Search

Find a vulnerability

Search criteria

    4 vulnerabilities found for AC500 V2 by ABB

    CVE-2025-7745 (GCVE-0-2025-7745)

    Vulnerability from nvd – Published: 2025-07-24 07:09 – Updated: 2025-07-24 13:17
    VLAI
    Title
    Modbus TCP buffer overread
    Summary
    Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-24 13:17 UTC
    CWE
    Impacted products
    Vendor Product Version
    ABB AC500 V2 Affected: 0 , ≤ 2.5.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7745",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-24T13:17:42.636529Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-24T13:17:47.983Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AC500 V2",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges and extends gratitude to Reid Wightman of Dragos Inc for responsibly disclosing the vulnerability and providing valuable input on product improvements"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Buffer Over-read vulnerability in ABB AC500 V2.\u003cp\u003eThis issue affects AC500 V2: through 2.5.2.\u003c/p\u003e"
                }
              ],
              "value": "Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-126",
                  "description": "CWE-126: Buffer Over-read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-24T11:57:52.418Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011432\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Modbus TCP buffer overread",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7745",
        "datePublished": "2025-07-24T07:09:11.906Z",
        "dateReserved": "2025-07-17T08:40:39.666Z",
        "dateUpdated": "2025-07-24T13:17:47.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-3192 (GCVE-0-2022-3192)

    Vulnerability from nvd – Published: 2023-03-31 16:13 – Updated: 2025-02-11 18:40
    VLAI
    Title
    Improper Check for Unusual or Exceptional Conditions
    Summary
    Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-11 18:39 UTC
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Impacted products
    Vendor Product Version
    ABB AC500 V2 Affected: 2.0.0 , < 2.8.6 (release)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:00:10.643Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-3192",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-11T18:39:53.320995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-11T18:40:07.850Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "collectionURL": "https://abb.com/plc",
              "defaultStatus": "unknown",
              "packageName": "PM5xx",
              "product": "AC500 V2",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.8.6",
                  "status": "affected",
                  "version": "2.0.0",
                  "versionType": "release"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "ABB thanks the following for working with us to help protect customers:  CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e"
                }
              ],
              "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-220",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-220 Client-Server Protocol Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-09-13T03:57:46.530Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": " Improper Check for Unusual or Exceptional Conditions",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eUse the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e"
                }
              ],
              "value": "Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2022-3192",
        "datePublished": "2023-03-31T16:13:13.149Z",
        "dateReserved": "2022-09-13T05:57:45.421Z",
        "dateUpdated": "2025-02-11T18:40:07.850Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2025-7745 (GCVE-0-2025-7745)

    Vulnerability from cvelistv5 – Published: 2025-07-24 07:09 – Updated: 2025-07-24 13:17
    VLAI
    Title
    Modbus TCP buffer overread
    Summary
    Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-07-24 13:17 UTC
    CWE
    Impacted products
    Vendor Product Version
    ABB AC500 V2 Affected: 0 , ≤ 2.5.2 (custom)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-7745",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-07-24T13:17:42.636529Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-07-24T13:17:47.983Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "AC500 V2",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThanOrEqual": "2.5.2",
                  "status": "affected",
                  "version": "0",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "ABB acknowledges and extends gratitude to Reid Wightman of Dragos Inc for responsibly disclosing the vulnerability and providing valuable input on product improvements"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Buffer Over-read vulnerability in ABB AC500 V2.\u003cp\u003eThis issue affects AC500 V2: through 2.5.2.\u003c/p\u003e"
                }
              ],
              "value": "Buffer Over-read vulnerability in ABB AC500 V2.This issue affects AC500 V2: through 2.5.2."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.8,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:N",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            },
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "PRESENT",
                "attackVector": "NETWORK",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "HIGH",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "LOW",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:L/SA:H",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-126",
                  "description": "CWE-126: Buffer Over-read",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-07-24T11:57:52.418Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011432\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Modbus TCP buffer overread",
          "x_generator": {
            "engine": "Vulnogram 0.2.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2025-7745",
        "datePublished": "2025-07-24T07:09:11.906Z",
        "dateReserved": "2025-07-17T08:40:39.666Z",
        "dateUpdated": "2025-07-24T13:17:47.983Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-3192 (GCVE-0-2022-3192)

    Vulnerability from cvelistv5 – Published: 2023-03-31 16:13 – Updated: 2025-02-11 18:40
    VLAI
    Title
    Improper Check for Unusual or Exceptional Conditions
    Summary
    Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator · CISA-ADP (v2.0.3)
    Decision recorded 2025-02-11 18:39 UTC
    CWE
    • CWE-754 - Improper Check for Unusual or Exceptional Conditions
    Impacted products
    Vendor Product Version
    ABB AC500 V2 Affected: 2.0.0 , < 2.8.6 (release)
    Create a notification for this product.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:00:10.643Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-3192",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-11T18:39:53.320995Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-11T18:40:07.850Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "collectionURL": "https://abb.com/plc",
              "defaultStatus": "unknown",
              "packageName": "PM5xx",
              "product": "AC500 V2",
              "vendor": "ABB",
              "versions": [
                {
                  "lessThan": "2.8.6",
                  "status": "affected",
                  "version": "2.0.0",
                  "versionType": "release"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "ABB thanks the following for working with us to help protect customers:  CVE-2022-3192: Parul Sindhwad and Dr. Faruk Kazi of CoE CNDS lab, VJTI, Mumbai (India) for reporting this vulnerability following coordinated disclosure."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.\u003cp\u003eThis issue affects AC500 V2: from 2.0.0 before 2.8.6.\u003c/p\u003e"
                }
              ],
              "value": "Improper Input Validation vulnerability in ABB AC500 V2 PM5xx allows Client-Server Protocol Manipulation.This issue affects AC500 V2: from 2.0.0 before 2.8.6.\n\n"
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-220",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-220 Client-Server Protocol Manipulation"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-754",
                  "description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-09-13T03:57:46.530Z",
            "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
            "shortName": "ABB"
          },
          "references": [
            {
              "url": "https://search.abb.com/library/Download.aspx?DocumentID=3ADR011162\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": " Improper Check for Unusual or Exceptional Conditions",
          "workarounds": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "\u003cdiv\u003eUse the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \u003cbr\u003e\u003c/div\u003e\u003cdiv\u003eThis protocol/port is not affected by the DoS impact of the vulnerability.\u003cbr\u003e\u003c/div\u003e"
                }
              ],
              "value": "Use the communication protocol \"Tcp/Ip\" instead of \"ABB Tcp/Ip Level 2\" (i.e. Port 1201 instead of 1200) for the connection between engineering software and PLC. \n\n\nThis protocol/port is not affected by the DoS impact of the vulnerability.\n\n\n"
            }
          ],
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "assignerShortName": "ABB",
        "cveId": "CVE-2022-3192",
        "datePublished": "2023-03-31T16:13:13.149Z",
        "dateReserved": "2022-09-13T05:57:45.421Z",
        "dateUpdated": "2025-02-11T18:40:07.850Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }