Search

Find a vulnerability

Search criteria

    8 vulnerabilities found for 300Mbps Wireless Router F3 and N300 Easy Setup Router by Tenda

    CVE-2026-22082 (GCVE-0-2026-22082)

    Vulnerability from nvd – Published: 2026-01-09 11:24 – Updated: 2026-01-09 16:26
    VLAI
    Title
    Insecure Session ID Management Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission. Successful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22082",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:25:53.798612Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:26:14.019Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\u003cbr\u003e  \u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\n  \nSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-384",
                  "description": "CWE-384 Session Fixation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:24:54.375Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Insecure Session ID Management Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22082",
        "datePublished": "2026-01-09T11:24:54.375Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T16:26:14.019Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22081 (GCVE-0-2026-22081)

    Vulnerability from nvd – Published: 2026-01-09 11:16 – Updated: 2026-01-09 16:44
    VLAI
    Title
    Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection. Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1004 - - Sensitive Cookie Without HttpOnly Flag
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22081",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:44:27.653040Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:44:56.131Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1004",
                  "description": "CWE-1004 - Sensitive Cookie Without HttpOnly Flag",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:16:21.780Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22081",
        "datePublished": "2026-01-09T11:16:21.780Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T16:44:56.131Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22080 (GCVE-0-2026-22080)

    Vulnerability from nvd – Published: 2026-01-09 11:05 – Updated: 2026-01-09 15:12
    VLAI
    Title
    Insecure Transmission Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials. Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22080",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T15:12:38.102200Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T15:12:48.077Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-117",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-117 Interception"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:26:07.261Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Insecure Transmission Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22080",
        "datePublished": "2026-01-09T11:05:07.368Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T15:12:48.077Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22079 (GCVE-0-2026-22079)

    Vulnerability from nvd – Published: 2026-01-09 11:02 – Updated: 2026-01-09 15:15
    VLAI
    Title
    Cleartext Transmission Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext. Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T15:15:16.081528Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T15:15:27.815Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-117",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-117 Interception"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:25:36.253Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Cleartext Transmission Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22079",
        "datePublished": "2026-01-09T11:02:50.926Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T15:15:27.815Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22082 (GCVE-0-2026-22082)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:24 – Updated: 2026-01-09 16:26
    VLAI
    Title
    Insecure Session ID Management Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission. Successful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22082",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:25:53.798612Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:26:14.019Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\u003cbr\u003e  \u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\n  \nSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-384",
                  "description": "CWE-384 Session Fixation",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:24:54.375Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Insecure Session ID Management Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22082",
        "datePublished": "2026-01-09T11:24:54.375Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T16:26:14.019Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22081 (GCVE-0-2026-22081)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:16 – Updated: 2026-01-09 16:44
    VLAI
    Title
    Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection. Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.
    SSVC
    Exploitation: none Automatable: yes Technical Impact: partial
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-1004 - - Sensitive Cookie Without HttpOnly Flag
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22081",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T16:44:27.653040Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T16:44:56.131Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "baseScore": 8.8,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "LOW",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "LOW",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1004",
                  "description": "CWE-1004 - Sensitive Cookie Without HttpOnly Flag",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:16:21.780Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22081",
        "datePublished": "2026-01-09T11:16:21.780Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T16:44:56.131Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22080 (GCVE-0-2026-22080)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:05 – Updated: 2026-01-09 15:12
    VLAI
    Title
    Insecure Transmission Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials. Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22080",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T15:12:38.102200Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T15:12:48.077Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-117",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-117 Interception"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:26:07.261Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Insecure Transmission Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22080",
        "datePublished": "2026-01-09T11:05:07.368Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T15:12:48.077Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }

    CVE-2026-22079 (GCVE-0-2026-22079)

    Vulnerability from cvelistv5 – Published: 2026-01-09 11:02 – Updated: 2026-01-09 15:15
    VLAI
    Title
    Cleartext Transmission Vulnerability in Tenda Wireless Routers
    Summary
    This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext. Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
    SSVC
    Exploitation: none Automatable: no Technical Impact: total
    CISA Coordinator (v2.0.3)
    CWE
    • CWE-319 - Cleartext Transmission of Sensitive Information
    Assigner
    References
    Impacted products
    Vendor Product Version
    Tenda 300Mbps Wireless Router F3 and N300 Easy Setup Router Affected: F3 v3.0 Firmware V12.01.01.41
    Affected: F3 v3.0 Firmware V12.01.01.42
    Affected: F3 v3.0 Firmware V12.01.01.48
    Affected: F3 v3.0 Firmware V12.01.01.52
    Affected: F3 v3.0 Firmware V12.01.01.55
    Affected: F3 v4.0 Firmware V03.03.01.40
    Create a notification for this product.
    Credits
    This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
    Show details on NVD website

    {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2026-22079",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-09T15:15:16.081528Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-01-09T15:15:27.815Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
              "vendor": "Tenda",
              "versions": [
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.41"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.42"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.48"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.52"
                },
                {
                  "status": "affected",
                  "version": "F3 v3.0 Firmware V12.01.01.55"
                },
                {
                  "status": "affected",
                  "version": "F3 v4.0 Firmware V03.03.01.40"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
                }
              ],
              "value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-117",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-117 Interception"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "ADJACENT",
                "baseScore": 8.7,
                "baseSeverity": "HIGH",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "HIGH",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "HIGH",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-319",
                  "description": "CWE-319 Cleartext Transmission of Sensitive Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-09T11:25:36.253Z",
            "orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
            "shortName": "CERT-In"
          },
          "references": [
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
                }
              ],
              "value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "Cleartext Transmission Vulnerability in Tenda Wireless Routers",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
        "assignerShortName": "CERT-In",
        "cveId": "CVE-2026-22079",
        "datePublished": "2026-01-09T11:02:50.926Z",
        "dateReserved": "2026-01-06T07:52:50.901Z",
        "dateUpdated": "2026-01-09T15:15:27.815Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }