GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration
Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for Bixby Touch by Samsung Mobile

    CVE-2026-21108 (GCVE-0-2026-21108)

    Vulnerability from nvd – Published: 2026-09-09 04:47 – Updated: 2026-09-09 20:24
    VLAI
    Summary
    Improper export of android application components in Bixby Touch prior to version 4.3.01.17 allows local attackers to access sensitive information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-09 20:23 UTC
    CWE
    • CWE-926 - Improper Export of Android Application Components
    Assigner
    Impacted products
    Vendor Product Version
    Samsung Mobile Bixby Touch Unaffected: 4.3.01.17 , < * (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-21108",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-09T20:23:24.046639Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-926",
                    "description": "CWE-926 Improper Export of Android Application Components",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-09T20:24:26.569Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Bixby Touch",
              "vendor": "Samsung Mobile",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "4.3.01.17",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper export of android application components in Bixby Touch prior to version 4.3.01.17 allows local attackers to access sensitive information."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-926: Improper Export of Android Application Components",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-09T04:47:58.196Z",
            "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
            "shortName": "SamsungMobile"
          },
          "references": [
            {
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2026\u0026month=09"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "assignerShortName": "SamsungMobile",
        "cveId": "CVE-2026-21108",
        "datePublished": "2026-09-09T04:47:58.196Z",
        "dateReserved": "2025-12-11T01:33:35.830Z",
        "dateUpdated": "2026-09-09T20:24:26.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-21465 (GCVE-0-2023-21465)

    Vulnerability from nvd – Published: 2023-03-16 00:00 – Updated: 2024-08-02 09:36
    VLAI
    Summary
    Improper access control vulnerability in BixbyTouch prior to version 3.2.02.5 in China models allows untrusted applications access local files.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    Samsung Mobile Bixby Touch Affected: unspecified , < 3.2.02.5 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T09:36:34.523Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2023\u0026month=03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Bixby Touch",
              "vendor": "Samsung Mobile",
              "versions": [
                {
                  "lessThan": "3.2.02.5",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in BixbyTouch prior to version 3.2.02.5 in China models allows untrusted applications access local files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-16T00:00:00.000Z",
            "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
            "shortName": "Samsung Mobile"
          },
          "references": [
            {
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2023\u0026month=03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "assignerShortName": "Samsung Mobile",
        "cveId": "CVE-2023-21465",
        "datePublished": "2023-03-16T00:00:00.000Z",
        "dateReserved": "2022-11-14T00:00:00.000Z",
        "dateUpdated": "2024-08-02T09:36:34.523Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2026-21108 (GCVE-0-2026-21108)

    Vulnerability from cvelistv5 – Published: 2026-09-09 04:47 – Updated: 2026-09-09 20:24
    VLAI
    Summary
    Improper export of android application components in Bixby Touch prior to version 4.3.01.17 allows local attackers to access sensitive information.
    SSVC
    Exploitation: none Automatable: no Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2026-09-09 20:23 UTC
    CWE
    • CWE-926 - Improper Export of Android Application Components
    Assigner
    Impacted products
    Vendor Product Version
    Samsung Mobile Bixby Touch Unaffected: 4.3.01.17 , < * (semver)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-21108",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-09-09T20:23:24.046639Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-926",
                    "description": "CWE-926 Improper Export of Android Application Components",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-09-09T20:24:26.569Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "affected",
              "product": "Bixby Touch",
              "vendor": "Samsung Mobile",
              "versions": [
                {
                  "lessThan": "*",
                  "status": "unaffected",
                  "version": "4.3.01.17",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper export of android application components in Bixby Touch prior to version 4.3.01.17 allows local attackers to access sensitive information."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "LOCAL",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE"
              },
              "format": "CVSS"
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-926: Improper Export of Android Application Components",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-09-09T04:47:58.196Z",
            "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
            "shortName": "SamsungMobile"
          },
          "references": [
            {
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2026\u0026month=09"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "assignerShortName": "SamsungMobile",
        "cveId": "CVE-2026-21108",
        "datePublished": "2026-09-09T04:47:58.196Z",
        "dateReserved": "2025-12-11T01:33:35.830Z",
        "dateUpdated": "2026-09-09T20:24:26.569Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2023-21465 (GCVE-0-2023-21465)

    Vulnerability from cvelistv5 – Published: 2023-03-16 00:00 – Updated: 2024-08-02 09:36
    VLAI
    Summary
    Improper access control vulnerability in BixbyTouch prior to version 3.2.02.5 in China models allows untrusted applications access local files.
    CWE
    • CWE-284 - Improper Access Control
    Assigner
    Impacted products
    Vendor Product Version
    Samsung Mobile Bixby Touch Affected: unspecified , < 3.2.02.5 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T09:36:34.523Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2023\u0026month=03"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Bixby Touch",
              "vendor": "Samsung Mobile",
              "versions": [
                {
                  "lessThan": "3.2.02.5",
                  "status": "affected",
                  "version": "unspecified",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Improper access control vulnerability in BixbyTouch prior to version 3.2.02.5 in China models allows untrusted applications access local files."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "NONE",
                "baseScore": 5.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-284",
                  "description": "CWE-284: Improper Access Control",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-03-16T00:00:00.000Z",
            "orgId": "3af57064-a867-422c-b2ad-40307b65c458",
            "shortName": "Samsung Mobile"
          },
          "references": [
            {
              "url": "https://security.samsungmobile.com/serviceWeb.smsb?year=2023\u0026month=03"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "3af57064-a867-422c-b2ad-40307b65c458",
        "assignerShortName": "Samsung Mobile",
        "cveId": "CVE-2023-21465",
        "datePublished": "2023-03-16T00:00:00.000Z",
        "dateReserved": "2022-11-14T00:00:00.000Z",
        "dateUpdated": "2024-08-02T09:36:34.523Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }