GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    6 vulnerabilities found for CAN-2-WF by Contec Co., Ltd.

    CVE-2026-82793 (GCVE-0-2026-82793)

    Vulnerability from nvd – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:40
    VLAI
    Summary
    Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 11:39 UTC
    CWE
    • CWE-434 - Unrestricted upload of file with dangerous type
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82793",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T11:39:25.591689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T11:40:46.929Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "Unrestricted upload of file with dangerous type",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:52.775Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82793",
        "datePublished": "2026-09-14T06:45:52.775Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T11:40:46.929Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82792 (GCVE-0-2026-82792)

    Vulnerability from nvd – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:57
    VLAI
    Summary
    Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user's web browser.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 11:57 UTC
    CWE
    • CWE-79 - Cross-site scripting (XSS)
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82792",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T11:57:40.788477Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T11:57:52.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user\u0027s web browser."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Cross-site scripting (XSS)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:32.630Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82792",
        "datePublished": "2026-09-14T06:45:32.630Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T11:57:52.643Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82791 (GCVE-0-2026-82791)

    Vulnerability from nvd – Published: 2026-09-14 06:45 – Updated: 2026-09-14 12:07
    VLAI
    Summary
    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 12:07 UTC
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82791",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T12:07:44.065201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T12:07:55.617Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:22.083Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82791",
        "datePublished": "2026-09-14T06:45:22.083Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T12:07:55.617Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82793 (GCVE-0-2026-82793)

    Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:40
    VLAI
    Summary
    Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 11:39 UTC
    CWE
    • CWE-434 - Unrestricted upload of file with dangerous type
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82793",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T11:39:25.591689Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T11:40:46.929Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Unrestricted upload of file with dangerous type issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If a specially crafted file is uploaded by a remote authenticated attacker, arbitrary code may be executed on the product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 7.2,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.6,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-434",
                  "description": "Unrestricted upload of file with dangerous type",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:52.775Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82793",
        "datePublished": "2026-09-14T06:45:52.775Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T11:40:46.929Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82792 (GCVE-0-2026-82792)

    Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 11:57
    VLAI
    Summary
    Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user's web browser.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 11:57 UTC
    CWE
    • CWE-79 - Cross-site scripting (XSS)
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82792",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T11:57:40.788477Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T11:57:52.643Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting vulnerability exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary script may be executed on a logged-in user\u0027s web browser."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 5.2,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 4.8,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:A/VC:N/VI:N/VA:N/SC:L/SI:L/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-79",
                  "description": "Cross-site scripting (XSS)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:32.630Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82792",
        "datePublished": "2026-09-14T06:45:32.630Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T11:57:52.643Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-82791 (GCVE-0-2026-82791)

    Vulnerability from cvelistv5 – Published: 2026-09-14 06:45 – Updated: 2026-09-14 12:07
    VLAI
    Summary
    Improper neutralization of special elements used in an OS command ('OS Command Injection') issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-14 12:07 UTC
    CWE
    • CWE-78 - Improper neutralization of special elements used in an OS command ('OS Command Injection')
    Impacted products
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-82791",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-14T12:07:44.065201Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-14T12:07:55.617Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-WF",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CAN-2-USB",
              "vendor": "Contec Co., Ltd.",
              "versions": [
                {
                  "lessThan": "2.20",
                  "status": "affected",
                  "version": "0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027) issue exists in Contec CAN 2.0B Communication Wireless LAN / USB Converter Unit. If this vulnerability is exploited, an arbitrary OS command may be executed by an attacker who can log in to the product."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en-US",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-78",
                  "description": "Improper neutralization of special elements used in an OS command (\u0027OS Command Injection\u0027)",
                  "lang": "en-US",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-14T06:45:22.083Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "url": "https://www.contec.com/api/downloadlogger?download=/-/media/Contec/support/security-info/2026/contec_security_ph_26091000_en.pdf"
            },
            {
              "url": "https://jvn.jp/en/vu/JVNVU90314828/"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2026-82791",
        "datePublished": "2026-09-14T06:45:22.083Z",
        "dateReserved": "2026-08-31T02:30:58.279Z",
        "dateUpdated": "2026-09-14T12:07:55.617Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }