CWE-276
Incorrect Default Permissions
During installation, installed file permissions are set to allow anyone to modify those files.
CVE-2021-20037 (GCVE-0-2021-20037)
Vulnerability from cvelistv5 – Published: 2021-09-21 08:50 – Updated: 2024-08-03 17:30- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://psirt.global.sonicwall.com/vuln-detail/SN… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| SonicWall | SonicWall Global VPN Client |
Affected:
Global VPN Client 4.10.5 and earlier
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:30:07.615Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0024"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SonicWall Global VPN Client",
"vendor": "SonicWall",
"versions": [
{
"status": "affected",
"version": "Global VPN Client 4.10.5 and earlier"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "SonicWall Global VPN Client 4.10.5 installer (32-bit and 64-bit) incorrect default file permission vulnerability leads to privilege escalation which potentially allows command execution in the host operating system. This vulnerability impacts GVC 4.10.5 installer and earlier."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-09-21T08:50:11.000Z",
"orgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
"shortName": "sonicwall"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0024"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "PSIRT@sonicwall.com",
"ID": "CVE-2021-20037",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SonicWall Global VPN Client",
"version": {
"version_data": [
{
"version_value": "Global VPN Client 4.10.5 and earlier"
}
]
}
}
]
},
"vendor_name": "SonicWall"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "SonicWall Global VPN Client 4.10.5 installer (32-bit and 64-bit) incorrect default file permission vulnerability leads to privilege escalation which potentially allows command execution in the host operating system. This vulnerability impacts GVC 4.10.5 installer and earlier."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0024",
"refsource": "CONFIRM",
"url": "https://psirt.global.sonicwall.com/vuln-detail/SNWLID-2021-0024"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "44b2ff79-1416-4492-88bb-ed0da00c7315",
"assignerShortName": "sonicwall",
"cveId": "CVE-2021-20037",
"datePublished": "2021-09-21T08:50:11.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:30:07.615Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-20269 (GCVE-0-2021-20269)
Vulnerability from cvelistv5 – Published: 2022-03-09 16:29 – Updated: 2024-08-03 17:37| URL | Tags |
|---|---|
| https://bugzilla.redhat.com/show_bug.cgi?id=1934261 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | kexec-tools |
Affected:
Fedora kexec-tools versions prior to 2.0.21-8 and RHEL kexec-tools versions prior to 2.0.20-47
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T17:37:23.203Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1934261"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "kexec-tools",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Fedora kexec-tools versions prior to 2.0.21-8 and RHEL kexec-tools versions prior to 2.0.20-47"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A flaw was found in the permissions of a log file created by kexec-tools. This flaw allows a local unprivileged user to read this file and leak kernel internal information from a previous panic. The highest threat from this vulnerability is to confidentiality. This flaw affects kexec-tools shipped by Fedora versions prior to 2.0.21-8 and RHEL versions prior to 2.0.20-47."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-09T16:29:47.000Z",
"orgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"shortName": "redhat"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://bugzilla.redhat.com/show_bug.cgi?id=1934261"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "53f830b8-0a3f-465b-8143-3b8a9948e749",
"assignerShortName": "redhat",
"cveId": "CVE-2021-20269",
"datePublished": "2022-03-09T16:29:47.000Z",
"dateReserved": "2020-12-17T00:00:00.000Z",
"dateUpdated": "2024-08-03T17:37:23.203Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21910 (GCVE-0-2021-21910)
Vulnerability from cvelistv5 – Published: 2021-12-22 18:06 – Updated: 2024-08-03 18:30- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://talosintelligence.com/vulnerability_repor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:30:23.130Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Advantech",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-22T18:06:54.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21910",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Advantech",
"version": {
"version_data": [
{
"version_value": "Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.8,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2021-21910",
"datePublished": "2021-12-22T18:06:54.000Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:30:23.130Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21911 (GCVE-0-2021-21911)
Vulnerability from cvelistv5 – Published: 2021-12-22 18:06 – Updated: 2024-08-03 18:30- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://talosintelligence.com/vulnerability_repor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:30:22.888Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Advantech",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-22T18:06:55.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21911",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Advantech",
"version": {
"version_data": [
{
"version_value": "Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.8,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2021-21911",
"datePublished": "2021-12-22T18:06:55.000Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:30:22.888Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21912 (GCVE-0-2021-21912)
Vulnerability from cvelistv5 – Published: 2021-12-22 18:06 – Updated: 2024-08-03 18:30- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://talosintelligence.com/vulnerability_repor… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:30:22.881Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Advantech",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-22T18:06:55.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21912",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Advantech",
"version": {
"version_data": [
{
"version_value": "Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability exists in the Windows version of installation for Advantech R-SeeNet Advantech R-SeeNet 2.4.15 (30.07.2021). A specially-crafted file can be replaced in the system to escalate privileges to NT SYSTEM authority. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.8,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1360"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2021-21912",
"datePublished": "2021-12-22T18:06:55.000Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:30:22.881Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-21957 (GCVE-0-2021-21957)
Vulnerability from cvelistv5 – Published: 2021-12-08 21:29 – Updated: 2024-08-03 18:30- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://talosintelligence.com/vulnerability_repor… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Dream Report |
Affected:
Dream Report ODS Remote Connector 20.2.16900.0
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:30:23.591Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1384"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Dream Report",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Dream Report ODS Remote Connector 20.2.16900.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A privilege escalation vulnerability exists in the Remote Server functionality of Dream Report ODS Remote Connector 20.2.16900.0. A specially-crafted command injection can lead to elevated capabilities. An attacker can provide a malicious file to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-12-08T21:29:57.000Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1384"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "talos-cna@cisco.com",
"ID": "CVE-2021-21957",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Dream Report",
"version": {
"version_data": [
{
"version_value": "Dream Report ODS Remote Connector 20.2.16900.0"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A privilege escalation vulnerability exists in the Remote Server functionality of Dream Report ODS Remote Connector 20.2.16900.0. A specially-crafted command injection can lead to elevated capabilities. An attacker can provide a malicious file to trigger this vulnerability."
}
]
},
"impact": {
"cvss": {
"baseScore": 8.8,
"baseSeverity": "High",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1384",
"refsource": "MISC",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2021-1384"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2021-21957",
"datePublished": "2021-12-08T21:29:57.000Z",
"dateReserved": "2021-01-04T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:30:23.591Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-22817 (GCVE-0-2021-22817)
Vulnerability from cvelistv5 – Published: 2022-02-09 22:05 – Updated: 2024-08-03 18:51- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://download.schneider-electric.com/files?p_D… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1) |
Affected:
Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T18:51:07.468Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-09T22:05:12.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2021-22817",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)",
"version": {
"version_data": [
{
"version_value": "Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-276: Incorrect Default Permissions vulnerability exists that could cause unauthorized access to the base installation directory leading to local privilege escalation. Affected Product: Harmony/Magelis iPC Series (All Versions), Vijeo Designer (All Versions prior to V6.2 SP11 Multiple HotFix 4), Vijeo Designer Basic (All Versions prior to V1.2.1)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-06",
"refsource": "MISC",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-039-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2021-22817",
"datePublished": "2022-02-09T22:05:12.000Z",
"dateReserved": "2021-01-06T00:00:00.000Z",
"dateUpdated": "2024-08-03T18:51:07.468Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-25317 (GCVE-0-2021-25317)
Vulnerability from cvelistv5 – Published: 2021-05-05 09:35 – Updated: 2024-09-17 00:32- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://bugzilla.suse.com/show_bug.cgi?id=1184161 | |
| https://lists.fedoraproject.org/archives/list/pac… | vendor-advisory |
| https://lists.fedoraproject.org/archives/list/pac… | vendor-advisory |
| https://lists.fedoraproject.org/archives/list/pac… | vendor-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| SUSE | SUSE Linux Enterprise Server 11-SP4-LTSS |
Affected:
cups , < 1.3.9
(custom)
|
|
| SUSE | SUSE Manager Server 4.0 |
Affected:
cups , < 2.2.7
(custom)
|
|
| SUSE | SUSE OpenStack Cloud Crowbar 9 |
Affected:
cups , < 1.7.5
(custom)
|
|
| openSUSE | openSUSE Leap 15.2 |
Affected:
cups , < 2.2.7
(custom)
|
|
| openSUSE | Factory |
Affected:
cups , ≤ 2.3.3op2-2.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:03:04.109Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1184161"
},
{
"name": "FEDORA-2021-dc578ce534",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/H74BP746O5NNVCBUTLLZYAFBPESFVECV/"
},
{
"name": "FEDORA-2021-7b698513d5",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/S37IDQGHTORQ3Z6VRDQIGBYVOI27YG47/"
},
{
"name": "FEDORA-2021-be95e017e7",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GWPGZLT3U776Q5YPPSA6LGFWWBDWBVH3/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SUSE Linux Enterprise Server 11-SP4-LTSS",
"vendor": "SUSE",
"versions": [
{
"lessThan": "1.3.9",
"status": "affected",
"version": "cups",
"versionType": "custom"
}
]
},
{
"product": "SUSE Manager Server 4.0",
"vendor": "SUSE",
"versions": [
{
"lessThan": "2.2.7",
"status": "affected",
"version": "cups",
"versionType": "custom"
}
]
},
{
"product": "SUSE OpenStack Cloud Crowbar 9",
"vendor": "SUSE",
"versions": [
{
"lessThan": "1.7.5",
"status": "affected",
"version": "cups",
"versionType": "custom"
}
]
},
{
"product": "openSUSE Leap 15.2",
"vendor": "openSUSE",
"versions": [
{
"lessThan": "2.2.7",
"status": "affected",
"version": "cups",
"versionType": "custom"
}
]
},
{
"product": "Factory",
"vendor": "openSUSE",
"versions": [
{
"lessThanOrEqual": "2.3.3op2-2.1",
"status": "affected",
"version": "cups",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Matthias Gerstner of SUSE"
}
],
"datePublic": "2021-04-30T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Incorrect Default Permissions vulnerability in the packaging of cups of SUSE Linux Enterprise Server 11-SP4-LTSS, SUSE Manager Server 4.0, SUSE OpenStack Cloud Crowbar 9; openSUSE Leap 15.2, Factory allows local attackers with control of the lp users to create files as root with 0644 permissions without the ability to set the content. This issue affects: SUSE Linux Enterprise Server 11-SP4-LTSS cups versions prior to 1.3.9. SUSE Manager Server 4.0 cups versions prior to 2.2.7. SUSE OpenStack Cloud Crowbar 9 cups versions prior to 1.7.5. openSUSE Leap 15.2 cups versions prior to 2.2.7. openSUSE Factory cups version 2.3.3op2-2.1 and prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-01-19T00:00:00.000Z",
"orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
"shortName": "suse"
},
"references": [
{
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1184161"
},
{
"name": "FEDORA-2021-dc578ce534",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/H74BP746O5NNVCBUTLLZYAFBPESFVECV/"
},
{
"name": "FEDORA-2021-7b698513d5",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/S37IDQGHTORQ3Z6VRDQIGBYVOI27YG47/"
},
{
"name": "FEDORA-2021-be95e017e7",
"tags": [
"vendor-advisory"
],
"url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GWPGZLT3U776Q5YPPSA6LGFWWBDWBVH3/"
}
],
"source": {
"advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1184161",
"defect": [
"1184161"
],
"discovery": "INTERNAL"
},
"title": "cups: ownership of /var/log/cups allows the lp user to create files as root",
"x_generator": {
"engine": "Vulnogram 0.0.9"
}
}
},
"cveMetadata": {
"assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
"assignerShortName": "suse",
"cveId": "CVE-2021-25317",
"datePublished": "2021-05-05T09:35:13.321Z",
"dateReserved": "2021-01-19T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:32:16.952Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-25319 (GCVE-0-2021-25319)
Vulnerability from cvelistv5 – Published: 2021-05-05 08:25 – Updated: 2024-09-16 22:24- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://bugzilla.suse.com/show_bug.cgi?id=1182918 | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:03:04.759Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1182918"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Factory",
"vendor": "openSUSE",
"versions": [
{
"lessThanOrEqual": "6.1.20-1.1",
"status": "affected",
"version": "virtualbox",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Matthias Gerstner of SUSE"
}
],
"datePublic": "2021-04-26T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A Incorrect Default Permissions vulnerability in the packaging of virtualbox of openSUSE Factory allows local attackers in the vboxusers groupu to escalate to root. This issue affects: openSUSE Factory virtualbox version 6.1.20-1.1 and prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276: Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-05-05T08:25:13.000Z",
"orgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
"shortName": "suse"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1182918"
}
],
"source": {
"advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1182918",
"defect": [
"1182918"
],
"discovery": "INTERNAL"
},
"title": "virtualbox: missing sticky bit for /etc/vbox allows local root exploit for members of vboxusers group",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@suse.com",
"DATE_PUBLIC": "2021-04-26T00:00:00.000Z",
"ID": "CVE-2021-25319",
"STATE": "PUBLIC",
"TITLE": "virtualbox: missing sticky bit for /etc/vbox allows local root exploit for members of vboxusers group"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Factory",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "virtualbox",
"version_value": "6.1.20-1.1"
}
]
}
}
]
},
"vendor_name": "openSUSE"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Matthias Gerstner of SUSE"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A Incorrect Default Permissions vulnerability in the packaging of virtualbox of openSUSE Factory allows local attackers in the vboxusers groupu to escalate to root. This issue affects: openSUSE Factory virtualbox version 6.1.20-1.1 and prior versions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276: Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://bugzilla.suse.com/show_bug.cgi?id=1182918",
"refsource": "CONFIRM",
"url": "https://bugzilla.suse.com/show_bug.cgi?id=1182918"
}
]
},
"source": {
"advisory": "https://bugzilla.suse.com/show_bug.cgi?id=1182918",
"defect": [
"1182918"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "404e59f5-483d-4b8a-8e7a-e67604dd8afb",
"assignerShortName": "suse",
"cveId": "CVE-2021-25319",
"datePublished": "2021-05-05T08:25:13.677Z",
"dateReserved": "2021-01-19T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:24:55.435Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-3155 (GCVE-0-2021-3155)
Vulnerability from cvelistv5 – Published: 2022-02-17 22:15 – Updated: 2024-08-03 16:45- CWE-276 - Incorrect Default Permissions
| URL | Tags |
|---|---|
| https://ubuntu.com/security/notices/USN-5292-1 | x_refsource_MISC |
| https://github.com/snapcore/snapd/commit/6bcaeecc… | x_refsource_MISC |
| https://github.com/snapcore/snapd/commit/7d2a9666… | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Canonical Ltd. | snapd |
Affected:
unspecified , ≤ 2.54.2
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T16:45:51.372Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://ubuntu.com/security/notices/USN-5292-1"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/snapcore/snapd/commit/6bcaeeccd16ed8298a301dd92f6907f88c24cc85"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://github.com/snapcore/snapd/commit/7d2a966620002149891446a53cf114804808dcca"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "snapd",
"vendor": "Canonical Ltd.",
"versions": [
{
"lessThanOrEqual": "2.54.2",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "James Troup"
}
],
"descriptions": [
{
"lang": "en",
"value": "snapd 2.54.2 and earlier created ~/snap directories in user home directories without specifying owner-only permissions. This could allow a local attacker to read information that should have been private. Fixed in snapd versions 2.54.3+18.04, 2.54.3+20.04 and 2.54.3+21.10.1"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-276",
"description": "CWE-276 Incorrect Default Permissions",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-02-17T22:15:16.000Z",
"orgId": "cc1ad9ee-3454-478d-9317-d3e869d708bc",
"shortName": "canonical"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://ubuntu.com/security/notices/USN-5292-1"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/snapcore/snapd/commit/6bcaeeccd16ed8298a301dd92f6907f88c24cc85"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://github.com/snapcore/snapd/commit/7d2a966620002149891446a53cf114804808dcca"
}
],
"source": {
"discovery": "USER"
},
"title": "snapd created ~/snap with too-wide permissions",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@ubuntu.com",
"ID": "CVE-2021-3155",
"STATE": "PUBLIC",
"TITLE": "snapd created ~/snap with too-wide permissions"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "snapd",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "2.54.2"
}
]
}
}
]
},
"vendor_name": "Canonical Ltd."
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "James Troup"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "snapd 2.54.2 and earlier created ~/snap directories in user home directories without specifying owner-only permissions. This could allow a local attacker to read information that should have been private. Fixed in snapd versions 2.54.3+18.04, 2.54.3+20.04 and 2.54.3+21.10.1"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 3.8,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-276 Incorrect Default Permissions"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://ubuntu.com/security/notices/USN-5292-1",
"refsource": "MISC",
"url": "https://ubuntu.com/security/notices/USN-5292-1"
},
{
"name": "https://github.com/snapcore/snapd/commit/6bcaeeccd16ed8298a301dd92f6907f88c24cc85",
"refsource": "MISC",
"url": "https://github.com/snapcore/snapd/commit/6bcaeeccd16ed8298a301dd92f6907f88c24cc85"
},
{
"name": "https://github.com/snapcore/snapd/commit/7d2a966620002149891446a53cf114804808dcca",
"refsource": "MISC",
"url": "https://github.com/snapcore/snapd/commit/7d2a966620002149891446a53cf114804808dcca"
}
]
},
"source": {
"discovery": "USER"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cc1ad9ee-3454-478d-9317-d3e869d708bc",
"assignerShortName": "canonical",
"cveId": "CVE-2021-3155",
"datePublished": "2022-02-17T22:15:16.000Z",
"dateReserved": "2021-01-15T00:00:00.000Z",
"dateUpdated": "2024-08-03T16:45:51.372Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-1
Phases: Architecture and Design, Operation
Description:
- The architecture needs to access and modification attributes for files to only those users who actually require those actions.
Mitigation ID: MIT-46
Phase: Architecture and Design
Strategy: Separation of Privilege
Description:
- Compartmentalize the system to have "safe" areas where trust boundaries can be unambiguously drawn. Do not allow sensitive data to go outside of the trust boundary and always be careful when interfacing with a compartment outside of the safe area.
- Ensure that appropriate compartmentalization is built into the system design, and the compartmentalization allows for and reinforces privilege separation functionality. Architects and designers should rely on the principle of least privilege to decide the appropriate time to use privileges and the time to drop privileges.
CAPEC-1: Accessing Functionality Not Properly Constrained by ACLs
In applications, particularly web applications, access to functionality is mitigated by an authorization framework. This framework maps Access Control Lists (ACLs) to elements of the application's functionality; particularly URL's for web apps. In the case that the administrator failed to specify an ACL for a particular element, an attacker may be able to access it with impunity. An attacker with the ability to access functionality not properly constrained by ACLs can obtain sensitive information and possibly compromise the entire application. Such an attacker can access resources that must be available only to users at a higher privilege level, can access management sections of the application, or can run queries for data that they otherwise not supposed to.
CAPEC-127: Directory Indexing
An adversary crafts a request to a target that results in the target listing/indexing the content of a directory as output. One common method of triggering directory contents as output is to construct a request containing a path that terminates in a directory name rather than a file name since many applications are configured to provide a list of the directory's contents when such a request is received. An adversary can use this to explore the directory tree on a target as well as learn the names of files. This can often end up revealing test files, backup files, temporary files, hidden files, configuration files, user accounts, script contents, as well as naming conventions, all of which can be used by an attacker to mount additional attacks.
CAPEC-81: Web Server Logs Tampering
Web Logs Tampering attacks involve an attacker injecting, deleting or otherwise tampering with the contents of web logs typically for the purposes of masking other malicious behavior. Additionally, writing malicious data to log files may target jobs, filters, reports, and other agents that process the logs in an asynchronous attack pattern. This pattern of attack is similar to "Log Injection-Tampering-Forging" except that in this case, the attack is targeting the logs of the web server and not the application.