CWE-287

Improper Authentication

When an actor claims to have a given identity, the product does not prove or insufficiently proves that the claim is correct.

CVE-2017-7920 (GCVE-0-2017-7920)

Vulnerability from cvelistv5 – Published: 2017-08-07 08:00 – Updated: 2024-08-05 16:19
VLAI
Summary
An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a ABB VSN300 WiFi Logger Card Affected: ABB VSN300 WiFi Logger Card
Date Public
2017-08-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.337Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "99558",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99558"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ABB VSN300 WiFi Logger Card",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "ABB VSN300 WiFi Logger Card"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-07T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "99558",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99558"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7920",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ABB VSN300 WiFi Logger Card",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "ABB VSN300 WiFi Logger Card"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in ABB VSN300 WiFi Logger Card versions 1.8.15 and prior, and VSN300 WiFi Logger Card for React versions 2.1.3 and prior. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access internal information about status and connected devices without authenticating."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "99558",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99558"
            },
            {
              "name": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
              "refsource": "MISC",
              "url": "http://search.abb.com/library/Download.aspx?DocumentID=9AKK107045A1977\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-192-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7920",
    "datePublished": "2017-08-07T08:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7921 (GCVE-0-2017-7921)

Vulnerability from cvelistv5 – Published: 2017-05-06 00:00 – Updated: 2026-03-06 05:01
VLAI
Summary
An Improper Authentication issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The improper authentication vulnerability occurs when an application does not adequately or correctly authenticate users. This may allow a malicious user to escalate his or her privileges on the system and gain access to sensitive information.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Hikvision Cameras Affected: Hikvision Cameras
Date Public
2017-05-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-12-27T20:39:36.735Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "https://www.hikvision.com/us-en/support/document-center/special-notices/privilege-escalating-vulnerability-in-certain-hikvision-ip-cameras/"
          },
          {
            "url": "https://www.hikvision.com/cn/support/CybersecurityCenter/SecurityNotices/20170314/"
          },
          {
            "url": "https://www.hikvision.com/en/support/cybersecurity/security-advisory/security-notification--privilege-escalating-vulnerability-in-cer/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
          },
          {
            "name": "98313",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/98313"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ghostbin.com/paste/q2vq2"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://www.hikvision.com/us/about_10805.html"
          }
        ],
        "title": "CVE Program Container",
        "x_generator": {
          "engine": "ADPogram 0.0.1"
        }
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2017-7921",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-05T00:00:00+00:00",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2026-03-05",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-7921"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-06T05:01:18.718Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2017-7921"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2026-03-05T00:00:00.000Z",
            "value": "CVE-2017-7921 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Hikvision Cameras",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Hikvision Cameras"
            }
          ]
        }
      ],
      "datePublic": "2017-05-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The improper authentication vulnerability occurs when an application does not adequately or correctly authenticate users. This may allow a malicious user to escalate his or her privileges on the system and gain access to sensitive information."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-12-18T03:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
        },
        {
          "name": "98313",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/98313"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ghostbin.com/paste/q2vq2"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://www.hikvision.com/us/about_10805.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7921",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Hikvision Cameras",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Hikvision Cameras"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in Hikvision DS-2CD2xx2F-I Series V5.2.0 build 140721 to V5.4.0 build 160530, DS-2CD2xx0F-I Series V5.2.0 build 140721 to V5.4.0 Build 160401, DS-2CD2xx2FWD Series V5.3.1 build 150410 to V5.4.4 Build 161125, DS-2CD4x2xFWD Series V5.2.0 build 140721 to V5.4.0 Build 160414, DS-2CD4xx5 Series V5.2.0 build 140721 to V5.4.0 Build 160421, DS-2DFx Series V5.2.0 build 140805 to V5.4.5 Build 160928, and DS-2CD63xx Series V5.0.9 build 140305 to V5.3.5 Build 160106 devices. The improper authentication vulnerability occurs when an application does not adequately or correctly authenticate users. This may allow a malicious user to escalate his or her privileges on the system and gain access to sensitive information."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-124-01"
            },
            {
              "name": "98313",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/98313"
            },
            {
              "name": "https://ghostbin.com/paste/q2vq2",
              "refsource": "MISC",
              "url": "https://ghostbin.com/paste/q2vq2"
            },
            {
              "name": "http://www.hikvision.com/us/about_10805.html",
              "refsource": "MISC",
              "url": "http://www.hikvision.com/us/about_10805.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7921",
    "datePublished": "2017-05-06T00:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2026-03-06T05:01:18.718Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2017-7930 (GCVE-0-2017-7930)

