    Vulnerability from cvelistv5 – Published: 2026-09-10 09:05 – Updated: 2026-09-10 15:00
    VLAI
    Summary
    A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. The bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. A malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. This results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-10 14:59 UTC
    CWE
    • CWE-122 - Heap-based Buffer Overflow
    References
    Impacted products
    Vendor Product Version
    Bosch Sensortec COINES_SDK Affected: 2.10 , ≤ 2.12.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-42807",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-10T14:59:49.196198Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-10T15:00:04.892Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "COINES_SDK",
              "vendor": "Bosch Sensortec",
              "versions": [
                {
                  "lessThanOrEqual": "2.12.2",
                  "status": "affected",
                  "version": "2.10",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device\u0027s response."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "ADJACENT_NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-122",
                  "description": "CWE-122 Heap-based Buffer Overflow",
                  "lang": "en-US"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-10T09:05:10.550Z",
            "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
            "shortName": "bosch"
          },
          "references": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "assignerShortName": "bosch",
        "cveId": "CVE-2026-42807",
        "datePublished": "2026-09-10T09:05:10.550Z",
        "dateReserved": "2026-04-30T08:03:11.875Z",
        "dateUpdated": "2026-09-10T15:00:04.892Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }