Search
Find a vulnerability
Search criteria
2 vulnerabilities found for BHI385 SensorAPI (C Library) by Bosch Sensortec
CVE-2026-42805 (GCVE-0-2026-42805)
Vulnerability from nvd – Published: 2026-09-10 09:04 – Updated: 2026-09-10 15:01
VLAI
EPSS
VEX
Summary
A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c).
The function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info->data_ptr[0]) without enforcing bounds checks or clamping the value.
When copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary.
This memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 15:01 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch Sensortec | BHI385 SensorAPI (C Library) |
Affected:
1.1.0 , ≤ 2.1.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42805",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T15:01:13.115369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T15:01:26.029Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BHI385 SensorAPI (C Library)",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "2.1.0",
"status": "affected",
"version": "1.1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c). \r\n\r\nThe function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info-\u003edata_ptr[0]) without enforcing bounds checks or clamping the value.\r\n\r\nWhen copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary. \r\n\r\nThis memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:04:09.212Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42805",
"datePublished": "2026-09-10T09:04:09.212Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T15:01:26.029Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-42805 (GCVE-0-2026-42805)
Vulnerability from cvelistv5 – Published: 2026-09-10 09:04 – Updated: 2026-09-10 15:01
VLAI
EPSS
VEX
Summary
A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c).
The function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info->data_ptr[0]) without enforcing bounds checks or clamping the value.
When copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary.
This memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption.
Severity
8.4 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-09-10 15:01 UTC
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://psirt.bosch.com/security-advisories/BOSCH… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Bosch Sensortec | BHI385 SensorAPI (C Library) |
Affected:
1.1.0 , ≤ 2.1.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-42805",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-09-10T15:01:13.115369Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T15:01:26.029Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "BHI385 SensorAPI (C Library)",
"vendor": "Bosch Sensortec",
"versions": [
{
"lessThanOrEqual": "2.1.0",
"status": "affected",
"version": "1.1.0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A stack-based buffer overflow vulnerability exists in the Bosch Sensortec BHI385 SensorAPI (C library) within the debug message parser function bhi385_parse_debug_message (located in bhi385_parse.c). \r\n\r\nThe function parses FIFO events and extracts an 8-bit message length directly from the attacker-controlled event payload (callback_info-\u003edata_ptr[0]) without enforcing bounds checks or clamping the value.\r\n\r\nWhen copying the payload into a fixed-size stack buffer of 17 bytes (uint8_t debug_msg[17]) via memcpy, providing a length byte greater than 16 causes the function to write past the allocated stack boundary. \r\n\r\nThis memory corruption can be triggered by a malicious or compromised sensor or bus participant, leading to a firmware crash, Denial of Service (DoS), or potentially the execution of arbitrary code via adjacent stack data corruption."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en-US"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-09-10T09:04:09.212Z",
"orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"shortName": "bosch"
},
"references": [
{
"name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html",
"tags": [
"vendor-advisory"
],
"url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-223618.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
"assignerShortName": "bosch",
"cveId": "CVE-2026-42805",
"datePublished": "2026-09-10T09:04:09.212Z",
"dateReserved": "2026-04-30T08:03:11.875Z",
"dateUpdated": "2026-09-10T15:01:26.029Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",