CWE-120

Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')

The product copies an input buffer to an output buffer without verifying that the size of the input buffer is less than the size of the output buffer.

CVE-2022-24793 (GCVE-0-2022-24793)

Vulnerability from cvelistv5 – Published: 2022-04-06 00:00 – Updated: 2025-11-04 16:09
VLAI
Title
Potential heap buffer overflow when parsing DNS packets in PJSIP
Summary
PJSIP is a free and open source multimedia communication library written in C. A buffer overflow vulnerability in versions 2.12 and prior affects applications that use PJSIP DNS resolution. It doesn't affect PJSIP users who utilize an external resolver. This vulnerability is related to CVE-2023-27585. The difference is that this issue is in parsing the query record `parse_rr()`, while the issue in CVE-2023-27585 is in `parse_query()`. A patch is available in the `master` branch of the `pjsip/pjproject` GitHub repository. A workaround is to disable DNS resolution in PJSIP config (by setting `nameserver_count` to zero) or use an external resolver instead.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
pjsip pjproject Affected: <= 2.12
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T16:09:38.646Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/pjsip/pjproject/security/advisories/GHSA-p6g5-v97c-w5q4"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/pjsip/pjproject/commit/9fae8f43accef8ea65d4a8ae9cdf297c46cfe29a"
          },
          {
            "name": "[debian-lts-announce] 20220531 [SECURITY] [DLA 3036-1] pjproject security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/05/msg00047.html"
          },
          {
            "name": "GLSA-202210-37",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202210-37"
          },
          {
            "name": "[debian-lts-announce] 20221117 [SECURITY] [DLA 3194-1] asterisk security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/11/msg00021.html"
          },
          {
            "name": "DSA-5285",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2022/dsa-5285"
          },
          {
            "name": "[debian-lts-announce] 20230829 [SECURITY] [DLA 3549-1] ring security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2023/08/msg00038.html"
          },
          {
            "url": "https://lists.debian.org/debian-lts-announce/2024/09/msg00030.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24793",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:56:00.760122Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T18:41:25.070Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "pjproject",
          "vendor": "pjsip",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c= 2.12"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "PJSIP is a free and open source multimedia communication library written in C. A buffer overflow vulnerability in versions 2.12 and prior affects applications that use PJSIP DNS resolution. It doesn\u0027t affect PJSIP users who utilize an external resolver. This vulnerability is related to CVE-2023-27585. The difference is that this issue is in parsing the query record `parse_rr()`, while the issue in CVE-2023-27585 is in `parse_query()`. A patch is available in the `master` branch of the `pjsip/pjproject` GitHub repository. A workaround is to disable DNS resolution in PJSIP config (by setting `nameserver_count` to zero) or use an external resolver instead."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-08-30T00:06:43.947Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "url": "https://github.com/pjsip/pjproject/security/advisories/GHSA-p6g5-v97c-w5q4"
        },
        {
          "url": "https://github.com/pjsip/pjproject/commit/9fae8f43accef8ea65d4a8ae9cdf297c46cfe29a"
        },
        {
          "name": "[debian-lts-announce] 20220531 [SECURITY] [DLA 3036-1] pjproject security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/05/msg00047.html"
        },
        {
          "name": "GLSA-202210-37",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://security.gentoo.org/glsa/202210-37"
        },
        {
          "name": "[debian-lts-announce] 20221117 [SECURITY] [DLA 3194-1] asterisk security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/11/msg00021.html"
        },
        {
          "name": "DSA-5285",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5285"
        },
        {
          "name": "[debian-lts-announce] 20230829 [SECURITY] [DLA 3549-1] ring security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2023/08/msg00038.html"
        }
      ],
      "source": {
        "advisory": "GHSA-p6g5-v97c-w5q4",
        "discovery": "UNKNOWN"
      },
      "title": "Potential heap buffer overflow when parsing DNS packets in PJSIP"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-24793",
    "datePublished": "2022-04-06T00:00:00.000Z",
    "dateReserved": "2022-02-10T00:00:00.000Z",
    "dateUpdated": "2025-11-04T16:09:38.646Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2022-24805 (GCVE-0-2022-24805)

Vulnerability from cvelistv5 – Published: 2024-04-16 19:37 – Updated: 2024-08-03 04:20
VLAI
Title
net-snmp: A buffer overflow in the handling of the INDEX of NET-SNMP-VACM-MIB can cause an out-of-bounds memory access.
Summary
net-snmp provides various tools relating to the Simple Network Management Protocol. Prior to version 5.9.2, a buffer overflow in the handling of the `INDEX` of `NET-SNMP-VACM-MIB` can cause an out-of-bounds memory access. A user with read-only credentials can exploit the issue. Version 5.9.2 contains a patch. Users should use strong SNMPv3 credentials and avoid sharing the credentials. Those who must use SNMPv1 or SNMPv2c should use a complex community string and enhance the protection by restricting access to a given IP address range.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
net-snmp net-snmp Affected: 0 , < 5.9.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:net-snmp:net-snmp:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "net-snmp",
            "vendor": "net-snmp",
            "versions": [
              {
                "lessThan": "5.9.2",
                "status": "affected",
                "version": "0",
                "versionType": "semver"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24805",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T20:41:49.079548Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T17:15:56.050Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:20:50.538Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/net-snmp/net-snmp/commit/ce66eb97c17aa9a48bc079be7b65895266fa6775"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103225"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2105238"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/08/msg00020.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/FX75KKGMO5XMV6JMQZF6KOG3JPFNQBY7/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202210-29"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2022/dsa-5209"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/net-snmp/net-snmp/commit/67ebb43e9038b2dae6e74ae8838b36fcc10fc937"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "net-snmp",
          "repo": "https://github.com/net-snmp/net-snmp",
          "vendor": "net-snmp",
          "versions": [
            {
              "lessThan": "5.9.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "net-snmp provides various tools relating to the Simple Network Management Protocol. Prior to version 5.9.2, a buffer overflow in the handling of the `INDEX` of             `NET-SNMP-VACM-MIB` can cause an out-of-bounds memory access. A user with read-only credentials can exploit the issue. Version 5.9.2 contains a patch. Users should use strong SNMPv3 credentials and avoid sharing the credentials. Those who must use SNMPv1 or SNMPv2c should use a complex community string and enhance the protection by restricting access to a given IP address range.\u003cbr\u003e"
            }
          ],
