Search criteria

2 vulnerabilities found for Archer AX72 (SG) v1.0 by TP-Link Systems Inc.

CVE-2026-5511 (GCVE-0-2026-5511)

Vulnerability from nvd – Published: 2026-05-19 15:58 – Updated: 2026-05-19 17:06
VLAI
Title
Information Disclosure via Diagnostic Interface Due to Improper Input Validation on TP-Link's Archer AX72
Summary
In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.  An authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options.  The exposed information is limited in scope and does not include sensitive system data.
CWE
  • CWE-209 - Generation of error message containing sensitive information
Assigner
Impacted products
Vendor Product Version
TP-Link Systems Inc. Archer AX72 (SG) v1.0 Affected: 0 , < 1.4.6 Build 20260112 rel.66206 (custom)
Create a notification for this product.
Credits
George Chen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5511",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-19T17:05:56.109153Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-19T17:06:21.425Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Archer AX72 (SG) v1.0",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.4.6 Build 20260112 rel.66206",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "George Chen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.\u0026nbsp;\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eAn authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options.\u0026nbsp; The exposed information is limited in scope and does not include sensitive system data.\u003c/div\u003e"
            }
          ],
          "value": "In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.\u00a0\n\n\nAn authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options.\u00a0 The exposed information is limited in scope and does not include sensitive system data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-54",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-54 Query System for Information"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-209",
              "description": "CWE-209 Generation of error message containing sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-19T15:58:46.404Z",
        "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "shortName": "TPLink"
      },
      "references": [
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.tp-link.com/sg/support/download/archer-ax72/#Firmware"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.tp-link.com/us/support/faq/5096/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure via Diagnostic Interface Due to Improper Input Validation on TP-Link\u0027s Archer AX72",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
    "assignerShortName": "TPLink",
    "cveId": "CVE-2026-5511",
    "datePublished": "2026-05-19T15:58:46.404Z",
    "dateReserved": "2026-04-03T17:31:05.618Z",
    "dateUpdated": "2026-05-19T17:06:21.425Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-5511 (GCVE-0-2026-5511)

Vulnerability from cvelistv5 – Published: 2026-05-19 15:58 – Updated: 2026-05-19 17:06
VLAI
Title
Information Disclosure via Diagnostic Interface Due to Improper Input Validation on TP-Link's Archer AX72
Summary
In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.  An authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options.  The exposed information is limited in scope and does not include sensitive system data.
CWE
  • CWE-209 - Generation of error message containing sensitive information
Assigner
Impacted products
Vendor Product Version
TP-Link Systems Inc. Archer AX72 (SG) v1.0 Affected: 0 , < 1.4.6 Build 20260112 rel.66206 (custom)
Create a notification for this product.
Credits
George Chen
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-5511",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-05-19T17:05:56.109153Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-05-19T17:06:21.425Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Archer AX72 (SG) v1.0",
          "vendor": "TP-Link Systems Inc.",
          "versions": [
            {
              "lessThan": "1.4.6 Build 20260112 rel.66206",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "George Chen"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.\u0026nbsp;\u003cdiv\u003e\u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eAn authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options.\u0026nbsp; The exposed information is limited in scope and does not include sensitive system data.\u003c/div\u003e"
            }
          ],
          "value": "In the web management interface of Archer AX72 (SG) v1, the network diagnostic feature improperly handles invalid user input, resulting in limited exposure of diagnostic command usage information.\u00a0\n\n\nAn authenticated attacker with administrative privileges could exploit this issue to confirm the presence of the diagnostic utility and view its valid command-line syntax and options.\u00a0 The exposed information is limited in scope and does not include sensitive system data."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-54",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-54 Query System for Information"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "HIGH",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:H/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-209",
              "description": "CWE-209 Generation of error message containing sensitive information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-05-19T15:58:46.404Z",
        "orgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
        "shortName": "TPLink"
      },
      "references": [
        {
          "tags": [
            "patch"
          ],
          "url": "https://www.tp-link.com/sg/support/download/archer-ax72/#Firmware"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.tp-link.com/us/support/faq/5096/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Information Disclosure via Diagnostic Interface Due to Improper Input Validation on TP-Link\u0027s Archer AX72",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f23511db-6c3e-4e32-a477-6aa17d310630",
    "assignerShortName": "TPLink",
    "cveId": "CVE-2026-5511",
    "datePublished": "2026-05-19T15:58:46.404Z",
    "dateReserved": "2026-04-03T17:31:05.618Z",
    "dateUpdated": "2026-05-19T17:06:21.425Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}