CVE-2026-82793 (GCVE-0-2026-82793)
Vulnerability from nvd – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:40
VLAI
EPSS
VEX
Summary
Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:39 UTC
CWE
- CWE-434 - Unrestricted upload of file with dangerous type
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82793",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:39:25.591689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:40:46.929Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "Unrestricted upload of file with dangerous type",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:52.775Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82793",
"datePublished": "2026-09-14T06:45:52.775Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T11:40:46.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82792 (GCVE-0-2026-82792)
Vulnerability from nvd – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:57
VLAI
EPSS
VEX
Summary
Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user's web browser.
Severity
5.2 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:57 UTC
CWE
- CWE-79 - Cross-site scripting (XSS)
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:57:40.788477Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:57:52.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user\u0027s web browser."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross-site scripting (XSS)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:32.630Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82792",
"datePublished": "2026-09-14T06:45:32.630Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T11:57:52.643Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82791 (GCVE-0-2026-82791)
Vulnerability from nvd – Published: 2026-09-14 06:45 – Updated: 2026-09-14 12:07
VLAI
EPSS
VEX
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 12:07 UTC
CWE
- CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82791",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T12:07:44.065201Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T12:07:55.617Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:22.083Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82791",
"datePublished": "2026-09-14T06:45:22.083Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T12:07:55.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82793 (GCVE-0-2026-82793)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:40
VLAI
EPSS
VEX
Summary
Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:39 UTC
CWE
- CWE-434 - Unrestricted upload of file with dangerous type
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82793",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:39:25.591689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:40:46.929Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.2,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-434",
"description": "Unrestricted upload of file with dangerous type",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:52.775Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82793",
"datePublished": "2026-09-14T06:45:52.775Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T11:40:46.929Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82792 (GCVE-0-2026-82792)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:57
VLAI
EPSS
VEX
Summary
Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user's web browser.
Severity
5.2 (Medium)
SSVC
Exploitation: none
Automatable: no
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 11:57 UTC
CWE
- CWE-79 - Cross-site scripting (XSS)
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82792",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T11:57:40.788477Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T11:57:52.643Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user\u0027s web browser."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 5.2,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 4.8,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Cross-site scripting (XSS)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:32.630Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82792",
"datePublished": "2026-09-14T06:45:32.630Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T11:57:52.643Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-82791 (GCVE-0-2026-82791)
Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 12:07
VLAI
EPSS
VEX
Summary
Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.
Severity
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-14 12:07 UTC
CWE
- CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Contec Co., Ltd. | CAN-2-WF |
Affected:
0 , < 2.20
(semver)
|
|
| Contec Co., Ltd. | CAN-2-USB |
Affected:
0 , < 2.20
(semver)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-82791",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-14T12:07:44.065201Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T12:07:55.617Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "CAN-2-WF",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"defaultStatus": "unaffected",
"product": "CAN-2-USB",
"vendor": "Contec Co., Ltd.",
"versions": [
{
"lessThan": "2.20",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 8.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en-US",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
"lang": "en-US",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-14T06:45:22.083Z",
"orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"shortName": "jpcert"
},
"references": [
{
"url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
},
{
"url": "https://jvn.jp/en/vu/JVNVU90314828/"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
"assignerShortName": "jpcert",
"cveId": "CVE-2026-82791",
"datePublished": "2026-09-14T06:45:22.083Z",
"dateReserved": "2026-08-31T02:30:58.279Z",
"dateUpdated": "2026-09-14T12:07:55.617Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}