CWE-306
Missing Authentication for Critical Function
The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.
CVE-2022-22809 (GCVE-0-2022-22809)
Vulnerability from cvelistv5 – Published: 2022-02-09 00:00 – Updated: 2024-08-03 03:21- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior) |
Affected:
spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:21:49.171Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists that could allow modifications of the touch configurations in an unauthorized manner when an attacker attempts to modify the touch configurations. Affected Product: spaceLYnk (V2.6.2 and prior), Wiser for KNX (formerly homeLYnk) (V2.6.2 and prior), fellerLYnk (V2.6.2 and prior)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-17T00:00:00.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-04"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2022-22809",
"datePublished": "2022-02-09T00:00:00.000Z",
"dateReserved": "2022-01-07T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:21:49.171Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24396 (GCVE-0-2022-24396)
Vulnerability from cvelistv5 – Published: 2022-03-08 13:35 – Updated: 2024-08-03 04:07- CWE-306 - CWE-548
| URL | Tags |
|---|---|
| https://dam.sap.com/mac/embed/public/pdf/a/ucQrx6… | x_refsource_MISC |
| https://launchpad.support.sap.com/#/notes/3145987 | x_refsource_MISC |
| http://seclists.org/fulldisclosure/2022/Jun/38 | mailing-listx_refsource_FULLDISC |
| http://packetstormsecurity.com/files/167560/SAP-F… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| SAP SE | SAP Focused Run (Simple Diagnostics Agent) |
Affected:
< >= 1.0
Affected: < 1.58 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:07:02.528Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://dam.sap.com/mac/embed/public/pdf/a/ucQrx6G.htm?rc=10"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://launchpad.support.sap.com/#/notes/3145987"
},
{
"name": "20220621 # Onapsis Security Advisory 2022-0004: Missing Authentication check in SAP Focused Run (Simple Diagnostics Agent 1.0)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC",
"x_transferred"
],
"url": "http://seclists.org/fulldisclosure/2022/Jun/38"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/167560/SAP-FRUN-Simple-Diagnostics-Agent-1.0-Missing-Authentication.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SAP Focused Run (Simple Diagnostics Agent)",
"vendor": "SAP SE",
"versions": [
{
"status": "affected",
"version": "\u003c \u003e= 1.0"
},
{
"status": "affected",
"version": "\u003c 1.58"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Simple Diagnostics Agent - versions 1.0 up to version 1.57, does not perform any authentication checks for functionalities that can be accessed via localhost on http port 3005. Due to lack of authentication checks, an attacker could access administrative or other privileged functionalities and read, modify, or delete sensitive information and configurations."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306, CWE-548",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-21T21:06:21.000Z",
"orgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"shortName": "sap"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://dam.sap.com/mac/embed/public/pdf/a/ucQrx6G.htm?rc=10"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://launchpad.support.sap.com/#/notes/3145987"
},
{
"name": "20220621 # Onapsis Security Advisory 2022-0004: Missing Authentication check in SAP Focused Run (Simple Diagnostics Agent 1.0)",
"tags": [
"mailing-list",
"x_refsource_FULLDISC"
],
"url": "http://seclists.org/fulldisclosure/2022/Jun/38"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/167560/SAP-FRUN-Simple-Diagnostics-Agent-1.0-Missing-Authentication.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cna@sap.com",
"ID": "CVE-2022-24396",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SAP Focused Run (Simple Diagnostics Agent)",
"version": {
"version_data": [
{
"version_name": "\u003c",
"version_value": "\u003e= 1.0"
},
{
"version_name": "\u003c",
"version_value": "\u003c 1.58"
}
]
}
}
]
},
"vendor_name": "SAP SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Simple Diagnostics Agent - versions 1.0 up to version 1.57, does not perform any authentication checks for functionalities that can be accessed via localhost on http port 3005. Due to lack of authentication checks, an attacker could access administrative or other privileged functionalities and read, modify, or delete sensitive information and configurations."
}
]
},
"impact": {
"cvss": {
"baseScore": "null",
"vectorString": "null",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306, CWE-548"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://dam.sap.com/mac/embed/public/pdf/a/ucQrx6G.htm?rc=10",
"refsource": "MISC",
"url": "https://dam.sap.com/mac/embed/public/pdf/a/ucQrx6G.htm?rc=10"
},
{
"name": "https://launchpad.support.sap.com/#/notes/3145987",
"refsource": "MISC",
"url": "https://launchpad.support.sap.com/#/notes/3145987"
},
{
"name": "20220621 # Onapsis Security Advisory 2022-0004: Missing Authentication check in SAP Focused Run (Simple Diagnostics Agent 1.0)",
"refsource": "FULLDISC",
"url": "http://seclists.org/fulldisclosure/2022/Jun/38"
},
{
"name": "http://packetstormsecurity.com/files/167560/SAP-FRUN-Simple-Diagnostics-Agent-1.0-Missing-Authentication.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/167560/SAP-FRUN-Simple-Diagnostics-Agent-1.0-Missing-Authentication.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "e4686d1a-f260-4930-ac4c-2f5c992778dd",
"assignerShortName": "sap",
"cveId": "CVE-2022-24396",
"datePublished": "2022-03-08T13:35:46.000Z",
"dateReserved": "2022-02-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:07:02.528Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2474 (GCVE-0-2022-2474)
Vulnerability from cvelistv5 – Published: 2022-10-28 17:11 – Updated: 2025-04-16 16:07- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| Haas | Haas CNC Controller |
Affected:
Version 100.20.000.1110
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:39:07.548Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2474",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:53:12.202393Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:07:37.506Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Haas CNC Controller",
"vendor": "Haas",
"versions": [
{
"status": "affected",
"version": "Version 100.20.000.1110"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Marco Balduzzi of Trend Micro and Francesco Sortino from Celada Spa reported this vulnerability."
}
],
"datePublic": "2022-10-25T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Authentication is currently unsupported in Haas Controller version 100.20.000.1110 when using the \u201cEthernet Q Commands\u201d service, which allows any user on the same network segment as the controller (even while connected remotely) to access the service and write unauthorized macros to the device."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-10-28T00:00:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-298-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-2474",
"datePublished": "2022-10-28T17:11:30.593Z",
"dateReserved": "2022-07-19T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:07:37.506Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-24829 (GCVE-0-2022-24829)
Vulnerability from cvelistv5 – Published: 2022-04-11 19:45 – Updated: 2025-04-23 18:41- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://github.com/garden-io/garden/security/advi… | x_refsource_CONFIRM |
| https://github.com/garden-io/garden/commit/56051a… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:20:50.552Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://github.com/garden-io/garden/security/advisories/GHSA-f5f3-qrqw-2vqf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/garden-io/garden/commit/56051a5b50409227bc420910da88ed156a6e432b"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-24829",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T15:54:44.001752Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T18:41:07.064Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "garden",
"vendor": "garden-io",
"versions": [
{
"status": "affected",
"version": "\u003c 0.12.39"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Garden is an automation platform for Kubernetes development and testing. In versions prior to 0.12.39 multiple endpoints did not require authentication. In some operating modes this allows for an attacker to gain access to the application erroneously. The configuration is leaked through the /api endpoint on the local server that is responsible for serving the Garden dashboard. At the moment, this server is accessible to 0.0.0.0 which makes it accessible to anyone on the same network (or anyone on the internet if they are on a public, static IP). This may lead to the ability to compromise credentials, secrets or environment variables. Users are advised to upgrade to version 0.12.39 as soon as possible. Users unable to upgrade should use a firewall blocking access to port 9777 from all untrusted network machines."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-11T19:45:16.000Z",
"orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"shortName": "GitHub_M"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://github.com/garden-io/garden/security/advisories/GHSA-f5f3-qrqw-2vqf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/garden-io/garden/commit/56051a5b50409227bc420910da88ed156a6e432b"
}
],
"source": {
"advisory": "GHSA-f5f3-qrqw-2vqf",
"discovery": "UNKNOWN"
},
"title": "Missing authentication in Garden",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-advisories@github.com",
"ID": "CVE-2022-24829",
"STATE": "PUBLIC",
"TITLE": "Missing authentication in Garden"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "garden",
"version": {
"version_data": [
{
"version_value": "\u003c 0.12.39"
}
]
}
}
]
},
"vendor_name": "garden-io"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Garden is an automation platform for Kubernetes development and testing. In versions prior to 0.12.39 multiple endpoints did not require authentication. In some operating modes this allows for an attacker to gain access to the application erroneously. The configuration is leaked through the /api endpoint on the local server that is responsible for serving the Garden dashboard. At the moment, this server is accessible to 0.0.0.0 which makes it accessible to anyone on the same network (or anyone on the internet if they are on a public, static IP). This may lead to the ability to compromise credentials, secrets or environment variables. Users are advised to upgrade to version 0.12.39 as soon as possible. Users unable to upgrade should use a firewall blocking access to port 9777 from all untrusted network machines."
}
]
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306: Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://github.com/garden-io/garden/security/advisories/GHSA-f5f3-qrqw-2vqf",
"refsource": "CONFIRM",
"url": "https://github.com/garden-io/garden/security/advisories/GHSA-f5f3-qrqw-2vqf"
},
{
"name": "https://github.com/garden-io/garden/commit/56051a5b50409227bc420910da88ed156a6e432b",
"refsource": "MISC",
"url": "https://github.com/garden-io/garden/commit/56051a5b50409227bc420910da88ed156a6e432b"
}
]
},
"source": {
"advisory": "GHSA-f5f3-qrqw-2vqf",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
"assignerShortName": "GitHub_M",
"cveId": "CVE-2022-24829",
"datePublished": "2022-04-11T19:45:16.000Z",
"dateReserved": "2022-02-10T00:00:00.000Z",
"dateUpdated": "2025-04-23T18:41:07.064Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25247 (GCVE-0-2022-25247)
Vulnerability from cvelistv5 – Published: 2022-03-16 14:03 – Updated: 2025-04-16 16:43- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_MISC |
| https://www.ptc.com/en/support/article/CS363561 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Axeda agent |
Affected:
All Versions
|
|
| PTC | Axeda Desktop Server for Windows |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:36:06.600Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/CS363561"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25247",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:58:00.627996Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:43:03.219Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Axeda agent",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "Axeda Desktop Server for Windows",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Yuval Shoshani and Elad Luz of CyberMDX and Vedere Labs reported these vulnerabilities to PTC"
}
],
"datePublic": "2022-03-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-16T14:03:29.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ptc.com/en/support/article/CS363561"
}
],
"solutions": [
{
"lang": "en",
"value": "PTC recommends the following:\n\nUpgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent.\nConfigure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255\nProvide a unique password in the AxedaDesktop.ini file for each unit.\nNever use ERemoteServer in production.\nMake sure to delete ERemoteServer file from host device.\nRemove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi\nWhen running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others.\nWhen running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255\nConfigure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255\nPTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215\n\nThe Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required."
}
],
"source": {
"advisory": "ICSA-22-067-01",
"discovery": "UNKNOWN"
},
"title": "PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-08T17:50:00.000Z",
"ID": "CVE-2022-25247",
"STATE": "PUBLIC",
"TITLE": "PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Axeda agent",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "Axeda Desktop Server for Windows",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "PTC"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Yuval Shoshani and Elad Luz of CyberMDX and Vedere Labs reported these vulnerabilities to PTC"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain commands to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to obtain full file-system access and remote code execution."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"name": "https://www.ptc.com/en/support/article/CS363561",
"refsource": "MISC",
"url": "https://www.ptc.com/en/support/article/CS363561"
}
]
},
"solution": [
{
"lang": "en",
"value": "PTC recommends the following:\n\nUpgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent.\nConfigure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255\nProvide a unique password in the AxedaDesktop.ini file for each unit.\nNever use ERemoteServer in production.\nMake sure to delete ERemoteServer file from host device.\nRemove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi\nWhen running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others.\nWhen running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255\nConfigure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255\nPTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215\n\nThe Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required."
}
],
"source": {
"advisory": "ICSA-22-067-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-25247",
"datePublished": "2022-03-16T14:03:29.947Z",
"dateReserved": "2022-02-16T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:43:03.219Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25250 (GCVE-0-2022-25250)
Vulnerability from cvelistv5 – Published: 2022-03-16 14:03 – Updated: 2025-04-16 16:42- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_MISC |
| https://www.ptc.com/en/support/article/CS363561 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Axeda agent |
Affected:
All Versions
|
|
| PTC | Axeda Desktop Server for Windows |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:36:06.612Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/CS363561"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25250",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:59:25.534488Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:42:25.954Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Axeda agent",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "Axeda Desktop Server for Windows",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Yuval Shoshani and Elad Luz of CyberMDX and Vedere Labs reported these vulnerabilities to PTC"
}
],
"datePublic": "2022-03-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-16T14:03:34.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ptc.com/en/support/article/CS363561"
}
],
"solutions": [
{
"lang": "en",
"value": "PTC recommends the following:\n\nUpgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent.\nConfigure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255\nProvide a unique password in the AxedaDesktop.ini file for each unit.\nNever use ERemoteServer in production.\nMake sure to delete ERemoteServer file from host device.\nRemove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi\nWhen running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others.\nWhen running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255\nConfigure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255\nPTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215\n\nThe Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required."
}
],
"source": {
"advisory": "ICSA-22-067-01",
"discovery": "UNKNOWN"
},
"title": "PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-08T17:50:00.000Z",
"ID": "CVE-2022-25250",
"STATE": "PUBLIC",
"TITLE": "PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Axeda agent",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "Axeda Desktop Server for Windows",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "PTC"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Yuval Shoshani and Elad Luz of CyberMDX and Vedere Labs reported these vulnerabilities to PTC"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send a certain command to a specific port without authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to shut down a specific service."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"name": "https://www.ptc.com/en/support/article/CS363561",
"refsource": "MISC",
"url": "https://www.ptc.com/en/support/article/CS363561"
}
]
},
"solution": [
{
"lang": "en",
"value": "PTC recommends the following:\n\nUpgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent.\nConfigure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255\nProvide a unique password in the AxedaDesktop.ini file for each unit.\nNever use ERemoteServer in production.\nMake sure to delete ERemoteServer file from host device.\nRemove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi\nWhen running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others.\nWhen running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255\nConfigure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255\nPTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215\n\nThe Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required."
}
],
"source": {
"advisory": "ICSA-22-067-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-25250",
"datePublished": "2022-03-16T14:03:34.493Z",
"dateReserved": "2022-02-16T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:42:25.954Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25251 (GCVE-0-2022-25251)
Vulnerability from cvelistv5 – Published: 2022-03-16 14:03 – Updated: 2025-04-16 16:42- CWE-306 - Missing Authentication for Critical Function
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_MISC |
| https://www.ptc.com/en/support/article/CS363561 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| PTC | Axeda agent |
Affected:
All Versions
|
|
| PTC | Axeda Desktop Server for Windows |
Affected:
All Versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:36:06.557Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.ptc.com/en/support/article/CS363561"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25251",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:57:53.119800Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:42:06.086Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Axeda agent",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
},
{
"product": "Axeda Desktop Server for Windows",
"vendor": "PTC",
"versions": [
{
"status": "affected",
"version": "All Versions"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Yuval Shoshani and Elad Luz of CyberMDX and Vedere Labs reported these vulnerabilities to PTC"
}
],
"datePublic": "2022-03-08T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product\u2019s configuration."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-16T14:03:36.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.ptc.com/en/support/article/CS363561"
}
],
"solutions": [
{
"lang": "en",
"value": "PTC recommends the following:\n\nUpgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent.\nConfigure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255\nProvide a unique password in the AxedaDesktop.ini file for each unit.\nNever use ERemoteServer in production.\nMake sure to delete ERemoteServer file from host device.\nRemove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi\nWhen running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others.\nWhen running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255\nConfigure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255\nPTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215\n\nThe Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required."
}
],
"source": {
"advisory": "ICSA-22-067-01",
"discovery": "UNKNOWN"
},
"title": "PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"DATE_PUBLIC": "2022-03-08T17:50:00.000Z",
"ID": "CVE-2022-25251",
"STATE": "PUBLIC",
"TITLE": "PTC Axeda agent and Axeda Desktop Server Missing Authentication For Critical Function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Axeda agent",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
},
{
"product_name": "Axeda Desktop Server for Windows",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All Versions"
}
]
}
}
]
},
"vendor_name": "PTC"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Yuval Shoshani and Elad Luz of CyberMDX and Vedere Labs reported these vulnerabilities to PTC"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "When connecting to a certain port Axeda agent (All versions) and Axeda Desktop Server for Windows (All versions) may allow an attacker to send certain XML messages to a specific port without proper authentication. Successful exploitation of this vulnerability could allow a remote unauthenticated attacker to read and modify the affected product\u2019s configuration."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306 Missing Authentication for Critical Function"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01",
"refsource": "MISC",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-067-01"
},
{
"name": "https://www.ptc.com/en/support/article/CS363561",
"refsource": "MISC",
"url": "https://www.ptc.com/en/support/article/CS363561"
}
]
},
"solution": [
{
"lang": "en",
"value": "PTC recommends the following:\n\nUpgrade to Axeda agent Version 6.9.2 build 1049 or 6.9.3 build 1051 when running older versions of the Axeda agent.\nConfigure Axeda agent and Axeda Desktop Server (ADS) to only listen on the local host interface 127.0.0.1. Refer to PTC knowledge article CS360255\nProvide a unique password in the AxedaDesktop.ini file for each unit.\nNever use ERemoteServer in production.\nMake sure to delete ERemoteServer file from host device.\nRemove the installation file, for example: Gateway_vs2017-en-us-x64-pc-winnt-vc14-6.9.3-1051.msi\nWhen running in Windows or Linux, only allow connections to ERemoteServer from trusted hosts and block all others.\nWhen running the Windows operating system, configure Localhost communications (127.0.0.1) between ERemoteServer and Axeda Builder. Refer to PTC knowledge article CS360255\nConfigure the Axeda agent for the authentication information required to log in to the Axeda Deployment Utility. Refer to PTC knowledge article CS360255\nPTC recommends upgrading the Axeda Desktop Server (ADS) to Version 6.9 build 215\n\nThe Axeda agent loopback-only configuration is only available in Version 6.9.1 and above. Hence, upgrading to Axeda agent 6.9.1 or above is required."
}
],
"source": {
"advisory": "ICSA-22-067-01",
"discovery": "UNKNOWN"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-25251",
"datePublished": "2022-03-16T14:03:36.591Z",
"dateReserved": "2022-02-16T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:42:06.086Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25770 (GCVE-0-2022-25770)
Vulnerability from cvelistv5 – Published: 2024-09-18 21:26 – Updated: 2024-09-19 14:47- CWE-306 - Missing Authentication for Critical Function
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25770",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-19T14:47:02.190322Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-19T14:47:14.786Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://packagist.org",
"defaultStatus": "unaffected",
"packageName": "mautic/core-lib",
"product": "Mautic",
"repo": "https://github.com/mautic/mautic",
"vendor": "Mautic",
"versions": [
{
"lessThan": "\u003c 4.4.13",
"status": "affected",
"version": "\u003e= 1.0.0-beta3",
"versionType": "semver"
},
{
"lessThan": "\u003c 5.1.1.",
"status": "affected",
"version": "\u003e= 5.0.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Mattias Michaux"
},
{
"lang": "en",
"type": "remediation reviewer",
"value": "Zdeno Kuzmany"
},
{
"lang": "en",
"type": "remediation developer",
"value": "Mattias Michaux"
},
{
"lang": "en",
"type": "remediation reviewer",
"value": "John Linhart"
},
{
"lang": "en",
"type": "remediation reviewer",
"value": "Patryk Gruszka"
}
],
"datePublic": "2024-09-18T20:41:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Mautic allows you to update the application via an upgrade script.\u003cbr\u003e\u003cbr\u003eThe upgrade logic isn\u0027t shielded off correctly, which may lead to vulnerable situation.\u003cbr\u003e\u003cbr\u003eThis vulnerability is mitigated by the fact that Mautic needs to be installed in a certain way to be vulnerable.\u003cbr\u003e"
}
],
"value": "Mautic allows you to update the application via an upgrade script.\n\nThe upgrade logic isn\u0027t shielded off correctly, which may lead to vulnerable situation.\n\nThis vulnerability is mitigated by the fact that Mautic needs to be installed in a certain way to be vulnerable."
}
],
"impacts": [
{
"capecId": "CAPEC-115",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-115 Authentication Bypass"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:N/UI:N/S:C/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306 Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-09-18T21:26:34.059Z",
"orgId": "4e531c38-7a33-45d3-98dd-d909c0d8852e",
"shortName": "Mautic"
},
"references": [
{
"url": "https://github.com/mautic/mautic/security/advisories/GHSA-qf6m-6m4g-rmrc"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Upgrade to 4.4.13 or 5.1.1 or higher."
}
],
"value": "Upgrade to 4.4.13 or 5.1.1 or higher."
}
],
"source": {
"advisory": "GHSA-qf6m-6m4g-rmrc",
"discovery": "INTERNAL"
},
"title": "Insufficient authentication in upgrade flow",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4e531c38-7a33-45d3-98dd-d909c0d8852e",
"assignerShortName": "Mautic",
"cveId": "CVE-2022-25770",
"datePublished": "2024-09-18T21:26:34.059Z",
"dateReserved": "2022-02-22T20:17:36.804Z",
"dateUpdated": "2024-09-19T14:47:14.786Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25922 (GCVE-0-2022-25922)
Vulnerability from cvelistv5 – Published: 2022-03-07 15:28 – Updated: 2025-04-16 16:43| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Power Line Communications | PLC4TRUCKS |
Affected:
J2497
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:44.366Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-063-01"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-25922",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:56:06.000143Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:43:59.855Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "PLC4TRUCKS",
"vendor": "Power Line Communications",
"versions": [
{
"status": "affected",
"version": "J2497 "
}
]
}
],
"credits": [
{
"lang": "en",
"value": "National Motor Freight Traffic Association, Inc. (NMFTA) researcher Ben Gardiner, NMFTA motor freight carrier members, and Assured Information Security researchers Chris Poore, Dan Salloum, and Eric Thayer reported this vulnerability to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-07T15:28:22.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-063-01"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "ICSA-22-063-01 Missing Authentication for Critical Function in Trailer Power Line Communications (PLC) J2497",
"workarounds": [
{
"lang": "en",
"value": "The vulnerable technology, J2497, has been fielded since 2001 and the service lifetime of trailers is 15 to 30 years. For new equipment, the industry should consider dropping all J2497 features except for backwards-compatibility with LAMP ON detection only. For trailer equipment this means migrating all diagnostics to whatever newer trailer buses are established as the norm. For tractor equipment this means removing support for reception of any J2497 message other than LAMP messages and protecting the backwards-compatible trailers from attack. \n\nNMFTA has published detailed information about how to mitigate these issues in the following ways:\nInstall a LAMP ON firewall for each ECU\nUse a LAMP detect circuit LAMP ON sender with each trailer\nChange addresses dynamically on each tractor in response to detecting a transmitter on its current address. \nInstall RF chokes on each trailer between chassis ground and wiring ground\nLoad with LAMP keyhole signal on each tractor\nFlood with jamming signal on each tractor\nPlease see the publication from the NMFTA for additional details on these and other solutions."
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2022-25922",
"STATE": "PUBLIC",
"TITLE": "ICSA-22-063-01 Missing Authentication for Critical Function in Trailer Power Line Communications (PLC) J2497"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PLC4TRUCKS",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "J2497 "
}
]
}
}
]
},
"vendor_name": "Power Line Communications"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "National Motor Freight Traffic Association, Inc. (NMFTA) researcher Ben Gardiner, NMFTA motor freight carrier members, and Assured Information Security researchers Chris Poore, Dan Salloum, and Eric Thayer reported this vulnerability to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Power Line Communications PLC4TRUCKS J2497 trailer brake controllers implement diagnostic functions which can be invoked by replaying J2497 messages. There is no authentication or authorization for these functions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-306"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-063-01",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-063-01"
}
]
},
"source": {
"discovery": "UNKNOWN"
},
"work_around": [
{
"lang": "en",
"value": "The vulnerable technology, J2497, has been fielded since 2001 and the service lifetime of trailers is 15 to 30 years. For new equipment, the industry should consider dropping all J2497 features except for backwards-compatibility with LAMP ON detection only. For trailer equipment this means migrating all diagnostics to whatever newer trailer buses are established as the norm. For tractor equipment this means removing support for reception of any J2497 message other than LAMP messages and protecting the backwards-compatible trailers from attack. \n\nNMFTA has published detailed information about how to mitigate these issues in the following ways:\nInstall a LAMP ON firewall for each ECU\nUse a LAMP detect circuit LAMP ON sender with each trailer\nChange addresses dynamically on each tractor in response to detecting a transmitter on its current address. \nInstall RF chokes on each trailer between chassis ground and wiring ground\nLoad with LAMP keyhole signal on each tractor\nFlood with jamming signal on each tractor\nPlease see the publication from the NMFTA for additional details on these and other solutions."
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2022-25922",
"datePublished": "2022-03-07T15:28:22.000Z",
"dateReserved": "2022-03-01T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:43:59.855Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-26026 (GCVE-0-2022-26026)
Vulnerability from cvelistv5 – Published: 2022-05-25 20:15 – Updated: 2025-04-15 19:01- CWE-306 - Missing Authentication for Critical Function
| Vendor | Product | Version | |
|---|---|---|---|
| Open Automation Software | OAS Platform |
Affected:
V16.00.0112
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:56:37.171Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1491",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1491"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-26026",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-15T18:19:06.579253Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-15T19:01:28.799Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "OAS Platform",
"vendor": "Open Automation Software",
"versions": [
{
"status": "affected",
"version": "V16.00.0112"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Discovered by Jared Rittle of Cisco Talos."
}
],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in the OAS Engine SecureConfigValues functionality of Open Automation Software OAS Platform V16.00.0112. A specially-crafted network request can lead to loss of communications. An attacker can send a network request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-07-26T17:34:38.391Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1491",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1491"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-26026",
"datePublished": "2022-05-25T20:15:19.304Z",
"dateReserved": "2022-03-14T00:00:00.000Z",
"dateUpdated": "2025-04-15T19:01:28.799Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Architecture and Design
Description:
- Divide the software into anonymous, normal, privileged, and administrative areas. Identify which of these areas require a proven user identity, and use a centralized authentication capability.
- Identify all potential communication channels, or other means of interaction with the software, to ensure that all channels are appropriately protected, including those channels that are assumed to be accessible only by authorized parties. Developers sometimes perform authentication at the primary channel, but open up a secondary channel that is assumed to be private. For example, a login mechanism may be listening on one network port, but after successful authentication, it may open up a second port where it waits for the connection, but avoids authentication because it assumes that only the authenticated party will connect to the port.
- In general, if the software or protocol allows a single session or user state to persist across multiple connections or channels, authentication and appropriate credential management need to be used throughout.
Mitigation ID: MIT-15
Phase: Architecture and Design
Description:
- For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
Mitigation
Phase: Architecture and Design
Description:
- Where possible, avoid implementing custom, "grow-your-own" authentication routines and consider using authentication capabilities as provided by the surrounding framework, operating system, or environment. These capabilities may avoid common weaknesses that are unique to authentication; support automatic auditing and tracking; and make it easier to provide a clear separation between authentication tasks and authorization tasks.
- In environments such as the World Wide Web, the line between authentication and authorization is sometimes blurred. If custom authentication routines are required instead of those provided by the server, then these routines must be applied to every single page, since these pages could be requested directly.
Mitigation ID: MIT-4.5
Phase: Architecture and Design
Strategy: Libraries or Frameworks
Description:
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
- For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator [REF-45].
Mitigation
Phases: Implementation, System Configuration, Operation
Description:
- When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data [REF-1297] [REF-1298] [REF-1302].
CAPEC-12: Choosing Message Identifier
This pattern of attack is defined by the selection of messages distributed via multicast or public information channels that are intended for another client by determining the parameter value assigned to that client. This attack allows the adversary to gain access to potentially privileged information, and to possibly perpetrate other attacks through the distribution means by impersonation. If the channel/message being manipulated is an input rather than output mechanism for the system, (such as a command bus), this style of attack could be used to change the adversary's identifier to more a privileged one.
CAPEC-166: Force the System to Reset Values
An attacker forces the target into a previous state in order to leverage potential weaknesses in the target dependent upon a prior configuration or state-dependent factors. Even in cases where an attacker may not be able to directly control the configuration of the targeted application, they may be able to reset the configuration to a prior state since many applications implement reset functions.
CAPEC-216: Communication Channel Manipulation
An adversary manipulates a setting or parameter on communications channel in order to compromise its security. This can result in information exposure, insertion/removal of information from the communications stream, and/or potentially system compromise.
CAPEC-36: Using Unpublished Interfaces or Functionality
An adversary searches for and invokes interfaces or functionality that the target system designers did not intend to be publicly available. If interfaces fail to authenticate requests, the attacker may be able to invoke functionality they are not authorized for.
CAPEC-62: Cross Site Request Forgery
An attacker crafts malicious web links and distributes them (via web pages, email, etc.), typically in a targeted manner, hoping to induce users to click on the link and execute the malicious action against some third-party application. If successful, the action embedded in the malicious link will be processed and accepted by the targeted application with the users' privilege level. This type of attack leverages the persistence and implicit trust placed in user session cookies by many web applications today. In such an architecture, once the user authenticates to an application and a session cookie is created on the user's system, all following transactions for that session are authenticated using that cookie including potential actions initiated by an attacker and simply "riding" the existing session cookie.