CWE-400

Uncontrolled Resource Consumption

The product does not properly control the allocation and maintenance of a limited resource.

CVE-2017-2681 (GCVE-0-2017-2681)

Vulnerability from cvelistv5 – Published: 2017-05-11 10:00 – Updated: 2024-09-10 09:33
VLAI
Summary
Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected.
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
Impacted products
Vendor Product Version
Siemens Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller Affected: All versions < V4.1.1 Patch04
Create a notification for this product.
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200 Affected: All versions < V4.2.1 Patch03
Create a notification for this product.
Siemens Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P Affected: All versions < V4.4.0 Patch01
Create a notification for this product.
Siemens IE/AS-i Link PN IO Affected: All versions
Create a notification for this product.
Siemens IE/PB-Link (incl. SIPLUS NET variants) Affected: All versions < V3.0
Create a notification for this product.
Siemens SCALANCE M-800 family (incl. S615, MUM-800 and RM1224) Affected: All versions < V4.03
Create a notification for this product.
Siemens SCALANCE W-700 IEEE 802.11n family Affected: All versions < V6.1
Create a notification for this product.
Siemens SCALANCE X-200 family (incl. SIPLUS NET variants) Affected: All versions < V5.2.2
Create a notification for this product.
Siemens SCALANCE X-200IRT family (incl. SIPLUS NET variants) Affected: All versions < V5.4.0
Create a notification for this product.
Siemens SCALANCE X-300 family (incl. X408 and SIPLUS NET variants) Affected: All versions < V4.1.0
Create a notification for this product.
Siemens SCALANCE X408 family Affected: All versions < V4.1.0
Create a notification for this product.
Siemens SCALANCE X414 Affected: All versions < V3.10.2
Create a notification for this product.
Siemens SCALANCE XM-400 family Affected: All versions < V6.1
Create a notification for this product.
Siemens SCALANCE XR-500 family Affected: All versions < V6.1
Create a notification for this product.
Siemens SIMATIC CM 1542-1 Affected: All versions < V2.0
Create a notification for this product.
Siemens SIMATIC CM 1542SP-1 Affected: All versions < V1.0.15
Create a notification for this product.
Siemens SIMATIC CP 1243-1 (incl. SIPLUS variants) Affected: All versions < V2.1.82
Create a notification for this product.
Siemens SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SIMATIC CP 1243-8 IRC Affected: All versions < V2.1.82
Create a notification for this product.
Siemens SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants) Affected: All versions < V1.0.15
Create a notification for this product.
Siemens SIMATIC CP 1543-1 (incl. SIPLUS variants) Affected: All versions < V2.1
Create a notification for this product.
Siemens SIMATIC CP 1543SP-1 (incl. SIPLUS variants) Affected: All versions < V1.0.15
Create a notification for this product.
Siemens SIMATIC CP 1604 Affected: All versions < V2.7
Create a notification for this product.
Siemens SIMATIC CP 1616 Affected: All versions < V2.7
Create a notification for this product.
Siemens SIMATIC CP 343-1 (incl. SIPLUS variants) Affected: All versions < V3.1.3
Create a notification for this product.
Siemens SIMATIC CP 343-1 Advanced (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SIMATIC CP 343-1 Lean (incl. SIPLUS variants) Affected: All versions < V3.1.3
Create a notification for this product.
Siemens SIMATIC CP 443-1 (incl. SIPLUS variants) Affected: All versions < V3.2.17
Create a notification for this product.
Siemens SIMATIC CP 443-1 Advanced (incl. SIPLUS variants) Affected: All versions < V3.2.17
Create a notification for this product.
Siemens SIMATIC CP 443-1 OPC UA Affected: All versions
Create a notification for this product.
Siemens SIMATIC DK-16xx PN IO Affected: All versions < V2.7
Create a notification for this product.
Siemens SIMATIC ET 200AL IM 157-1 PN Affected: 0 , < V1.0.2 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200M (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET 200MP IM 155-5 PN BA Affected: 0 , < V4.0.1 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200MP IM 155-5 PN HF Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200MP IM 155-5 PN ST Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200pro IM 154-3 PN HF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMATIC ET 200pro IM 154-4 PN HF Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMATIC ET 200SP IM 155-6 PN BA Affected: 0 , < * (custom)
Create a notification for this product.
Siemens SIMATIC ET 200SP IM 155-6 PN HF Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200SP IM 155-6 PN HS Affected: 0 , < V4.0.1 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200SP IM 155-6 PN ST Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIMATIC ET 200SP IM 155-6 PN ST BA Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 4AO U/I 4xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12 Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200ecoPN: IO-Link Master Affected: All versions
Create a notification for this product.
Siemens SIMATIC ET200S (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants) Affected: All versions < V15.1
Create a notification for this product.
Siemens SIMATIC MV420 SR-B Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC MV420 SR-B Body Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC MV420 SR-P Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC MV420 SR-P Body Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC MV440 HR Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC MV440 SR Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC MV440 UR Affected: 0 , < V7.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC PN/PN Coupler (incl. SIPLUS NET variants) Affected: All versions < V4.0
Create a notification for this product.
Siemens SIMATIC RF650R Affected: All versions < V3.0
Create a notification for this product.
Siemens SIMATIC RF680R Affected: All versions < V3.0
Create a notification for this product.
Siemens SIMATIC RF685R Affected: All versions < V3.0
Create a notification for this product.
Siemens SIMATIC S7-1200 CPU family (incl. SIPLUS variants) Affected: All versions < V4.2.1
Create a notification for this product.
Siemens SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: All versions < V2.1
Create a notification for this product.
Siemens SIMATIC S7-1500 Software Controller Affected: All versions < V2.1
Create a notification for this product.
Siemens SIMATIC S7-200 SMART Affected: All versions < V2.3
Create a notification for this product.
Siemens SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants) Affected: 0 , < V3.X.14 (custom)
Create a notification for this product.
Siemens SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants) Affected: 0 , < V6.0.7 (custom)
Create a notification for this product.
Siemens SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) Affected: 0 , < V6.0.6 (custom)
Create a notification for this product.
Siemens SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) Affected: 0 , < V7.0.2 (custom)
Create a notification for this product.
Siemens SIMATIC S7-410 CPU family (incl. SIPLUS variants) Affected: All versions < V8.2
Create a notification for this product.
Siemens SIMATIC TDC CP51M1 Affected: 0 , < V1.1.8 (custom)
Create a notification for this product.
Siemens SIMATIC TDC CPU555 Affected: 0 , < V1.1.1 (custom)
Create a notification for this product.
Siemens SIMATIC Teleservice Adapter IE Advanced Affected: All versions
Create a notification for this product.
Siemens SIMATIC Teleservice Adapter IE Basic Affected: All versions
Create a notification for this product.
Siemens SIMATIC Teleservice Adapter IE Standard Affected: All versions
Create a notification for this product.
Siemens SIMATIC WinAC RTX 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
Siemens SIMATIC WinAC RTX F 2010 Affected: All versions < V2010 SP3
Create a notification for this product.
Siemens SIMOCODE pro V PROFINET (incl. SIPLUS variants) Affected: All versions < V2.0.0
Create a notification for this product.
Siemens SIMOTION Affected: All versions < V4.5 HF1
Create a notification for this product.
Siemens SINAMICS DCM w. PN Affected: All versions < V1.4 SP1 HF5
Create a notification for this product.
Siemens SINAMICS DCP w. PN Affected: All versions < V1.2 HF1
Create a notification for this product.
Siemens SINAMICS G110M w. PN Affected: All versions < V4.7 SP6 HF3
Create a notification for this product.
Siemens SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants) Affected: All versions < V4.7 SP6 HF3
Create a notification for this product.
Siemens SINAMICS G130 V4.7 w. PN Affected: All versions < V4.7 HF27
Create a notification for this product.
Siemens SINAMICS G130 V4.8 w. PN Affected: All versions < V4.8 HF4
Create a notification for this product.
Siemens SINAMICS G150 V4.7 w. PN Affected: V4.7: All versions < V4.7 HF27
Create a notification for this product.
Siemens SINAMICS G150 V4.8 w. PN Affected: All versions < V4.8 HF4
Create a notification for this product.
Siemens SINAMICS S110 w. PN Affected: All versions < V4.4 SP3 HF5
Create a notification for this product.
Siemens SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants) Affected: All versions < V4.7
Create a notification for this product.
Siemens SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants) Affected: All versions
Create a notification for this product.
Siemens SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants) Affected: All versions < V4.7 HF27
Create a notification for this product.
Siemens SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants) Affected: All versions < V4.8 HF4
Create a notification for this product.
Siemens SINAMICS S150 V4.7 w. PN Affected: All versions < V4.7 HF27
Create a notification for this product.
Siemens SINAMICS S150 V4.8 w. PN Affected: All versions < V4.8 HF4
Create a notification for this product.
Siemens SINAMICS V90 w. PN Affected: All versions < V1.01
Create a notification for this product.
Siemens SINUMERIK 828D V4.5 and prior Affected: All versions < V4.5 SP6 HF2
Create a notification for this product.
Siemens SINUMERIK 828D V4.7 Affected: All versions < V4.7 SP4 HF1
Create a notification for this product.
Siemens SINUMERIK 840D sl V4.5 and prior Affected: All versions < V4.5 SP6 HF2
Create a notification for this product.
Siemens SINUMERIK 840D sl V4.7 Affected: All versions < V4.7 SP4 HF1
Create a notification for this product.
Siemens SIPLUS ET 200MP IM 155-5 PN HF Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200MP IM 155-5 PN HF Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200MP IM 155-5 PN ST Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200MP IM 155-5 PN ST TX RAIL Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN HF Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN HF Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL Affected: 0 , < V4.2.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN ST Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIPLUS ET 200SP IM 155-6 PN ST TX RAIL Affected: 0 , < V4.1.0 (custom)
Create a notification for this product.
Siemens SIRIUS ACT 3SU1 interface module PROFINET Affected: All versions < V1.1.0
Create a notification for this product.
Siemens SIRIUS Motor Starter M200D PROFINET Affected: All versions
Create a notification for this product.
Siemens SIRIUS Soft Starter 3RW44 PN Affected: All versions
Create a notification for this product.
Siemens SITOP PSU8600 PROFINET Affected: All versions < V1.2.0
Create a notification for this product.
Siemens SITOP UPS1600 PROFINET (incl. SIPLUS variants) Affected: All versions < V2.2.0
Create a notification for this product.
Siemens Softnet PROFINET IO for PC-based Windows systems Affected: All versions < V14 SP1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2017-2681",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-23T20:22:19.045364Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T20:22:26.181Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T14:02:07.386Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1038463",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038463"
          },
          {
            "name": "98369",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98369"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: DK Standard Ethernet Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.1 Patch04"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1 Patch03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Development/Evaluation Kits for PROFINET IO: EK-ERTEC 200P",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4.0 Patch01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/AS-i Link PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "IE/PB-Link (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE M-800 family (incl. S615, MUM-800 and RM1224)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.03"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE W-700 IEEE 802.11n family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200 family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-200IRT family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X-300 family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X408 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE X414",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.10.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XM-400 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SCALANCE XR-500 family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V6.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CM 1542SP-1",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-1 IEC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1243-8 IRC",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1.82"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1542SP-1 IRC (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1543SP-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.0.15"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1604",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 1616",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 343-1 Lean (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 Advanced (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.17"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC CP 443-1 OPC UA",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC DK-16xx PN IO",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200AL IM 157-1 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200M (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-3 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200pro IM 154-4 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN HS",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.0.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 16DO DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 4AO U/I 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DIO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8 DO, DC24V/2A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8AI; 4 U/I; 4 RTD/TC 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DI, DC24V, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/0,5A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 4xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN, 8DO, DC24V/1,3A, 8xM12",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200ecoPN: IO-Link Master",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC ET200S (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC HMI Comfort Panels, HMI Multi Panels, HMI Mobile Panels (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V15.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-B Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV420 SR-P Body",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 HR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 SR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC MV440 UR",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC PN/PN Coupler (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF650R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF680R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC RF685R",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-1500 Software Controller",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-200 SMART",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-300 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V3.X.14",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 H V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V6.0.6",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V7.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC S7-410 CPU family (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V8.2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CP51M1",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.8",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC TDC CPU555",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V1.1.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Advanced",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Basic",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC Teleservice Adapter IE Standard",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMATIC WinAC RTX F 2010",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2010 SP3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOCODE pro V PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.0.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIMOTION",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCM w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.4 SP1 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS DCP w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G110M w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G120(C/P/D) w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP6 HF3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G130 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "V4.7: All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS G150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S110 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.4 SP3 HF5"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 prior to V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 SP1 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.7 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S120 V4.8 w. PN (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.7 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 HF27"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS S150 V4.8 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.8 HF4"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINAMICS V90 w. PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.01"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 828D V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.5 and prior",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.5 SP6 HF2"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SINUMERIK 840D sl V4.7",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.7 SP4 HF1"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200MP IM 155-5 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN HF T1 RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST BA TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIPLUS ET 200SP IM 155-6 PN ST TX RAIL",
          "vendor": "Siemens",
          "versions": [
            {
              "lessThan": "V4.1.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS ACT 3SU1 interface module PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.1.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Motor Starter M200D PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SIRIUS Soft Starter 3RW44 PN",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP PSU8600 PROFINET",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V1.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "SITOP UPS1600 PROFINET (incl. SIPLUS variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V2.2.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Softnet PROFINET IO for PC-based Windows systems",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V14 SP1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Specially crafted PROFINET DCP packets sent on a local Ethernet segment (Layer 2) to an affected product could cause a denial of service condition of that product. Human interaction is required to recover the system. PROFIBUS interfaces are not affected."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        {
          "cvssV4_0": {
            "baseScore": 7.1,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400: Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-09-10T09:33:20.658Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "1038463",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038463"
        },
        {
          "name": "98369",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98369"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-293562.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-293562.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/html/ssa-293562.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-2681",
    "datePublished": "2017-05-11T10:00:00.000Z",
    "dateReserved": "2016-12-01T00:00:00.000Z",
    "dateUpdated": "2024-09-10T09:33:20.658Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6017 (GCVE-0-2017-6017)

Vulnerability from cvelistv5 – Published: 2017-06-30 02:35 – Updated: 2024-08-05 15:18
VLAI
Summary
A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Schneider Electric Modicon M340 PLC Affected: Schneider Electric Modicon M340 PLC
Date Public
2017-06-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.611Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"
          },
          {
            "name": "96414",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96414"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Modicon M340 PLC",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Modicon M340 PLC"
            }
          ]
        }
      ],
      "datePublic": "2017-06-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-12-24T15:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"
        },
        {
          "name": "96414",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96414"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6017",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Modicon M340 PLC",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Modicon M340 PLC"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Resource Exhaustion issue was discovered in Schneider Electric Modicon M340 PLC BMXNOC0401, BMXNOE0100, BMXNOE0110, BMXNOE0110H, BMXNOR0200H, BMXP341000, BMXP342000, BMXP3420102, BMXP3420102CL, BMXP342020, BMXP342020H, BMXP342030, BMXP3420302, BMXP3420302H, and BMXP342030H. A remote attacker could send a specially crafted set of packets to the PLC causing it to freeze, requiring the operator to physically press the reset button on the PLC in order to recover."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/",
              "refsource": "CONFIRM",
              "url": "https://www.schneider-electric.com/en/download/document/SEVD-2017-048-02/"
            },
            {
              "name": "96414",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96414"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-054-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6017",
    "datePublished": "2017-06-30T02:35:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.611Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6019 (GCVE-0-2017-6019)

Vulnerability from cvelistv5 – Published: 2017-04-07 22:00 – Updated: 2024-08-05 15:18
VLAI
Summary
An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Schneider Electric Conext ComBox Affected: Schneider Electric Conext ComBox
Date Public
2017-04-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.485Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01"
          },
          {
            "name": "96543",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/96543"
          },
          {
            "name": "41537",
            "tags": [
              "exploit",
              "x_refsource_EXPLOIT-DB",
              "x_transferred"
            ],
            "url": "https://www.exploit-db.com/exploits/41537/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Conext ComBox",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Conext ComBox"
            }
          ]
        }
      ],
      "datePublic": "2017-04-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-15T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01"
        },
        {
          "name": "96543",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/96543"
        },
        {
          "name": "41537",
          "tags": [
            "exploit",
            "x_refsource_EXPLOIT-DB"
          ],
          "url": "https://www.exploit-db.com/exploits/41537/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6019",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Conext ComBox",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Conext ComBox"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An issue was discovered in Schneider Electric Conext ComBox, model 865-1058, all firmware versions prior to V3.03 BN 830. A series of rapid requests to the device may cause it to reboot."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-061-02"
            },
            {
              "name": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01",
              "refsource": "CONFIRM",
              "url": "http://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2017-052-01"
            },
            {
              "name": "96543",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/96543"
            },
            {
              "name": "41537",
              "refsource": "EXPLOIT-DB",
              "url": "https://www.exploit-db.com/exploits/41537/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6019",
    "datePublished": "2017-04-07T22:00:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.485Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6024 (GCVE-0-2017-6024)

Vulnerability from cvelistv5 – Published: 2017-05-06 00:00 – Updated: 2024-08-05 15:18
VLAI
Summary
A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Rockwell Automation ControlLogix 5580 and CompactLogix 5380 Affected: Rockwell Automation ControlLogix 5580 and CompactLogix 5380
Date Public
2017-05-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.530Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05"
          },
          {
            "name": "98309",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98309"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380"
            }
          ]
        }
      ],
      "datePublic": "2017-05-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-08T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05"
        },
        {
          "name": "98309",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98309"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6024",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Rockwell Automation ControlLogix 5580 and CompactLogix 5380"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Resource Exhaustion issue was discovered in Rockwell Automation ControlLogix 5580 controllers V28.011, V28.012, and V28.013; ControlLogix 5580 controllers V29.011; CompactLogix 5380 controllers V28.011; and CompactLogix 5380 controllers V29.011. This vulnerability may allow an attacker to cause a denial of service condition by sending a series of specific CIP-based commands to the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-094-05"
            },
            {
              "name": "98309",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98309"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6024",
    "datePublished": "2017-05-06T00:00:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.530Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-6043 (GCVE-0-2017-6043)

Vulnerability from cvelistv5 – Published: 2017-06-21 19:00 – Updated: 2024-08-05 15:18
VLAI
Summary
A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Trihedral VTScada Affected: Trihedral VTScada
Date Public
2017-06-21 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T15:18:49.741Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01"
          },
          {
            "name": "99066",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99066"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Trihedral VTScada",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Trihedral VTScada"
            }
          ]
        }
      ],
      "datePublic": "2017-06-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-06-22T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01"
        },
        {
          "name": "99066",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99066"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-6043",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Trihedral VTScada",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Trihedral VTScada"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Resource Consumption issue was discovered in Trihedral VTScada Versions prior to 11.2.26. The client does not properly validate the input or limit the amount of resources that are utilized by an attacker, which can be used to consume more resources than are available."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-01"
            },
            {
              "name": "99066",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99066"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-6043",
    "datePublished": "2017-06-21T19:00:00.000Z",
    "dateReserved": "2017-02-16T00:00:00.000Z",
    "dateUpdated": "2024-08-05T15:18:49.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7521 (GCVE-0-2017-7521)

