CWE-639
Authorization Bypass Through User-Controlled Key
The system's authorization functionality does not prevent one user from gaining access to another user's data or record by modifying the key value identifying the data.
CVE-2025-39537 (GCVE-0-2025-39537)
Vulnerability from cvelistv5 – Published: 2025-05-16 15:45 – Updated: 2026-04-28 16:12
VLAI
Title
WordPress Better Customer List for WooCommerce Plugin <= 1.2.3 - Reflected Cross Site Scripting (XSS) vulnerability
Summary
Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting') vulnerability in Blaze Concepts Better Customer List for WooCommerce woo-better-customer-list allows Reflected XSS.This issue affects Better Customer List for WooCommerce: from n/a through <= 1.2.3.
Severity
7.1 (High)
CWE
- CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://patchstack.com/database/Wordpress/Plugin/… | vdb-entry |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Blaze Concepts | Better Customer List for WooCommerce |
Affected:
0 , ≤ 1.2.3
(custom)
|
Date Public
2026-04-01 16:39
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-39537",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-16T16:37:17.719330Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-16T16:49:18.252Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://wordpress.org/plugins",
"defaultStatus": "unaffected",
"packageName": "woo-better-customer-list",
"product": "Better Customer List for WooCommerce",
"vendor": "Blaze Concepts",
"versions": [
{
"lessThanOrEqual": "1.2.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Jo\u00e3o Pedro S Alc\u00e2ntara (Kinorth) | Patchstack Bug Bounty Program"
}
],
"datePublic": "2026-04-01T16:39:30.093Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Blaze Concepts Better Customer List for WooCommerce woo-better-customer-list allows Reflected XSS.\u003cp\u003eThis issue affects Better Customer List for WooCommerce: from n/a through \u003c= 1.2.3.\u003c/p\u003e"
}
],
"value": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027) vulnerability in Blaze Concepts Better Customer List for WooCommerce woo-better-customer-list allows Reflected XSS.This issue affects Better Customer List for WooCommerce: from n/a through \u003c= 1.2.3."
}
],
"impacts": [
{
"capecId": "CAPEC-591",
"descriptions": [
{
"lang": "en",
"value": "Reflected XSS"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-04-28T16:12:34.329Z",
"orgId": "21595511-bba5-4825-b968-b78d1f9984a3",
"shortName": "Patchstack"
},
"references": [
{
"tags": [
"vdb-entry"
],
"url": "https://patchstack.com/database/Wordpress/Plugin/woo-better-customer-list/vulnerability/wordpress-better-customer-list-for-woocommerce-plugin-1-2-2-reflected-cross-site-scripting-xss-vulnerability?_s_id=cve"
}
],
"title": "WordPress Better Customer List for WooCommerce Plugin \u003c= 1.2.3 - Reflected Cross Site Scripting (XSS) vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "21595511-bba5-4825-b968-b78d1f9984a3",
"assignerShortName": "Patchstack",
"cveId": "CVE-2025-39537",
"datePublished": "2025-05-16T15:45:22.765Z",
"dateReserved": "2025-04-16T06:24:40.074Z",
"dateUpdated": "2026-04-28T16:12:34.329Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2025-4040 (GCVE-0-2025-4040)
Vulnerability from cvelistv5 – Published: 2025-07-21 12:19 – Updated: 2025-07-21 15:17
VLAI
Title
IDOR in Turpak's Automatic Station Monitoring System
Summary
Authorization Bypass Through User-Controlled Key vulnerability in Turpak Automatic Station Monitoring System allows Privilege Escalation.This issue affects Automatic Station Monitoring System: before 5.0.6.51.
Severity
7.1 (High)
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.usom.gov.tr/bildirim/tr-25-0165 | third-party-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Turpak | Automatic Station Monitoring System |
Affected:
0 , < 5.0.6.51
(custom)
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-4040",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-21T15:16:56.722923Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T15:17:05.417Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Automatic Station Monitoring System",
"vendor": "Turpak",
"versions": [
{
"lessThan": "5.0.6.51",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Burak AKSU"
},
{
"lang": "en",
"type": "sponsor",
"value": "Secure Future Inc."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Authorization Bypass Through User-Controlled Key vulnerability in Turpak Automatic Station Monitoring System allows Privilege Escalation.\u003cp\u003eThis issue affects Automatic Station Monitoring System: before 5.0.6.51.\u003c/p\u003e"
}
],
"value": "Authorization Bypass Through User-Controlled Key vulnerability in Turpak Automatic Station Monitoring System allows Privilege Escalation.This issue affects Automatic Station Monitoring System: before 5.0.6.51."
}
],
"impacts": [
{
"capecId": "CAPEC-233",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-233 Privilege Escalation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-21T12:19:28.656Z",
"orgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"shortName": "TR-CERT"
},
"references": [
{
"tags": [
"third-party-advisory"
],
"url": "https://www.usom.gov.tr/bildirim/tr-25-0165"
}
],
"source": {
"advisory": "TR-25-0165",
"defect": [
"TR-25-0165"
],
"discovery": "UNKNOWN"
},
"title": "IDOR in Turpak\u0027s Automatic Station Monitoring System",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "ca940d4e-fea4-4aa2-9a58-591a58b1ce21",
"assignerShortName": "TR-CERT",
"cveId": "CVE-2025-4040",
"datePublished": "2025-07-21T12:19:28.656Z",
"dateReserved": "2025-04-28T13:06:23.188Z",
"dateUpdated": "2025-07-21T15:17:05.417Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40650 (GCVE-0-2025-40650)
Vulnerability from cvelistv5 – Published: 2025-05-26 12:51 – Updated: 2025-05-27 14:08
VLAI
Title
Insecure Direct Object Reference (IDOR) in Clickedu
Summary
Insecure Direct Object Reference (IDOR) vulnerability in Clickedu. This vulnerability could allow an attacker to retrieve information about student report cards.
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Date Public
2025-05-26 10:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40650",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-05-27T14:08:08.837472Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-05-27T14:08:43.120Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Clickedu",
"vendor": "Clickedu",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Kevin Gonzalvo Vicente"
}
],
"datePublic": "2025-05-26T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insecure Direct Object Reference (IDOR) vulnerability in Clickedu. This vulnerability could allow an attacker to retrieve information about student report cards."
}
],
"value": "Insecure Direct Object Reference (IDOR) vulnerability in Clickedu. This vulnerability could allow an attacker to retrieve information about student report cards."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-26T12:51:32.391Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/insecure-direct-object-reference-idor-clickedu"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the Sanoma team in April 2025."
}
],
"value": "The vulnerability has been fixed by the Sanoma team in April 2025."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference (IDOR) in Clickedu",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-40650",
"datePublished": "2025-05-26T12:51:32.391Z",
"dateReserved": "2025-04-16T08:38:12.621Z",
"dateUpdated": "2025-05-27T14:08:43.120Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40658 (GCVE-0-2025-40658)
Vulnerability from cvelistv5 – Published: 2025-06-10 10:05 – Updated: 2025-06-10 13:04
VLAI
Title
Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS
Summary
An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the option parameter equal to 0, 1 or 2 in /administer/selectionnode/framesSelection.asp.
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dmacroweb | DM Corporative CMS |
Affected:
0 , < 2025.01
(custom)
|
Date Public
2025-06-10 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40658",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T13:04:40.525177Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T13:04:47.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DM Corporative CMS",
"vendor": "Dmacroweb",
"versions": [
{
"lessThan": "2025.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Oscar Atienza"
}
],
"datePublic": "2025-06-10T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u0026nbsp;option parameter equal to 0, 1 or 2 in /administer/selectionnode/framesSelection.asp."
}
],
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u00a0option parameter equal to 0, 1 or 2 in /administer/selectionnode/framesSelection.asp."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T10:05:46.265Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-dm-corporative-cms-dmacroweb"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01.\u003cbr\u003e"
}
],
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-40658",
"datePublished": "2025-06-10T10:05:46.265Z",
"dateReserved": "2025-04-16T08:38:13.918Z",
"dateUpdated": "2025-06-10T13:04:47.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40659 (GCVE-0-2025-40659)
Vulnerability from cvelistv5 – Published: 2025-06-10 10:06 – Updated: 2025-06-10 14:05
VLAI
Title
Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS
Summary
An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the option parameter equal to 0, 1 or 2 in /administer/selectionnode/framesSelectionNetworks.asp.
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dmacroweb | DM Corporative CMS |
Affected:
0 , < 2025.01
(custom)
|
Date Public
2025-06-10 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40659",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:04:54.213588Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:05:38.619Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DM Corporative CMS",
"vendor": "Dmacroweb",
"versions": [
{
"lessThan": "2025.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Oscar Atienza"
}
],
"datePublic": "2025-06-10T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u0026nbsp;option parameter equal to 0, 1 or 2 in /administer/selectionnode/framesSelectionNetworks.asp."
}
],
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u00a0option parameter equal to 0, 1 or 2 in /administer/selectionnode/framesSelectionNetworks.asp."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T10:06:09.181Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-dm-corporative-cms-dmacroweb"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01.\u003cbr\u003e"
}
],
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-40659",
"datePublished": "2025-06-10T10:06:09.181Z",
"dateReserved": "2025-04-16T08:38:13.919Z",
"dateUpdated": "2025-06-10T14:05:38.619Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40660 (GCVE-0-2025-40660)
Vulnerability from cvelistv5 – Published: 2025-06-10 10:06 – Updated: 2025-06-10 14:04
VLAI
Title
Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS
Summary
An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the option parameter equal to 0, 1 or 2 in /administer/select node/data.asp?mode=catalogue&id1=1&id2=1session=&cod=1&networks=0.
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dmacroweb | DM Corporative CMS |
Affected:
0 , < 2025.01
(custom)
|
Date Public
2025-06-10 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40660",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:03:52.769946Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:04:26.591Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DM Corporative CMS",
"vendor": "Dmacroweb",
"versions": [
{
"lessThan": "2025.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Oscar Atienza"
}
],
"datePublic": "2025-06-10T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u0026nbsp;option parameter equal to 0, 1 or 2 in /administer/select node/data.asp?mode=catalogue\u0026amp;id1=1\u0026amp;id2=1session=\u0026amp;cod=1\u0026amp;networks=0."
}
],
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u00a0option parameter equal to 0, 1 or 2 in /administer/select node/data.asp?mode=catalogue\u0026id1=1\u0026id2=1session=\u0026cod=1\u0026networks=0."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T10:06:27.167Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-dm-corporative-cms-dmacroweb"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01.\u003cbr\u003e"
}
],
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-40660",
"datePublished": "2025-06-10T10:06:27.167Z",
"dateReserved": "2025-04-16T08:38:13.919Z",
"dateUpdated": "2025-06-10T14:04:26.591Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40661 (GCVE-0-2025-40661)
Vulnerability from cvelistv5 – Published: 2025-06-10 10:06 – Updated: 2025-06-10 14:33
VLAI
Title
Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS
Summary
An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the option parameter equal to 0, 1 or 2 in /administer/selectionnode/selection.asp.
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dmacroweb | DM Corporative CMS |
Affected:
0 , < 2025.01
(custom)
|
Date Public
2025-06-10 09:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40661",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-10T14:31:40.432145Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T14:33:03.683Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "DM Corporative CMS",
"vendor": "Dmacroweb",
"versions": [
{
"lessThan": "2025.01",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Oscar Atienza"
}
],
"datePublic": "2025-06-10T09:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u0026nbsp;option parameter equal to 0, 1 or 2 in /administer/selectionnode/selection.asp."
}
],
"value": "An Insecure Direct Object Reference (IDOR) vulnerability has been found in DM Corporative CMS. This vulnerability allows an attacker to access the private area setting the\u00a0option parameter equal to 0, 1 or 2 in /administer/selectionnode/selection.asp."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 6.9,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-10T10:06:40.672Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-dm-corporative-cms-dmacroweb"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01.\u003cbr\u003e"
}
],
"value": "The vulnerability has been fixed by the Dmacroweb team in version 2025.01."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference (IDOR) vulnerability in DM Corporative CMS",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-40661",
"datePublished": "2025-06-10T10:06:40.672Z",
"dateReserved": "2025-04-16T08:38:13.919Z",
"dateUpdated": "2025-06-10T14:33:03.683Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40676 (GCVE-0-2025-40676)
Vulnerability from cvelistv5 – Published: 2025-10-07 12:21 – Updated: 2025-10-07 13:39
VLAI
Title
Múltiples vulnerabilidades en Negotiator de BBMRI-ERIC
Summary
Insecure Direct Object Reference (IDOR) in Negotiator v3.15.2 from Biobanking and Biomolecular Resources - European Research Infrastructure (BBMRI-ERIC). This vulnerability allows an attacker to access or modify unauthorised resources by manipulating requests that use the 'userID' parameter in '/api/v3/users/<userID>', which may result in the exposure or alteration of sensitive data
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| BBMRI-ERIC | Negotiator |
Affected:
0 , < 3.15.5
(custom)
|
Date Public
2025-10-07 10:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40676",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-07T13:39:34.158905Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T13:39:45.537Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Negotiator",
"vendor": "BBMRI-ERIC",
"versions": [
{
"lessThan": "3.15.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Erlaitz Parre\u00f1o Mu\u00f1oz"
}
],
"datePublic": "2025-10-07T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Insecure Direct Object Reference (IDOR) in Negotiator v3.15.2 from Biobanking and Biomolecular Resources - European Research Infrastructure (BBMRI-ERIC). This vulnerability allows an attacker to access or modify unauthorised resources by manipulating requests that use the \u0027userID\u0027 parameter in \u0027/api/v3/users/\u0026lt;userID\u0026gt;\u0027, which may result in the exposure or alteration of sensitive data"
}
],
"value": "Insecure Direct Object Reference (IDOR) in Negotiator v3.15.2 from Biobanking and Biomolecular Resources - European Research Infrastructure (BBMRI-ERIC). This vulnerability allows an attacker to access or modify unauthorised resources by manipulating requests that use the \u0027userID\u0027 parameter in \u0027/api/v3/users/\u003cuserID\u003e\u0027, which may result in the exposure or alteration of sensitive data"
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639 Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-07T12:21:37.629Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso/multiple-vulnerabilities-bbmri-eric-negotiator"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "The vulnerability has been fixed by the BBMRI-ERIC team in version 3.15.5."
}
],
"value": "The vulnerability has been fixed by the BBMRI-ERIC team in version 3.15.5."
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "M\u00faltiples vulnerabilidades en Negotiator de BBMRI-ERIC",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2025-40676",
"datePublished": "2025-10-07T12:21:37.629Z",
"dateReserved": "2025-04-16T08:38:16.028Z",
"dateUpdated": "2025-10-07T13:39:45.537Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40773 (GCVE-0-2025-40773)
Vulnerability from cvelistv5 – Published: 2025-10-14 09:15 – Updated: 2025-10-14 19:00
VLAI
Summary
A vulnerability has been identified in SiPass integrated (All versions < V3.0). Affected server applications contains a broken access control vulnerability. The authorization mechanism lacks sufficient server-side checks, allowing an attacker to execute a specific API request.
