CWE-321

Use of Hard-coded Cryptographic Key

The product uses a hard-coded, unchangeable cryptographic key.

CVE-2020-28391 (GCVE-0-2020-28391)

Vulnerability from cvelistv5 – Published: 2021-01-12 00:00 – Updated: 2024-08-04 16:33
VLAI
Summary
A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions < V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions < V5.5.0), SCALANCE X-200RNA switch family (All versions < V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.106Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200 switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.2.5"
            }
          ]
        },
        {
          "product": "SCALANCE X-200IRT switch family (incl. SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.5.0"
            }
          ]
        },
        {
          "product": "SCALANCE X-200RNA switch family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200 switch family (incl. SIPLUS NET variants) (All versions \u003c V5.2.5), SCALANCE X-200IRT switch family (incl. SIPLUS NET variants) (All versions \u003c V5.5.0), SCALANCE X-200RNA switch family (All versions \u003c V3.2.7). Devices create a new unique key upon factory reset, except when used with C-PLUG. When used with C-PLUG the devices use the hardcoded private RSA-key shipped with the firmware-image. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28391",
    "datePublished": "2021-01-12T00:00:00.000Z",
    "dateReserved": "2020-11-10T00:00:00.000Z",
    "dateUpdated": "2024-08-04T16:33:59.106Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-28395 (GCVE-0-2020-28395)

Vulnerability from cvelistv5 – Published: 2021-01-12 00:00 – Updated: 2024-08-04 16:33
VLAI
Summary
A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions < V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions < V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T16:33:59.028Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X-200RNA switch family",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.2.7"
            }
          ]
        },
        {
          "product": "SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X-200RNA switch family (All versions \u003c V3.2.7), SCALANCE X-300 switch family (incl. X408 and SIPLUS NET variants) (All versions \u003c V4.1.0). Devices do not create a new unique private key after factory reset. An attacker could leverage this situation to a man-in-the-middle situation and decrypt previously captured traffic."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-13T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-274900.pdf"
        },
        {
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-012-02"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2020-28395",
    "datePublished": "2021-01-12T00:00:00.000Z",
    "dateReserved": "2020-11-10T00:00:00.000Z",
    "dateUpdated": "2024-08-04T16:33:59.028Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6979 (GCVE-0-2020-6979)

Vulnerability from cvelistv5 – Published: 2020-03-24 20:21 – Updated: 2024-08-04 09:18
VLAI
Summary
In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Moxa EDS-G516E Series firmware, Version 5.2 or lower Affected: Moxa EDS-G516E Series firmware, Version 5.2 or lower
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.445Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-24T20:21:41.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6979",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa EDS-G516E Series firmware, Version 5.2 or lower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Moxa EDS-G516E Series firmware, Version 5.2 or lower"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Moxa EDS-G516E Series firmware, Version 5.2 or lower, the affected products use a hard-coded cryptographic key, increasing the possibility that confidential data can be recovered."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-04"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6979",
    "datePublished": "2020-03-24T20:21:41.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:02.445Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6983 (GCVE-0-2020-6983)

Vulnerability from cvelistv5 – Published: 2020-03-24 18:57 – Updated: 2024-08-04 09:18
VLAI
Summary
In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower Affected: Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.537Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-24T18:57:14.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6983",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Moxa PT-7528 series firmware, Version 4.0 or lower, PT-7828 series firmware, Version 3.9 or lower"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Moxa PT-7528 series firmware, Version 4.0 or lower, and PT-7828 series firmware, Version 3.9 or lower, the affected products use a hard-coded cryptographic key, which increases the possibility that confidential data can be recovered."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6983",
    "datePublished": "2020-03-24T18:57:14.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:02.537Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6990 (GCVE-0-2020-6990)

Vulnerability from cvelistv5 – Published: 2020-03-16 15:39 – Updated: 2024-08-04 09:18
VLAI
Summary
Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller.
Severity
No CVSS data available.
CWE
  • CWE-321 - USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321
Assigner
References
Impacted products
Vendor Product Version
n/a Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior Affected: Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.522Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-16T15:39:45.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6990",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Rockwell Automation MicroLogix 1400 Controllers Series B v21.001 and prior, Series A, all versions, MicroLogix 1100 Controller, all versions, RSLogix 500 Software v12.001 and prior, The cryptographic key utilized to help protect the account password is hard coded into the RSLogix 500 binary file. An attacker could identify cryptographic keys and use it for further cryptographic attacks that could ultimately lead to a remote attacker gaining unauthorized access to the controller."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "USE OF HARD-CODED CRYPTOGRAPHIC KEY CWE-321"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-070-06"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6990",
    "datePublished": "2020-03-16T15:39:45.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:02.522Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7846 (GCVE-0-2020-7846)

Vulnerability from cvelistv5 – Published: 2021-02-24 15:46 – Updated: 2024-08-04 09:41
VLAI
Summary
Helpcom before v10.0 contains a file download and execution vulnerability caused by storing hardcoded cryptographic key. It finally leads to a file download and execution via access to crafted web page.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Cnesty Helpcom Affected: < 10.0
Create a notification for this product.
Credits
Jeongun Baek
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:41:01.885Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35919"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Helpcom",
          "vendor": "Cnesty",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 10.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Jeongun Baek"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Helpcom before v10.0 contains a file download and execution vulnerability caused by storing hardcoded cryptographic key. It finally leads to a file download and execution via access to crafted web page."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-02-24T15:46:51.000Z",
        "orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
        "shortName": "krcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35919"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vuln@krcert.or.kr",
          "ID": "CVE-2020-7846",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Helpcom",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "\u003c 10.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Cnesty"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Jeongun Baek"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Helpcom before v10.0 contains a file download and execution vulnerability caused by storing hardcoded cryptographic key. It finally leads to a file download and execution via access to crafted web page."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35919",
              "refsource": "CONFIRM",
              "url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35919"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
    "assignerShortName": "krcert",
    "cveId": "CVE-2020-7846",
    "datePublished": "2021-02-24T15:46:51.000Z",
    "dateReserved": "2020-01-22T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:41:01.885Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-0266 (GCVE-0-2021-0266)

Vulnerability from cvelistv5 – Published: 2021-04-22 19:37 – Updated: 2024-09-17 03:13
VLAI
Title
cSRX: Use of Hard-coded Cryptographic Keys allows an attacker to take control of the device through device management services.
Summary
The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Keys
Assigner
References
URL Tags
https://kb.juniper.net/JSA11157 x_refsource_MISC
Impacted products
Vendor Product Version
Juniper Networks Junos OS Affected: unspecified , < 20.2R3 (custom)
Affected: 20.3 , < 20.3R2 (custom)
Affected: 20.4 , < 20.4R2 (custom)
Create a notification for this product.
Date Public
2021-04-14 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T15:32:10.505Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://kb.juniper.net/JSA11157"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "cSRX Series"
          ],
          "product": "Junos OS",
          "vendor": "Juniper Networks",
          "versions": [
            {
              "lessThan": "20.2R3",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            },
            {
              "lessThan": "20.3R2",
              "status": "affected",
              "version": "20.3",
              "versionType": "custom"
            },
            {
              "lessThan": "20.4R2",
              "status": "affected",
              "version": "20.4",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-04-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2."
        }
      ],
      "exploits": [
        {
          "lang": "en",
          "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Keys",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T19:37:23.000Z",
        "orgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
        "shortName": "juniper"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://kb.juniper.net/JSA11157"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "The following software releases have been updated to resolve this specific issue: 20.2R3, 20.3R2, 20.4R2, 21.1R1, and all subsequent releases."
        }
      ],
      "source": {
        "advisory": "JSA11157",
        "defect": [
          "1564611"
        ],
        "discovery": "INTERNAL"
      },
      "title": "cSRX: Use of Hard-coded Cryptographic Keys allows an attacker to take control of the device through device management services.",
      "workarounds": [
        {
          "lang": "en",
          "value": "There are no viable workarounds for this issue. \n\nTo reduce the risk of exploitation of this issue, use access lists or firewall filters to limit access to the cSRX instance to only trusted administrative networks, hosts and users."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "sirt@juniper.net",
          "DATE_PUBLIC": "2021-04-14T16:00:00.000Z",
          "ID": "CVE-2021-0266",
          "STATE": "PUBLIC",
          "TITLE": "cSRX: Use of Hard-coded Cryptographic Keys allows an attacker to take control of the device through device management services."
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Junos OS",
                      "version": {
                        "version_data": [
                          {
                            "platform": "cSRX Series",
                            "version_affected": "\u003c",
                            "version_value": "20.2R3"
                          },
                          {
                            "platform": "cSRX Series",
                            "version_affected": "\u003c",
                            "version_name": "20.3",
                            "version_value": "20.3R2"
                          },
                          {
                            "platform": "cSRX Series",
                            "version_affected": "\u003c",
                            "version_name": "20.4",
                            "version_value": "20.4R2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Juniper Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The use of multiple hard-coded cryptographic keys in cSRX Series software in Juniper Networks Junos OS allows an attacker to take control of any instance of a cSRX deployment through device management services. This issue affects: Juniper Networks Junos OS on cSRX Series: All versions prior to 20.2R3; 20.3 versions prior to 20.3R2; 20.4 versions prior to 20.4R2."
            }
          ]
        },
        "exploit": [
          {
            "lang": "en",
            "value": "Juniper SIRT is not aware of any malicious exploitation of this vulnerability."
          }
        ],
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Keys"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://kb.juniper.net/JSA11157",
              "refsource": "MISC",
              "url": "https://kb.juniper.net/JSA11157"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "The following software releases have been updated to resolve this specific issue: 20.2R3, 20.3R2, 20.4R2, 21.1R1, and all subsequent releases."
          }
        ],
        "source": {
          "advisory": "JSA11157",
          "defect": [
            "1564611"
          ],
          "discovery": "INTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "There are no viable workarounds for this issue. \n\nTo reduce the risk of exploitation of this issue, use access lists or firewall filters to limit access to the cSRX instance to only trusted administrative networks, hosts and users."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8cbe9d5a-a066-4c94-8978-4b15efeae968",
    "assignerShortName": "juniper",
    "cveId": "CVE-2021-0266",
    "datePublished": "2021-04-22T19:37:23.655Z",
    "dateReserved": "2020-10-27T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:13:48.705Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-23842 (GCVE-0-2021-23842)

