Find a vulnerability
Search criteria
10 vulnerabilities found for 4G300 by Tenda
VAR-202404-0345
Vulnerability from variot - Updated: 2025-06-19 23:37A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda 4G300 is a portable wireless router, mainly for users who need mobile Internet access. No detailed vulnerability details are provided at present
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0345",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "4g300",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.01.42"
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "4g300 firmware 1.01.42"
},
{
"model": "4g300",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12696"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"cve": "CVE-2024-4170",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-4170",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-017113",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-12696",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-4170",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-017113",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-4170",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-4170",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-017113",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-12696",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12696"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda 4G300 1.01.42. It has been rated as critical. This issue affects the function sub_429A30. The manipulation of the argument list1 leads to stack-based buffer overflow. The attack may be initiated remotely. The identifier VDB-261989 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda 4G300 is a portable wireless router, mainly for users who need mobile Internet access. No detailed vulnerability details are provided at present",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-4170"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "CNVD",
"id": "CNVD-2025-12696"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-4170",
"trust": 3.2
},
{
"db": "VULDB",
"id": "261989",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017113",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-12696",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12696"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"id": "VAR-202404-0345",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12696"
}
],
"trust": 1.5
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12696"
}
]
},
"last_update_date": "2025-06-19T23:37:18.015000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/g3/4g300/sub_429a30.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.261989"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.318991"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.261989"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-4170"
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-12696"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-12696"
},
{
"date": "2025-01-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"date": "2024-04-25T13:15:51.993000",
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-12696"
},
{
"date": "2025-01-22T01:37:00",
"db": "JVNDB",
"id": "JVNDB-2024-017113"
},
{
"date": "2025-01-21T14:15:32.487000",
"db": "NVD",
"id": "CVE-2024-4170"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a04g300\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017113"
}
],
"trust": 0.8
}
}
VAR-202404-0211
Vulnerability from variot - Updated: 2025-06-19 23:33A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda 4G300 is a portable wireless router, mainly for users who need mobile Internet access.
Tenda 4G300 has a buffer overflow vulnerability, which is caused by incorrect operation of parameters year/month/day/hour/minute/second. No detailed vulnerability details are provided at present
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0211",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "4g300",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.01.42"
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "4g300 firmware 1.01.42"
},
{
"model": "4g300",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"cve": "CVE-2024-4167",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-4167",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-017134",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2025-12695",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-4167",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-017134",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-4167",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-4167",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-017134",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2025-12695",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda 4G300 1.01.42 and classified as critical. Affected by this issue is the function sub_422AA4. The manipulation of the argument year/month/day/hour/minute/second leads to stack-based buffer overflow. The attack may be launched remotely. VDB-261986 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda 4G300 is a portable wireless router, mainly for users who need mobile Internet access. \n\nTenda 4G300 has a buffer overflow vulnerability, which is caused by incorrect operation of parameters year/month/day/hour/minute/second. No detailed vulnerability details are provided at present",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-4167"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "CNVD",
"id": "CNVD-2025-12695"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-4167",
"trust": 3.2
},
{
"db": "VULDB",
"id": "261986",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2025-12695",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"id": "VAR-202404-0211",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
}
],
"trust": 1.5
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
}
]
},
"last_update_date": "2025-06-19T23:33:58.441000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/g3/4g300/sub_422aa4.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.261986"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.318983"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-4167"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.261986"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"date": "2025-01-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"date": "2024-04-25T12:15:07.990000",
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2025-06-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2025-12695"
},
{
"date": "2025-01-22T05:42:00",
"db": "JVNDB",
"id": "JVNDB-2024-017134"
},
{
"date": "2025-01-21T14:41:18.070000",
"db": "NVD",
"id": "CVE-2024-4167"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a04g300\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017134"
}
],
"trust": 0.8
}
}
VAR-202404-0322
Vulnerability from variot - Updated: 2025-01-25 22:54A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0322",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "4g300",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.01.42"
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "4g300 firmware 1.01.42"
},
{
"model": "4g300",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"cve": "CVE-2024-4169",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-4169",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-017153",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-23304",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-4169",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-017153",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-4169",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-4169",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-017153",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-23304",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda 4G300 1.01.42. It has been declared as critical. This vulnerability affects the function sub_42775C/sub_4279CC. The manipulation of the argument page leads to stack-based buffer overflow. The attack can be initiated remotely. The identifier of this vulnerability is VDB-261988. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-4169"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "CNVD",
"id": "CNVD-2024-23304"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-4169",
"trust": 3.2
},
{
"db": "VULDB",
"id": "261988",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-23304",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"id": "VAR-202404-0322",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
}
],
"trust": 1.5
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
}
]
},
"last_update_date": "2025-01-25T22:54:53.383000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/g3/4g300/sub_42775c.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.261988"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.318988"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-4169"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.261988"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-15T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"date": "2025-01-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"date": "2024-04-25T13:15:51.780000",
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-20T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23304"
},
{
"date": "2025-01-22T06:37:00",
"db": "JVNDB",
"id": "JVNDB-2024-017153"
},
{
"date": "2025-01-21T14:20:59.187000",
"db": "NVD",
"id": "CVE-2024-4169"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a04g300\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017153"
}
],
"trust": 0.8
}
}
VAR-202404-0270
Vulnerability from variot - Updated: 2025-01-25 22:38A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the upfilen parameter of the sub_4260F0 function to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0270",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "4g300",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.01.42"
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "4g300 firmware 1.01.42"
},
{
"model": "4g300",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"cve": "CVE-2024-4168",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-4168",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-017196",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-23283",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-4168",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-017196",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-4168",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-4168",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-017196",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-23283",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability was found in Tenda 4G300 1.01.42. It has been classified as critical. This affects the function sub_4260F0. The manipulation of the argument upfilen leads to stack-based buffer overflow. It is possible to initiate the attack remotely. The associated identifier of this vulnerability is VDB-261987. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The vulnerability is caused by the failure of the upfilen parameter of the sub_4260F0 function to correctly verify the length of the input data. Remote attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service attack",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-4168"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "CNVD",
"id": "CNVD-2024-23283"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-4168",
"trust": 3.2
},
{
"db": "VULDB",
"id": "261987",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-23283",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"id": "VAR-202404-0270",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
}
],
"trust": 1.5
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
}
]
},
"last_update_date": "2025-01-25T22:38:21.835000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/g3/4g300/sub_4260f0.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.261987"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.318987"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-4168"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.261987"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-11T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"date": "2025-01-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"date": "2024-04-25T12:15:08.217000",
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-17T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-23283"
},
{
"date": "2025-01-22T07:43:00",
"db": "JVNDB",
"id": "JVNDB-2024-017196"
},
{
"date": "2025-01-21T14:34:05.903000",
"db": "NVD",
"id": "CVE-2024-4168"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a04g300\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017196"
}
],
"trust": 0.8
}
}
VAR-202404-0289
Vulnerability from variot - Updated: 2025-01-25 22:29A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"configurations": {
"@id": "https://www.variotdbs.pl/ref/configurations"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202404-0289",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "4g300",
"scope": "eq",
"trust": 1.6,
"vendor": "tenda",
"version": "1.01.42"
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "4g300 firmware 1.01.42"
},
{
"model": "4g300",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"cve": "CVE-2024-4166",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "cna@vuldb.com",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CVE-2024-4166",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 1.0,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"acInsufInfo": null,
"accessComplexity": "Low",
"accessVector": "Network",
"authentication": "Single",
"author": "OTHER",
"availabilityImpact": "Complete",
"baseScore": 9.0,
"confidentialityImpact": "Complete",
"exploitabilityScore": null,
"id": "JVNDB-2024-017182",
"impactScore": null,
"integrityImpact": "Complete",
"obtainAllPrivilege": null,
"obtainOtherPrivilege": null,
"obtainUserPrivilege": null,
"severity": "High",
"trust": 0.8,
"userInteractionRequired": null,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
},
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 9.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 8.0,
"id": "CNVD-2024-24955",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:S/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "cna@vuldb.com",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 2.8,
"id": "CVE-2024-4166",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"trust": 2.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 8.8,
"baseSeverity": "High",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "JVNDB-2024-017182",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "Low",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "cna@vuldb.com",
"id": "CVE-2024-4166",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "nvd@nist.gov",
"id": "CVE-2024-4166",
"trust": 1.0,
"value": "HIGH"
},
{
"author": "OTHER",
"id": "JVNDB-2024-017182",
"trust": 0.8,
"value": "High"
},
{
"author": "CNVD",
"id": "CNVD-2024-24955",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "A vulnerability has been found in Tenda 4G300 1.01.42 and classified as critical. Affected by this vulnerability is the function sub_41E858. The manipulation of the argument GO/page leads to stack-based buffer overflow. The attack can be launched remotely. The identifier VDB-261985 was assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way. Shenzhen Tenda Technology Co.,Ltd. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. No detailed vulnerability details are currently provided",
"sources": [
{
"db": "NVD",
"id": "CVE-2024-4166"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "CNVD",
"id": "CNVD-2024-24955"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2024-4166",
"trust": 3.2
},
{
"db": "VULDB",
"id": "261985",
"trust": 1.8
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2024-24955",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"id": "VAR-202404-0289",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
}
],
"trust": 1.5
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
}
]
},
"last_update_date": "2025-01-25T22:29:31.111000Z",
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-121",
"trust": 1.0
},
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Stack-based buffer overflow (CWE-121) [ others ]",
"trust": 0.8
},
{
"problemtype": " Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.8,
"url": "https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/g3/4g300/sub_41e858_go.md"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?id.261985"
},
{
"trust": 1.8,
"url": "https://vuldb.com/?submit.318981"
},
{
"trust": 1.4,
"url": "https://nvd.nist.gov/vuln/detail/cve-2024-4166"
},
{
"trust": 1.0,
"url": "https://vuldb.com/?ctiid.261985"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-30T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"date": "2025-01-22T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"date": "2024-04-25T12:15:07.770000",
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2024-05-30T00:00:00",
"db": "CNVD",
"id": "CNVD-2024-24955"
},
{
"date": "2025-01-22T07:35:00",
"db": "JVNDB",
"id": "JVNDB-2024-017182"
},
{
"date": "2025-01-21T14:45:35.713000",
"db": "NVD",
"id": "CVE-2024-4166"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a04g300\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2024-017182"
}
],
"trust": 0.8
}
}
VAR-202308-2283
Vulnerability from variot - Updated: 2024-08-14 15:36Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state.