          "value": "net-snmp provides various tools relating to the Simple Network Management Protocol. Prior to version 5.9.2, a buffer overflow in the handling of the `INDEX` of             `NET-SNMP-VACM-MIB` can cause an out-of-bounds memory access. A user with read-only credentials can exploit the issue. Version 5.9.2 contains a patch. Users should use strong SNMPv3 credentials and avoid sharing the credentials. Those who must use SNMPv1 or SNMPv2c should use a complex community string and enhance the protection by restricting access to a given IP address range.\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-16T19:37:40.051Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "url": "https://github.com/net-snmp/net-snmp/commit/ce66eb97c17aa9a48bc079be7b65895266fa6775"
        },
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103225"
        },
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2105238"
        },
        {
          "url": "https://lists.debian.org/debian-lts-announce/2022/08/msg00020.html"
        },
        {
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/FX75KKGMO5XMV6JMQZF6KOG3JPFNQBY7/"
        },
        {
          "url": "https://security.gentoo.org/glsa/202210-29"
        },
        {
          "url": "https://www.debian.org/security/2022/dsa-5209"
        },
        {
          "url": "https://github.com/net-snmp/net-snmp/commit/67ebb43e9038b2dae6e74ae8838b36fcc10fc937"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "net-snmp: A buffer overflow in the handling of the INDEX of NET-SNMP-VACM-MIB can cause an out-of-bounds memory access.",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-24805",
    "datePublished": "2024-04-16T19:37:40.051Z",
    "dateReserved": "2022-02-10T16:41:34.916Z",
    "dateUpdated": "2024-08-03T04:20:50.538Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24807 (GCVE-0-2022-24807)

Vulnerability from cvelistv5 – Published: 2024-04-16 19:49 – Updated: 2024-08-03 04:20
VLAI
Title
net-snmp: A malformed OID in a SET request to SNMP-VIEW-BASED-ACM-MIB::vacmAccessTable can cause an out-of-bounds memory access
Summary
net-snmp provides various tools relating to the Simple Network Management Protocol. Prior to version 5.9.2, a malformed OID in a SET request to `SNMP-VIEW-BASED-ACM-MIB::vacmAccessTable` can cause an out-of-bounds memory access. A user with read-write credentials can exploit the issue. Version 5.9.2 contains a patch. Users should use strong SNMPv3 credentials and avoid sharing the credentials. Those who must use SNMPv1 or SNMPv2c should use a complex community string and enhance the protection by restricting access to a given IP address range.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
net-snmp net-snmp Affected: 0 , < 5.9.2 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24807",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-23T20:44:00.621550Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T18:51:55.237Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:20:50.465Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/net-snmp/net-snmp/commit/ce66eb97c17aa9a48bc079be7b65895266fa6775"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103225"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2105239"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/08/msg00020.html"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/FX75KKGMO5XMV6JMQZF6KOG3JPFNQBY7/"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.gentoo.org/glsa/202210-29"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2022/dsa-5209"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/net-snmp/net-snmp/commit/67ebb43e9038b2dae6e74ae8838b36fcc10fc937"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "net-snmp",
          "repo": "https://github.com/net-snmp/net-snmp",
          "vendor": "net-snmp",
          "versions": [
            {
              "lessThan": "5.9.2",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "net-snmp provides various tools relating to the Simple Network Management Protocol. Prior to version 5.9.2, a malformed OID in a SET request to `SNMP-VIEW-BASED-ACM-MIB::vacmAccessTable` can cause an out-of-bounds memory access. A user with read-write credentials can exploit the issue. Version 5.9.2 contains a patch. Users should use strong SNMPv3 credentials and avoid sharing the credentials. Those who must use SNMPv1 or SNMPv2c should use a complex community string and enhance the protection by restricting access to a given IP address range.\u003cbr\u003e"
            }
          ],
          "value": "net-snmp provides various tools relating to the Simple Network Management Protocol. Prior to version 5.9.2, a malformed OID in a SET request to `SNMP-VIEW-BASED-ACM-MIB::vacmAccessTable` can cause an out-of-bounds memory access. A user with read-write credentials can exploit the issue. Version 5.9.2 contains a patch. Users should use strong SNMPv3 credentials and avoid sharing the credentials. Those who must use SNMPv1 or SNMPv2c should use a complex community string and enhance the protection by restricting access to a given IP address range.\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-16T19:49:00.448Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "url": "https://github.com/net-snmp/net-snmp/commit/ce66eb97c17aa9a48bc079be7b65895266fa6775"
        },
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2103225"
        },
        {
          "url": "https://bugzilla.redhat.com/show_bug.cgi?id=2105239"
        },
        {
          "url": "https://lists.debian.org/debian-lts-announce/2022/08/msg00020.html"
        },
        {
          "url": "https://lists.fedoraproject.org/archives/list/package-announce@lists.fedoraproject.org/message/FX75KKGMO5XMV6JMQZF6KOG3JPFNQBY7/"
        },
        {
          "url": "https://security.gentoo.org/glsa/202210-29"
        },
        {
          "url": "https://www.debian.org/security/2022/dsa-5209"
        },
        {
          "url": "https://github.com/net-snmp/net-snmp/commit/67ebb43e9038b2dae6e74ae8838b36fcc10fc937"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "net-snmp: A malformed OID in a SET request to SNMP-VIEW-BASED-ACM-MIB::vacmAccessTable can cause an out-of-bounds memory access",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-24807",
    "datePublished": "2024-04-16T19:49:00.448Z",
    "dateReserved": "2022-02-10T16:41:34.917Z",
    "dateUpdated": "2024-08-03T04:20:50.465Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24903 (GCVE-0-2022-24903)

Vulnerability from cvelistv5 – Published: 2022-05-05 00:00 – Updated: 2025-04-23 18:31
VLAI
Title
Buffer overflow in TCP syslog server (receiver) components in rsyslog
Summary
Rsyslog is a rocket-fast system for log processing. Modules for TCP syslog reception have a potential heap buffer overflow when octet-counted framing is used. This can result in a segfault or some other malfunction. As of our understanding, this vulnerability can not be used for remote code execution. But there may still be a slight chance for experts to do that. The bug occurs when the octet count is read. While there is a check for the maximum number of octets, digits are written to a heap buffer even when the octet count is over the maximum, This can be used to overrun the memory buffer. However, once the sequence of digits stop, no additional characters can be added to the buffer. In our opinion, this makes remote exploits impossible or at least highly complex. Octet-counted framing is one of two potential framing modes. It is relatively uncommon, but enabled by default on receivers. Modules `imtcp`, `imptcp`, `imgssapi`, and `imhttp` are used for regular syslog message reception. It is best practice not to directly expose them to the public. When this practice is followed, the risk is considerably lower. Module `imdiag` is a diagnostics module primarily intended for testbench runs. We do not expect it to be present on any production installation. Octet-counted framing is not very common. Usually, it needs to be specifically enabled at senders. If users do not need it, they can turn it off for the most important modules. This will mitigate the vulnerability.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
rsyslog rsyslog Affected: < 8.2204.1
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:29:01.617Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/rsyslog/rsyslog/security/advisories/GHSA-ggw7-xr6h-mmr8"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/rsyslog/rsyslog/commit/f211042ecbb472f9d8beb4678a65d272b6f07705"
          },
          {
            "name": "FEDORA-2022-f796a28a7b",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GMNNXLCU2UORRVSZO24HL4KMVPK5PHVW/"
          },
          {
            "name": "[debian-lts-announce] 20220520 [SECURITY] [DLA 3016-1] rsyslog security update",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "https://lists.debian.org/debian-lts-announce/2022/05/msg00028.html"
          },
          {
            "name": "DSA-5150",
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.debian.org/security/2022/dsa-5150"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://security.netapp.com/advisory/ntap-20221111-0002/"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24903",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-23T15:53:40.144468Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-23T18:31:22.233Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "rsyslog",
          "vendor": "rsyslog",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 8.2204.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Rsyslog is a rocket-fast system for log processing. Modules for TCP syslog reception have a potential heap buffer overflow when octet-counted framing is used. This can result in a segfault or some other malfunction. As of our understanding, this vulnerability can not be used for remote code execution. But there may still be a slight chance for experts to do that. The bug occurs when the octet count is read. While there is a check for the maximum number of octets, digits are written to a heap buffer even when the octet count is over the maximum, This can be used to overrun the memory buffer. However, once the sequence of digits stop, no additional characters can be added to the buffer. In our opinion, this makes remote exploits impossible or at least highly complex. Octet-counted framing is one of two potential framing modes. It is relatively uncommon, but enabled by default on receivers. Modules `imtcp`, `imptcp`, `imgssapi`, and `imhttp` are used for regular syslog message reception. It is best practice not to directly expose them to the public. When this practice is followed, the risk is considerably lower. Module `imdiag` is a diagnostics module primarily intended for testbench runs. We do not expect it to be present on any production installation. Octet-counted framing is not very common. Usually, it needs to be specifically enabled at senders. If users do not need it, they can turn it off for the most important modules. This will mitigate the vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-11-14T00:00:00.000Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "url": "https://github.com/rsyslog/rsyslog/security/advisories/GHSA-ggw7-xr6h-mmr8"
        },
        {
          "url": "https://github.com/rsyslog/rsyslog/commit/f211042ecbb472f9d8beb4678a65d272b6f07705"
        },
        {
          "name": "FEDORA-2022-f796a28a7b",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://lists.fedoraproject.org/archives/list/package-announce%40lists.fedoraproject.org/message/GMNNXLCU2UORRVSZO24HL4KMVPK5PHVW/"
        },
        {
          "name": "[debian-lts-announce] 20220520 [SECURITY] [DLA 3016-1] rsyslog security update",
          "tags": [
            "mailing-list"
          ],
          "url": "https://lists.debian.org/debian-lts-announce/2022/05/msg00028.html"
        },
        {
          "name": "DSA-5150",
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.debian.org/security/2022/dsa-5150"
        },
        {
          "url": "https://security.netapp.com/advisory/ntap-20221111-0002/"
        }
      ],
      "source": {
        "advisory": "GHSA-ggw7-xr6h-mmr8",
        "discovery": "UNKNOWN"
      },
      "title": "Buffer overflow in TCP syslog server (receiver) components in rsyslog"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2022-24903",
    "datePublished": "2022-05-05T00:00:00.000Z",
    "dateReserved": "2022-02-10T00:00:00.000Z",
    "dateUpdated": "2025-04-23T18:31:22.233Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-24910 (GCVE-0-2022-24910)

Vulnerability from cvelistv5 – Published: 2022-05-12 17:01 – Updated: 2025-04-15 19:03
VLAI
Summary
A buffer overflow vulnerability exists in the httpd parse_ping_result API functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted file can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
Date Public
2022-05-10 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:29:00.639Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1471"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-24910",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-15T18:23:05.948599Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-15T19:03:26.619Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "InRouter302",
          "vendor": "InHand Networks",
          "versions": [
            {
              "status": "affected",
              "version": "V3.5.4"
            }
          ]
        }
      ],
      "datePublic": "2022-05-10T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A buffer overflow vulnerability exists in the httpd parse_ping_result API functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted file can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.2,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-05-12T17:01:33.000Z",
        "orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
        "shortName": "talos"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1471"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "talos-cna@cisco.com",
          "DATE_PUBLIC": "2022-05-10",
          "ID": "CVE-2022-24910",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "InRouter302",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "V3.5.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "InHand Networks"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A buffer overflow vulnerability exists in the httpd parse_ping_result API functionality of InHand Networks InRouter302 V3.5.4. A specially-crafted file can lead to remote code execution. An attacker can send a sequence of requests to trigger this vulnerability."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 8.2,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf",
              "refsource": "CONFIRM",
              "url": "https://www.inhandnetworks.com/upload/attachment/202205/10/InHand-PSA-2022-01.pdf"
            },
            {
              "name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1471",
              "refsource": "MISC",
              "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1471"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
    "assignerShortName": "talos",
    "cveId": "CVE-2022-24910",
    "datePublished": "2022-05-12T17:01:33.206Z",
    "dateReserved": "2022-02-22T00:00:00.000Z",
    "dateUpdated": "2025-04-15T19:03:26.619Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25635 (GCVE-0-2022-25635)

Vulnerability from cvelistv5 – Published: 2022-08-30 04:25 – Updated: 2024-09-16 16:44
VLAI
Title
Realtek Linux/Android Bluetooth Mesh SDK - Buffer Overflow
Summary
Realtek Linux/Android Bluetooth Mesh SDK has a buffer overflow vulnerability due to insufficient validation for broadcast network packet length. An unauthenticated attacker in the adjacent network can exploit this vulnerability to disrupt service.
CWE
Assigner
References
Impacted products
Vendor Product Version
Realtek Linux/Android Bluetooth Mesh SDK Affected: unspecified , ≤ 4.17-4.17-20220127 (custom)
Create a notification for this product.
Date Public
2022-08-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.311Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.twcert.org.tw/tw/cp-132-6456-fc6c5-1.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Linux/Android Bluetooth Mesh SDK",
          "vendor": "Realtek",
          "versions": [
            {
              "lessThanOrEqual": "4.17-4.17-20220127",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-08-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Realtek Linux/Android Bluetooth Mesh SDK has a buffer overflow vulnerability due to insufficient validation for broadcast network packet length. An unauthenticated attacker in the adjacent network can exploit this vulnerability to disrupt service."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-08-30T04:25:23.000Z",
        "orgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
        "shortName": "twcert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.twcert.org.tw/tw/cp-132-6456-fc6c5-1.html"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Realtek Linux/Android Bluetooth Mesh SDK v4.18-4.18-20220218"
        }
      ],
      "source": {
        "advisory": "TVN-202205001",
        "discovery": "EXTERNAL"
      },
      "title": "Realtek Linux/Android Bluetooth Mesh SDK - Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "AKA": "TWCERT/CC",
          "ASSIGNER": "cve@cert.org.tw",
          "DATE_PUBLIC": "2022-08-30T03:58:00.000Z",
          "ID": "CVE-2022-25635",
          "STATE": "PUBLIC",
          "TITLE": "Realtek Linux/Android Bluetooth Mesh SDK - Buffer Overflow"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Linux/Android Bluetooth Mesh SDK",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_value": "4.17-4.17-20220127"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Realtek"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Realtek Linux/Android Bluetooth Mesh SDK has a buffer overflow vulnerability due to insufficient validation for broadcast network packet length. An unauthenticated attacker in the adjacent network can exploit this vulnerability to disrupt service."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120 Buffer Overflow"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.twcert.org.tw/tw/cp-132-6456-fc6c5-1.html",
              "refsource": "MISC",
              "url": "https://www.twcert.org.tw/tw/cp-132-6456-fc6c5-1.html"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Realtek Linux/Android Bluetooth Mesh SDK v4.18-4.18-20220218"
          }
        ],
        "source": {
          "advisory": "TVN-202205001",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cded6c7f-6ce5-4948-8f87-aa7a3bbb6b0e",
    "assignerShortName": "twcert",
    "cveId": "CVE-2022-25635",
    "datePublished": "2022-08-30T04:25:24.051Z",
    "dateReserved": "2022-02-22T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:44:07.179Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25655 (GCVE-0-2022-25655)

Vulnerability from cvelistv5 – Published: 2023-03-07 04:43 – Updated: 2024-08-03 04:42
VLAI
Title
Buffer copy without checking the size of input in WLAN HAL.
Summary
Memory corruption in WLAN HAL while arbitrary value is passed in WMI UTF command payload.
CWE
  • CWE-120 - Buffer Copy Without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Qualcomm, Inc. Snapdragon Affected: APQ8009
Affected: APQ8017
Affected: APQ8076
Affected: APQ8084
Affected: APQ8092
Affected: APQ8094
Affected: APQ8096AU
Affected: AQT1000
Affected: AR8031
Affected: AR9380
Affected: CSR8811
Affected: CSRA6620
Affected: CSRA6640
Affected: CSRB31024
Affected: IPQ4018
Affected: IPQ4019
Affected: IPQ4028
Affected: IPQ4029
Affected: IPQ5010
Affected: IPQ5018
Affected: IPQ5028
Affected: IPQ6000
Affected: IPQ6005
Affected: IPQ6010
Affected: IPQ6018
Affected: IPQ6028
Affected: IPQ8064
Affected: IPQ8065
Affected: IPQ8068
Affected: IPQ8069
Affected: IPQ8070
Affected: IPQ8070A
Affected: IPQ8071
Affected: IPQ8071A
Affected: IPQ8072
Affected: IPQ8072A
Affected: IPQ8074
Affected: IPQ8074A
Affected: IPQ8076
Affected: IPQ8076A
Affected: IPQ8078
Affected: IPQ8078A
Affected: IPQ8173
Affected: IPQ8174
Affected: MDM8215
Affected: MDM9206
Affected: MDM9215
Affected: MDM9235M
Affected: MDM9250
Affected: MDM9310
Affected: MDM9330
Affected: MDM9607
Affected: MDM9615
Affected: MDM9628
Affected: MDM9635M
Affected: MDM9640
Affected: MDM9650
Affected: MSM8976
Affected: MSM8992
Affected: MSM8994
Affected: MSM8996AU
Affected: QCA1990
Affected: QCA4010
Affected: QCA4020
Affected: QCA4024
Affected: QCA6164
Affected: QCA6174
Affected: QCA6174A
Affected: QCA6175A
Affected: QCA6310
Affected: QCA6320
Affected: QCA6335
Affected: QCA6390
Affected: QCA6391
Affected: QCA6420
Affected: QCA6428
Affected: QCA6430
Affected: QCA6438
Affected: QCA6554A
Affected: QCA6564
Affected: QCA6564A
Affected: QCA6564AU
Affected: QCA6574
Affected: QCA6574A
Affected: QCA6574AU
Affected: QCA6584
Affected: QCA6584AU
Affected: QCA6595
Affected: QCA6595AU
Affected: QCA6696
Affected: QCA7500
Affected: QCA8075
Affected: QCA8081
Affected: QCA9367
Affected: QCA9377
Affected: QCA9379
Affected: QCA9531
Affected: QCA9558
Affected: QCA9561
Affected: QCA9880
Affected: QCA9882
Affected: QCA9886
Affected: QCA9887
Affected: QCA9888
Affected: QCA9889
Affected: QCA9898
Affected: QCA9980
Affected: QCA9982
Affected: QCA9984
Affected: QCA9985
Affected: QCA9986
Affected: QCA9987
Affected: QCA9990
Affected: QCA9992
Affected: QCA9994
Affected: QCC5100
Affected: QCM2290
Affected: QCM4290
Affected: QCM4325
Affected: QCM6125
Affected: QCN5021
Affected: QCN5022
Affected: QCN5024
Affected: QCN5052
Affected: QCN5054
Affected: QCN5064
Affected: QCN5121
Affected: QCN5122
Affected: QCN5124
Affected: QCN5152
Affected: QCN5154
Affected: QCN5164
Affected: QCN5550
Affected: QCN6023
Affected: QCN6024
Affected: QCN6122
Affected: QCN6132
Affected: QCN9000
Affected: QCN9012
Affected: QCN9022
Affected: QCN9024
Affected: QCN9070
Affected: QCN9072
Affected: QCN9074
Affected: QCN9100
Affected: QCS2290
Affected: QCS405
Affected: QCS410
Affected: QCS4290
Affected: QCS603
Affected: QCS605
Affected: QCS610
Affected: QCS6125
Affected: QFE1922
Affected: QFE1952
Affected: SA415M
Affected: SA515M
Affected: SA6145P
Affected: SA6150P
Affected: SA6155
Affected: SA6155P
Affected: SA8145P
Affected: SA8150P
Affected: SA8155
Affected: SA8155P
Affected: SA8195P
Affected: SC8180X+SDX55
Affected: SD 455
Affected: SD 636
Affected: SD 675
Affected: SD 8CX
Affected: SD 8cx Gen2
Affected: SD460
Affected: SD480
Affected: SD660
Affected: SD662
Affected: SD665
Affected: SD670
Affected: SD675
Affected: SD678
Affected: SD680
Affected: SD690 5G
Affected: SD695
Affected: SD710
Affected: SD712
Affected: SD720G
Affected: SD730
Affected: SD750G
Affected: SD765
Affected: SD765G
Affected: SD768G
Affected: SD7c
Affected: SD820
Affected: SD835
Affected: SD845
Affected: SD850
Affected: SD855
Affected: SDM630
Affected: SDX20M
Affected: SDX50M
Affected: SDX55
Affected: SDX55M
Affected: SDXR1
Affected: SG4150P
Affected: SM4125
Affected: SM6250
Affected: SM6250P
Affected: SM7250P
Affected: Snapdragon 4 Gen 1
Affected: SW5100
Affected: SW5100P
Affected: WCD9326
Affected: WCD9330
Affected: WCD9335
Affected: WCD9340
Affected: WCD9341
Affected: WCD9360
Affected: WCD9370
Affected: WCD9371
Affected: WCD9375
Affected: WCD9380
Affected: WCD9385
Affected: WCN3610
Affected: WCN3615
Affected: WCN3660B
Affected: WCN3680B
Affected: WCN3910
Affected: WCN3950
Affected: WCN3980
Affected: WCN3988
Affected: WCN3990
Affected: WCN3991
Affected: WCN3998
Affected: WCN3999
Affected: WSA8810
Affected: WSA8815
Affected: WSA8830
Affected: WSA8835
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.588Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.qualcomm.com/company/product-security/bulletins/march-2023-bulletin"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Auto",
            "Snapdragon Compute",
            "Snapdragon Connectivity",
            "Snapdragon Consumer Electronics Connectivity",
            "Snapdragon Consumer IOT",
            "Snapdragon Industrial IOT",
            "Snapdragon Mobile",
            "Snapdragon Voice \u0026 Music",
            "Snapdragon Wearables",
            "Snapdragon Wired Infrastructure and Networking"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "APQ8009"
            },
            {
              "status": "affected",
              "version": "APQ8017"
            },
            {
              "status": "affected",
              "version": "APQ8076"
            },
            {
              "status": "affected",
              "version": "APQ8084"
            },
            {
              "status": "affected",
              "version": "APQ8092"
            },
            {
              "status": "affected",
              "version": "APQ8094"
            },
            {
              "status": "affected",
              "version": "APQ8096AU"
            },
            {
              "status": "affected",
              "version": "AQT1000"
            },
            {
              "status": "affected",
              "version": "AR8031"
            },
            {
              "status": "affected",
              "version": "AR9380"
            },
            {
              "status": "affected",
              "version": "CSR8811"
            },
            {
              "status": "affected",
              "version": "CSRA6620"
            },
            {
              "status": "affected",
              "version": "CSRA6640"
            },
            {
              "status": "affected",
              "version": "CSRB31024"
            },
            {
              "status": "affected",
              "version": "IPQ4018"
            },
            {
              "status": "affected",
              "version": "IPQ4019"
            },
            {
              "status": "affected",
              "version": "IPQ4028"
            },
            {
              "status": "affected",
              "version": "IPQ4029"
            },
            {
              "status": "affected",
              "version": "IPQ5010"
            },
            {
              "status": "affected",
              "version": "IPQ5018"
            },
            {
              "status": "affected",
              "version": "IPQ5028"
            },
            {
              "status": "affected",
              "version": "IPQ6000"
            },
            {
              "status": "affected",
              "version": "IPQ6005"
            },
            {
              "status": "affected",
              "version": "IPQ6010"
            },
            {
              "status": "affected",
              "version": "IPQ6018"
            },
            {
              "status": "affected",
              "version": "IPQ6028"
            },
            {
              "status": "affected",
              "version": "IPQ8064"
            },
            {
              "status": "affected",
              "version": "IPQ8065"
            },
            {
              "status": "affected",
              "version": "IPQ8068"
            },
            {
              "status": "affected",
              "version": "IPQ8069"
            },
            {
              "status": "affected",
              "version": "IPQ8070"
            },
            {
              "status": "affected",
              "version": "IPQ8070A"
            },
            {
              "status": "affected",
              "version": "IPQ8071"
            },
            {
              "status": "affected",
              "version": "IPQ8071A"
            },
            {
              "status": "affected",
              "version": "IPQ8072"
            },
            {
              "status": "affected",
              "version": "IPQ8072A"
            },
            {
              "status": "affected",
              "version": "IPQ8074"
            },
            {
              "status": "affected",
              "version": "IPQ8074A"
            },
            {
              "status": "affected",
              "version": "IPQ8076"
            },
            {
              "status": "affected",
              "version": "IPQ8076A"
            },
            {
              "status": "affected",
              "version": "IPQ8078"
            },
            {
              "status": "affected",
              "version": "IPQ8078A"
            },
            {
              "status": "affected",
              "version": "IPQ8173"
            },
            {
              "status": "affected",
              "version": "IPQ8174"
            },
            {
              "status": "affected",
              "version": "MDM8215"
            },
            {
              "status": "affected",
              "version": "MDM9206"
            },
            {
              "status": "affected",
              "version": "MDM9215"
            },
            {
              "status": "affected",
              "version": "MDM9235M"
            },
            {
              "status": "affected",
              "version": "MDM9250"
            },
            {
              "status": "affected",
              "version": "MDM9310"
            },
            {
              "status": "affected",
              "version": "MDM9330"
            },
            {
              "status": "affected",
              "version": "MDM9607"
            },
            {
              "status": "affected",
              "version": "MDM9615"
            },
            {
              "status": "affected",
              "version": "MDM9628"
            },
            {
              "status": "affected",
              "version": "MDM9635M"
            },
            {
              "status": "affected",
              "version": "MDM9640"
            },
            {
              "status": "affected",
              "version": "MDM9650"
            },
            {
              "status": "affected",
              "version": "MSM8976"
            },
            {
              "status": "affected",
              "version": "MSM8992"
            },
            {
              "status": "affected",
              "version": "MSM8994"
            },
            {
              "status": "affected",
              "version": "MSM8996AU"
            },
            {
              "status": "affected",
              "version": "QCA1990"
            },
            {
              "status": "affected",
              "version": "QCA4010"
            },
            {
              "status": "affected",
              "version": "QCA4020"
            },
            {
              "status": "affected",
              "version": "QCA4024"
            },
            {
              "status": "affected",
              "version": "QCA6164"
            },
            {
              "status": "affected",
              "version": "QCA6174"
            },
            {
              "status": "affected",
              "version": "QCA6174A"
            },
            {
              "status": "affected",
              "version": "QCA6175A"
            },
            {
              "status": "affected",
              "version": "QCA6310"
            },
            {
              "status": "affected",
              "version": "QCA6320"
            },
            {
              "status": "affected",
              "version": "QCA6335"
            },
            {
              "status": "affected",
              "version": "QCA6390"
            },
            {
              "status": "affected",
              "version": "QCA6391"
            },
            {
              "status": "affected",
              "version": "QCA6420"
            },
            {
              "status": "affected",
              "version": "QCA6428"
            },
            {
              "status": "affected",
              "version": "QCA6430"
            },
            {
              "status": "affected",
              "version": "QCA6438"
            },
            {
              "status": "affected",
              "version": "QCA6554A"
            },
            {
              "status": "affected",
              "version": "QCA6564"
            },
            {
              "status": "affected",
              "version": "QCA6564A"
            },
            {
              "status": "affected",
              "version": "QCA6564AU"
            },
            {
              "status": "affected",
              "version": "QCA6574"
            },
            {
              "status": "affected",
              "version": "QCA6574A"
            },
            {
              "status": "affected",
              "version": "QCA6574AU"
            },
            {
              "status": "affected",
              "version": "QCA6584"
            },
            {
              "status": "affected",
              "version": "QCA6584AU"
            },
            {
              "status": "affected",
              "version": "QCA6595"
            },
            {
              "status": "affected",
              "version": "QCA6595AU"
            },
            {
              "status": "affected",
              "version": "QCA6696"
            },
            {
              "status": "affected",
              "version": "QCA7500"
            },
            {
              "status": "affected",
              "version": "QCA8075"
            },
            {
              "status": "affected",
              "version": "QCA8081"
            },
            {
              "status": "affected",
              "version": "QCA9367"
            },
            {
              "status": "affected",
              "version": "QCA9377"
            },
            {
              "status": "affected",
              "version": "QCA9379"
            },
            {
              "status": "affected",
              "version": "QCA9531"
            },
            {
              "status": "affected",
              "version": "QCA9558"
            },
            {
              "status": "affected",
              "version": "QCA9561"
            },
            {
              "status": "affected",
              "version": "QCA9880"
            },
            {
              "status": "affected",
              "version": "QCA9882"
            },
            {
              "status": "affected",
              "version": "QCA9886"
            },
            {
              "status": "affected",
              "version": "QCA9887"
            },
            {
              "status": "affected",
              "version": "QCA9888"
            },
            {
              "status": "affected",
              "version": "QCA9889"
            },
            {
              "status": "affected",
              "version": "QCA9898"
            },
            {
              "status": "affected",
              "version": "QCA9980"
            },
            {
              "status": "affected",
              "version": "QCA9982"
            },
            {
              "status": "affected",
              "version": "QCA9984"
            },
            {
              "status": "affected",
              "version": "QCA9985"
            },
            {
              "status": "affected",
              "version": "QCA9986"
            },
            {
              "status": "affected",
              "version": "QCA9987"
            },
            {
              "status": "affected",
              "version": "QCA9990"
            },
            {
              "status": "affected",
              "version": "QCA9992"
            },
            {
              "status": "affected",
              "version": "QCA9994"
            },
            {
              "status": "affected",
              "version": "QCC5100"
            },
            {
              "status": "affected",
              "version": "QCM2290"
            },
            {
              "status": "affected",
              "version": "QCM4290"
            },
            {
              "status": "affected",
              "version": "QCM4325"
            },
            {
              "status": "affected",
              "version": "QCM6125"
            },
            {
              "status": "affected",
              "version": "QCN5021"
            },
            {
              "status": "affected",
              "version": "QCN5022"
            },
            {
              "status": "affected",
              "version": "QCN5024"
            },
            {
              "status": "affected",
              "version": "QCN5052"
            },
            {
              "status": "affected",
              "version": "QCN5054"
            },
            {
              "status": "affected",
              "version": "QCN5064"
            },
            {
              "status": "affected",
              "version": "QCN5121"
            },
            {
              "status": "affected",
              "version": "QCN5122"
            },
            {
              "status": "affected",
              "version": "QCN5124"
            },
            {
              "status": "affected",
              "version": "QCN5152"
            },
            {
              "status": "affected",
              "version": "QCN5154"
            },
            {
              "status": "affected",
              "version": "QCN5164"
            },
            {
              "status": "affected",
              "version": "QCN5550"
            },
            {
              "status": "affected",
              "version": "QCN6023"
            },
            {
              "status": "affected",
              "version": "QCN6024"
            },
            {
              "status": "affected",
              "version": "QCN6122"
            },
            {
              "status": "affected",
              "version": "QCN6132"
            },
            {
              "status": "affected",
              "version": "QCN9000"
            },
            {
              "status": "affected",
              "version": "QCN9012"
            },
            {
              "status": "affected",
              "version": "QCN9022"
            },
            {
              "status": "affected",
              "version": "QCN9024"
            },
            {
              "status": "affected",
              "version": "QCN9070"
            },
            {
              "status": "affected",
              "version": "QCN9072"
            },
            {
              "status": "affected",
              "version": "QCN9074"
            },
            {
              "status": "affected",
              "version": "QCN9100"
            },
            {
              "status": "affected",
              "version": "QCS2290"
            },
            {
              "status": "affected",
              "version": "QCS405"
            },
            {
              "status": "affected",
              "version": "QCS410"
            },
            {
              "status": "affected",
              "version": "QCS4290"
            },
            {
              "status": "affected",
              "version": "QCS603"
            },
            {
              "status": "affected",
              "version": "QCS605"
            },
            {
              "status": "affected",
              "version": "QCS610"
            },
            {
              "status": "affected",
              "version": "QCS6125"
            },
            {
              "status": "affected",
              "version": "QFE1922"
            },
            {
              "status": "affected",
              "version": "QFE1952"
            },
            {
              "status": "affected",
              "version": "SA415M"
            },
            {
              "status": "affected",
              "version": "SA515M"
            },
            {
              "status": "affected",
              "version": "SA6145P"
            },
            {
              "status": "affected",
              "version": "SA6150P"
            },
            {
              "status": "affected",
              "version": "SA6155"
            },
            {
              "status": "affected",
              "version": "SA6155P"
            },
            {
              "status": "affected",
              "version": "SA8145P"
            },
            {
              "status": "affected",
              "version": "SA8150P"
            },
            {
              "status": "affected",
              "version": "SA8155"
            },
            {
              "status": "affected",
              "version": "SA8155P"
            },
            {
              "status": "affected",
              "version": "SA8195P"
            },
            {
              "status": "affected",
              "version": "SC8180X+SDX55"
            },
            {
              "status": "affected",
              "version": "SD 455"
            },
            {
              "status": "affected",
              "version": "SD 636"
            },
            {
              "status": "affected",
              "version": "SD 675"
            },
            {
              "status": "affected",
              "version": "SD 8CX"
            },
            {
              "status": "affected",
              "version": "SD 8cx Gen2"
            },
            {
              "status": "affected",
              "version": "SD460"
            },
            {
              "status": "affected",
              "version": "SD480"
            },
            {
              "status": "affected",
              "version": "SD660"
            },
            {
              "status": "affected",
              "version": "SD662"
            },
            {
              "status": "affected",
              "version": "SD665"
            },
            {
              "status": "affected",
              "version": "SD670"
            },
            {
              "status": "affected",
              "version": "SD675"
            },
            {
              "status": "affected",
              "version": "SD678"
            },
            {
              "status": "affected",
              "version": "SD680"
            },
            {
              "status": "affected",
              "version": "SD690 5G"
            },
            {
              "status": "affected",
              "version": "SD695"
            },
            {
              "status": "affected",
              "version": "SD710"
            },
            {
              "status": "affected",
              "version": "SD712"
            },
            {
              "status": "affected",
              "version": "SD720G"
            },
            {
              "status": "affected",
              "version": "SD730"
            },
            {
              "status": "affected",
              "version": "SD750G"
            },
            {
              "status": "affected",
              "version": "SD765"
            },
            {
              "status": "affected",
              "version": "SD765G"
            },
            {
              "status": "affected",
              "version": "SD768G"
            },
            {
              "status": "affected",
              "version": "SD7c"
            },
            {
              "status": "affected",
              "version": "SD820"
            },
            {
              "status": "affected",
              "version": "SD835"
            },
            {
              "status": "affected",
              "version": "SD845"
            },
            {
              "status": "affected",
              "version": "SD850"
            },
            {
              "status": "affected",
              "version": "SD855"
            },
            {
              "status": "affected",
              "version": "SDM630"
            },
            {
              "status": "affected",
              "version": "SDX20M"
            },
            {
              "status": "affected",
              "version": "SDX50M"
            },
            {
              "status": "affected",
              "version": "SDX55"
            },
            {
              "status": "affected",
              "version": "SDX55M"
            },
            {
              "status": "affected",
              "version": "SDXR1"
            },
            {
              "status": "affected",
              "version": "SG4150P"
            },
            {
              "status": "affected",
              "version": "SM4125"
            },
            {
              "status": "affected",
              "version": "SM6250"
            },
            {
              "status": "affected",
              "version": "SM6250P"
            },
            {
              "status": "affected",
              "version": "SM7250P"
            },
            {
              "status": "affected",
              "version": "Snapdragon 4 Gen 1"
            },
            {
              "status": "affected",
              "version": "SW5100"
            },
            {
              "status": "affected",
              "version": "SW5100P"
            },
            {
              "status": "affected",
              "version": "WCD9326"
            },
            {
              "status": "affected",
              "version": "WCD9330"
            },
            {
              "status": "affected",
              "version": "WCD9335"
            },
            {
              "status": "affected",
              "version": "WCD9340"
            },
            {
              "status": "affected",
              "version": "WCD9341"
            },
            {
              "status": "affected",
              "version": "WCD9360"
            },
            {
              "status": "affected",
              "version": "WCD9370"
            },
            {
              "status": "affected",
              "version": "WCD9371"
            },
            {
              "status": "affected",
              "version": "WCD9375"
            },
            {
              "status": "affected",
              "version": "WCD9380"
            },
            {
              "status": "affected",
              "version": "WCD9385"
            },
            {
              "status": "affected",
              "version": "WCN3610"
            },
            {
              "status": "affected",
              "version": "WCN3615"
            },
            {
              "status": "affected",
              "version": "WCN3660B"
            },
            {
              "status": "affected",
              "version": "WCN3680B"
            },
            {
              "status": "affected",
              "version": "WCN3910"
            },
            {
              "status": "affected",
              "version": "WCN3950"
            },
            {
              "status": "affected",
              "version": "WCN3980"
            },
            {
              "status": "affected",
              "version": "WCN3988"
            },
            {
              "status": "affected",
              "version": "WCN3990"
            },
            {
              "status": "affected",
              "version": "WCN3991"
            },
            {
              "status": "affected",
              "version": "WCN3998"
            },
            {
              "status": "affected",
              "version": "WCN3999"
            },
            {
              "status": "affected",
              "version": "WSA8810"
            },
            {
              "status": "affected",
              "version": "WSA8815"
            },
            {
              "status": "affected",
              "version": "WSA8830"
            },
            {
              "status": "affected",
              "version": "WSA8835"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Memory corruption in WLAN HAL while arbitrary value is passed in WMI UTF command payload."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy Without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-12T16:30:06.860Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://www.qualcomm.com/company/product-security/bulletins/march-2023-bulletin"
        }
      ],
      "title": "Buffer copy without checking the size of input in WLAN HAL."
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2022-25655",
    "datePublished": "2023-03-07T04:43:15.195Z",
    "dateReserved": "2022-02-22T11:38:09.279Z",
    "dateUpdated": "2024-08-03T04:42:50.588Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25678 (GCVE-0-2022-25678)

Vulnerability from cvelistv5 – Published: 2023-04-04 04:46 – Updated: 2024-08-03 04:42
VLAI
Title
Buffer Copy Without Checking Size of Input in MODEM
Summary
Memory correction in modem due to buffer overwrite during coap connection
CWE
  • CWE-120 - Buffer Copy Without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Qualcomm, Inc. Snapdragon Affected: 9205 LTE Modem
Affected: 9206 LTE Modem
Affected: 9207 LTE Modem
Affected: MDM8207
Affected: QCA4004
Affected: QTS110
Affected: Snapdragon 1100 Wearable Platform
Affected: Snapdragon 1200 Wearable Platform
Affected: Snapdragon Wear 1300 Platform
Affected: Snapdragon X5 LTE Modem
Affected: WCD9306
Affected: WCD9330
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-25678",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-05T16:30:49.822230Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-05T16:31:06.545Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:42:50.661Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.qualcomm.com/company/product-security/bulletins/april-2023-bulletin"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Industrial IOT"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "9205 LTE Modem"
            },
            {
              "status": "affected",
              "version": "9206 LTE Modem"
            },
            {
              "status": "affected",
              "version": "9207 LTE Modem"
            },
            {
              "status": "affected",
              "version": "MDM8207"
            },
            {
              "status": "affected",
              "version": "QCA4004"
            },
            {
              "status": "affected",
              "version": "QTS110"
            },
            {
              "status": "affected",
              "version": "Snapdragon 1100 Wearable Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon 1200 Wearable Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon Wear 1300 Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon X5 LTE Modem"
            },
            {
              "status": "affected",
              "version": "WCD9306"
            },
            {
              "status": "affected",
              "version": "WCD9330"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Memory correction in modem due to buffer overwrite during coap connection"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy Without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-12T16:28:08.390Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://www.qualcomm.com/company/product-security/bulletins/april-2023-bulletin"
        }
      ],
      "title": "Buffer Copy Without Checking Size of Input in MODEM"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2022-25678",
    "datePublished": "2023-04-04T04:46:11.198Z",
    "dateReserved": "2022-02-22T11:38:09.283Z",
    "dateUpdated": "2024-08-03T04:42:50.661Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-25740 (GCVE-0-2022-25740)

Vulnerability from cvelistv5 – Published: 2023-04-04 04:46 – Updated: 2024-08-03 04:49
VLAI
Title
Buffer Copy Without Checking Size of Input in MODEM
Summary
Memory corruption in modem due to buffer overwrite while building an IPv6 multicast address based on the MAC address of the iface
CWE
  • CWE-120 - Buffer Copy Without Checking Size of Input ('Classic Buffer Overflow')
Assigner
Impacted products
Vendor Product Version
Qualcomm, Inc. Snapdragon Affected: 9205 LTE Modem
Affected: 9206 LTE Modem
Affected: 9207 LTE Modem
Affected: MDM8207
Affected: QCA4004
Affected: QTS110
Affected: Snapdragon 1100 Wearable Platform
Affected: Snapdragon 1200 Wearable Platform
Affected: Snapdragon Wear 1300 Platform
Affected: Snapdragon X5 LTE Modem
Affected: WCD9306
Affected: WCD9330
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:9205_lte_modem_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "9205_lte_modem_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:9206_lte_modem_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "9206_lte_modem_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:9207_lte_modem_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "9207_lte_modem_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:mdm8207_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "mdm8207_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:qca4004_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "qca4004_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:qts110_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "qts110_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:snapdragon_1100_wearable_platform_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "snapdragon_1100_wearable_platform_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:snapdragon_1200_wearable_platform_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "snapdragon_1200_wearable_platform_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:snapdragon_wear_1300_platform_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "snapdragon_wear_1300_platform_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:snapdragon_x5_lte_modem_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "snapdragon_x5_lte_modem_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:wcd9306_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "wcd9306_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          },
          {
            "cpes": [
