Search

Find a vulnerability

Search criteria

    2 vulnerabilities found for 752-8303/8000-002 Edge Controller by WAGO

    CVE-2022-3281 (GCVE-0-2022-3281)

    Vulnerability from nvd – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
    VLAI
    Title
    WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
    Summary
    WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-440 - Expected Behavior Violation
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-8217/xxx-xxx Series PFC100/PFC200 Affected: 03.04.10(16) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO Compact Controller CC100 Affected: 03.07.17(19) , ≤ 03.09.08(21) (custom)
    Create a notification for this product.
    WAGO 762-4xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-5xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-6xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-002 Edge Controller Affected: 03.06.09(18) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    Date Public
    2022-10-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:07:06.534Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-3281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-10T02:56:08.488527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-10T02:56:32.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "750-81xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-8217/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.04.10(16)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-82xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.09.08(21)",
                  "status": "affected",
                  "version": "03.07.17(19)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-4xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-5xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-6xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "752-8303/8000-002 Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.06.09(18)",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-10-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-440",
                  "description": "CWE-440 Expected Behavior Violation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-02T00:00:00.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
            }
          ],
          "source": {
            "advisory": "VDE-2022-042",
            "defect": [
              "CERT@VDE#64236"
            ],
            "discovery": "INTERNAL"
          },
          "title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
          "x_generator": {
            "engine": "vulnogram 0.1.0-rc1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-3281",
        "datePublished": "2022-10-17T08:20:12.389Z",
        "dateReserved": "2022-09-23T00:00:00.000Z",
        "dateUpdated": "2025-05-10T02:56:32.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }

    CVE-2022-3281 (GCVE-0-2022-3281)

    Vulnerability from cvelistv5 – Published: 2022-10-17 08:20 – Updated: 2025-05-10 02:56
    VLAI
    Title
    WAGO: multiple products - Loss of MAC-Address-Filtering after reboot
    Summary
    WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-440 - Expected Behavior Violation
    Assigner
    References
    Impacted products
    Vendor Product Version
    WAGO 750-81xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-8217/xxx-xxx Series PFC100/PFC200 Affected: 03.04.10(16) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO 750-82xx/xxx-xxx Series PFC100/PFC200 Affected: 03.01.07(13) , ≤ 03.10.08(22) (custom)
    Create a notification for this product.
    WAGO Compact Controller CC100 Affected: 03.07.17(19) , ≤ 03.09.08(21) (custom)
    Create a notification for this product.
    WAGO 762-4xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-5xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 762-6xxx Series Touch Panel 600 Affected: 03.01.07(13) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    WAGO 752-8303/8000-002 Edge Controller Affected: 03.06.09(18) , ≤ 03.10.09(22) (custom)
    Create a notification for this product.
    Date Public
    2022-10-17 00:00
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-03T01:07:06.534Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2022-3281",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-05-10T02:56:08.488527Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-05-10T02:56:32.932Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "750-81xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-8217/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.04.10(16)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "750-82xx/xxx-xxx Series PFC100/PFC200",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.08(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "Compact Controller CC100",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.09.08(21)",
                  "status": "affected",
                  "version": "03.07.17(19)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-4xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-5xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "762-6xxx Series Touch Panel 600",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.01.07(13)",
                  "versionType": "custom"
                }
              ]
            },
            {
              "product": "752-8303/8000-002 Edge Controller",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.10.09(22)",
                  "status": "affected",
                  "version": "03.06.09(18)",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "datePublic": "2022-10-17T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "WAGO Series PFC100/PFC200, Series Touch Panel 600, Compact Controller CC100 and Edge Controller in multiple versions are prone to a loss of MAC-Address-Filtering after reboot. This may allow an remote attacker to circumvent the reach the network that should be protected by the MAC address filter."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:N",
                "version": "3.1"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-440",
                  "description": "CWE-440 Expected Behavior Violation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2022-11-02T00:00:00.000Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2022-042/"
            }
          ],
          "source": {
            "advisory": "VDE-2022-042",
            "defect": [
              "CERT@VDE#64236"
            ],
            "discovery": "INTERNAL"
          },
          "title": "WAGO: multiple products - Loss of MAC-Address-Filtering after reboot",
          "x_generator": {
            "engine": "vulnogram 0.1.0-rc1"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2022-3281",
        "datePublished": "2022-10-17T08:20:12.389Z",
        "dateReserved": "2022-09-23T00:00:00.000Z",
        "dateUpdated": "2025-05-10T02:56:32.932Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }