CWE-312

Cleartext Storage of Sensitive Information

The product stores sensitive information in cleartext within a resource that might be accessible to another control sphere.

CVE-2018-16498 (GCVE-0-2018-16498)

Vulnerability from cvelistv5 – Published: 2021-05-26 18:45 – Updated: 2024-08-05 10:24
VLAI
Summary
In Versa Director, the unencrypted backup files stored on the Versa deployment contain credentials stored within configuration files. These credentials are for various application components such as SNMP, and SSL and Trust keystores.
Severity
No CVSS data available.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information (CWE-312)
Assigner
References
URL Tags
https://hackerone.com/reports/1168195 x_refsource_MISC
Impacted products
Vendor Product Version
n/a Versa Director Affected: Fixed Versions: 16.1R2S11, 20.2.2, 21.1.1, 21.2.1
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T10:24:32.800Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://hackerone.com/reports/1168195"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Versa Director",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Fixed Versions: 16.1R2S11, 20.2.2, 21.1.1, 21.2.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Versa Director, the unencrypted backup files stored on the Versa deployment contain credentials stored within configuration files. These credentials are for various application components such as SNMP, and SSL and Trust keystores."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext Storage of Sensitive Information (CWE-312)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-05-26T18:45:50.000Z",
        "orgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
        "shortName": "hackerone"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://hackerone.com/reports/1168195"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "support@hackerone.com",
          "ID": "CVE-2018-16498",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Versa Director",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Fixed Versions: 16.1R2S11, 20.2.2, 21.1.1, 21.2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Versa Director, the unencrypted backup files stored on the Versa deployment contain credentials stored within configuration files. These credentials are for various application components such as SNMP, and SSL and Trust keystores."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Cleartext Storage of Sensitive Information (CWE-312)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://hackerone.com/reports/1168195",
              "refsource": "MISC",
              "url": "https://hackerone.com/reports/1168195"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "36234546-b8fa-4601-9d6f-f4e334aa8ea1",
    "assignerShortName": "hackerone",
    "cveId": "CVE-2018-16498",
    "datePublished": "2021-05-26T18:45:50.000Z",
    "dateReserved": "2018-09-04T00:00:00.000Z",
    "dateUpdated": "2024-08-05T10:24:32.800Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-19009 (GCVE-0-2018-19009)

Vulnerability from cvelistv5 – Published: 2019-01-25 20:00 – Updated: 2024-09-16 23:21
VLAI
Summary
Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device.
Severity
No CVSS data available.
CWE
  • CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
Assigner
References
Impacted products
Vendor Product Version
Pilz Pilz PNOZmulti Configurator Affected: All versions prior to version 10.9
Create a notification for this product.
Date Public
2019-01-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:23:09.032Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03"
          },
          {
            "name": "106529",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106529"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Pilz PNOZmulti Configurator",
          "vendor": "Pilz",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 10.9"
            }
          ]
        }
      ],
      "datePublic": "2019-01-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-01-26T10:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03"
        },
        {
          "name": "106529",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106529"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-01-10T00:00:00",
          "ID": "CVE-2018-19009",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Pilz PNOZmulti Configurator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 10.9"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Pilz"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Pilz PNOZmulti Configurator prior to version 10.9 allows an authenticated attacker with local access to the system containing the PNOZmulti Configurator software to view sensitive credential data in clear-text. This sensitive data is applicable to only the PMI m107 diag HMI device. An attacker with access to this sensitive data and physical access to the PMI m107 diag can modify data on the HMI device."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-010-03"
            },
            {
              "name": "106529",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106529"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-19009",
    "datePublished": "2019-01-25T20:00:00.000Z",
    "dateReserved": "2018-11-06T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:21:02.043Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-14825 (GCVE-0-2019-14825)

Vulnerability from cvelistv5 – Published: 2019-11-25 00:00 – Updated: 2024-08-05 00:26
VLAI
Summary
A cleartext password storage issue was discovered in Katello, versions 3.x.x.x before katello 3.12.0.9. Registry credentials used during container image discovery were inadvertently logged without being masked. This flaw could expose the registry credentials to other privileged users.
CWE
Assigner
Impacted products
Vendor Product Version
Red Hat katello Affected: katello versions 3.x.x.x before katello 3.12.0.9
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:26:39.129Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14825"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "katello",
          "vendor": "Red Hat",
          "versions": [
            {
              "status": "affected",
              "version": "katello versions 3.x.x.x before katello 3.12.0.9"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A cleartext password storage issue was discovered in Katello, versions 3.x.x.x before katello 3.12.0.9. Registry credentials used during container image discovery were inadvertently logged without being masked. This flaw could expose the registry credentials to other privileged users."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:N/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-07T00:00:00.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14825"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2019-14825",
    "datePublished": "2019-11-25T00:00:00.000Z",
    "dateReserved": "2019-08-10T00:00:00.000Z",
    "dateUpdated": "2024-08-05T00:26:39.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-14886 (GCVE-0-2019-14886)

Vulnerability from cvelistv5 – Published: 2020-03-05 00:00 – Updated: 2024-08-05 00:26
VLAI
Summary
A vulnerability was found in business-central, as shipped in rhdm-7.5.1 and rhpam-7.5.1, where encoded passwords are stored in errai_security_context. The encoding used for storing the passwords is Base64, not an encryption algorithm, and any recovery of these passwords could lead to user passwords being exposed.
CWE
Assigner
Impacted products
Vendor Product Version
Red Hat Business-central Affected: versions of Business-central as shipped in rhdm-7.5.1 and rhpam-7.5.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:26:39.178Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14886"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://groups.google.com/forum/?utm_medium=email\u0026utm_source=footer#%21msg/jbpm-usage/74pSuwfGKRU/0oXpmRScBQAJ"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Business-central",
          "vendor": "Red Hat",
          "versions": [
            {
              "status": "affected",
              "version": "versions of Business-central as shipped in rhdm-7.5.1 and rhpam-7.5.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in business-central, as shipped in rhdm-7.5.1 and rhpam-7.5.1, where encoded passwords are stored in errai_security_context. The encoding used for storing the passwords is Base64, not an encryption algorithm, and any recovery of these passwords could lead to user passwords being exposed."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 4.6,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-07T00:00:00.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14886"
        },
        {
          "url": "https://groups.google.com/forum/?utm_medium=email\u0026utm_source=footer#%21msg/jbpm-usage/74pSuwfGKRU/0oXpmRScBQAJ"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2019-14886",
    "datePublished": "2020-03-05T00:00:00.000Z",
    "dateReserved": "2019-08-10T00:00:00.000Z",
    "dateUpdated": "2024-08-05T00:26:39.178Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-14890 (GCVE-0-2019-14890)

Vulnerability from cvelistv5 – Published: 2019-11-26 06:46 – Updated: 2024-08-05 00:26
VLAI
Summary
A vulnerability was found in Ansible Tower before 3.6.1 where an attacker with low privilege could retrieve usernames and passwords credentials from the new RHSM saved in plain text into the database at '/api/v2/config' when applying the Ansible Tower license.
CWE
Assigner
References
Impacted products
Vendor Product Version
[UNKNOWN] Tower Affected: 3.6.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T00:26:39.098Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Tower",
          "vendor": "[UNKNOWN]",
          "versions": [
            {
              "status": "affected",
              "version": "3.6.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in Ansible Tower before 3.6.1 where an attacker with low privilege could retrieve usernames and passwords credentials from the new RHSM saved in plain text into the database at \u0027/api/v2/config\u0027 when applying the Ansible Tower license."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-12-02T14:17:50.000Z",
        "orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
        "shortName": "redhat"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secalert@redhat.com",
          "ID": "CVE-2019-14890",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Tower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "3.6.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "[UNKNOWN]"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in Ansible Tower before 3.6.1 where an attacker with low privilege could retrieve usernames and passwords credentials from the new RHSM saved in plain text into the database at \u0027/api/v2/config\u0027 when applying the Ansible Tower license."
            }
          ]
        },
        "impact": {
          "cvss": [
            [
              {
                "vectorString": "8.4/CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:N",
                "version": "3.0"
              }
            ]
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890",
              "refsource": "CONFIRM",
              "url": "https://bugzilla.redhat.com/show_bug.cgi?id=CVE-2019-14890"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
    "assignerShortName": "redhat",
    "cveId": "CVE-2019-14890",
    "datePublished": "2019-11-26T06:46:17.000Z",
    "dateReserved": "2019-08-10T00:00:00.000Z",
    "dateUpdated": "2024-08-05T00:26:39.098Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-18238 (GCVE-0-2019-18238)

Vulnerability from cvelistv5 – Published: 2020-02-26 21:19 – Updated: 2024-08-05 01:47
VLAI
Summary
In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account.
Severity
No CVSS data available.
CWE
  • CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
Assigner
References
Impacted products
Vendor Product Version
n/a Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower Affected: Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T01:47:14.071Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-24T16:45:16.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-18238",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Moxa ioLogik 2500 series firmware, Version 3.0 or lower, IOxpress configuration utility, Version 2.3.0 or lower"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In Moxa ioLogik 2500 series firmware, Version 3.0 or lower, and IOxpress configuration utility, Version 2.3.0 or lower, sensitive information is stored in configuration files without encryption, which may allow an attacker to access an administrative account."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsa-20-056-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-18238",
    "datePublished": "2020-02-26T21:19:56.000Z",
    "dateReserved": "2019-10-22T00:00:00.000Z",
    "dateUpdated": "2024-08-05T01:47:14.071Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-25279 (GCVE-0-2019-25279)

Vulnerability from cvelistv5 – Published: 2026-01-07 23:10 – Updated: 2026-01-16 18:59
VLAI
Title
FaceSentry Access Control System 6.4.8 Cleartext Password Storage Vulnerability
Summary
FaceSentry Access Control System 6.4.8 contains a cleartext password storage vulnerability that allows attackers to access unencrypted credentials in the device's SQLite database. Attackers can directly read sensitive login information stored in /faceGuard/database/FaceSentryWeb.sqlite without additional authentication.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
Impacted products
Vendor Product Version
iWT Ltd. FaceSentry Access Control System Affected: 6.4.8 build 264
Affected: 5.7.2 build 568
Affected: 5.7.0 build 539
Create a notification for this product.
Date Public
2019-06-30 00:00
Credits
LiquidWorm as Gjoko Krstic of Zero Science Lab
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2019-25279",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-08T19:25:26.147172Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-08T19:25:30.795Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "FaceSentry Access Control System",
          "vendor": "iWT Ltd.",
          "versions": [
            {
              "status": "affected",
              "version": "6.4.8 build 264"
            },
            {
              "status": "affected",
              "version": "5.7.2 build 568"
            },
            {
              "status": "affected",
              "version": "5.7.0 build 539"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "LiquidWorm as Gjoko Krstic of Zero Science Lab"
        }
      ],
      "datePublic": "2019-06-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "FaceSentry Access Control System 6.4.8 contains a cleartext password storage vulnerability that allows attackers to access unencrypted credentials in the device\u0027s SQLite database. Attackers can directly read sensitive login information stored in /faceGuard/database/FaceSentryWeb.sqlite without additional authentication."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 6.8,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS"
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-16T18:59:58.793Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "name": "Zero Science Lab Vulnerability Advisory",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.zeroscience.mk/en/vulnerabilities/ZSL-2019-5529.php"
        },
        {
          "name": "IBM X-Force Exchange Vulnerability Entry",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/163190"
        },
        {
          "name": "Packet Storm Security Exploit Entry",
          "tags": [
            "exploit"
          ],
          "url": "https://packetstormsecurity.com/files/153501"
        }
      ],
      "title": "FaceSentry Access Control System 6.4.8 Cleartext Password Storage Vulnerability",
      "x_generator": {
        "engine": "vulncheck"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2019-25279",
    "datePublished": "2026-01-07T23:10:00.907Z",
    "dateReserved": "2026-01-06T16:07:08.526Z",
    "dateUpdated": "2026-01-16T18:59:58.793Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2019-3753 (GCVE-0-2019-3753)