Vulnerability from cvelistv5 – Published: 2017-08-25 19:00 – Updated: 2024-08-05 16:19
VLAI
Summary
An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a OSIsoft PI Server 2017 Affected: OSIsoft PI Server 2017
Date Public
2017-08-25 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.247Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02"
          },
          {
            "name": "99059",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99059"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OSIsoft PI Server 2017",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "OSIsoft PI Server 2017"
            }
          ]
        }
      ],
      "datePublic": "2017-08-25T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-26T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02"
        },
        {
          "name": "99059",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99059"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7930",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OSIsoft PI Server 2017",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "OSIsoft PI Server 2017"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Data Archive has protocol flaws with the potential to expose change records in the clear and allow a malicious party to spoof a server within a collective."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02"
            },
            {
              "name": "99059",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99059"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7930",
    "datePublished": "2017-08-25T19:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.247Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7931 (GCVE-0-2017-7931)

Vulnerability from cvelistv5 – Published: 2018-06-06 20:00 – Updated: 2024-09-17 02:47
VLAI
Summary
In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication.
Severity
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287
Assigner
References
Impacted products
Vendor Product Version
ICS-CERT ABB IP GATEWAY Affected: All versions prior to version 3.39
Create a notification for this product.
Date Public
2018-06-05 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.328Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "104388",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104388"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-156-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "ABB IP GATEWAY",
          "vendor": "ICS-CERT",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 3.39"
            }
          ]
        }
      ],
      "datePublic": "2018-06-05T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-07T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "104388",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104388"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-156-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-06-05T00:00:00",
          "ID": "CVE-2017-7931",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "ABB IP GATEWAY",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 3.39"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "ICS-CERT"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In ABB IP GATEWAY 3.39 and prior, by accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the configuration files and application pages without authentication."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "104388",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104388"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-156-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-156-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7931",
    "datePublished": "2018-06-06T20:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-09-17T02:47:46.978Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7934 (GCVE-0-2017-7934)

Vulnerability from cvelistv5 – Published: 2017-08-25 19:00 – Updated: 2024-08-05 16:19
VLAI
Summary
An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Network Manager using older protocol versions contains a flaw that could allow a malicious user to authenticate with a server and then cause PI Network Manager to behave in an undefined manner.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a OSIsoft PI Server 2017 Affected: OSIsoft PI Server 2017
Date Public
2017-08-25 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.337Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02"
          },
          {
            "name": "99059",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99059"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "OSIsoft PI Server 2017",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "OSIsoft PI Server 2017"
            }
          ]
        }
      ],
      "datePublic": "2017-08-25T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Network Manager using older protocol versions contains a flaw that could allow a malicious user to authenticate with a server and then cause PI Network Manager to behave in an undefined manner."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-26T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02"
        },
        {
          "name": "99059",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99059"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7934",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "OSIsoft PI Server 2017",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "OSIsoft PI Server 2017"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in OSIsoft PI Server 2017 PI Data Archive versions prior to 2017. PI Network Manager using older protocol versions contains a flaw that could allow a malicious user to authenticate with a server and then cause PI Network Manager to behave in an undefined manner."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-164-02"
            },
            {
              "name": "99059",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99059"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7934",
    "datePublished": "2017-08-25T19:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.337Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7937 (GCVE-0-2017-7937)

Vulnerability from cvelistv5 – Published: 2017-05-19 02:43 – Updated: 2024-08-05 16:19
VLAI
Summary
An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Phoenix Contact GmbH mGuard Affected: Phoenix Contact GmbH mGuard
Date Public
2017-05-18 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.218Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Phoenix Contact GmbH mGuard",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Phoenix Contact GmbH mGuard"
            }
          ]
        }
      ],
      "datePublic": "2017-05-18T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-05-19T02:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-7937",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Phoenix Contact GmbH mGuard",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Phoenix Contact GmbH mGuard"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in Phoenix Contact GmbH mGuard firmware versions 8.3.0 to 8.4.2. An attacker may be able to gain unauthorized access to the user firewall when RADIUS servers are unreachable."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-131-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7937",
    "datePublished": "2017-05-19T02:43:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-08-05T16:19:29.218Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9625 (GCVE-0-2017-9625)

