CWE-1392
Use of Default Credentials
The product uses default credentials (such as passwords or cryptographic keys) for potentially critical functionality.
CVE-2024-39584 (GCVE-0-2024-39584)
Vulnerability from cvelistv5 – Published: 2024-08-28 05:46 – Updated: 2024-08-28 14:15
VLAI
Summary
Dell Client Platform BIOS contains a Use of Default Cryptographic Key Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Secure Boot bypass and arbitrary code execution.
Severity
8.2 (High)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.dell.com/support/kbdoc/en-us/00022759… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Dell | Dell Client Platform BIOS |
Affected:
N/A , < 1.29.0
(semver)
Affected: N/A , < 1.15.0 (semver) Affected: N/A , < 1.21.0 (semver) Affected: N/A , < 1.24.0 (semver) |
Date Public
2024-08-27 06:30
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:dell:alienware_area_51m_r2_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:dell:alienware_m15_r3_firmware:-:*:*:*:*:*:*:*",
"cpe:2.3:o:dell:alienware_m17_r3_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "alienware_m17_r3_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "1.29.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:dell:alienware_aurora_r15_amd_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "alienware_aurora_r15_amd_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "1.15.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:dell:alienware_x14_firmware:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "alienware_x14_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "1.21.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
},
{
"cpes": [
"cpe:2.3:o:dell:alienware_x17_r1_firmware:*:*:*:*:*:*:*:*",
"cpe:2.3:o:dell:alienware_x15_r1_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "alienware_x15_r1_firmware",
"vendor": "dell",
"versions": [
{
"lessThan": "1.24.0",
"status": "affected",
"version": "0",
"versionType": "semver"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39584",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-28T14:02:49.780082Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T14:15:01.978Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Dell Client Platform BIOS",
"vendor": "Dell",
"versions": [
{
"lessThan": "1.29.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.15.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.21.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
},
{
"lessThan": "1.24.0",
"status": "affected",
"version": "N/A",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "CVE-2024-39584: Dell Technologies would like to thank BINARLY REsearch team for reporting this issue."
}
],
"datePublic": "2024-08-27T06:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Dell Client Platform BIOS contains a Use of Default Cryptographic Key Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Secure Boot bypass and arbitrary code execution."
}
],
"value": "Dell Client Platform BIOS contains a Use of Default Cryptographic Key Vulnerability. A high privileged attacker with local access could potentially exploit this vulnerability, leading to Secure Boot bypass and arbitrary code execution."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-28T05:46:40.013Z",
"orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"shortName": "dell"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.dell.com/support/kbdoc/en-us/000227594/dsa-2024-354"
}
],
"source": {
"discovery": "UNKNOWN"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
"assignerShortName": "dell",
"cveId": "CVE-2024-39584",
"datePublished": "2024-08-28T05:46:40.013Z",
"dateReserved": "2024-06-26T02:16:08.993Z",
"dateUpdated": "2024-08-28T14:15:01.978Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-39747 (GCVE-0-2024-39747)
Vulnerability from cvelistv5 – Published: 2024-08-31 01:01 – Updated: 2024-09-01 21:30
VLAI
Title
IBM Sterling Connect:Direct Web Services information disclosure
Summary
IBM Sterling Connect:Direct Web Services 6.0, 6.1, 6.2, and 6.3 uses default credentials for potentially critical functionality.
Severity
8.1 (High)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.ibm.com/support/pages/node/7166947 | vendor-advisory |
| https://exchange.xforce.ibmcloud.com/vulnerabilit… | vdb-entry |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| IBM | Sterling Connect:Direct Web Services |
Affected:
6.0, 6.1, 6.2, 6.3
cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.0.0.0:*:*:*:*:windows:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.1.0.0:*:*:*:*:windows:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.2.0.0:*:*:*:*:windows:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.3.0.0:*:*:*:*:windows:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.0.0.0:*:*:*:*:unix:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.1.0.0:*:*:*:*:unix:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.2.0.0:*:*:*:*:unix:*:* cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.3.0.0:*:*:*:*:unix:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-39747",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-09-01T21:29:57.324770Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-09-01T21:30:21.072Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"cpes": [
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.0.0.0:*:*:*:*:windows:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.1.0.0:*:*:*:*:windows:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.2.0.0:*:*:*:*:windows:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.3.0.0:*:*:*:*:windows:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.0.0.0:*:*:*:*:unix:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.1.0.0:*:*:*:*:unix:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.2.0.0:*:*:*:*:unix:*:*",
"cpe:2.3:a:ibm:sterling_connect_direct_web_services:6.3.0.0:*:*:*:*:unix:*:*"
],
"defaultStatus": "unaffected",
"product": "Sterling Connect:Direct Web Services",
"vendor": "IBM",
"versions": [
{
"status": "affected",
"version": "6.0, 6.1, 6.2, 6.3"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "IBM Sterling Connect:Direct Web Services 6.0, 6.1, 6.2, and 6.3 uses default credentials for potentially critical functionality."
}
],
"value": "IBM Sterling Connect:Direct Web Services 6.0, 6.1, 6.2, and 6.3 uses default credentials for potentially critical functionality."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-08-31T01:01:03.974Z",
"orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"shortName": "ibm"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.ibm.com/support/pages/node/7166947"
},
{
"tags": [
"vdb-entry"
],
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/297314"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "IBM Sterling Connect:Direct Web Services information disclosure",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
"assignerShortName": "ibm",
"cveId": "CVE-2024-39747",
"datePublished": "2024-08-31T01:01:03.974Z",
"dateReserved": "2024-06-28T09:34:46.057Z",
"dateUpdated": "2024-09-01T21:30:21.072Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4007 (GCVE-0-2024-4007)
Vulnerability from cvelistv5 – Published: 2024-07-01 12:06 – Updated: 2024-08-01 20:26
VLAI
Title
Hard coded default credential contained in install package
Summary
Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured.
Severity
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
Impacted products
3 products
| Vendor | Product | Version | |
|---|---|---|---|
| ABB | ASPECT Enterprise (ASP-ENT-x) |
Affected:
3.07
|
|
| ABB | NEXUS Series (NEX-2x, NEXUS-3-x) |
Affected:
3.07
|
|
| ABB | MATRIX Series(MAT-x) |
Affected:
3.07
|
Date Public
2024-07-01 03:30
Credits
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:o:abb:aspect-ent-2_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "aspect-ent-2_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:aspect-ent-96_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "aspect-ent-96_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-2128-a_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-2128-a_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-2128-f_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-2128-f_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-2128_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-2128_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-2128-g_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-2128-g_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-264-a_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-264-a_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-264-f_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-264-f_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-264_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-264_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-264-g_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "nexus-264-g_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-3-2128_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-3-2128_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:nexus-3-264_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "nexus-3-264_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:matrix-11_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "matrix-11_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:matrix-216_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "matrix-216_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:matrix-232_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "matrix-232_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:matrix-264_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "matrix-264_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:aspect-ent-12_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "aspect-ent-12_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:aspect-ent-256_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "aspect-ent-256_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:abb:matrix-296_firmware:3.0.0:*:*:*:*:*:*:*"
],
"defaultStatus": "unaffected",
"product": "matrix-296_firmware",
"vendor": "abb",
"versions": [
{
"lessThan": "3.07.02",
"status": "affected",
"version": "3.0.0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4007",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-02T19:33:48.062617Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-03T14:13:05.048Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T20:26:57.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108469A6101\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://new.abb.com/low-voltage/de/produkte/gebaeudeautomation/produktsortiment/cylon/produkte/aspect-enterprise",
"defaultStatus": "unaffected",
"packageName": "Installer",
"platforms": [
"Linux"
],
"product": "ASPECT Enterprise (ASP-ENT-x)",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "3.07"
}
]
},
{
"collectionURL": "https://new.abb.com/low-voltage/de/produkte/gebaeudeautomation/produktsortiment/cylon/produkte/nexus-series",
"defaultStatus": "unaffected",
"packageName": "Installer",
"platforms": [
"Linux"
],
"product": "NEXUS Series (NEX-2x, NEXUS-3-x)",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "3.07"
}
]
},
{
"collectionURL": "https://new.abb.com/low-voltage/de/produkte/gebaeudeautomation/produktsortiment/cylon/produkte/matrix",
"defaultStatus": "unaffected",
"packageName": "Installer",
"platforms": [
"Linux"
],
"product": "MATRIX Series(MAT-x)",
"vendor": "ABB",
"versions": [
{
"status": "affected",
"version": "3.07"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "ABB likes to thank https://divd.nl for reporting the vulnerability in responsible disclosure."
}
],
"datePublic": "2024-07-01T03:30:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured.\u003cbr\u003e"
}
],
"value": "Default credential in install package in ABB ASPECT; NEXUS Series; MATRIX Series version 3.07 allows attacker to login to product instances wrongly configured."
}
],
"impacts": [
{
"capecId": "CAPEC-49",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-49 Password Brute Forcing"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NO",
"Recovery": "USER",
"Safety": "NEGLIGIBLE",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "RED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "DIFFUSE",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/S:N/AU:N/R:U/V:D/RE:L/U:Red",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "LOW"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-02T00:10:15.764Z",
"orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"shortName": "ABB"
},
"references": [
{
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108469A6101\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nABB Strongly recommends the following actions on any released SW version of ASPECT:\n- Change the PHPmyAdmin Password according to the system manual:\u0026nbsp; All customers who operate the ASPECT System with its default password are recommended to replace this default password with a unique, secure password, containing a\nmix of characters, numbers, and special characters with at least 10 characters in length.\n- Never expose open ports to the ASPECT product towards the Internet or any insecure network.\n- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs).\nRecognize that VPNs may have vulnerabilities and should be updated to the most current version\navailable. Also, understand that VPNs are only as secure as the connected devices.\n- ABB recommends that customers shall apply the latest product update at the earliest convenience.\n\n\n\u003cbr\u003e"
}
],
"value": "ABB Strongly recommends the following actions on any released SW version of ASPECT:\n- Change the PHPmyAdmin Password according to the system manual:\u00a0 All customers who operate the ASPECT System with its default password are recommended to replace this default password with a unique, secure password, containing a\nmix of characters, numbers, and special characters with at least 10 characters in length.\n- Never expose open ports to the ASPECT product towards the Internet or any insecure network.\n- When remote access is required, use secure methods, such as Virtual Private Networks (VPNs).\nRecognize that VPNs may have vulnerabilities and should be updated to the most current version\navailable. Also, understand that VPNs are only as secure as the connected devices.\n- ABB recommends that customers shall apply the latest product update at the earliest convenience."
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Hard coded default credential contained in install package",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nASPECT system shall not be connected directly to untrusted networks such as the Internet.\nIf remote access to an ASPECT system is a customer requirement, the system shall operate behind a firewall. User accessing ASPECT remotely shall do this using a VPN Gateway allowing access to the particular\nnetwork segment where ASPECT is installed and configured in.\nNote: it is crucial that the VPN Gateway and Network is setup in accordance with best industry standards and maintained in terms of security patches for all related components.\nAny default credentials shall be exchanged with a unique credential supporting adequate strength. \n\n\u003cbr\u003e"
}
],
"value": "ASPECT system shall not be connected directly to untrusted networks such as the Internet.\nIf remote access to an ASPECT system is a customer requirement, the system shall operate behind a firewall. User accessing ASPECT remotely shall do this using a VPN Gateway allowing access to the particular\nnetwork segment where ASPECT is installed and configured in.\nNote: it is crucial that the VPN Gateway and Network is setup in accordance with best industry standards and maintained in terms of security patches for all related components.\nAny default credentials shall be exchanged with a unique credential supporting adequate strength."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
"assignerShortName": "ABB",
"cveId": "CVE-2024-4007",
"datePublished": "2024-07-01T12:06:53.048Z",
"dateReserved": "2024-04-19T17:08:37.839Z",
"dateUpdated": "2024-08-01T20:26:57.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-45068 (GCVE-0-2024-45068)
Vulnerability from cvelistv5 – Published: 2024-12-03 02:32 – Updated: 2024-12-03 15:54
VLAI
Title
Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA
Summary
Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.
This issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01.
Severity
7.1 (High)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.hitachi.com/products/it/software/secu… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi | Hitachi Ops Center Common Services |
Affected:
10.9.3-00 , < 11.0.3-00
(custom)
|
|
| Hitachi | Hitachi Ops Center OVA |
Affected:
10.9.3-00 , < 11.0.2-01
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:hitachi:ops_center_ova:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ops_center_ova",
"vendor": "hitachi",
"versions": [
{
"lessThan": "11.0.2-01",
"status": "affected",
"version": "10.9.3-00",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:a:hitachi:ops_center_common_services:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "ops_center_common_services",
"vendor": "hitachi",
"versions": [
{
"lessThan": "11.0.3-00",
"status": "affected",
"version": "10.9.3-00",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-45068",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-03T14:30:59.837741Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-03T15:54:53.646Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "Hitachi Ops Center Common Services",
"vendor": "Hitachi",
"versions": [
{
"changes": [
{
"at": "11.0.3-00",
"status": "unaffected"
}
],
"lessThan": "11.0.3-00",
"status": "affected",
"version": "10.9.3-00",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "Hitachi Ops Center OVA",
"vendor": "Hitachi",
"versions": [
{
"changes": [
{
"at": "11.0.2-01",
"status": "unaffected"
}
],
"lessThan": "11.0.2-01",
"status": "affected",
"version": "10.9.3-00",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eAuthentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.\u003cbr\u003e\u003c/p\u003e\u003cp\u003eThis issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01.\u003c/p\u003e"
}
],
"value": "Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA.\n\n\nThis issue affects Hitachi Ops Center Common Services: from 10.9.3-00 before 11.0.3-00; Hitachi Ops Center OVA: from 10.9.3-00 before 11.0.2-01."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392 Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-03T02:32:03.225Z",
"orgId": "50d0f415-c707-4733-9afc-8f6c0e9b3f82",
"shortName": "Hitachi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.hitachi.com/products/it/software/security/info/vuls/hitachi-sec-2024-149/index.html"
}
],
"source": {
"advisory": "hitachi-sec-2024-149",
"discovery": "UNKNOWN"
},
"title": "Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center OVA",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "50d0f415-c707-4733-9afc-8f6c0e9b3f82",
"assignerShortName": "Hitachi",
"cveId": "CVE-2024-45068",
"datePublished": "2024-12-03T02:32:03.225Z",
"dateReserved": "2024-10-22T04:20:15.307Z",
"dateUpdated": "2024-12-03T15:54:53.646Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-4622 (GCVE-0-2024-4622)
Vulnerability from cvelistv5 – Published: 2024-05-15 16:54 – Updated: 2025-03-27 16:07
VLAI
Title
alpitronic Hypercharger EV Charger Use of Default Credentials
Summary
If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface
protected by authentication. If the default credentials are not changed,
an attacker can use public knowledge to access the device as an
administrator.
Severity
CWE
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| alpitronic | Hypercharger EV Charger |
Affected:
all versions
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-4622",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-15T17:32:04.444201Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:54:05.980Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2025-03-27T16:07:24.605Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://industrydecarbonization.com/news/insecure-password-allowed-administrative-access-to-electric-vehicle-chargers.html"
},
{
"tags": [
"x_transferred"
],
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-130-02"
}
],
"title": "CVE Program Container",
"x_generator": {
"engine": "ADPogram 0.0.1"
}
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Hypercharger EV Charger",
"vendor": "alpitronic",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Hanno B\u00f6ck reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\nIf misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface \nprotected by authentication. If the default credentials are not changed,\n an attacker can use public knowledge to access the device as an \nadministrator.\n\n"
}
],
"value": "If misconfigured, alpitronic Hypercharger EV charging devices can expose a web interface \nprotected by authentication. If the default credentials are not changed,\n an attacker can use public knowledge to access the device as an \nadministrator."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "PRESENT",
"attackVector": "NETWORK",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:L/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T16:54:08.150Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-130-02"
}
],
"source": {
"advisory": "ICSA-24-130-02",
"discovery": "EXTERNAL"
},
"title": "alpitronic Hypercharger EV Charger Use of Default Credentials",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\u003cp\u003ealpitronic recommends users change the default credentials for all charging devices.\u003c/p\u003e\n\u003cp\u003ealpitronic advises that the interface should be connected only to \ninternal segregated and access-controlled networks and not exposed to \nthe public internet/web.\u003c/p\u003e\n\u003cp\u003eWhen informed of these vulnerabilities, alpitronic, in conjunction \nwith and/or on behalf of affected clients, disabled the interface on any\n exposed devices and all clients were contacted directly and reminded \nthat the interface is not intended to be visible on the public Internet \nand that default passwords should be changed.\u003c/p\u003e\n\u003cp\u003ealpitronic are also applying mitigations to all devices in the field \nand to new devices in production. New devices will come with unique \npasswords. Devices using the default password will be automatically \nassigned new unique passwords, or at first access if the device has not \nyet been installed. Devices with the default passwords already changed \nwill not be affected. New passwords can be obtained by scanning the \nQR-Code inside the charger or in DMS portal hyperdoc. Contact \nHypercharger support with any questions about newly assigned passwords.\u003c/p\u003e\n\n"
}
],
"value": "alpitronic recommends users change the default credentials for all charging devices.\n\n\nalpitronic advises that the interface should be connected only to \ninternal segregated and access-controlled networks and not exposed to \nthe public internet/web.\n\n\nWhen informed of these vulnerabilities, alpitronic, in conjunction \nwith and/or on behalf of affected clients, disabled the interface on any\n exposed devices and all clients were contacted directly and reminded \nthat the interface is not intended to be visible on the public Internet \nand that default passwords should be changed.\n\n\nalpitronic are also applying mitigations to all devices in the field \nand to new devices in production. New devices will come with unique \npasswords. Devices using the default password will be automatically \nassigned new unique passwords, or at first access if the device has not \nyet been installed. Devices with the default passwords already changed \nwill not be affected. New passwords can be obtained by scanning the \nQR-Code inside the charger or in DMS portal hyperdoc. Contact \nHypercharger support with any questions about newly assigned passwords."
}
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-4622",
"datePublished": "2024-05-15T16:54:08.150Z",
"dateReserved": "2024-05-07T19:41:26.741Z",
"dateUpdated": "2025-03-27T16:07:24.605Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-46899 (GCVE-0-2024-46899)
Vulnerability from cvelistv5 – Published: 2025-04-22 04:12 – Updated: 2025-04-22 13:24
VLAI
Title
Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF
Summary
Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04.
Severity
7.1 (High)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
| URL | Tags |
|---|---|
| https://www.hitachi.com/products/it/software/secu… | vendor-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Hitachi | Hitachi Ops Center Common Services |
Affected:
10.0.0-00 , < 11.0.0-04
(custom)
|
|
| Hitachi | Hitachi Ops Center Analyzer viewpoint OVF |
Affected:
10.0.0-00 , < 11.0.0-04
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-46899",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-22T13:24:11.598018Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T13:24:20.750Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "Hitachi Ops Center Common Services",
"vendor": "Hitachi",
"versions": [
{
"changes": [
{
"at": "11.0.0-04",
"status": "unaffected"
}
],
"lessThan": "11.0.0-04",
"status": "affected",
"version": "10.0.0-00",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"platforms": [
"Linux"
],
"product": "Hitachi Ops Center Analyzer viewpoint OVF",
"vendor": "Hitachi",
"versions": [
{
"changes": [
{
"at": "11.0.4-00",
"status": "unaffected"
}
],
"lessThan": "11.0.0-04",
"status": "affected",
"version": "10.0.0-00",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.\u003cp\u003eThis issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04.\u003c/p\u003e"
}
],
"value": "Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF contains an authentication credentials leakage vulnerability.This issue affects Hitachi Ops Center Common Services: from 10.0.0-00 before 11.0.0-04; Hitachi Ops Center Analyzer viewpoint OVF: from 10.0.0-00 before 11.0.0-04."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392 Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T04:12:56.387Z",
"orgId": "50d0f415-c707-4733-9afc-8f6c0e9b3f82",
"shortName": "Hitachi"
},
"references": [
{
"tags": [
"vendor-advisory"
],
"url": "https://www.hitachi.com/products/it/software/security/info/vuls/hitachi-sec-2025-111/index.html"
}
],
"source": {
"advisory": "hitachi-sec-2025-111",
"discovery": "UNKNOWN"
},
"title": "Authentication credentials leakage vulnerability in Hitachi Ops Center Common Services within Hitachi Ops Center Analyzer viewpoint OVF",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "50d0f415-c707-4733-9afc-8f6c0e9b3f82",
"assignerShortName": "Hitachi",
"cveId": "CVE-2024-46899",
"datePublished": "2025-04-22T04:12:56.387Z",
"dateReserved": "2024-10-22T04:20:15.324Z",
"dateUpdated": "2025-04-22T13:24:20.750Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5245 (GCVE-0-2024-5245)
Vulnerability from cvelistv5 – Published: 2024-05-23 22:07 – Updated: 2024-08-01 21:03
VLAI
Title
NETGEAR ProSAFE Network Management System Default Credentials Local Privilege Escalation Vulnerability
Summary
NETGEAR ProSAFE Network Management System Default Credentials Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.
The specific flaw exists within the product installer. The issue results from the use of default MySQL credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22755.
Severity
7.8 (High)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.zerodayinitiative.com/advisories/ZDI-… | x_research-advisory |
| https://kb.netgear.com/000066164/Security-Advisor… | vendor-advisory |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| NETGEAR | ProSAFE Network Management System |
Affected:
1.7.0.34 x64
|
Date Public
2024-05-22 23:31
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:netgear:prosafe_network_management_system:1.7.0.34:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "prosafe_network_management_system",
"vendor": "netgear",
"versions": [
{
"status": "affected",
"version": "1.7.0.34 x64"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5245",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-24T19:43:24.161448Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T18:02:10.251Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:03:11.107Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "ZDI-24-496",
"tags": [
"x_research-advisory",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-496/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory",
"x_transferred"
],
"url": "https://kb.netgear.com/000066164/Security-Advisory-for-Multiple-Vulnerabilities-on-the-NMS300-PSV-2024-0003-PSV-2024-0004"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "ProSAFE Network Management System",
"vendor": "NETGEAR",
"versions": [
{
"status": "affected",
"version": "1.7.0.34 x64"
}
]
}
],
"dateAssigned": "2024-05-22T21:06:18.361Z",
"datePublic": "2024-05-22T23:31:56.929Z",
"descriptions": [
{
"lang": "en",
"value": "NETGEAR ProSAFE Network Management System Default Credentials Local Privilege Escalation Vulnerability. This vulnerability allows local attackers to escalate privileges on affected installations of NETGEAR ProSAFE Network Management System. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.\n\nThe specific flaw exists within the product installer. The issue results from the use of default MySQL credentials. An attacker can leverage this vulnerability to escalate privileges and execute arbitrary code in the context of SYSTEM. Was ZDI-CAN-22755."
}
],
"metrics": [
{
"cvssV3_0": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
},
"format": "CVSS"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-23T22:07:01.049Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"name": "ZDI-24-496",
"tags": [
"x_research-advisory"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-24-496/"
},
{
"name": "vendor-provided URL",
"tags": [
"vendor-advisory"
],
"url": "https://kb.netgear.com/000066164/Security-Advisory-for-Multiple-Vulnerabilities-on-the-NMS300-PSV-2024-0003-PSV-2024-0004"
}
],
"source": {
"lang": "en",
"value": "191bb9f9c7b3a89d5a586e15299e24417a4aca4d"
},
"title": "NETGEAR ProSAFE Network Management System Default Credentials Local Privilege Escalation Vulnerability"
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2024-5245",
"datePublished": "2024-05-23T22:07:01.049Z",
"dateReserved": "2024-05-22T21:06:18.288Z",
"dateUpdated": "2024-08-01T21:03:11.107Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-54015 (GCVE-0-2024-54015)
Vulnerability from cvelistv5 – Published: 2025-02-11 10:28 – Updated: 2025-08-12 11:16
VLAI
Summary
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials.
Severity
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
1 reference
Impacted products
48 products
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-54015",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-11T14:31:44.397617Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-11T14:32:02.503Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD84 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MD89 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 6MU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7KE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SA87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SD87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ81 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SJ86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SK85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SL87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SS85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST85 (CP300) V9.6x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V10.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7ST86 (CP300) V9.8x",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SX85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7SY82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UM85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT82 (CP150)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT86 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7UT87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VE85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VK87 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 7VU85 (CP300)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BD-2FO",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V8.80",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BD-2FO V9.6",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.68",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Communication Module ETH-BD-2FO V9.8",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.83",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "SIPROTEC 5 Compact 7SX800 (CP050)",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V9.90",
"status": "affected",
"version": "V9.50",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions \u003c V9.90), SIPROTEC 5 6MD85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 6MD86 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 6MD89 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions \u003c V9.68), SIPROTEC 5 6MU85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7KE85 (CP300) (All versions \u003e= V8.80 \u003c V10.0), SIPROTEC 5 7SA82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SA86 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SA87 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SD82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SD86 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SD87 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SK82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SK85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SL82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SL86 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SL87 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SS85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7ST85 (CP300) (All versions \u003e= V8.80 \u003c V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions \u003c V9.68), SIPROTEC 5 7ST86 (CP300) (All versions \u003c V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions \u003c V9.83), SIPROTEC 5 7SX82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7SX85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7SY82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UM85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7UT82 (CP150) (All versions \u003c V9.90), SIPROTEC 5 7UT85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7UT86 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7UT87 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7VE85 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7VK87 (CP300) (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 7VU85 (CP300) (All versions \u003c V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions \u003c V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions \u003c V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions \u003c V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions \u003c V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions \u003c V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions \u003c V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions \u003e= V8.80 \u003c V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions \u003c V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions \u003c V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions \u003e= V9.50 \u003c V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"cvssV4_0": {
"baseScore": 8.7,
"baseSeverity": "HIGH",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-08-12T11:16:51.928Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-767615.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-54015",
"datePublished": "2025-02-11T10:28:58.684Z",
"dateReserved": "2024-11-27T09:14:02.059Z",
"dateUpdated": "2025-08-12T11:16:51.928Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-5632 (GCVE-0-2024-5632)
Vulnerability from cvelistv5 – Published: 2024-07-09 10:57 – Updated: 2024-08-01 21:18 Unsupported When Assigned
VLAI
Summary
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.
A user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged.
Severity
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
3 references
| URL | Tags |
|---|---|
| https://zamel.com/pl/gardi/zestaw-monitoringu-bez… | product |
| https://cert.pl/en/posts/2024/07/CVE-2024-5631/ | third-party-advisory |
| https://cert.pl/posts/2024/07/CVE-2024-5631/ | third-party-advisory |
Impacted products
2 products
| Vendor | Product | Version | |
|---|---|---|---|
| Longse Technology | NVR3608PGE2W |
Affected:
0 , ≤ *
(custom)
|
|
| Zamel | ZMB-01 |
Affected:
0 , ≤ *
(custom)
|
Date Public
2024-07-09 10:00
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-5632",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-07-09T13:23:30.916192Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-07-10T16:42:24.840Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T21:18:06.827Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"product",
"x_transferred"
],
"url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/"
},
{
"tags": [
"third-party-advisory",
"x_transferred"
],
"url": "https://cert.pl/posts/2024/07/CVE-2024-5631/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "affected",
"product": "NVR3608PGE2W",
"vendor": "Longse Technology",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "affected",
"product": "ZMB-01",
"vendor": "Zamel",
"versions": [
{
"lessThanOrEqual": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Adam Zambrzycki"
}
],
"datePublic": "2024-07-09T10:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Longse NVR (Network Video Recorder) model\u0026nbsp;NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.\u003cbr\u003eA user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged.\u0026nbsp;"
}
],
"value": "Longse NVR (Network Video Recorder) model\u00a0NVR3608PGE2W, as well as products based on this device, create a WiFi network with a default password.\nA user is neither advised to change it during the installation process, nor such a need is described in the manual. As the cameras from the same kit connect automatically, it is very probable for the default password to be left unchanged."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "ADJACENT",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:A/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "LOW",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392 Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-07-09T10:57:39.740Z",
"orgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"shortName": "CERT-PL"
},
"references": [
{
"tags": [
"product"
],
"url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://cert.pl/posts/2024/07/CVE-2024-5631/"
}
],
"source": {
"discovery": "UNKNOWN"
},
"tags": [
"unsupported-when-assigned"
],
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "4bb8329e-dd38-46c1-aafb-9bf32bcb93c6",
"assignerShortName": "CERT-PL",
"cveId": "CVE-2024-5632",
"datePublished": "2024-07-09T10:57:39.740Z",
"dateReserved": "2024-06-04T14:42:03.704Z",
"dateUpdated": "2024-08-01T21:18:06.827Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-6245 (GCVE-0-2024-6245)
Vulnerability from cvelistv5 – Published: 2024-10-28 16:42 – Updated: 2024-11-07 15:16
VLAI
Title
Default Credentials in ssh service for SmartPlay in Maruti Suzuki
Summary
Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.The issue was detected on a 2022 Maruti Suzuki Brezza in India Market.
This issue affects SmartPlay: 66T0.05.50.
Severity
7.4 (High)
CWE
- CWE-1392 - Use of Default Credentials
Assigner
References
2 references
| URL | Tags |
|---|---|
| https://www.marutisuzuki.com/corporate/technology… | product |
| https://www.global-infotainment-system.com/en/top.html | product |
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Faurecia Clarion Electronics Co., Ltd. | SmartPlay |
Affected:
66T0.05.50
|
Credits
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-6245",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-10-28T17:32:12.842689Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-10-28T17:32:34.956Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Infotainment Hub"
],
"platforms": [
"Linux"
],
"product": "SmartPlay",
"vendor": "Faurecia Clarion Electronics Co., Ltd.",
"versions": [
{
"status": "affected",
"version": "66T0.05.50"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Mohammed Shine"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.\u003cp\u003eThe issue was detected on a 2022 Maruti Suzuki Brezza in India Market.\u003c/p\u003e\u003cp\u003eThis issue affects SmartPlay: 66T0.05.50.\u003c/p\u003e"
}
],
"value": "Use of Default Credentials vulnerability in Maruti Suzuki SmartPlay on Linux (Infotainment Hub modules) allows attacker to try common or default usernames and passwords.The issue was detected on a 2022 Maruti Suzuki Brezza in India Market.\n\nThis issue affects SmartPlay: 66T0.05.50."
}
],
"impacts": [
{
"capecId": "CAPEC-70",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-70 Try Common or Default Usernames and Passwords"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1392",
"description": "CWE-1392: Use of Default Credentials",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-11-07T15:16:26.982Z",
"orgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
"shortName": "ASRG"
},
"references": [
{
"tags": [
"product"
],
"url": "https://www.marutisuzuki.com/corporate/technology/smartplay-systems"
},
{
"tags": [
"product"
],
"url": "https://www.global-infotainment-system.com/en/top.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Default Credentials in ssh service for SmartPlay in Maruti Suzuki",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "c15abc07-96a9-4d11-a503-5d621bfe42ba",
"assignerShortName": "ASRG",
"cveId": "CVE-2024-6245",
"datePublished": "2024-10-28T16:42:52.194Z",
"dateReserved": "2024-06-21T14:44:25.449Z",
"dateUpdated": "2024-11-07T15:16:26.982Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation
Phase: Requirements
Description:
- Prohibit use of default, hard-coded, or other values that do not vary for each installation of the product - especially for separate organizations.
Mitigation
Phase: Architecture and Design
Description:
- Force the administrator to change the credential upon installation.
Mitigation
Phases: Installation, Operation
Description:
- The product administrator could change the defaults upon installation or during operation.