Vulnerability from cvelistv5 – Published: 2017-06-27 13:00 – Updated: 2024-08-05 16:04
VLAI
Summary
OpenVPN versions before 2.4.3 and before 2.3.17 are vulnerable to remote denial-of-service due to memory exhaustion caused by memory leaks and double-free issue in extract_x509_extension().
Severity
No CVSS data available.
CWE
Assigner
References
URL Tags
https://community.openvpn.net/openvpn/wiki/Vulner… x_refsource_CONFIRM
http://www.securitytracker.com/id/1038768 vdb-entryx_refsource_SECTRACK
http://www.securityfocus.com/bid/99230 vdb-entryx_refsource_BID
http://www.debian.org/security/2017/dsa-3900 vendor-advisoryx_refsource_DEBIAN
Impacted products
Vendor Product Version
OpenVPN Technologies, Inc OpenVPN Affected: before 2.4.3
Affected: before 2.3.17
Create a notification for this product.
Date Public
2017-06-21 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:04:11.856Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243"
          },
          {
            "name": "1038768",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038768"
          },
          {
            "name": "99230",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99230"
          },
          {
            "name": "DSA-3900",
            "tags": [
              "vendor-advisory",
              "x_refsource_DEBIAN",
              "x_transferred"
            ],
            "url": "http://www.debian.org/security/2017/dsa-3900"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OpenVPN",
          "vendor": "OpenVPN Technologies, Inc",
          "versions": [
            {
              "status": "affected",
              "version": "before 2.4.3"
            },
            {
              "status": "affected",
              "version": "before 2.3.17"
            }
          ]
        }
      ],
      "datePublic": "2017-06-21T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "OpenVPN versions before 2.4.3 and before 2.3.17 are vulnerable to remote denial-of-service due to memory exhaustion caused by memory leaks and double-free issue in extract_x509_extension()."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-11-03T18:57:01.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243"
        },
        {
          "name": "1038768",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038768"
        },
        {
          "name": "99230",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99230"
        },
        {
          "name": "DSA-3900",
          "tags": [
            "vendor-advisory",
            "x_refsource_DEBIAN"
          ],
          "url": "http://www.debian.org/security/2017/dsa-3900"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2017-7521",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OpenVPN",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "before 2.4.3"
                          },
                          {
                            "version_value": "before 2.3.17"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "OpenVPN Technologies, Inc"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "OpenVPN versions before 2.4.3 and before 2.3.17 are vulnerable to remote denial-of-service due to memory exhaustion caused by memory leaks and double-free issue in extract_x509_extension()."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243",
              "refsource": "CONFIRM",
              "url": "https://community.openvpn.net/openvpn/wiki/VulnerabilitiesFixedInOpenVPN243"
            },
            {
              "name": "1038768",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1038768"
            },
            {
              "name": "99230",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99230"
            },
            {
              "name": "DSA-3900",
              "refsource": "DEBIAN",
              "url": "http://www.debian.org/security/2017/dsa-3900"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2017-7521",
    "datePublished": "2017-06-27T13:00:00.000Z",
    "dateReserved": "2017-04-05T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:04:11.856Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7935 (GCVE-0-2017-7935)

Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 16:19
VLAI
Summary
A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device's availability by performing multiple initial VPN requests.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Phoenix Contact GmbH mGuard Affected: Phoenix Contact GmbH mGuard
Date Public
2017-05-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Phoenix Contact GmbH mGuard",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Phoenix Contact GmbH mGuard"
            }
          ]
        }
      ],
      "datePublic": "2017-05-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device\u0027s availability by performing multiple initial VPN requests."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-19T02:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7935",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Phoenix Contact GmbH mGuard",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Phoenix Contact GmbH mGuard"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A Resource Exhaustion issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may compromise the device\u0027s availability by performing multiple initial VPN requests."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7935",
    "datePublished": "2017-05-19T02:43:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9627 (GCVE-0-2017-9627)