Vulnerability from cvelistv5 – Published: 2019-08-20 18:47 – Updated: 2024-09-16 20:48
VLAI
Summary
Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Vendor Product Version
Dell EMC PowerConnect 8024 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect 7000 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M6348 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M6220 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M8024 Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Dell EMC PowerConnect M8024-K Affected: unspecified , < 5.1.15.2 (custom)
Create a notification for this product.
Date Public
2019-08-16 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:19:18.453Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/article/sln318359/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerConnect 8024",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect 7000",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect M6348",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect M6220",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect M8024",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "PowerConnect  M8024-K",
          "vendor": "Dell EMC",
          "versions": [
            {
              "lessThan": "5.1.15.2",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2019-08-16T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312 Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-08-20T18:47:01.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.dell.com/support/article/sln318359/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.0.7"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2019-08-16T04:00:00.000Z",
          "ID": "CVE-2019-3753",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerConnect 8024",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect 7000",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect M6348",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect M6220",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect M8024",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "PowerConnect  M8024-K",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "5.1.15.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell EMC"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC PowerConnect 8024, 7000, M6348, M6220, M8024 and M8024-K running firmware versions prior to 5.1.15.2 contain a plain-text password storage vulnerability. TACACS\\Radius credentials are stored in plain text in the system settings menu. An authenticated malicious user with access to the system settings menu may obtain the exposed password to use it in further attacks."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.7"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312 Cleartext Storage of Sensitive Information"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/article/sln318359/",
              "refsource": "CONFIRM",
              "url": "https://www.dell.com/support/article/sln318359/"
            }
          ]
        },
        "source": {
          "discovery": "UNKNOWN"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2019-3753",
    "datePublished": "2019-08-20T18:47:01.835Z",
    "dateReserved": "2019-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:48:15.827Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-3937 (GCVE-0-2019-3937)

Vulnerability from cvelistv5 – Published: 2019-04-30 20:38 – Updated: 2024-08-04 19:26
VLAI
Summary
Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
Crestron Crestron AirMedia Affected: AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T19:26:27.781Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2019-20"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Crestron AirMedia",
          "vendor": "Crestron",
          "versions": [
            {
              "status": "affected",
              "version": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-04-30T20:38:24.000Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2019-20"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2019-3937",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Crestron AirMedia",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "AM-100 firmware 1.6.0.2 and AM-101 firmware 2.7.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Crestron"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Crestron AM-100 with firmware 1.6.0.2 and AM-101 with firmware 2.7.0.2 stores usernames, passwords, slideshow passcode, and other configuration options in cleartext in the file /tmp/scfgdndf. A local attacker can use this vulnerability to recover sensitive data."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-312: Cleartext Storage"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2019-20",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2019-20"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2019-3937",
    "datePublished": "2019-04-30T20:38:24.000Z",
    "dateReserved": "2019-01-03T00:00:00.000Z",
    "dateUpdated": "2024-08-04T19:26:27.781Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-6549 (GCVE-0-2019-6549)

Vulnerability from cvelistv5 – Published: 2019-02-12 18:00 – Updated: 2024-09-16 22:30
VLAI
Summary
An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP.
Severity
No CVSS data available.
CWE
  • CWE-312 - CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312
Assigner
References
Impacted products
Vendor Product Version
ICS-CERT PR100088 Modbus gateway Affected: All versions prior to Release R02 (or Software Version 1.1.13166)
Create a notification for this product.
Date Public
2019-02-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T20:23:21.488Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PR100088 Modbus gateway",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to Release R02 (or Software Version 1.1.13166)"
            }
          ]
        }
      ],
      "datePublic": "2019-02-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-12T17:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-02-05T00:00:00",
          "ID": "CVE-2019-6549",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PR100088 Modbus gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to Release R02 (or Software Version 1.1.13166)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An attacker could retrieve plain-text credentials stored in a XML file on PR100088 Modbus gateway versions prior to Release R02 (or Software Version 1.1.13166) through FTP."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CLEARTEXT STORAGE OF SENSITIVE INFORMATION CWE-312"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-036-05"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-6549",
    "datePublished": "2019-02-12T18:00:00.000Z",
    "dateReserved": "2019-01-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:30:41.714Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phases: Implementation, System Configuration, Operation

Description:

  • When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to encrypt the data at rest. [REF-1297] [REF-1299] [REF-1301]
Mitigation

Phases: Implementation, System Configuration, Operation

Description:

  • In some systems/environments such as cloud, the use of "double encryption" (at both the software and hardware layer) might be required, and the developer might be solely responsible for both layers, instead of shared responsibility with the administrator of the broader system/environment.
CAPEC-37: Retrieve Embedded Sensitive Data

An attacker examines a target system to find sensitive data that has been embedded within it. This information can reveal confidential contents, such as account numbers or individual keys/credentials that can be used as an intermediate step in a larger attack.

Back to CWE stats page