CWE-754
Improper Check for Unusual or Exceptional Conditions
The product does not check or incorrectly checks for unusual or exceptional conditions that are not expected to occur frequently during day to day operation of the product.
CVE-2021-1446 (GCVE-0-2021-1446)
Vulnerability from cvelistv5 – Published: 2021-03-24 20:06 – Updated: 2024-11-08 23:34
VLAI
Title
Cisco IOS XE Software DNS NAT Protocol Application Layer Gateway Denial of Service Vulnerability
Summary
A vulnerability in the DNS application layer gateway (ALG) functionality used by Network Address Translation (NAT) in Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload. The vulnerability is due to a logic error that occurs when an affected device inspects certain DNS packets. An attacker could exploit this vulnerability by sending crafted DNS packets through an affected device that is performing NAT for DNS packets. A successful exploit could allow an attacker to cause the device to reload, resulting in a denial of service (DoS) condition on an affected device. The vulnerability can be exploited only by traffic that is sent through an affected device via IPv4 packets. The vulnerability cannot be exploited via IPv6 traffic.
Severity
8.6 (High)
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco IOS XE Software |
Affected:
n/a
|
Date Public
2021-03-24 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T16:11:17.292Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20210324 Cisco IOS XE Software DNS NAT Protocol Application Layer Gateway Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-alg-dos-hbBS7SZE"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-1446",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-08T20:03:30.941464Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-08T23:34:59.559Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco IOS XE Software",
"vendor": "Cisco",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"datePublic": "2021-03-24T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the DNS application layer gateway (ALG) functionality used by Network Address Translation (NAT) in Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload. The vulnerability is due to a logic error that occurs when an affected device inspects certain DNS packets. An attacker could exploit this vulnerability by sending crafted DNS packets through an affected device that is performing NAT for DNS packets. A successful exploit could allow an attacker to cause the device to reload, resulting in a denial of service (DoS) condition on an affected device. The vulnerability can be exploited only by traffic that is sent through an affected device via IPv4 packets. The vulnerability cannot be exploited via IPv6 traffic."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-24T20:06:20.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20210324 Cisco IOS XE Software DNS NAT Protocol Application Layer Gateway Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-alg-dos-hbBS7SZE"
}
],
"source": {
"advisory": "cisco-sa-alg-dos-hbBS7SZE",
"defect": [
[
"CSCvv65113"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco IOS XE Software DNS NAT Protocol Application Layer Gateway Denial of Service Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2021-03-24T16:00:00",
"ID": "CVE-2021-1446",
"STATE": "PUBLIC",
"TITLE": "Cisco IOS XE Software DNS NAT Protocol Application Layer Gateway Denial of Service Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco IOS XE Software",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the DNS application layer gateway (ALG) functionality used by Network Address Translation (NAT) in Cisco IOS XE Software could allow an unauthenticated, remote attacker to cause an affected device to reload. The vulnerability is due to a logic error that occurs when an affected device inspects certain DNS packets. An attacker could exploit this vulnerability by sending crafted DNS packets through an affected device that is performing NAT for DNS packets. A successful exploit could allow an attacker to cause the device to reload, resulting in a denial of service (DoS) condition on an affected device. The vulnerability can be exploited only by traffic that is sent through an affected device via IPv4 packets. The vulnerability cannot be exploited via IPv6 traffic."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.6",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20210324 Cisco IOS XE Software DNS NAT Protocol Application Layer Gateway Denial of Service Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-alg-dos-hbBS7SZE"
}
]
},
"source": {
"advisory": "cisco-sa-alg-dos-hbBS7SZE",
"defect": [
[
"CSCvv65113"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2021-1446",
"datePublished": "2021-03-24T20:06:20.372Z",
"dateReserved": "2020-11-13T00:00:00.000Z",
"dateUpdated": "2024-11-08T23:34:59.559Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21439 (GCVE-0-2021-21439)
Vulnerability from cvelistv5 – Published: 2021-06-14 07:55 – Updated: 2024-09-16 19:52
VLAI
Title
Possible DoS attack using a special crafted URL in email body
Summary
DoS attack can be performed when an email contains specially designed URL in the body. It can lead to the high CPU usage and cause low quality of service, or in extreme case bring the system to a halt. This issue affects: OTRS AG ((OTRS)) Community Edition 6.0.x version 6.0.1 and later versions. OTRS AG OTRS 7.0.x version 7.0.26 and prior versions; 8.0.x version 8.0.13 and prior versions.
Severity
6.5 (Medium)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
2 references
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| OTRS AG | ((OTRS)) Community Edition |
Affected:
6.0.1 , < 6.0.x*
(custom)
|
|
| OTRS AG | OTRS |
Affected:
7.0.x , ≤ 7.0.26
(custom)
Affected: 8.0.x , ≤ 8.0.13 (custom) |
Date Public
2021-06-14 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:22.212Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://otrs.com/release-notes/otrs-security-advisory-2021-09/"
},
{
"name": "[debian-lts-announce] 20230831 [SECURITY] [DLA 3551-1] otrs2 security update",
"tags": [
"mailing-list",
"x_transferred"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/08/msg00040.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "((OTRS)) Community Edition",
"vendor": "OTRS AG",
"versions": [
{
"lessThan": "6.0.x*",
"status": "affected",
"version": "6.0.1",
"versionType": "custom"
}
]
},
{
"product": "OTRS",
"vendor": "OTRS AG",
"versions": [
{
"lessThanOrEqual": "7.0.26",
"status": "affected",
"version": "7.0.x",
"versionType": "custom"
},
{
"lessThanOrEqual": "8.0.13",
"status": "affected",
"version": "8.0.x",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-06-14T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "DoS attack can be performed when an email contains specially designed URL in the body. It can lead to the high CPU usage and cause low quality of service, or in extreme case bring the system to a halt. This issue affects: OTRS AG ((OTRS)) Community Edition 6.0.x version 6.0.1 and later versions. OTRS AG OTRS 7.0.x version 7.0.26 and prior versions; 8.0.x version 8.0.13 and prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-08-31T02:06:20.978Z",
"orgId": "2e1bf29f-dc29-4ed8-830c-7b9348b6f0e8",
"shortName": "OTRS"
},
"references": [
{
"url": "https://otrs.com/release-notes/otrs-security-advisory-2021-09/"
},
{
"name": "[debian-lts-announce] 20230831 [SECURITY] [DLA 3551-1] otrs2 security update",
"tags": [
"mailing-list"
],
"url": "https://lists.debian.org/debian-lts-announce/2023/08/msg00040.html"
}
],
"solutions": [
{
"lang": "en",
"value": "Update to OTRS 8.0.14 or OTRS 7.0.27."
}
],
"source": {
"advisory": "OSA-2021-09",
"defect": [
"2021031142000285"
],
"discovery": "USER"
},
"title": "Possible DoS attack using a special crafted URL in email body",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "2e1bf29f-dc29-4ed8-830c-7b9348b6f0e8",
"assignerShortName": "OTRS",
"cveId": "CVE-2021-21439",
"datePublished": "2021-06-14T07:55:10.080Z",
"dateReserved": "2020-12-29T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:52:22.948Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21563 (GCVE-0-2021-21563)
Vulnerability from cvelistv5 – Published: 2021-08-02 23:45 – Updated: 2024-09-16 18:07
VLAI
Summary
Dell EMC PowerScale OneFS versions 8.1.2-9.1.0.x contain an Improper Check for Unusual or Exceptional Conditions in its auditing component.This can lead to an authenticated user with low-privileges to trigger a denial of service event.
Severity
6.5 (Medium)
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/000188148 | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | PowerScale OneFS |
Affected:
8.1.2-9.1.0.x
|
Date Public
2021-06-09 00:00
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:16:23.384Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.dell.com/support/kbdoc/000188148"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PowerScale OneFS",
"vendor": "Dell",
"versions": [
{
"status": "affected",
"version": "8.1.2-9.1.0.x"
}
]
}
],
"datePublic": "2021-06-09T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Dell EMC PowerScale OneFS versions 8.1.2-9.1.0.x contain an Improper Check for Unusual or Exceptional Conditions in its auditing component.This can lead to an authenticated user with low-privileges to trigger a denial of service event."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-02T23:45:17.000Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.dell.com/support/kbdoc/000188148"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "secure@dell.com",
"DATE_PUBLIC": "2021-06-09",
"ID": "CVE-2021-21563",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PowerScale OneFS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "8.1.2-9.1.0.x"
}
]
}
}
]
},
"vendor_name": "Dell"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Dell EMC PowerScale OneFS versions 8.1.2-9.1.0.x contain an Improper Check for Unusual or Exceptional Conditions in its auditing component.This can lead to an authenticated user with low-privileges to trigger a denial of service event."
}
]
},
"impact": {
"cvss": {
"baseScore": 6.5,
"baseSeverity": "Medium",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.dell.com/support/kbdoc/000188148",
"refsource": "MISC",
"url": "https://www.dell.com/support/kbdoc/000188148"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2021-21563",
"datePublished": "2021-08-02T23:45:17.853Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-09-16T18:07:53.791Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22285 (GCVE-0-2021-22285)
Vulnerability from cvelistv5 – Published: 2022-02-04 22:29 – Updated: 2024-09-16 23:50
VLAI
Title
SECURITY – Denial of Service Vulnerabilities in SPIET800 INFI-Net to Ethernet Transfer module and PNI800 S+ Ethernet communication interface module
Summary
Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive.
Severity
7.5 (High)
CWE
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://search.abb.com/library/Download.aspx?Docu… | x_refsource_MISC |
Impacted products
Date Public
2022-02-02 00:00
Credits
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:37:18.454Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SPIET800",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "A_B",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "PNI800",
"vendor": "ABB",
"versions": [
{
"lessThanOrEqual": "A_B",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "ABB thanks Lance Lamont from Verve Industrial Protection and Ron Brash from Verve Industrial Protection/aDolus Technology Inc. helping to identify the vulnerabilities and protecting our customers."
}
],
"datePublic": "2022-02-02T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-755",
"description": "CWE-755 Improper Handling of Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754 Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-04T22:29:19.000Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"value": "ABB advises all customers to review their installations to determine if they are using an impacted product as listed above.\n\u2013 SPIET800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version A_C or later.\n\u2013 PNI800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version B_0 or later."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "SECURITY \u2013 Denial of Service Vulnerabilities in SPIET800 INFI-Net to Ethernet Transfer module and PNI800 S+ Ethernet communication interface module",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@ch.abb.com",
"DATE_PUBLIC": "2022-02-02T13:47:00.000Z",
"ID": "CVE-2021-22285",
"STATE": "PUBLIC",
"TITLE": "SECURITY \u2013 Denial of Service Vulnerabilities in SPIET800 INFI-Net to Ethernet Transfer module and PNI800 S+ Ethernet communication interface module"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SPIET800",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "A_B"
}
]
}
},
{
"product_name": "PNI800",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "A_B"
}
]
}
}
]
},
"vendor_name": "ABB"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "ABB thanks Lance Lamont from Verve Industrial Protection and Ron Brash from Verve Industrial Protection/aDolus Technology Inc. helping to identify the vulnerabilities and protecting our customers."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Handling of Exceptional Conditions, Improper Check for Unusual or Exceptional Conditions vulnerability in the ABB SPIET800 and PNI800 module that allows an attacker to cause the denial of service or make the module unresponsive."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-755 Improper Handling of Exceptional Conditions"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-754 Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "MISC",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=7PAA001353\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
]
},
"solution": [
{
"lang": "en",
"value": "ABB advises all customers to review their installations to determine if they are using an impacted product as listed above.\n\u2013 SPIET800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version A_C or later.\n\u2013 PNI800 devices with firmware version A_B or earlier are affected. All the vulnerabilities will be corrected in version B_0 or later."
}
],
"source": {
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2021-22285",
"datePublished": "2022-02-04T22:29:19.694Z",
"dateReserved": "2021-01-05T00:00:00.000Z",
"dateUpdated": "2024-09-16T23:50:37.709Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22742 (GCVE-0-2021-22742)
Vulnerability from cvelistv5 – Published: 2021-05-26 19:20 – Updated: 2024-08-03 18:51
VLAI
Summary
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.
Severity
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Triconex Model 3009 MP installed on Tricon V11.3.x systems |
Affected:
Triconex Model 3009 MP installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:06.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:18.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22742",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"version": {
"version_data": [
{
"version_value": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22742",
"datePublished": "2021-05-26T19:20:18.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:06.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22743 (GCVE-0-2021-22743)
Vulnerability from cvelistv5 – Published: 2021-05-26 19:20 – Updated: 2024-08-03 18:51
VLAI
Summary
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position.
Severity
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Triconex TCM 4351B installed on Tricon V11.3.x systems. |
Affected:
Triconex TCM 4351B installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.409Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex TCM 4351B\u00a0installed on Tricon V11.3.x systems.",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex TCM 4351B\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:22.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22743",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex TCM 4351B\u00a0installed on Tricon V11.3.x systems.",
"version": {
"version_data": [
{
"version_value": "Triconex TCM 4351B\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex TCM 4351B installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22743",
"datePublished": "2021-05-26T19:20:22.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.409Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22744 (GCVE-0-2021-22744)
Vulnerability from cvelistv5 – Published: 2021-05-26 19:20 – Updated: 2024-08-03 18:51
VLAI
Summary
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22745, CVE-2021-22746, and CVE-2021-22747.
Severity
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Triconex Model 3009 MP installed on Tricon V11.3.x systems |
Affected:
Triconex Model 3009 MP installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.457Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22745, CVE-2021-22746, and CVE-2021-22747."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:28.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22744",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"version": {
"version_data": [
{
"version_value": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22745, CVE-2021-22746, and CVE-2021-22747."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22744",
"datePublished": "2021-05-26T19:20:28.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.457Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22745 (GCVE-0-2021-22745)
Vulnerability from cvelistv5 – Published: 2021-05-26 19:20 – Updated: 2024-08-03 18:51
VLAI
Summary
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22746, and CVE-2021-22747.