Vulnerability from cvelistv5 – Published: 2017-07-07 17:00 – Updated: 2024-08-05 17:11
VLAI
Summary
An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Schneider Electric Wonderware ArchestrA Logger Affected: Schneider Electric Wonderware ArchestrA Logger
Date Public
2017-07-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:11:02.370Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99488",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99488"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"
          },
          {
            "name": "1038836",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1038836"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Schneider Electric Wonderware ArchestrA Logger",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Schneider Electric Wonderware ArchestrA Logger"
            }
          ]
        }
      ],
      "datePublic": "2017-07-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-07-11T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "99488",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99488"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"
        },
        {
          "name": "1038836",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1038836"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9627",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Schneider Electric Wonderware ArchestrA Logger",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Schneider Electric Wonderware ArchestrA Logger"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Uncontrolled Resource Consumption issue was discovered in Schneider Electric Wonderware ArchestrA Logger, versions 2017.426.2307.1 and prior. The uncontrolled resource consumption vulnerability could allow an attacker to exhaust the memory resources of the machine, causing a denial of service."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99488",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99488"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-187-04"
            },
            {
              "name": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/",
              "refsource": "MISC",
              "url": "http://software.schneider-electric.com/pdf/security-bulletin/lfsec00000116/"
            },
            {
              "name": "1038836",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1038836"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9627",
    "datePublished": "2017-07-07T17:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:11:02.370Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-0048 (GCVE-0-2018-0048)

Vulnerability from cvelistv5 – Published: 2018-10-10 18:00 – Updated: 2024-09-16 20:03
VLAI
Title
Junos OS: Memory exhaustion denial of service vulnerability in Routing Protocols Daemon (RPD) with Juniper Extension Toolkit (JET) support.
Summary
A vulnerability in the Routing Protocols Daemon (RPD) with Juniper Extension Toolkit (JET) support can allow a network based unauthenticated attacker to cause a severe memory exhaustion condition on the device. This can have an adverse impact on the system performance and availability. This issue only affects devices with JET support running Junos OS 17.2R1 and subsequent releases. Other versions of Junos OS are unaffected by this vulnerability. Affected releases are Juniper Networks Junos OS: 17.2 versions prior to 17.2R1-S7, 17.2R2-S6, 17.2R3; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R2-S4, 17.3R3; 17.4 versions prior to 17.4R1-S5, 17.4R2; 18.1 versions prior to 18.1R2-S3, 18.1R3;
CWE
  • CWE-400 - Uncontrolled Resource Consumption
Assigner
References
URL Tags
http://www.securityfocus.com/bid/105564 vdb-entryx_refsource_BID
http://www.securitytracker.com/id/1041849 vdb-entryx_refsource_SECTRACK
https://kb.juniper.net/JSA10882 x_refsource_CONFIRM
Impacted products
Vendor Product Version
Juniper Networks Junos OS Affected: 17.2 , < 17.2R1-S7, 17.2R2-S6, 17.2R3 (custom)
Affected: 17.2X75 , < 17.2X75-D102, 17.2X75-D110 (custom)
Affected: 17.3 , < 17.3R2-S4, 17.3R3 (custom)
Affected: 17.4 , < 17.4R1-S5, 17.4R2 (custom)
Affected: 18.1 , < 18.1R2-S3, 18.1R3 (custom)
Create a notification for this product.
Date Public
2018-10-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T03:14:16.663Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105564",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105564"
          },
          {
            "name": "1041849",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1041849"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://kb.juniper.net/JSA10882"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "17.2R1-S7, 17.2R2-S6, 17.2R3",
              "status": "affected",
              "version": "17.2",
              "versionType": "custom"
            },
            {
              "lessThan": "17.2X75-D102, 17.2X75-D110",
              "status": "affected",
              "version": "17.2X75",
              "versionType": "custom"
            },
            {
              "lessThan": "17.3R2-S4, 17.3R3",
              "status": "affected",
              "version": "17.3",
              "versionType": "custom"
            },
            {
              "lessThan": "17.4R1-S5, 17.4R2",
              "status": "affected",
              "version": "17.4",
              "versionType": "custom"
            },
            {
              "lessThan": "18.1R2-S3, 18.1R3",
              "status": "affected",
              "version": "18.1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2018-10-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the Routing Protocols Daemon (RPD) with Juniper Extension Toolkit (JET) support can allow a network based unauthenticated attacker to cause a severe memory exhaustion condition on the device. This can have an adverse impact on the system performance and availability. This issue only affects devices with JET support running Junos OS 17.2R1 and subsequent releases. Other versions of Junos OS are unaffected by this vulnerability. Affected releases are Juniper Networks Junos OS: 17.2 versions prior to 17.2R1-S7, 17.2R2-S6, 17.2R3; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R2-S4, 17.3R3; 17.4 versions prior to 17.4R1-S5, 17.4R2; 18.1 versions prior to 18.1R2-S3, 18.1R3;"
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400 Uncontrolled Resource Consumption",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-16T09:57:01.000Z",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "name": "105564",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105564"
        },
        {
          "name": "1041849",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1041849"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://kb.juniper.net/JSA10882"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "The following software releases have been updated to resolve this specific issue: 17.2R1-S7, 17.2R2-S6, 17.2R3, 17.2X75-D102, 17.2X75-D110, 17.3R2-S4, 17.3R3, 17.4R1-S5, 17.4R2, 18.1R2-S3, 18.1R3, 18.2R1, 18.2X75-D10, 18.3R1, and all subsequent releases."
        }
      ],
      "source": {
        "advisory": "JSA10882",
        "defect": [
          "1344177"
        ],
        "discovery": "INTERNAL"
      },
      "title": "Junos OS: Memory exhaustion denial of service vulnerability in Routing Protocols Daemon (RPD) with Juniper Extension Toolkit (JET) support.",
      "workarounds": [
        {
          "lang": "en",
          "value": "There are no viable workarounds for this issue."
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@juniper.net",
          "DATE_PUBLIC": "2018-10-10T16:00:00.000Z",
          "ID": "CVE-2018-0048",
          "STATE": "PUBLIC",
          "TITLE": "Junos OS: Memory exhaustion denial of service vulnerability in Routing Protocols Daemon (RPD) with Juniper Extension Toolkit (JET) support."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Junos OS",
                      "version": {
                        "version_data": [
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "17.2",
                            "version_value": "17.2R1-S7, 17.2R2-S6, 17.2R3"
                          },
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "17.2X75",
                            "version_value": "17.2X75-D102, 17.2X75-D110"
                          },
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "17.3",
                            "version_value": "17.3R2-S4, 17.3R3"
                          },
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "17.4",
                            "version_value": "17.4R1-S5, 17.4R2"
                          },
                          {
                            "affected": "\u003c",
                            "version_affected": "\u003c",
                            "version_name": "18.1",
                            "version_value": "18.1R2-S3, 18.1R3"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Juniper Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the Routing Protocols Daemon (RPD) with Juniper Extension Toolkit (JET) support can allow a network based unauthenticated attacker to cause a severe memory exhaustion condition on the device. This can have an adverse impact on the system performance and availability. This issue only affects devices with JET support running Junos OS 17.2R1 and subsequent releases. Other versions of Junos OS are unaffected by this vulnerability. Affected releases are Juniper Networks Junos OS: 17.2 versions prior to 17.2R1-S7, 17.2R2-S6, 17.2R3; 17.2X75 versions prior to 17.2X75-D102, 17.2X75-D110; 17.3 versions prior to 17.3R2-S4, 17.3R3; 17.4 versions prior to 17.4R1-S5, 17.4R2; 18.1 versions prior to 18.1R2-S3, 18.1R3;"
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
          }
        ],
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400 Uncontrolled Resource Consumption"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105564",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105564"
            },
            {
              "name": "1041849",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1041849"
            },
            {
              "name": "https://kb.juniper.net/JSA10882",
              "refsource": "CONFIRM",
              "url": "https://kb.juniper.net/JSA10882"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "The following software releases have been updated to resolve this specific issue: 17.2R1-S7, 17.2R2-S6, 17.2R3, 17.2X75-D102, 17.2X75-D110, 17.3R2-S4, 17.3R3, 17.4R1-S5, 17.4R2, 18.1R2-S3, 18.1R3, 18.2R1, 18.2X75-D10, 18.3R1, and all subsequent releases."
          }
        ],
        "source": {
          "advisory": "JSA10882",
          "defect": [
            "1344177"
          ],
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "There are no viable workarounds for this issue."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2018-0048",
    "datePublished": "2018-10-10T18:00:00.000Z",
    "dateReserved": "2017-11-16T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:03:41.025Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-0086 (GCVE-0-2018-0086)