Tenda 4G300 has a buffer overflow vulnerability. Attackers can use this vulnerability to set page fields in requests to launch denial of service attacks or remote code execution attacks
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202308-2283",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "4g300",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.01.42"
},
{
"model": "4g300",
"scope": null,
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": null
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.8,
"vendor": "tenda",
"version": "4g300 firmware 1.01.42"
},
{
"model": "4g300",
"scope": "eq",
"trust": 0.6,
"vendor": "tenda",
"version": "v1.01.42"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"cve": "CVE-2023-38929",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [
{
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"author": "CNVD",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"exploitabilityScore": 10.0,
"id": "CNVD-2023-62955",
"impactScore": 10.0,
"integrityImpact": "COMPLETE",
"severity": "HIGH",
"trust": 0.6,
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
}
],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-38929",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
{
"attackComplexity": "Low",
"attackVector": "Network",
"author": "NVD",
"availabilityImpact": "High",
"baseScore": 9.8,
"baseSeverity": "Critical",
"confidentialityImpact": "High",
"exploitabilityScore": null,
"id": "CVE-2023-38929",
"impactScore": null,
"integrityImpact": "High",
"privilegesRequired": "None",
"scope": "Unchanged",
"trust": 0.8,
"userInteraction": "None",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-38929",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "NVD",
"id": "CVE-2023-38929",
"trust": 0.8,
"value": "Critical"
},
{
"author": "CNVD",
"id": "CNVD-2023-62955",
"trust": 0.6,
"value": "HIGH"
}
]
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda 4G300 v1.01.42 was discovered to contain a stack overflow via the page parameter at /VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of 4g300 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. \n\r\n\r\nTenda 4G300 has a buffer overflow vulnerability. Attackers can use this vulnerability to set page fields in requests to launch denial of service attacks or remote code execution attacks",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-38929"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "CNVD",
"id": "CNVD-2023-62955"
}
],
"trust": 2.16
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-38929",
"trust": 3.2
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094",
"trust": 0.8
},
{
"db": "CNVD",
"id": "CNVD-2023-62955",
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"id": "VAR-202308-2283",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
}
],
"trust": 1.5
},
"iot_taxonomy": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot_taxonomy#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"category": [
"Network device"
],
"sub_category": null,
"trust": 0.6
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
}
]
},
"last_update_date": "2024-08-14T15:36:48.189000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Patch for Tenda 4G300 buffer overflow vulnerability",
"trust": 0.6,
"url": "https://www.cnvd.org.cn/patchInfo/show/451896"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
},
{
"problemtype": "Out-of-bounds writing (CWE-787) [NVD evaluation ]",
"trust": 0.8
}
],
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 2.4,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/virtualser/readme.md"
},
{
"trust": 0.8,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-38929"
}
],
"sources": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-08-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"date": "2024-01-18T00:00:00",
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"date": "2023-08-07T19:15:10.843000",
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-08-14T00:00:00",
"db": "CNVD",
"id": "CNVD-2023-62955"
},
{
"date": "2024-01-18T06:42:00",
"db": "JVNDB",
"id": "JVNDB-2023-021094"
},
{
"date": "2023-08-09T18:05:18.777000",
"db": "NVD",
"id": "CVE-2023-38929"
}
]
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Shenzhen\u00a0Tenda\u00a0Technology\u00a0Co.,Ltd.\u00a0 of \u00a04g300\u00a0 Out-of-bounds write vulnerability in firmware",
"sources": [
{
"db": "JVNDB",
"id": "JVNDB-2023-021094"
}
],
"trust": 0.8
}
}
VAR-202307-1287
Vulnerability from variot - Updated: 2024-08-14 15:31Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1287",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "4g300",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"cve": "CVE-2023-37718",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37718",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37718",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1262",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
},
{
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeClientFilter",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37718"
},
{
"db": "VULMON",
"id": "CVE-2023-37718"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37718",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1262",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37718",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37718"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
},
{
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"id": "VAR-202307-1287",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7888889
},
"last_update_date": "2024-08-14T15:31:58.849000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda F1202 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247159"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromsafeclientfilter/report.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37718"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37718/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37718"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
},
{
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37718"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
},
{
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37718"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1262"
},
{
"date": "2023-07-14T00:15:09.523000",
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37718"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1262"
},
{
"date": "2023-07-21T14:32:08.327000",
"db": "NVD",
"id": "CVE-2023-37718"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1262"
}
],
"trust": 0.6
}
}
VAR-202307-1202
Vulnerability from variot - Updated: 2024-08-14 15:15Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1202",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "4g300",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"cve": "CVE-2023-37722",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37722",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37722",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1276",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
},
{
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeUrlFilter",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37722"
},
{
"db": "VULMON",
"id": "CVE-2023-37722"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37722",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1276",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37722",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37722"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
},
{
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"id": "VAR-202307-1202",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7888889
},
"last_update_date": "2024-08-14T15:15:55.510000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda F1202 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247162"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromsafeurlfilter/report.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37722"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37722/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37722"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
},
{
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37722"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
},
{
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37722"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1276"
},
{
"date": "2023-07-14T00:15:09.660000",
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37722"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1276"
},
{
"date": "2023-07-21T14:26:45.147000",
"db": "NVD",
"id": "CVE-2023-37722"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1276"
}
],
"trust": 0.6
}
}
VAR-202307-1305
Vulnerability from variot - Updated: 2024-08-14 14:43Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1305",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "4g300",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
},
{
"model": "pa202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
},
{
"model": "pw201a",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"cve": "CVE-2023-37721",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37721",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37721",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1264",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
},
{
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromSafeMacFilter",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37721"
},
{
"db": "VULMON",
"id": "CVE-2023-37721"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37721",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1264",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37721",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37721"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
},
{
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"id": "VAR-202307-1305",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7888889
},
"last_update_date": "2024-08-14T14:43:08.587000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda F1202 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247160"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromsafemacfilter/report.md"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37721"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37721/"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37721"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
},
{
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37721"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
},
{
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37721"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1264"
},
{
"date": "2023-07-14T00:15:09.617000",
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37721"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1264"
},
{
"date": "2023-07-21T14:26:31.143000",
"db": "NVD",
"id": "CVE-2023-37721"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1264"
}
],
"trust": 0.6
}
}
VAR-202307-1326
Vulnerability from variot - Updated: 2024-08-14 14:43Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting
Show details on source website{
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/VARIoTentry#",
"affected_products": {
"@id": "https://www.variotdbs.pl/ref/affected_products"
},
"credits": {
"@id": "https://www.variotdbs.pl/ref/credits"
},
"cvss": {
"@id": "https://www.variotdbs.pl/ref/cvss/"
},
"description": {
"@id": "https://www.variotdbs.pl/ref/description/"
},
"exploit_availability": {
"@id": "https://www.variotdbs.pl/ref/exploit_availability/"
},
"external_ids": {
"@id": "https://www.variotdbs.pl/ref/external_ids/"
},
"iot": {
"@id": "https://www.variotdbs.pl/ref/iot/"
},
"iot_taxonomy": {
"@id": "https://www.variotdbs.pl/ref/iot_taxonomy/"
},
"patch": {
"@id": "https://www.variotdbs.pl/ref/patch/"
},
"problemtype_data": {
"@id": "https://www.variotdbs.pl/ref/problemtype_data/"
},
"references": {
"@id": "https://www.variotdbs.pl/ref/references/"
},
"sources": {
"@id": "https://www.variotdbs.pl/ref/sources/"
},
"sources_release_date": {
"@id": "https://www.variotdbs.pl/ref/sources_release_date/"
},
"sources_update_date": {
"@id": "https://www.variotdbs.pl/ref/sources_update_date/"
