CVE-2026-42808 (GCVE-0-2026-42808)
Vulnerability from nvd – Published: 2026-09-10 09:05 – Updated: 2026-09-10 13:17
VLAI
EPSS
VEX
Summary
An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.
The host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.
Internally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer's accumulated data into {{coines_stream_rsp_buf}}.
Subsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.
A malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.
This can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 13:17 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch Sensortec | COINES_SDK |
Affected:
2.0 , ≤ 2.11
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42808",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T13:17:29.757002Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T13:17:41.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "COINES_SDK",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "2.11",
"status": "affected",
"version": "2.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.\u00a0\r\n\r\nThe host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.\r\n\r\nInternally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer\u0027s accumulated data into {{coines_stream_rsp_buf}}.\r\n\r\nSubsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.\r\n\r\nA malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.\r\n\r\nThis can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:05:36.803Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42808",
"datePublished": "2026-09-10T09:05:36.803Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T13:17:41.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-42807 (GCVE-0-2026-42807)
Vulnerability from nvd – Published: 2026-09-10 09:05 – Updated: 2026-09-10 15:00
VLAI
EPSS
VEX
Summary
A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code.
The bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer.
A malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes.
This results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 14:59 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch Sensortec | COINES_SDK |
Affected:
2.10 , ≤ 2.12.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42807",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T14:59:49.196198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T15:00:04.892Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "COINES_SDK",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "2.12.2",
"status": "affected",
"version": "2.10",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device\u0027s response."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:05:10.550Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42807",
"datePublished": "2026-09-10T09:05:10.550Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T15:00:04.892Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-42808 (GCVE-0-2026-42808)
Vulnerability from cvelistv5 – Published: 2026-09-10 09:05 – Updated: 2026-09-10 13:17
VLAI
EPSS
VEX
Summary
An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.
The host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.
Internally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer's accumulated data into {{coines_stream_rsp_buf}}.
Subsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.
A malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.
This can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine.
Severity
6.8 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 13:17 UTC
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch Sensortec | COINES_SDK |
Affected:
2.0 , ≤ 2.11
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42808",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T13:17:29.757002Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T13:17:41.450Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "COINES_SDK",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "2.11",
"status": "affected",
"version": "2.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in Bosch Sensortec COINES_SDK versions 2.0 through 2.11.\u00a0\r\n\r\nThe host streaming API function {{coines_read_stream_sensor_data()}} fails to validate the boundaries of the caller-provided destination buffer.\r\n\r\nInternally, the stream processing mechanism in {{comm_intf_process_stream_response()}} discards the requested {{number_of_samples}} argument and copies the entirety of the streaming ring buffer\u0027s accumulated data into {{coines_stream_rsp_buf}}.\r\n\r\nSubsequently, {{coines_read_stream_sensor_data()}} unconditionally executes a {{memcpy}} of the ring buffer size into the caller-provided buffer without verifying if the destination memory allocation is large enough.\r\n\r\nA malicious or compromised hardware board connected via USB or BLE can exploit this by streaming a high volume of sensor samples, causing a heap or stack-based buffer overflow on the host desktop environment.\r\n\r\nThis can result in a Denial of Service (DoS) or potential arbitrary code execution on the host machine."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:05:36.803Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42808",
"datePublished": "2026-09-10T09:05:36.803Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T13:17:41.450Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-42807 (GCVE-0-2026-42807)
Vulnerability from cvelistv5 – Published: 2026-09-10 09:05 – Updated: 2026-09-10 15:00
VLAI
EPSS
VEX
Summary
A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code.
The bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer.
A malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes.
This results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device's response.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 14:59 UTC
CWE
- CWE-122 - Heap-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch Sensortec | COINES_SDK |
Affected:
2.10 , ≤ 2.12.2
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42807",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T14:59:49.196198Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T15:00:04.892Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "COINES_SDK",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "2.12.2",
"status": "affected",
"version": "2.10",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow vulnerability in the PC bridge protocol decoder of BoschSensortec COINES_SDK (versions 2.10 through 2.12.2) allows attackers to cause a denial of service (process crash) or potentially execute arbitrary code. \r\n\r\nThe bridge decoder ({{bridge_decoder.c}}) trusts the packet length field provided by the external device and forwards it to the host response queue ({{mqueue_add_data}}) without validating the bounds of the destination buffer. \r\n\r\nA malicious or compromised USB or Bluetooth Low Energy (BLE) peripheral can advertise a payload size up to ~3 KB, which exceeds the default queue slot size of 255 bytes. \r\n\r\nThis results in an unbounded heap overwrite ({{memcpy}}), corrupting adjacent heap metadata on the host system when processing the device\u0027s response."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-122",
"description": "CWE-122 Heap-based Buffer Overflow",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:05:10.550Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42807",
"datePublished": "2026-09-10T09:05:10.550Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T15:00:04.892Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}