Vulnerability from cvelistv5 – Published: 2018-01-18 06:00 – Updated: 2024-12-02 21:46
VLAI
Summary
A vulnerability in the application server of the Cisco Unified Customer Voice Portal (CVP) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the affected device. The vulnerability is due to malformed SIP INVITE traffic received on the CVP during communications with the Cisco Virtualized Voice Browser (VVB). An attacker could exploit this vulnerability by sending malformed SIP INVITE traffic to the targeted appliance. An exploit could allow the attacker to impact the availability of services and data on the device, causing a DoS condition. This vulnerability affects Cisco Unified CVP running any software release prior to 11.6(1). Cisco Bug IDs: CSCve85840.
Severity
No CVSS data available.
CWE
Assigner
References
URL Tags
http://www.securitytracker.com/id/1040220 vdb-entryx_refsource_SECTRACK
http://www.securityfocus.com/bid/102745 vdb-entryx_refsource_BID
https://tools.cisco.com/security/center/content/C… x_refsource_CONFIRM
Impacted products
Vendor Product Version
n/a Cisco Unified Customer Voice Portal Affected: Cisco Unified Customer Voice Portal
Date Public
2018-01-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T03:14:16.599Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "1040220",
            "tags": [
              "vdb-entry",
              "x_refsource_SECTRACK",
              "x_transferred"
            ],
            "url": "http://www.securitytracker.com/id/1040220"
          },
          {
            "name": "102745",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/102745"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-cvp"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2018-0086",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-02T19:11:53.386981Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-02T21:46:25.517Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Cisco Unified Customer Voice Portal",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Cisco Unified Customer Voice Portal"
            }
          ]
        }
      ],
      "datePublic": "2018-01-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability in the application server of the Cisco Unified Customer Voice Portal (CVP) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the affected device. The vulnerability is due to malformed SIP INVITE traffic received on the CVP during communications with the Cisco Virtualized Voice Browser (VVB). An attacker could exploit this vulnerability by sending malformed SIP INVITE traffic to the targeted appliance. An exploit could allow the attacker to impact the availability of services and data on the device, causing a DoS condition. This vulnerability affects Cisco Unified CVP running any software release prior to 11.6(1). Cisco Bug IDs: CSCve85840."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-01-23T10:57:01.000Z",
        "orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
        "shortName": "cisco"
      },
      "references": [
        {
          "name": "1040220",
          "tags": [
            "vdb-entry",
            "x_refsource_SECTRACK"
          ],
          "url": "http://www.securitytracker.com/id/1040220"
        },
        {
          "name": "102745",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/102745"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-cvp"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@cisco.com",
          "ID": "CVE-2018-0086",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Cisco Unified Customer Voice Portal",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Cisco Unified Customer Voice Portal"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability in the application server of the Cisco Unified Customer Voice Portal (CVP) could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on the affected device. The vulnerability is due to malformed SIP INVITE traffic received on the CVP during communications with the Cisco Virtualized Voice Browser (VVB). An attacker could exploit this vulnerability by sending malformed SIP INVITE traffic to the targeted appliance. An exploit could allow the attacker to impact the availability of services and data on the device, causing a DoS condition. This vulnerability affects Cisco Unified CVP running any software release prior to 11.6(1). Cisco Bug IDs: CSCve85840."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-400"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "1040220",
              "refsource": "SECTRACK",
              "url": "http://www.securitytracker.com/id/1040220"
            },
            {
              "name": "102745",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/102745"
            },
            {
              "name": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-cvp",
              "refsource": "CONFIRM",
              "url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20180117-cvp"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
    "assignerShortName": "cisco",
    "cveId": "CVE-2018-0086",
    "datePublished": "2018-01-18T06:00:00.000Z",
    "dateReserved": "2017-11-27T00:00:00.000Z",
    "dateUpdated": "2024-12-02T21:46:25.517Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Design throttling mechanisms into the system architecture. The best protection is to limit the amount of resources that an unauthorized user can cause to be expended. A strong authentication and access control model will help prevent such attacks from occurring in the first place. The login application should be protected against DoS attacks as much as possible. Limiting the database access, perhaps by caching result sets, can help minimize the resources expended. To further limit the potential for a DoS attack, consider tracking the rate of requests received from users and blocking requests that exceed a defined rate threshold.
Mitigation

