    CVE-2018-16195 (GCVE-0-2018-16195)

    Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP.
    Severity
    No CVSS data available.
    CWE
    • OS Command Injection
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.325Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16195",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16195",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.325Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16194 (GCVE-0-2018-16194)

    Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • OS Command Injection
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.393Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16194",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16194",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16193 (GCVE-0-2018-16193)

    Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Cross-site scripting
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.355Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-site scripting",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16193",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16193",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16192 (GCVE-0-2018-16192)

    Vulnerability from nvd – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Information Disclosure
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.386Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16192",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Information Disclosure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16192",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.386Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16194 (GCVE-0-2018-16194)

    Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • OS Command Injection
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.393Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16194",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to execute arbitrary OS commands via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16194",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.393Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16193 (GCVE-0-2018-16193)

    Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Cross-site scripting
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.355Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Cross-site scripting",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16193",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Cross-site scripting vulnerability in Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows authenticated attackers to inject arbitrary web script or HTML via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Cross-site scripting"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16193",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.355Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16192 (GCVE-0-2018-16192)

    Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors.
    Severity
    No CVSS data available.
    CWE
    • Information Disclosure
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.386Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "Information Disclosure",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16192",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allow an attacker on the same network segment to obtain information registered on the device via unspecified vectors."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "Information Disclosure"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16192",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.386Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2018-16195 (GCVE-0-2018-16195)

    Vulnerability from cvelistv5 – Published: 2019-01-09 22:00 – Updated: 2024-08-05 10:17
    VLAI
    Summary
    Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP.
    Severity
    No CVSS data available.
    CWE
    • OS Command Injection
    Assigner
    References
    Impacted products
    Vendor Product Version
    NEC Corporation Aterm WF1200CR and Aterm WG1200CR Affected: (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)
    Create a notification for this product.
    Date Public
    2019-01-09 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T10:17:38.325Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "name": "JVN#87535892",
                "tags": [
                  "third-party-advisory",
                  "x_refsource_JVN",
                  "x_transferred"
                ],
                "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
              }
            ],
            "title": "CVE Program Container"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Aterm WF1200CR and Aterm WG1200CR",
              "vendor": "NEC Corporation",
              "versions": [
                {
                  "status": "affected",
                  "version": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                }
              ]
            }
          ],
          "datePublic": "2019-01-09T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "OS Command Injection",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2019-01-09T21:57:01.000Z",
            "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
            "shortName": "jpcert"
          },
          "references": [
            {
              "name": "JVN#87535892",
              "tags": [
                "third-party-advisory",
                "x_refsource_JVN"
              ],
              "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "vultures@jpcert.or.jp",
              "ID": "CVE-2018-16195",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "Aterm WF1200CR and Aterm WG1200CR",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "(Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier)"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "NEC Corporation"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "Aterm WF1200CR and Aterm WG1200CR (Aterm WF1200CR firmware Ver1.1.1 and earlier, Aterm WG1200CR firmware Ver1.0.1 and earlier) allows an attacker on the same network segment to execute arbitrary OS commands via SOAP interface of UPnP."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "OS Command Injection"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "JVN#87535892",
                  "refsource": "JVN",
                  "url": "https://jvn.jp/en/jp/JVN87535892/index.html"
                },
                {
                  "name": "https://jpn.nec.com/security-info/secinfo/nv18-021.html",
                  "refsource": "MISC",
                  "url": "https://jpn.nec.com/security-info/secinfo/nv18-021.html"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "assignerShortName": "jpcert",
        "cveId": "CVE-2018-16195",
        "datePublished": "2019-01-09T22:00:00.000Z",
        "dateReserved": "2018-08-30T00:00:00.000Z",
        "dateUpdated": "2024-08-05T10:17:38.325Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }