CWE-306

Missing Authentication for Critical Function

The product does not perform any authentication for functionality that requires a provable user identity or consumes a significant amount of resources.

CVE-2020-37157 (GCVE-0-2020-37157)

Vulnerability from cvelistv5 – Published: 2026-02-06 23:14 – Updated: 2026-02-17 16:57
VLAI
Title
DBPower C300 HD Camera - Remote Configuration Disclosure
Summary
DBPower C300 HD Camera contains a configuration disclosure vulnerability that allows unauthenticated attackers to retrieve sensitive credentials through an unprotected configuration backup endpoint. Attackers can download the configuration file and extract hardcoded username and password by accessing the /tmpfs/config_backup.bin resource.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
Impacted products
Date Public
2020-02-19 00:00
Credits
Todor Donev
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-37157",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-17T16:57:23.915426Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-17T16:57:33.305Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DBPower C300 HD Camera",
          "vendor": "DBPower",
          "versions": [
            {
              "status": "affected",
              "version": "-"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Todor Donev"
        }
      ],
      "datePublic": "2020-02-19T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "DBPower C300 HD Camera contains a configuration disclosure vulnerability that allows unauthenticated attackers to retrieve sensitive credentials through an unprotected configuration backup endpoint. Attackers can download the configuration file and extract hardcoded username and password by accessing the /tmpfs/config_backup.bin resource."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS"
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-06T23:14:09.598Z",
        "orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
        "shortName": "VulnCheck"
      },
      "references": [
        {
          "name": "ExploitDB-48095",
          "tags": [
            "exploit"
          ],
          "url": "https://www.exploit-db.com/exploits/48095"
        },
        {
          "name": "Archived Researcher Blog",
          "tags": [
            "technical-description",
            "exploit"
          ],
          "url": "https://web.archive.org/web/20200620110617/https://donev.eu/blog/dbpower-c300-multiple-vulnerabilities"
        },
        {
          "name": "VulnCheck Advisory: DBPower C300 HD Camera - Remote Configuration Disclosure",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://www.vulncheck.com/advisories/dbpower-c-hd-camera-remote-configuration-disclosure"
        }
      ],
      "title": "DBPower C300 HD Camera - Remote Configuration Disclosure",
      "x_generator": {
        "engine": "vulncheck"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
    "assignerShortName": "VulnCheck",
    "cveId": "CVE-2020-37157",
    "datePublished": "2026-02-06T23:14:09.598Z",
    "dateReserved": "2026-02-03T16:27:45.310Z",
    "dateUpdated": "2026-02-17T16:57:33.305Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2020-5326 (GCVE-0-2020-5326)

Vulnerability from cvelistv5 – Published: 2020-02-21 14:50 – Updated: 2024-09-17 01:56
VLAI
Summary
Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Dell Dell Client Consumer and Commercial Platforms Affected: https://www.dell.com/support/article/SLN320337
Create a notification for this product.
Date Public
2020-02-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:09.254Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/article/SLN320337"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Dell Client Consumer and Commercial Platforms",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "https://www.dell.com/support/article/SLN320337"
            }
          ]
        }
      ],
      "datePublic": "2020-02-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "PHYSICAL",
            "availabilityImpact": "HIGH",
            "baseScore": 6.1,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-21T14:50:14.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/article/SLN320337"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-02-18",
          "ID": "CVE-2020-5326",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Dell Client Consumer and Commercial Platforms",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "https://www.dell.com/support/article/SLN320337"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Affected Dell Client platforms contain a BIOS Setup configuration authentication bypass vulnerability in the pre-boot Intel Rapid Storage Response Technology (iRST) Manager menu. An attacker with physical access to the system could perform unauthorized changes to the BIOS Setup configuration settings without requiring the BIOS Admin password by selecting the Optimized Defaults option in the pre-boot iRST Manager."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.1,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:L/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/article/SLN320337",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/article/SLN320337"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5326",
    "datePublished": "2020-02-21T14:50:14.182Z",
    "dateReserved": "2020-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-17T01:56:45.382Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5328 (GCVE-0-2020-5328)

Vulnerability from cvelistv5 – Published: 2020-03-06 20:25 – Updated: 2024-09-16 18:29
VLAI
Summary
Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Dell Isilon OneFS Affected: unspecified , < 8.2.0 (custom)
Create a notification for this product.
Date Public
2020-02-20 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:22:09.299Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Isilon OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.2.0",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-02-20T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-03-06T20:25:14.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-02-20",
          "ID": "CVE-2020-5328",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Isilon OneFS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.2.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC Isilon OneFS versions prior to 8.2.0 contain an unauthorized access vulnerability due to a lack of thorough authorization checks when SyncIQ is licensed, but encrypted syncs are not marked as required. When this happens, loss of control of the cluster can occur."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 9.8,
            "baseSeverity": "Critical",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/security/en-us/details/541423/DSA-2020-039-Dell-EMC-Isilon-OneFS-Security-Update-for-a-SyncIQ-Vulnerability"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5328",
    "datePublished": "2020-03-06T20:25:14.219Z",
    "dateReserved": "2020-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-16T18:29:46.134Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5373 (GCVE-0-2020-5373)

Vulnerability from cvelistv5 – Published: 2020-07-14 19:30 – Updated: 2024-09-17 03:02
VLAI
Summary
Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to retrieve the system inventory data of the managed device.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Date Public
2020-07-13 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:23.429Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OMIMSSC (OpenManage Integration for Microsoft System Center)",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "7.2.1",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2020-07-13T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to retrieve the system inventory data of the managed device."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-14T19:30:14.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2020-07-13",
          "ID": "CVE-2020-5373",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OMIMSSC (OpenManage Integration for Microsoft System Center)",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "7.2.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Dell EMC OpenManage Integration for Microsoft System Center (OMIMSSC) for SCCM and SCVMM versions prior to 7.2.1 contain an improper authentication vulnerability. A remote unauthenticated attacker may potentially exploit this vulnerability to retrieve the system inventory data of the managed device."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 6.5,
            "baseSeverity": "Medium",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/article/en-us/sln322169/dsa-2020-163-dell-emc-openmanage-integration-for-microsoft-system-center-multiple-vulnerabilities?lang=en"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2020-5373",
    "datePublished": "2020-07-14T19:30:14.797Z",
    "dateReserved": "2020-01-03T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:02:58.871Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-5589 (GCVE-0-2020-5589)

Vulnerability from cvelistv5 – Published: 2020-06-09 08:00 – Updated: 2024-08-04 08:30
VLAI
Summary
SONY Wireless Headphones WF-1000X, WF-SP700N, WH-1000XM2, WH-1000XM3, WH-CH700N, WH-H900N, WH-XB700, WH-XB900N, WI-1000X, WI-C600N and WI-SP600N with firmware versions prior to 4.5.2 have vulnerability that someone within the Bluetooth range can make the Bluetooth pairing and operate such as changing volume of the product.
Severity
No CVSS data available.
CWE
  • CWE-306 - missing authentication for critical function
Assigner
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T08:30:24.643Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.sony.com/electronics/support/audio-video-headphones"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://jvn.jp/en/jp/JVN67447798/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Sony wireless headphones WF-1000X, WF-SP700N, WH-1000XM2, WH-1000XM3, WH-CH700N, WH-H900N, WH-XB700, WH-XB900N, WI-1000X, WI-C600N, WI-SP600N",
          "vendor": "Sony Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "firmware versions prior to 4.5.2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "SONY Wireless Headphones WF-1000X, WF-SP700N, WH-1000XM2, WH-1000XM3, WH-CH700N, WH-H900N, WH-XB700, WH-XB900N, WI-1000X, WI-C600N and WI-SP600N with firmware versions prior to 4.5.2 have vulnerability that someone within the Bluetooth range can make the Bluetooth pairing and operate such as changing volume of the product."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: missing authentication for critical function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-06-23T17:36:57.000Z",
        "orgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
        "shortName": "jpcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.sony.com/electronics/support/audio-video-headphones"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://jvn.jp/en/jp/JVN67447798/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vultures@jpcert.or.jp",
          "ID": "CVE-2020-5589",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Sony wireless headphones WF-1000X, WF-SP700N, WH-1000XM2, WH-1000XM3, WH-CH700N, WH-H900N, WH-XB700, WH-XB900N, WI-1000X, WI-C600N, WI-SP600N",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "firmware versions prior to 4.5.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Sony Corporation"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "SONY Wireless Headphones WF-1000X, WF-SP700N, WH-1000XM2, WH-1000XM3, WH-CH700N, WH-H900N, WH-XB700, WH-XB900N, WI-1000X, WI-C600N and WI-SP600N with firmware versions prior to 4.5.2 have vulnerability that someone within the Bluetooth range can make the Bluetooth pairing and operate such as changing volume of the product."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: missing authentication for critical function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.sony.com/electronics/support/audio-video-headphones",
              "refsource": "MISC",
              "url": "https://www.sony.com/electronics/support/audio-video-headphones"
            },
            {
              "name": "https://jvn.jp/en/jp/JVN67447798/",
              "refsource": "MISC",
              "url": "https://jvn.jp/en/jp/JVN67447798/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ede6fdc4-6654-4307-a26d-3331c018e2ce",
    "assignerShortName": "jpcert",
    "cveId": "CVE-2020-5589",
    "datePublished": "2020-06-09T08:00:17.000Z",
    "dateReserved": "2020-01-06T00:00:00.000Z",
    "dateUpdated": "2024-08-04T08:30:24.643Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6769 (GCVE-0-2020-6769)

Vulnerability from cvelistv5 – Published: 2020-02-07 19:57 – Updated: 2024-09-16 21:03
VLAI
Title
Missing Authentication for Critical Function in Bosch Video Streaming Gateway
Summary
Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 <= 6.45.08, 6.44 <= 6.44.022, 6.43 <= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 <= 3.62.0019 and DIVAR IP 5000 <= 3.80.0039 if the corresponding port 8023 has been opened in the device's firewall.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Bosch DIVAR IP 2000 Affected: unspecified , ≤ 3.62.0019 (custom)
Create a notification for this product.
Bosch DIVAR IP 5000 Affected: unspecified , ≤ 3.80.0039 (custom)
Create a notification for this product.
Bosch Video Streaming Gateway Affected: 6.45 , ≤ 6.45.08 (custom)
Affected: 6.44 , ≤ 6.44.0030 (custom)
Affected: 6.43 , ≤ 6.43.0023 (custom)
Affected: 6.42 and older , ≤ 6.42.10 (custom)
Create a notification for this product.
Bosch DIVAR IP 3000 Affected: All
Create a notification for this product.
Bosch DIVAR IP 7000 Affected: All
Create a notification for this product.
Bosch DIVAR IP all-in-one 5000 Affected: All
Create a notification for this product.
Date Public
2020-01-29 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:11:04.658Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "DIVAR IP 2000",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.62.0019",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "DIVAR IP 5000",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "3.80.0039",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "Video Streaming Gateway",
          "vendor": "Bosch",
          "versions": [
            {
              "lessThanOrEqual": "6.45.08",
              "status": "affected",
              "version": "6.45",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "6.44.0030",
              "status": "affected",
              "version": "6.44",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "6.43.0023",
              "status": "affected",
              "version": "6.43",
              "versionType": "custom"
            },
            {
              "lessThanOrEqual": "6.42.10",
              "status": "affected",
              "version": "6.42 and older",
              "versionType": "custom"
            }
          ]
        },
        {
          "product": "DIVAR IP 3000",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "DIVAR IP 7000",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        },
        {
          "product": "DIVAR IP all-in-one 5000",
          "vendor": "Bosch",
          "versions": [
            {
              "status": "affected",
              "version": "All"
            }
          ]
        }
      ],
      "datePublic": "2020-01-29T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-07T19:57:12.000Z",
        "orgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
        "shortName": "bosch"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
        }
      ],
      "source": {
        "advisory": "BOSCH-SA-260625-BT",
        "discovery": "INTERNAL"
      },
      "title": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "psirt@bosch.com",
          "DATE_PUBLIC": "2020-01-29T13:00:00.000Z",
          "ID": "CVE-2020-6769",
          "STATE": "PUBLIC",
          "TITLE": "Missing Authentication for Critical Function in Bosch Video Streaming Gateway"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "DIVAR IP 2000",
                      "version": {
                        "version_data": [
                          {
                            "configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed",
                            "version_affected": "\u003c=",
                            "version_value": "3.62.0019"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "DIVAR IP 5000",
                      "version": {
                        "version_data": [
                          {
                            "configuration": "port 8023 on device\u0027s firewall opened explicitly and vulnerable VSG version installed",
                            "version_affected": "\u003c=",
                            "version_value": "3.80.0039"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "Video Streaming Gateway",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.45",
                            "version_value": "6.45.08"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.44",
                            "version_value": "6.44.0030"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.43",
                            "version_value": "6.43.0023"
                          },
                          {
                            "version_affected": "\u003c=",
                            "version_name": "6.42 and older",
                            "version_value": "6.42.10"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "DIVAR IP 3000",
                      "version": {
                        "version_data": [
                          {
                            "configuration": "vulnerable VSG version installed",
                            "version_affected": "=",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "DIVAR IP 7000",
                      "version": {
                        "version_data": [
                          {
                            "configuration": "vulnerable VSG version installed",
                            "version_affected": "=",
                            "version_value": "All"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "DIVAR IP all-in-one 5000",
                      "version": {
                        "version_data": [
                          {
                            "configuration": "vulnerable VSG version installed",
                            "version_affected": "=",
                            "version_value": "All"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Bosch"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Missing Authentication for Critical Function in the Bosch Video Streaming Gateway (VSG) allows an unauthenticated remote attacker to retrieve and set arbitrary configuration data of the Video Streaming Gateway. A successful attack can impact the confidentiality and availability of live and recorded video data of all cameras configured to be controlled by the VSG as well as the recording storage associated with the VSG. This affects Bosch Video Streaming Gateway versions 6.45 \u003c= 6.45.08, 6.44 \u003c= 6.44.022, 6.43 \u003c= 6.43.0023 and 6.42.10 and older. This affects Bosch DIVAR IP 3000, DIVAR IP 7000 and DIVAR IP all-in-one 5000 if a vulnerable VSG version is installed with BVMS. This affects Bosch DIVAR IP 2000 \u003c= 3.62.0019 and DIVAR IP 5000 \u003c= 3.80.0039 if the corresponding port 8023 has been opened in the device\u0027s firewall."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306 Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html",
              "refsource": "CONFIRM",
              "url": "https://psirt.bosch.com/security-advisories/BOSCH-SA-260625-BT.html"
            }
          ]
        },
        "source": {
          "advisory": "BOSCH-SA-260625-BT",
          "discovery": "INTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c95f66b2-7e7c-41c5-8f09-6f86ec68659c",
    "assignerShortName": "bosch",
    "cveId": "CVE-2020-6769",
    "datePublished": "2020-02-07T19:57:12.914Z",
    "dateReserved": "2020-01-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T21:03:26.539Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6964 (GCVE-0-2020-6964)

Vulnerability from cvelistv5 – Published: 2020-01-24 16:32 – Updated: 2024-08-04 09:18
VLAI
Summary
In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 & prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network.
Severity
No CVSS data available.
CWE
  • CWE-306 - MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306
Assigner
References
Impacted products
Vendor Product Version
n/a GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors Affected: ApexPro Telemetry Server,v4.2 & prior,CARESCAPE Telemetry Server, v4.2 & prior,Clinical Information Center,v4.X& 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:02.496Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-01-24T16:32:13.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6964",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE CARESCAPE Telemetry Server,ApexPro Telemetry Server,CARESCAPE Central Station,Clinical Information Center systems,CARESCAPE B450,B650,B850 Monitors",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "ApexPro Telemetry Server,v4.2 \u0026 prior,CARESCAPE Telemetry Server, v4.2 \u0026 prior,Clinical Information Center,v4.X\u0026 5.X,CARESCAPE Telemetry Server,v4.3,CARESCAPE Central Station,v1.X,CARESCAPE Central Station,v2.X,B450,v2.X,B650,v1.X,B650,v2.X,B850,v1.X,B850,v2.X"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In ApexPro Telemetry Server Versions 4.2 and prior, CARESCAPE Telemetry Server v4.2 \u0026 prior, Clinical Information Center (CIC) Versions 4.X and 5.X, CARESCAPE Central Station (CSCS) Versions 1.X and CARESCAPE Central Station (CSCS) Versions 2.X, the integrated service for keyboard switching of the affected devices could allow attackers to obtain remote keyboard input access without authentication over the network."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "MISSING AUTHENTICATION FOR CRITICAL FUNCTION CWE-306"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-023-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6964",
    "datePublished": "2020-01-24T16:32:13.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:02.496Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7389 (GCVE-0-2020-7389)

Vulnerability from cvelistv5 – Published: 2021-07-22 18:27 – Updated: 2024-09-16 16:53
VLAI
Title
Sage X3 Syracuse Missing Authentication for Critical Function in Developer Environment
Summary
Sage X3 System CHAINE Variable Script Command Injection. An authenticated user with developer access can pass OS commands via this variable used by the web application. Note, this developer configuration should not be deployed in production.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
Sage X3 Affected: V9 , < Syracuse 9.22.7.2 (custom)
Affected: V11 , < Syracuse 11.25.2.6 (custom)
Affected: V12 , < Syracuse 12.10.2.8 (custom)
Create a notification for this product.
Date Public
2021-07-07 00:00
Credits
Jonathan Peterson, Aaron Herndon, Cale Black, Ryan Villarrea, and William Vu, all of Rapid7
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:25:49.087Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://rapid7.com/blog/post/2021/07/07/sage-x3-multiple-vulnerabilities-fixed"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "X3",
          "vendor": "Sage",
          "versions": [
            {
              "lessThan": "Syracuse 9.22.7.2",
              "status": "affected",
              "version": "V9",
              "versionType": "custom"
            },
            {
              "lessThan": "Syracuse 11.25.2.6",
              "status": "affected",
              "version": "V11",
              "versionType": "custom"
            },
            {
              "lessThan": "Syracuse 12.10.2.8",
              "status": "affected",
              "version": "V12",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Jonathan Peterson, Aaron Herndon, Cale Black, Ryan Villarrea, and William Vu, all of Rapid7"
        }
      ],
      "datePublic": "2021-07-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Sage X3 System CHAINE Variable Script Command Injection. An authenticated user with developer access can pass OS commands via this variable used by the web application. Note, this developer configuration should not be deployed in production."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-22T18:27:15.000Z",
        "orgId": "9974b330-7714-4307-a722-5648477acda7",
        "shortName": "rapid7"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://rapid7.com/blog/post/2021/07/07/sage-x3-multiple-vulnerabilities-fixed"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Sage X3 Syracuse Missing Authentication for Critical Function in Developer Environment",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@rapid7.com",
          "DATE_PUBLIC": "2021-07-07T13:05:00.000Z",
          "ID": "CVE-2020-7389",
          "STATE": "PUBLIC",
          "TITLE": "Sage X3 Syracuse Missing Authentication for Critical Function in Developer Environment"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "X3",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "V9",
                            "version_value": "Syracuse 9.22.7.2"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "V11",
                            "version_value": "Syracuse 11.25.2.6"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "V12",
                            "version_value": "Syracuse 12.10.2.8"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Sage"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Jonathan Peterson, Aaron Herndon, Cale Black, Ryan Villarrea, and William Vu, all of Rapid7"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Sage X3 System CHAINE Variable Script Command Injection. An authenticated user with developer access can pass OS commands via this variable used by the web application. Note, this developer configuration should not be deployed in production."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306 Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://rapid7.com/blog/post/2021/07/07/sage-x3-multiple-vulnerabilities-fixed",
              "refsource": "MISC",
              "url": "https://rapid7.com/blog/post/2021/07/07/sage-x3-multiple-vulnerabilities-fixed"
            }
          ]
        },
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9974b330-7714-4307-a722-5648477acda7",
    "assignerShortName": "rapid7",
    "cveId": "CVE-2020-7389",
    "datePublished": "2021-07-22T18:27:15.586Z",
    "dateReserved": "2020-01-21T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:53:13.741Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7479 (GCVE-0-2020-7479)

Vulnerability from cvelistv5 – Published: 2020-03-23 19:18 – Updated: 2024-08-04 09:33
VLAI
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service.
Severity
No CVSS data available.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
n/a IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009) Affected: IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.829Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-370/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306:  Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-04-03T18:06:05.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-370/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7479",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "IGSS (Interactive Graphical SCADA System) (IGSS Version prior to 14.0.0.20009)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "IGSS (Interactive Graphical SCADA System) (Versions 14 and prior using the service: IGSSupdate)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in IGSS (Versions 14 and prior using the service: IGSSupdate), which could allow a local user to execute processes that otherwise require escalation privileges when sending local network commands to the IGSS Update Service."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306:  Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/",
              "refsource": "MISC",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-070-01/"
            },
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-20-370/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-20-370/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7479",
    "datePublished": "2020-03-23T19:18:26.000Z",
    "dateReserved": "2020-01-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:33:19.829Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-7540 (GCVE-0-2020-7540)