Vulnerability from cvelistv5 – Published: 2017-10-17 22:00 – Updated: 2024-08-05 17:11
VLAI
Summary
An Improper Authentication issue was discovered in Envitech EnviDAS Ultimate Versions prior to v1.0.0.5. The web application lacks proper authentication which could allow an attacker to view information and modify settings or execute code remotely.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a Envitech Ltd. EnviDAS Ultimate Affected: Envitech Ltd. EnviDAS Ultimate
Date Public
2017-10-17 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:11:02.334Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101249",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101249"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-285-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Envitech Ltd. EnviDAS Ultimate",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "Envitech Ltd. EnviDAS Ultimate"
            }
          ]
        }
      ],
      "datePublic": "2017-10-17T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in Envitech EnviDAS Ultimate Versions prior to v1.0.0.5. The web application lacks proper authentication which could allow an attacker to view information and modify settings or execute code remotely."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-10-18T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "101249",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/101249"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-285-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9625",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Envitech Ltd. EnviDAS Ultimate",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Envitech Ltd. EnviDAS Ultimate"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in Envitech EnviDAS Ultimate Versions prior to v1.0.0.5. The web application lacks proper authentication which could allow an attacker to view information and modify settings or execute code remotely."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "101249",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/101249"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-285-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-285-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9625",
    "datePublished": "2017-10-17T22:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:11:02.334Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9630 (GCVE-0-2017-9630)

Vulnerability from cvelistv5 – Published: 2017-08-07 08:00 – Updated: 2024-08-05 17:11
VLAI
Summary
An Improper Authentication issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The web server does not properly verify that provided authentication information is correct.
Severity
No CVSS data available.
CWE
Assigner
References
Impacted products
Vendor Product Version
n/a PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch Affected: PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch
Date Public
2017-08-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:11:02.365Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-208-03"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An Improper Authentication issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The web server does not properly verify that provided authentication information is correct."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-07T07:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-208-03"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2017-9630",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "PDQ Manufacturing, Inc. LaserWash, Laser Jet and ProTouch"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "An Improper Authentication issue was discovered in PDQ Manufacturing LaserWash G5 and G5 S Series all versions, LaserWash M5, all versions, LaserWash 360 and 360 Plus, all versions, LaserWash AutoXpress and AutoExpress Plus, all versions, LaserJet, all versions, ProTouch Tandem, all versions, ProTouch ICON, all versions, and ProTouch AutoGloss, all versions. The web server does not properly verify that provided authentication information is correct."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-17-208-03",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-17-208-03"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-9630",
    "datePublished": "2017-08-07T08:00:00.000Z",
    "dateReserved": "2017-06-14T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:11:02.365Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9939 (GCVE-0-2017-9939)

Vulnerability from cvelistv5 – Published: 2017-08-08 00:00 – Updated: 2024-08-05 17:25
VLAI
Summary
A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations.
Severity
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication
Assigner
References
Impacted products
Vendor Product Version
n/a SiPass integrated All versions before V2.70 Affected: SiPass integrated All versions before V2.70
Date Public
2017-08-07 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.591Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"
          },
          {
            "name": "99578",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99578"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SiPass integrated All versions before V2.70",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "SiPass integrated All versions before V2.70"
            }
          ]
        }
      ],
      "datePublic": "2017-08-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2017-08-08T09:57:01.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"
        },
        {
          "name": "99578",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99578"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2017-9939",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SiPass integrated All versions before V2.70",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "SiPass integrated All versions before V2.70"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was discovered in Siemens SiPass integrated (All versions before V2.70) that could allow an attacker with network access to the SiPass integrated server to bypass the authentication mechanism and perform administrative operations."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287: Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-339433.pdf"
            },
            {
              "name": "99578",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99578"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9939",
    "datePublished": "2017-08-08T00:00:00.000Z",
    "dateReserved": "2017-06-26T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:25:00.591Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-9946 (GCVE-0-2017-9946)

Vulnerability from cvelistv5 – Published: 2017-10-23 00:00 – Updated: 2024-08-05 17:25
VLAI
Summary
A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions <V3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device.
Severity
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
n/a APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5 Affected: APOGEE PXC and TALON TC BACnet Automation Controllers All versions <V3.5
Date Public
2017-10-23 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T17:25:00.381Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "101248",
            "tags": [
              "vdb-entry",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/101248"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "APOGEE PXC and TALON TC BACnet Automation Controllers All versions \u003cV3.5"
            }
          ]
        }
      ],
      "datePublic": "2017-10-23T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in Siemens APOGEE PXC and TALON TC BACnet Automation Controllers in all versions \u003cV3.5. An attacker with network access to the integrated web server (80/tcp and 443/tcp) could bypass the authentication and download sensitive information from the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287: Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-10-28T00:00:00.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "name": "101248",
          "tags": [
            "vdb-entry"
          ],
          "url": "http://www.securityfocus.com/bid/101248"
        },
        {
          "url": "https://www.siemens.com/cert/pool/cert/siemens_security_advisory_ssa-148078.pdf"
        },
        {
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-148078.pdf"
        },
        {
          "url": "http://packetstormsecurity.com/files/169544/Siemens-APOGEE-PXC-TALON-TC-Authentication-Bypass.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2017-9946",
    "datePublished": "2017-10-23T00:00:00.000Z",
    "dateReserved": "2017-06-26T00:00:00.000Z",
    "dateUpdated": "2024-08-05T17:25:00.381Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation

Phase: Architecture and Design

Strategy: Libraries or Frameworks

Description:

  • Use an authentication framework or library such as the OWASP ESAPI Authentication feature.
CAPEC-114: Authentication Abuse

An attacker obtains unauthorized access to an application, service or device either through knowledge of the inherent weaknesses of an authentication mechanism, or by exploiting a flaw in the authentication scheme's implementation. In such an attack an authentication mechanism is functioning but a carefully controlled sequence of events causes the mechanism to grant access to the attacker.

CAPEC-115: Authentication Bypass

An attacker gains access to application, service, or device with the privileges of an authorized or privileged user by evading or circumventing an authentication mechanism. The attacker is therefore able to access protected data without authentication ever having taken place.

CAPEC-151: Identity Spoofing

Identity Spoofing refers to the action of assuming (i.e., taking on) the identity of some other entity (human or non-human) and then using that identity to accomplish a goal. An adversary may craft messages that appear to come from a different principle or use stolen / spoofed authentication credentials.

CAPEC-194: Fake the Source of Data

An adversary takes advantage of improper authentication to provide data or services under a falsified identity. The purpose of using the falsified identity may be to prevent traceability of the provided data or to assume the rights granted to another individual. One of the simplest forms of this attack would be the creation of an email message with a modified "From" field in order to appear that the message was sent from someone other than the actual sender. The root of the attack (in this case the email system) fails to properly authenticate the source and this results in the reader incorrectly performing the instructed action. Results of the attack vary depending on the details of the attack, but common results include privilege escalation, obfuscation of other attacks, and data corruption/manipulation.

CAPEC-22: Exploiting Trust in Client

An attack of this type exploits vulnerabilities in client/server communication channel authentication and data integrity. It leverages the implicit trust a server places in the client, or more importantly, that which the server believes is the client. An attacker executes this type of attack by communicating directly with the server where the server believes it is communicating only with a valid client. There are numerous variations of this type of attack.

CAPEC-57: Utilizing REST's Trust in the System Resource to Obtain Sensitive Data

This attack utilizes a REST(REpresentational State Transfer)-style applications' trust in the system resources and environment to obtain sensitive data once SSL is terminated.

CAPEC-593: Session Hijacking

This type of attack involves an adversary that exploits weaknesses in an application's use of sessions in performing authentication. The adversary is able to steal or manipulate an active session and use it to gain unathorized access to the application.

CAPEC-633: Token Impersonation

An adversary exploits a weakness in authentication to create an access token (or equivalent) that impersonates a different entity, and then associates a process/thread to that that impersonated token. This action causes a downstream user to make a decision or take action that is based on the assumed identity, and not the response that blocks the adversary.

CAPEC-650: Upload a Web Shell to a Web Server

By exploiting insufficient permissions, it is possible to upload a web shell to a web server in such a way that it can be executed remotely. This shell can have various capabilities, thereby acting as a "gateway" to the underlying web server. The shell might execute at the higher permission level of the web server, providing the ability the execute malicious code at elevated levels.

CAPEC-94: Adversary in the Middle (AiTM)

An adversary targets the communication between two components (typically client and server), in order to alter or obtain data from transactions. A general approach entails the adversary placing themself within the communication channel between the two components.

Back to CWE stats page