Search criteria
8 vulnerabilities found for 300Mbps Wireless Router F3 and N300 Easy Setup Router by Tenda
CVE-2026-22082 (GCVE-0-2026-22082)
Vulnerability from nvd – Published: 2026-01-09 11:24 – Updated: 2026-01-09 16:26
VLAI?
Title
Insecure Session ID Management Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.
Successful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.
Severity ?
CWE
- CWE-384 - Session Fixation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22082",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T16:25:53.798612Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T16:26:14.019Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\u003cbr\u003e \u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\n \nSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384 Session Fixation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:24:54.375Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insecure Session ID Management Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22082",
"datePublished": "2026-01-09T11:24:54.375Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T16:26:14.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22081 (GCVE-0-2026-22081)
Vulnerability from nvd – Published: 2026-01-09 11:16 – Updated: 2026-01-09 16:44
VLAI?
Title
Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.
Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.
Severity ?
CWE
- CWE-1004 - - Sensitive Cookie Without HttpOnly Flag
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22081",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T16:44:27.653040Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T16:44:56.131Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1004",
"description": "CWE-1004 - Sensitive Cookie Without HttpOnly Flag",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:16:21.780Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22081",
"datePublished": "2026-01-09T11:16:21.780Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T16:44:56.131Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22080 (GCVE-0-2026-22080)
Vulnerability from nvd – Published: 2026-01-09 11:05 – Updated: 2026-01-09 15:12
VLAI?
Title
Insecure Transmission Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.
Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
Severity ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22080",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T15:12:38.102200Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T15:12:48.077Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
}
],
"impacts": [
{
"capecId": "CAPEC-117",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-117 Interception"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:26:07.261Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insecure Transmission Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22080",
"datePublished": "2026-01-09T11:05:07.368Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T15:12:48.077Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22079 (GCVE-0-2026-22079)
Vulnerability from nvd – Published: 2026-01-09 11:02 – Updated: 2026-01-09 15:15
VLAI?
Title
Cleartext Transmission Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.
Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
Severity ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22079",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T15:15:16.081528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T15:15:27.815Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
}
],
"impacts": [
{
"capecId": "CAPEC-117",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-117 Interception"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:25:36.253Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cleartext Transmission Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22079",
"datePublished": "2026-01-09T11:02:50.926Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T15:15:27.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22082 (GCVE-0-2026-22082)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:24 – Updated: 2026-01-09 16:26
VLAI?
Title
Insecure Session ID Management Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.
Successful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.
Severity ?
CWE
- CWE-384 - Session Fixation
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22082",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T16:25:53.798612Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T16:26:14.019Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\u003cbr\u003e \u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the use of login credentials as the session ID through its web-based administrative interface. A remote attacker could exploit this vulnerability by intercepting network traffic and capturing the session ID during insecure transmission.\n \nSuccessful exploitation of this vulnerability could allow the attacker to hijack an authenticated session and compromise sensitive configuration information on the targeted device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384 Session Fixation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:24:54.375Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insecure Session ID Management Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22082",
"datePublished": "2026-01-09T11:24:54.375Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T16:26:14.019Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22081 (GCVE-0-2026-22081)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:16 – Updated: 2026-01-09 16:44
VLAI?
Title
Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.
Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.
Severity ?
CWE
- CWE-1004 - - Sensitive Cookie Without HttpOnly Flag
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22081",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T16:44:27.653040Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T16:44:56.131Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the missing HTTPOnly flag for session cookies associated with the web-based administrative interface. A remote at-tacker could exploit this vulnerability by capturing session cookies transmitted over an insecure HTTP connection.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unau-thorized access to the targeted device."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "LOW",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1004",
"description": "CWE-1004 - Sensitive Cookie Without HttpOnly Flag",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:16:21.780Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cookie without HTTPOnly Flag Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22081",
"datePublished": "2026-01-09T11:16:21.780Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T16:44:56.131Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22080 (GCVE-0-2026-22080)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:05 – Updated: 2026-01-09 15:12
VLAI?
Title
Insecure Transmission Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.
Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
Severity ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22080",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T15:12:38.102200Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T15:12:48.077Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the transmission of credentials encoded using reversible Base64 encoding through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the Base64-encoded credentials.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
}
],
"impacts": [
{
"capecId": "CAPEC-117",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-117 Interception"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:26:07.261Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Insecure Transmission Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22080",
"datePublished": "2026-01-09T11:05:07.368Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T15:12:48.077Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2026-22079 (GCVE-0-2026-22079)
Vulnerability from cvelistv5 – Published: 2026-01-09 11:02 – Updated: 2026-01-09 15:15
VLAI?
Title
Cleartext Transmission Vulnerability in Tenda Wireless Routers
Summary
This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.
Successful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.
Severity ?
CWE
- CWE-319 - Cleartext Transmission of Sensitive Information
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Tenda | 300Mbps Wireless Router F3 and N300 Easy Setup Router |
Affected:
F3 v3.0 Firmware V12.01.01.41
Affected: F3 v3.0 Firmware V12.01.01.42 Affected: F3 v3.0 Firmware V12.01.01.48 Affected: F3 v3.0 Firmware V12.01.01.52 Affected: F3 v3.0 Firmware V12.01.01.55 Affected: F3 v4.0 Firmware V03.03.01.40 |
Credits
This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-22079",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-09T15:15:16.081528Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T15:15:27.815Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "300Mbps Wireless Router F3 and N300 Easy Setup Router",
"vendor": "Tenda",
"versions": [
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.41"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.42"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.48"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.52"
},
{
"status": "affected",
"version": "F3 v3.0 Firmware V12.01.01.55"
},
{
"status": "affected",
"version": "F3 v4.0 Firmware V03.03.01.40"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "This vulnerability is reported by Deven Lunkad, Swaroop Dora, Naziya Aslam, and S. Venkatesan from IoT Security Research Lab, Indian Institute of Information Technology, Allahabad, India."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\u003cbr\u003e\u003cbr\u003eSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device.\u003cbr\u003e"
}
],
"value": "This vulnerability exists in Tenda wireless routers (300Mbps Wireless Router F3 and N300 Easy Setup Router) due to the plaintext transmission of login credentials during the initial login or post-factory reset setup through the web-based administrative interface. An attacker on the same network could exploit this vulnerability by intercepting network traffic and capturing the credentials transmitted in plaintext.\n\nSuccessful exploitation of this vulnerability could allow the attacker to obtain sensitive information and gain unauthorized access to the targeted device."
}
],
"impacts": [
{
"capecId": "CAPEC-117",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-117 Interception"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-319",
"description": "CWE-319 Cleartext Transmission of Sensitive Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-01-09T11:25:36.253Z",
"orgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"shortName": "CERT-In"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.cert-in.org.in/s2cMainServlet?pageid=PUBVLNOTES01\u0026VLCODE=CIVN-2026-0004"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Apply appropriate updates as mentioned by the vendor:\u003cbr\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.tendacn.com/in/material/show/724624313163845\"\u003ehttps://www.tendacn.com/in/material/show/724624313163845\u003c/a\u003e\u003cbr\u003e\u003cbr\u003e"
}
],
"value": "Apply appropriate updates as mentioned by the vendor:\n https://www.tendacn.com/in/material/show/724624313163845"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Cleartext Transmission Vulnerability in Tenda Wireless Routers",
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "66834db9-ab24-42b4-be80-296b2e40335c",
"assignerShortName": "CERT-In",
"cveId": "CVE-2026-22079",
"datePublished": "2026-01-09T11:02:50.926Z",
"dateReserved": "2026-01-06T07:52:50.901Z",
"dateUpdated": "2026-01-09T15:15:27.815Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}