Vulnerability from cvelistv5 – Published: 2020-12-11 00:52 – Updated: 2024-08-04 09:33
VLAI
Summary
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests.
Severity
No CVSS data available.
CWE
  • CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
Vendor Product Version
n/a Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions) Affected: Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:33:19.892Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-04/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306: Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-12-11T00:52:03.000Z",
        "orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
        "shortName": "schneider"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-04/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cybersecurity@schneider-electric.com",
          "ID": "CVE-2020-7540",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions)"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Web Server on Modicon M340, Legacy Offers Modicon Quantum and Modicon Premium and associated Communication Modules (see security notification for affected versions), that could cause unauthenticated command execution in the controller when sending special HTTP requests."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-306: Missing Authentication for Critical Function"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.se.com/ww/en/download/document/SEVD-2020-343-04/",
              "refsource": "CONFIRM",
              "url": "https://www.se.com/ww/en/download/document/SEVD-2020-343-04/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
    "assignerShortName": "schneider",
    "cveId": "CVE-2020-7540",
    "datePublished": "2020-12-11T00:52:03.000Z",
    "dateReserved": "2020-01-21T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:33:19.892Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Description:

  • Divide the software into anonymous, normal, privileged, and administrative areas. Identify which of these areas require a proven user identity, and use a centralized authentication capability.
  • Identify all potential communication channels, or other means of interaction with the software, to ensure that all channels are appropriately protected, including those channels that are assumed to be accessible only by authorized parties. Developers sometimes perform authentication at the primary channel, but open up a secondary channel that is assumed to be private. For example, a login mechanism may be listening on one network port, but after successful authentication, it may open up a second port where it waits for the connection, but avoids authentication because it assumes that only the authenticated party will connect to the port.
  • In general, if the software or protocol allows a single session or user state to persist across multiple connections or channels, authentication and appropriate credential management need to be used throughout.
Mitigation ID: MIT-15

Phase: Architecture and Design

Description:

  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
Mitigation

Phase: Architecture and Design

Description:

  • Where possible, avoid implementing custom, "grow-your-own" authentication routines and consider using authentication capabilities as provided by the surrounding framework, operating system, or environment. These capabilities may avoid common weaknesses that are unique to authentication; support automatic auditing and tracking; and make it easier to provide a clear separation between authentication tasks and authorization tasks.
  • In environments such as the World Wide Web, the line between authentication and authorization is sometimes blurred. If custom authentication routines are required instead of those provided by the server, then these routines must be applied to every single page, since these pages could be requested directly.
Mitigation ID: MIT-4.5

Phase: Architecture and Design

Strategy: Libraries or Frameworks

Description:

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
  • For example, consider using libraries with authentication capabilities such as OpenSSL or the ESAPI Authenticator [REF-45].
Mitigation

Phases: Implementation, System Configuration, Operation

Description:

  • When storing data in the cloud (e.g., S3 buckets, Azure blobs, Google Cloud Storage, etc.), use the provider's controls to require strong authentication for users who should be allowed to access the data [REF-1297] [REF-1298] [REF-1302].
CAPEC-12: Choosing Message Identifier

This pattern of attack is defined by the selection of messages distributed via multicast or public information channels that are intended for another client by determining the parameter value assigned to that client. This attack allows the adversary to gain access to potentially privileged information, and to possibly perpetrate other attacks through the distribution means by impersonation. If the channel/message being manipulated is an input rather than output mechanism for the system, (such as a command bus), this style of attack could be used to change the adversary's identifier to more a privileged one.

CAPEC-166: Force the System to Reset Values

An attacker forces the target into a previous state in order to leverage potential weaknesses in the target dependent upon a prior configuration or state-dependent factors. Even in cases where an attacker may not be able to directly control the configuration of the targeted application, they may be able to reset the configuration to a prior state since many applications implement reset functions.

CAPEC-216: Communication Channel Manipulation

An adversary manipulates a setting or parameter on communications channel in order to compromise its security. This can result in information exposure, insertion/removal of information from the communications stream, and/or potentially system compromise.

CAPEC-36: Using Unpublished Interfaces or Functionality

An adversary searches for and invokes interfaces or functionality that the target system designers did not intend to be publicly available. If interfaces fail to authenticate requests, the attacker may be able to invoke functionality they are not authorized for.

CAPEC-62: Cross Site Request Forgery

An attacker crafts malicious web links and distributes them (via web pages, email, etc.), typically in a targeted manner, hoping to induce users to click on the link and execute the malicious action against some third-party application. If successful, the action embedded in the malicious link will be processed and accepted by the targeted application with the users' privilege level. This type of attack leverages the persistence and implicit trust placed in user session cookies by many web applications today. In such an architecture, once the user authenticates to an application and a session cookie is created on the user's system, all following transactions for that session are authenticated using that cookie including potential actions initiated by an attacker and simply "riding" the existing session cookie.

Back to CWE stats page