Severity
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Triconex Model 3009 MP installed on Tricon V11.3.x systems |
Affected:
Triconex Model 3009 MP installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.418Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22746, and CVE-2021-22747."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:33.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22745",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"version": {
"version_data": [
{
"version_value": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22746, and CVE-2021-22747."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22745",
"datePublished": "2021-05-26T19:20:33.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.418Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22746 (GCVE-0-2021-22746)
Vulnerability from cvelistv5 – Published: 2021-05-26 19:20 – Updated: 2024-08-03 18:51
VLAI
Summary
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747.
Severity
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Triconex Model 3009 MP installed on Tricon V11.3.x systems |
Affected:
Triconex Model 3009 MP installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.103Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:38.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22746",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"version": {
"version_data": [
{
"version_value": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22747."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22746",
"datePublished": "2021-05-26T19:20:38.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.103Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22747 (GCVE-0-2021-22747)
Vulnerability from cvelistv5 – Published: 2021-05-26 19:20 – Updated: 2024-08-03 18:51
VLAI
Summary
Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746.
Severity
No CVSS data available.
CWE
- CWE-754 - Improper Check for Unusual or Exceptional Conditions
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Triconex Model 3009 MP installed on Tricon V11.3.x systems |
Affected:
Triconex Model 3009 MP installed on Tricon V11.3.x systems
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.339Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-754",
"description": "CWE-754: Improper Check for Unusual or Exceptional Conditions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-26T19:20:42.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22747",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems",
"version": {
"version_data": [
{
"version_value": "Triconex Model 3009 MP\u00a0installed on Tricon V11.3.x systems"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Check for Unusual or Exceptional Conditions vulnerability exists in Triconex Model 3009 MP installed on Tricon V11.3.x systems that could cause module reset when TCM receives malformed TriStation packets while the write-protect keyswitch is in the program position. This CVE ID is unique from CVE-2021-22742, CVE-2021-22744, CVE-2021-22745, and CVE-2021-22746."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-754: Improper Check for Unusual or Exceptional Conditions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-130-03"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22747",
"datePublished": "2021-05-26T19:20:42.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.339Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-3
Phase: Requirements
Strategy: Language Selection
Description:
- Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
- Choose languages with features such as exception handling that force the programmer to anticipate unusual conditions that may generate exceptions. Custom exceptions may need to be developed to handle unusual business-logic conditions. Be careful not to pass sensitive exceptions back to the user (CWE-209, CWE-248).
Mitigation
Phase: Implementation
Description:
- Check the results of all functions that return a value and verify that the value is expected.
Mitigation
Phase: Implementation
Description:
- If using exception handling, catch and throw specific exceptions instead of overly-general exceptions (CWE-396, CWE-397). Catch and handle exceptions as locally as possible so that exceptions do not propagate too far up the call stack (CWE-705). Avoid unchecked or uncaught exceptions where feasible (CWE-248).
Mitigation ID: MIT-39
Phase: Implementation
Description:
- Ensure that error messages only contain minimal details that are useful to the intended audience and no one else. The messages need to strike the balance between being too cryptic (which can confuse users) or being too detailed (which may reveal more than intended). The messages should not reveal the methods that were used to determine the error. Attackers can use detailed information to refine or optimize their original attack, thereby increasing their chances of success.
- If errors must be captured in some detail, record them in log messages, but consider what could occur if the log messages can be viewed by attackers. Highly sensitive information such as passwords should never be saved to log files.
- Avoid inconsistent messaging that might accidentally tip off an attacker about internal state, such as whether a user account exists or not.
- Exposing additional information to a potential attacker in the context of an exceptional condition can help the attacker determine what attack vectors are most likely to succeed beyond DoS.
Mitigation ID: MIT-5
Phase: Implementation
Strategy: Input Validation
Description:
- Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
- When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
- Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
Mitigation ID: MIT-38
Phases: Architecture and Design, Implementation
Description:
- If the program must fail, ensure that it fails gracefully (fails closed). There may be a temptation to simply let the program fail poorly in cases such as low memory conditions, but an attacker may be able to assert control before the software has fully exited. Alternately, an uncontrolled failure could cause cascading problems with other downstream components; for example, the program could send a signal to a downstream process so the process immediately knows that a problem has occurred and has a better chance of recovery.
Mitigation
Phase: Architecture and Design
Description:
- Use system limits, which should help to prevent resource exhaustion. However, the product should still handle low resource conditions since they may still occur.
No CAPEC attack patterns related to this CWE.