Successful exploitation allows an attacker to potentially manipulate data belonging to other users.
Severity
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens | SiPass integrated |
Affected:
0 , < V3.0
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40773",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-14T19:00:31.582611Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T19:00:40.677Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SiPass integrated",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SiPass integrated (All versions \u003c V3.0). Affected server applications contains a broken access control vulnerability. The authorization mechanism lacks sufficient server-side checks, allowing an attacker to execute a specific API request.\r\n\r\nSuccessful exploitation allows an attacker to potentially manipulate data belonging to other users."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 3.5,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:L/UI:N/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639: Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-14T09:15:19.971Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-599451.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40773",
"datePublished": "2025-10-14T09:15:19.971Z",
"dateReserved": "2025-04-16T08:39:30.033Z",
"dateUpdated": "2025-10-14T19:00:40.677Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2025-40805 (GCVE-0-2025-40805)
Vulnerability from cvelistv5 – Published: 2026-01-13 09:44 – Updated: 2026-05-12 08:20
VLAI
Summary
Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user.
Severity
10 (Critical)
CWE
- CWE-639 - Authorization Bypass Through User-Controlled Key
Assigner
References
Impacted products
108 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-40805",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-01-13T17:37:11.802050Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-01-13T17:37:40.414Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Industrial Edge Cloud Device (IECD)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.10",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.11",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.13",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.14",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.15",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.21",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.22",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.23",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.24",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.25",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.25.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - arm64 V1.9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.10",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.11",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.12",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.13",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.14",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.15",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.16",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.17",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.18",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.19",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.20",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.21",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.22",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.23",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.24",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.25",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.25.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.5",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.7",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Device Kit - x86-64 V1.9",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Own Device (IEOD)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Industrial Edge Virtual Device (IEVD)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.24.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE LPE9413",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SCALANCE LPE9433",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Automation Workstation 19\"",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC Automation Workstation 24\"",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.3",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1000, Unified Comfort Panel neutral",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1200 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1500 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP1900 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro for support arm (expandable, round tube) and extension unit",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro neutral design for stand (expandable, flange at the bottom)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (expandable, round tube) and extensio",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Comfort Pro neutral design for support arm (not extendable, flange on top)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Hygienic",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP2200 Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700\u00a0Unified Comfort Panel",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700 Unified Comfort Panel hygienic neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC HMI MTP700, Unified Comfort Panel neutral design",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IOT2050",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V1.25.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-39A Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC BX-59A Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC127E Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227E Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC227G Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC427E Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIMATIC IPC847E Industrial Edge Device",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HMI MTP1000 Unified Comfort",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HMI MTP1200 Unified Comfort",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPLUS HMI MTP700 Unified Comfort",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V21",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Affected devices do not properly enforce user authentication on specific API endpoints. This could facilitate an unauthenticated remote attacker to circumvent authentication and impersonate a legitimate user. Successful exploitation requires that the attacker has learned the identity of a legitimate user."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 10,
"baseSeverity": "CRITICAL",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-639",
"description": "CWE-639: Authorization Bypass Through User-Controlled Key",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-05-12T08:20:44.842Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-014678.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-001536.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2025-40805",
"datePublished": "2026-01-13T09:44:03.338Z",
"dateReserved": "2025-04-16T08:50:26.973Z",
"dateUpdated": "2026-05-12T08:20:44.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
Mitigation
Phase: Architecture and Design
Description:
- For each and every data access, ensure that the user has sufficient privilege to access the record that is being requested.
Mitigation
Phases: Architecture and Design, Implementation
Description:
- Make sure that the key that is used in the lookup of a specific user's record is not controllable externally by the user or that any tampering can be detected.
Mitigation
Phase: Architecture and Design
Description:
- Use encryption in order to make it more difficult to guess other legitimate values of the key or associate a digital signature with the key so that the server can verify that there has been no tampering.
No CAPEC attack patterns related to this CWE.