},
"threat_type": {
"@id": "https://www.variotdbs.pl/ref/threat_type/"
},
"title": {
"@id": "https://www.variotdbs.pl/ref/title/"
},
"type": {
"@id": "https://www.variotdbs.pl/ref/type/"
}
},
"@id": "https://www.variotdbs.pl/vuln/VAR-202307-1326",
"affected_products": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/affected_products#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.0br"
},
{
"model": "f1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.20\\(408\\)"
},
{
"model": "4g300",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
},
{
"model": "pa202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
},
{
"model": "pw201a",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": null
},
{
"model": "fh1202",
"scope": "eq",
"trust": 1.0,
"vendor": "tenda",
"version": "1.2.0.19_en"
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"cve": "CVE-2023-37723",
"cvss": {
"@context": {
"cvssV2": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV2#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV2"
},
"cvssV3": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/cvss/cvssV3#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/cvssV3/"
},
"severity": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/cvss/severity#"
},
"@id": "https://www.variotdbs.pl/ref/cvss/severity"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
},
"@id": "https://www.variotdbs.pl/ref/sources"
}
},
"data": [
{
"cvssV2": [],
"cvssV3": [
{
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"author": "nvd@nist.gov",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"exploitabilityScore": 3.9,
"id": "CVE-2023-37723",
"impactScore": 5.9,
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"trust": 1.0,
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
],
"severity": [
{
"author": "nvd@nist.gov",
"id": "CVE-2023-37723",
"trust": 1.0,
"value": "CRITICAL"
},
{
"author": "CNNVD",
"id": "CNNVD-202307-1283",
"trust": 0.6,
"value": "CRITICAL"
}
]
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
},
{
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"description": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/description#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 V1.0BR_V1.2.0.20(408), FH1202_V1.2.0.19_EN were discovered to contain a stack overflow in the page parameter in the function fromqossetting",
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37723"
},
{
"db": "VULMON",
"id": "CVE-2023-37723"
}
],
"trust": 0.99
},
"external_ids": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/external_ids#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"db": "NVD",
"id": "CVE-2023-37723",
"trust": 1.7
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1283",
"trust": 0.6
},
{
"db": "VULMON",
"id": "CVE-2023-37723",
"trust": 0.1
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37723"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
},
{
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"id": "VAR-202307-1326",
"iot": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/iot#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": true,
"sources": [
{
"db": "VARIoT devices database",
"id": null
}
],
"trust": 0.7888889
},
"last_update_date": "2024-08-14T14:43:08.567000Z",
"patch": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/patch#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"title": "Tenda F1202 Buffer error vulnerability fix",
"trust": 0.6,
"url": "http://123.124.177.30/web/xxk/bdxqById.tag?id=247164"
}
],
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
}
]
},
"problemtype_data": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/problemtype_data#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"problemtype": "CWE-787",
"trust": 1.0
}
],
"sources": [
{
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"references": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/references#",
"data": {
"@container": "@list"
},
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": [
{
"trust": 1.7,
"url": "https://github.com/firmrec/iot-vulns/blob/main/tenda/fromqossetting/report.md"
},
{
"trust": 0.6,
"url": "https://cxsecurity.com/cveshow/cve-2023-37723/"
},
{
"trust": 0.6,
"url": "https://nvd.nist.gov/vuln/detail/cve-2023-37723"
},
{
"trust": 0.1,
"url": "https://nvd.nist.gov"
}
],
"sources": [
{
"db": "VULMON",
"id": "CVE-2023-37723"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
},
{
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"sources": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#",
"data": {
"@container": "@list"
}
},
"data": [
{
"db": "VULMON",
"id": "CVE-2023-37723"
},
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
},
{
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"sources_release_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_release_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37723"
},
{
"date": "2023-07-13T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1283"
},
{
"date": "2023-07-14T00:15:09.707000",
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"sources_update_date": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources_update_date#",
"data": {
"@container": "@list"
}
},
"data": [
{
"date": "2023-07-14T00:00:00",
"db": "VULMON",
"id": "CVE-2023-37723"
},
{
"date": "2023-07-24T00:00:00",
"db": "CNNVD",
"id": "CNNVD-202307-1283"
},
{
"date": "2023-07-21T14:26:54.460000",
"db": "NVD",
"id": "CVE-2023-37723"
}
]
},
"threat_type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/threat_type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "remote",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
}
],
"trust": 0.6
},
"title": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/title#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "Tenda F1202 Buffer error vulnerability",
"sources": [
{
"db": "CNNVD",
"id": "CNNVD-202307-1283"
}
],
"trust": 0.6
},
"type": {
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/type#",
"sources": {
"@container": "@list",
"@context": {
"@vocab": "https://www.variotdbs.pl/ref/sources#"
}
}
},
"data": "buffer error",
"sources": [
{
"db": "CNNVD",