Phase: Architecture and Design

Description:

  • Mitigation of resource exhaustion attacks requires that the target system either:
  • The first of these solutions is an issue in itself though, since it may allow attackers to prevent the use of the system by a particular valid user. If the attacker impersonates the valid user, they may be able to prevent the user from accessing the server in question.
  • The second solution is simply difficult to effectively institute -- and even when properly done, it does not provide a full solution. It simply makes the attack require more resources on the part of the attacker.
  • recognizes the attack and denies that user further access for a given amount of time, or
  • uniformly throttles all requests in order to make it more difficult to consume resources more quickly than they can again be freed.
Mitigation

Phase: Architecture and Design

Description:

  • Ensure that protocols have specific limits of scale placed on them.
Mitigation

Phase: Implementation

Description:

  • Ensure that all failures in resource allocation place the system into a safe posture.
CAPEC-147: XML Ping of the Death

An attacker initiates a resource depletion attack where a large number of small XML messages are delivered at a sufficiently rapid rate to cause a denial of service or crash of the target. Transactions such as repetitive SOAP transactions can deplete resources faster than a simple flooding attack because of the additional resources used by the SOAP protocol and the resources necessary to process SOAP messages. The transactions used are immaterial as long as they cause resource utilization on the target. In other words, this is a normal flooding attack augmented by using messages that will require extra processing on the target.

CAPEC-227: Sustained Client Engagement

An adversary attempts to deny legitimate users access to a resource by continually engaging a specific resource in an attempt to keep the resource tied up as long as possible. The adversary's primary goal is not to crash or flood the target, which would alert defenders; rather it is to repeatedly perform actions or abuse algorithmic flaws such that a given resource is tied up and not available to a legitimate user. By carefully crafting a requests that keep the resource engaged through what is seemingly benign requests, legitimate users are limited or completely denied access to the resource.

CAPEC-492: Regular Expression Exponential Blowup

An adversary may execute an attack on a program that uses a poor Regular Expression(Regex) implementation by choosing input that results in an extreme situation for the Regex. A typical extreme situation operates at exponential time compared to the input size. This is due to most implementations using a Nondeterministic Finite Automaton(NFA) state machine to be built by the Regex algorithm since NFA allows backtracking and thus more complex regular expressions.

Back to CWE stats page