Search
Find a vulnerability
Search criteria
4 vulnerabilities found for 6869i_firmware by mitel
CVE-2024-37569 (GCVE-0-2024-37569)
Vulnerability from nvd – Published: 2024-06-09 00:00 – Updated: 2024-08-02 03:57
VLAI
EPSS
VEX
Summary
An issue was discovered on Mitel 6869i through 4.5.0.41 and 5.x through 5.0.0.1018 devices. A command injection vulnerability exists in the hostname parameter taken in by the provis.html endpoint. The provis.html endpoint performs no sanitization on the hostname parameter (sent by an authenticated user), which is subsequently written to disk. During boot, the hostname parameter is executed as part of a series of shell commands. Attackers can achieve remote code execution in the root context by placing shell metacharacters in the hostname parameter.
Severity
8.3 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-10 12:43 UTC
CWE
- n/a
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| mitel | 6869i_firmware |
Affected:
4.5.0.41
Affected: 5.0.0.1018 cpe:2.3:a:mitel:6869i_firmware:4.5.0.41:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mitel:6869i_firmware:4.5.0.41:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "6869i_firmware",
"vendor": "mitel",
"versions": [
{
"status": "affected",
"version": "4.5.0.41"
},
{
"status": "affected",
"version": "5.0.0.1018"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37569",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-10T12:43:09.374978Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T12:46:21.387Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:57:39.561Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kwburns/CVE/tree/main/Mitel/5.0.0.1018#authenticated-remote-command-execution-provis"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kwburns/CVE/blob/main/Mitel/5.0.0.1018/code/exploit-provis.py"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.youtube.com/watch?v=I9TQqfP5qzM"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mitel 6869i through 4.5.0.41 and 5.x through 5.0.0.1018 devices. A command injection vulnerability exists in the hostname parameter taken in by the provis.html endpoint. The provis.html endpoint performs no sanitization on the hostname parameter (sent by an authenticated user), which is subsequently written to disk. During boot, the hostname parameter is executed as part of a series of shell commands. Attackers can achieve remote code execution in the root context by placing shell metacharacters in the hostname parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-09T19:38:03.567Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/kwburns/CVE/tree/main/Mitel/5.0.0.1018#authenticated-remote-command-execution-provis"
},
{
"url": "https://github.com/kwburns/CVE/blob/main/Mitel/5.0.0.1018/code/exploit-provis.py"
},
{
"url": "https://www.youtube.com/watch?v=I9TQqfP5qzM"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37569",
"datePublished": "2024-06-09T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2024-08-02T03:57:39.561Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18863 (GCVE-0-2019-18863)
Vulnerability from nvd – Published: 2020-03-02 17:52 – Updated: 2024-08-05 02:02
VLAI
EPSS
VEX
Summary
A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.mitel.com/support/security-advisories | x_refsource_MISC |
| https://www.mitel.com/support/security-advisories… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:02:39.895Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitel.com/support/security-advisories"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-02T17:52:37.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.mitel.com/support/security-advisories"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-18863",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitel.com/support/security-advisories",
"refsource": "MISC",
"url": "https://www.mitel.com/support/security-advisories"
},
{
"name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006",
"refsource": "CONFIRM",
"url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-18863",
"datePublished": "2020-03-02T17:52:37.000Z",
"dateReserved": "2019-11-11T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:02:39.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-37569 (GCVE-0-2024-37569)
Vulnerability from cvelistv5 – Published: 2024-06-09 00:00 – Updated: 2024-08-02 03:57
VLAI
EPSS
VEX
Summary
An issue was discovered on Mitel 6869i through 4.5.0.41 and 5.x through 5.0.0.1018 devices. A command injection vulnerability exists in the hostname parameter taken in by the provis.html endpoint. The provis.html endpoint performs no sanitization on the hostname parameter (sent by an authenticated user), which is subsequently written to disk. During boot, the hostname parameter is executed as part of a series of shell commands. Attackers can achieve remote code execution in the root context by placing shell metacharacters in the hostname parameter.
Severity
8.3 (High)
SSVC
Exploitation: poc
Automatable: no
Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-06-10 12:43 UTC
CWE
- n/a
- CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
References
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| mitel | 6869i_firmware |
Affected:
4.5.0.41
Affected: 5.0.0.1018 cpe:2.3:a:mitel:6869i_firmware:4.5.0.41:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:mitel:6869i_firmware:4.5.0.41:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "6869i_firmware",
"vendor": "mitel",
"versions": [
{
"status": "affected",
"version": "4.5.0.41"
},
{
"status": "affected",
"version": "5.0.0.1018"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2024-37569",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-06-10T12:43:09.374978Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-10T12:46:21.387Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T03:57:39.561Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kwburns/CVE/tree/main/Mitel/5.0.0.1018#authenticated-remote-command-execution-provis"
},
{
"tags": [
"x_transferred"
],
"url": "https://github.com/kwburns/CVE/blob/main/Mitel/5.0.0.1018/code/exploit-provis.py"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.youtube.com/watch?v=I9TQqfP5qzM"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mitel 6869i through 4.5.0.41 and 5.x through 5.0.0.1018 devices. A command injection vulnerability exists in the hostname parameter taken in by the provis.html endpoint. The provis.html endpoint performs no sanitization on the hostname parameter (sent by an authenticated user), which is subsequently written to disk. During boot, the hostname parameter is executed as part of a series of shell commands. Attackers can achieve remote code execution in the root context by placing shell metacharacters in the hostname parameter."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-06-09T19:38:03.567Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://github.com/kwburns/CVE/tree/main/Mitel/5.0.0.1018#authenticated-remote-command-execution-provis"
},
{
"url": "https://github.com/kwburns/CVE/blob/main/Mitel/5.0.0.1018/code/exploit-provis.py"
},
{
"url": "https://www.youtube.com/watch?v=I9TQqfP5qzM"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2024-37569",
"datePublished": "2024-06-09T00:00:00.000Z",
"dateReserved": "2024-06-09T00:00:00.000Z",
"dateUpdated": "2024-08-02T03:57:39.561Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-18863 (GCVE-0-2019-18863)
Vulnerability from cvelistv5 – Published: 2020-03-02 17:52 – Updated: 2024-08-05 02:02
VLAI
EPSS
VEX
Summary
A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information.
Severity
No CVSS data available.
CWE
- n/a
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.mitel.com/support/security-advisories | x_refsource_MISC |
| https://www.mitel.com/support/security-advisories… | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T02:02:39.895Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.mitel.com/support/security-advisories"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-03-02T17:52:37.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.mitel.com/support/security-advisories"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2019-18863",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A key length vulnerability in the implementation of the SRTP 128-bit key on Mitel 6800 and 6900 SIP series phones, versions 5.1.0.2051 SP2 and earlier, could allow an attacker to launch a man-in-the-middle attack when SRTP is used in a call. A successful exploit may allow the attacker to intercept sensitive information."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.mitel.com/support/security-advisories",
"refsource": "MISC",
"url": "https://www.mitel.com/support/security-advisories"
},
{
"name": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006",
"refsource": "CONFIRM",
"url": "https://www.mitel.com/support/security-advisories/mitel-product-security-advisory-19-0006"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2019-18863",
"datePublished": "2020-03-02T17:52:37.000Z",
"dateReserved": "2019-11-11T00:00:00.000Z",
"dateUpdated": "2024-08-05T02:02:39.895Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}