Vulnerability from cvelistv5 – Published: 2022-01-19 20:38 – Updated: 2024-09-16 21:56
VLAI
Title
Use of Hard-coded Cryptographic Key
Summary
Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\'s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Bosch AMS Affected: unspecified , < 4.0 (custom)
Create a notification for this product.
Bosch APE Affected: unspecified , ≤ 3.8.x (custom)
Create a notification for this product.
Bosch BIS Affected: unspecified , < 4.9.1 (custom)
Create a notification for this product.
Bosch AMC2 Affected: all
Create a notification for this product.
Date Public
2022-01-19 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T19:14:09.336Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "AMS",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "4.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "APE",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.8.x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "BIS",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThan": "4.9.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "AMC2",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "all"
            }
          ]
        }
      ],
      "datePublic": "2022-01-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-01-19T20:38:54.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-940448-BT",
        "discovery": "EXTERNAL"
      },
      "title": "Use of Hard-coded Cryptographic Key",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2022-01-19",
          "ID": "CVE-2021-23842",
          "STATE": "PUBLIC",
          "TITLE": "Use of Hard-coded Cryptographic Key"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "AMS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.0"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "APE",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "3.8.x"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "BIS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "4.9.1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "AMC2",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "all"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Communication to the AMC2 uses a state-of-the-art cryptographic algorithm for symmetric encryption called Blowfish. An attacker could retrieve the key from the firmware to decrypt network traffic between the AMC2 and the host system. Thus, an attacker can exploit this vulnerability to decrypt and modify network traffic, decrypt and further investigate the device\\\u0027s firmware file, and change the device configuration. The attacker needs to have access to the local network, typically even the same subnet."
            }
          ]
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.7,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-940448-BT.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-940448-BT",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2021-23842",
    "datePublished": "2022-01-19T20:38:54.368Z",
    "dateReserved": "2021-01-12T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:56:51.896Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27389 (GCVE-0-2021-27389)

Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:48
VLAI
Summary
A vulnerability has been identified in Opcenter Quality (All versions < V12.2), QMS Automotive (All versions < V12.30). A private sign key is shipped with the product without adequate protection.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Impacted products
Vendor Product Version
Siemens Opcenter Quality Affected: All versions < V12.2
Create a notification for this product.
Siemens QMS Automotive Affected: All versions < V12.30
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.625Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Opcenter Quality",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.2"
            }
          ]
        },
        {
          "product": "QMS Automotive",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V12.30"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V12.2), QMS Automotive (All versions \u003c V12.30). A private sign key is shipped with the product without adequate protection."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T20:42:21.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27389",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Opcenter Quality",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "QMS Automotive",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V12.30"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Opcenter Quality (All versions \u003c V12.2), QMS Automotive (All versions \u003c V12.30). A private sign key is shipped with the product without adequate protection."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27389",
    "datePublished": "2021-04-22T20:42:21.000Z",
    "dateReserved": "2021-02-18T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:48:16.625Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27392 (GCVE-0-2021-27392)

Vulnerability from cvelistv5 – Published: 2021-04-22 20:42 – Updated: 2024-08-03 20:48
VLAI
Summary
A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server.
Severity
No CVSS data available.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:16.928Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2020 R3"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2020 R2"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2020 R1"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2019 R3"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2019 R2"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2019 R1"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2018 R3"
            }
          ]
        },
        {
          "product": "Siveillance Video Open Network Bridge",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "2018 R2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321: Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-04-22T20:42:21.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2021-27392",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2020 R3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2020 R2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2020 R1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2019 R3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2019 R2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2019 R1"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2018 R3"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Siveillance Video Open Network Bridge",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2018 R2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in Siveillance Video Open Network Bridge (2020 R3), Siveillance Video Open Network Bridge (2020 R2), Siveillance Video Open Network Bridge (2020 R1), Siveillance Video Open Network Bridge (2019 R3), Siveillance Video Open Network Bridge (2019 R2), Siveillance Video Open Network Bridge (2019 R1), Siveillance Video Open Network Bridge (2018 R3), Siveillance Video Open Network Bridge (2018 R2). Affected Open Network Bridges store user credentials for the authentication between ONVIF clients and ONVIF server using a hard-coded key. The encrypted credentials can be retrieved via the MIP SDK. This could allow an authenticated remote attacker to retrieve and decrypt all credentials stored on the ONVIF server."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321: Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2021-27392",
    "datePublished": "2021-04-22T20:42:21.000Z",
    "dateReserved": "2021-02-18T00:00:00.000Z",
    "dateUpdated": "2024-08-03T20:48:16.928Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Prevention schemes mirror that of hard-coded password storage.

No CAPEC attack patterns related to this CWE.

Back to CWE stats page