              "cpe:2.3:o:qualcomm:wcd9330_firmware:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "wcd9330_firmware",
            "vendor": "qualcomm",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-25740",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-10T17:10:31.690045Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-10T17:10:37.509Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T04:49:43.186Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.qualcomm.com/company/product-security/bulletins/april-2023-bulletin"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Snapdragon Industrial IOT"
          ],
          "product": "Snapdragon",
          "vendor": "Qualcomm, Inc.",
          "versions": [
            {
              "status": "affected",
              "version": "9205 LTE Modem"
            },
            {
              "status": "affected",
              "version": "9206 LTE Modem"
            },
            {
              "status": "affected",
              "version": "9207 LTE Modem"
            },
            {
              "status": "affected",
              "version": "MDM8207"
            },
            {
              "status": "affected",
              "version": "QCA4004"
            },
            {
              "status": "affected",
              "version": "QTS110"
            },
            {
              "status": "affected",
              "version": "Snapdragon 1100 Wearable Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon 1200 Wearable Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon Wear 1300 Platform"
            },
            {
              "status": "affected",
              "version": "Snapdragon X5 LTE Modem"
            },
            {
              "status": "affected",
              "version": "WCD9306"
            },
            {
              "status": "affected",
              "version": "WCD9330"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Memory corruption in modem due to buffer overwrite while building an IPv6 multicast address based on the MAC address of the iface"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120 Buffer Copy Without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-12T16:28:28.852Z",
        "orgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
        "shortName": "qualcomm"
      },
      "references": [
        {
          "url": "https://www.qualcomm.com/company/product-security/bulletins/april-2023-bulletin"
        }
      ],
      "title": "Buffer Copy Without Checking Size of Input in MODEM"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2cfc7d3e-20d3-47ac-8db7-1b7285aff15f",
    "assignerShortName": "qualcomm",
    "cveId": "CVE-2022-25740",
    "datePublished": "2023-04-04T04:46:19.314Z",
    "dateReserved": "2022-02-22T11:38:09.313Z",
    "dateUpdated": "2024-08-03T04:49:43.186Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-26334 (GCVE-0-2022-26334)

Vulnerability from cvelistv5 – Published: 2022-04-12 09:07 – Updated: 2024-08-03 05:03
VLAI
Summary
A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices.
Severity
No CVSS data available.
CWE
  • CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
Vendor Product Version
Siemens SCALANCE X302-7 EEC (230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X302-7 EEC (2x 24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X304-2FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X306-1LD FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 230V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 230V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-2 EEC (2x 24V, coated) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X307-3LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LD Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH+ Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2LH+ Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M PoE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M PoE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M TS Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X308-2M TS Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X310FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X320-1 FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X320-1-2LD FE Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE X408-2 Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M TS (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-12M TS (24V) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M EEC (2x 24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (230V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (230V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE (24V, ports on rear) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SCALANCE XR324-4M PoE TS (24V, ports on front) Affected: All versions < V4.1.4
Create a notification for this product.
Siemens SIPLUS NET SCALANCE X308-2 Affected: All versions < V4.1.4
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T05:03:32.480Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "SCALANCE X302-7 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X302-7 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X304-2FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X306-1LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 230V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-2 EEC (2x 24V, coated)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X307-3LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LD",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2LH+",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M PoE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X308-2M TS",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X310FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1 FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X320-1-2LD FE",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE X408-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-12M TS (24V)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (230V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE (24V, ports on rear)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        },
        {
          "product": "SIPLUS NET SCALANCE X308-2",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.4"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-120",
              "description": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-12T09:07:54.000Z",
        "orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
        "shortName": "siemens"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productcert@siemens.com",
          "ID": "CVE-2022-26334",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X302-7 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X304-2FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X306-1LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 230V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-2 EEC (2x 24V, coated)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X307-3LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LD",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2LH+",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M PoE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X308-2M TS",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X310FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1 FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X320-1-2LD FE",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE X408-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-12M TS (24V)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M EEC (2x 24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (230V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE (24V, ports on rear)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SCALANCE XR324-4M PoE TS (24V, ports on front)",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    },
                    {
                      "product_name": "SIPLUS NET SCALANCE X308-2",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions \u003c V4.1.4"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Siemens"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability has been identified in SCALANCE X302-7 EEC (230V), SCALANCE X302-7 EEC (230V, coated), SCALANCE X302-7 EEC (24V), SCALANCE X302-7 EEC (24V, coated), SCALANCE X302-7 EEC (2x 230V), SCALANCE X302-7 EEC (2x 230V, coated), SCALANCE X302-7 EEC (2x 24V), SCALANCE X302-7 EEC (2x 24V, coated), SCALANCE X304-2FE, SCALANCE X306-1LD FE, SCALANCE X307-2 EEC (230V), SCALANCE X307-2 EEC (230V, coated), SCALANCE X307-2 EEC (24V), SCALANCE X307-2 EEC (24V, coated), SCALANCE X307-2 EEC (2x 230V), SCALANCE X307-2 EEC (2x 230V, coated), SCALANCE X307-2 EEC (2x 24V), SCALANCE X307-2 EEC (2x 24V, coated), SCALANCE X307-3, SCALANCE X307-3, SCALANCE X307-3LD, SCALANCE X307-3LD, SCALANCE X308-2, SCALANCE X308-2, SCALANCE X308-2LD, SCALANCE X308-2LD, SCALANCE X308-2LH, SCALANCE X308-2LH, SCALANCE X308-2LH+, SCALANCE X308-2LH+, SCALANCE X308-2M, SCALANCE X308-2M, SCALANCE X308-2M PoE, SCALANCE X308-2M PoE, SCALANCE X308-2M TS, SCALANCE X308-2M TS, SCALANCE X310, SCALANCE X310, SCALANCE X310FE, SCALANCE X310FE, SCALANCE X320-1 FE, SCALANCE X320-1-2LD FE, SCALANCE X408-2, SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on front), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (230V, ports on rear), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on front), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M (24V, ports on rear), SCALANCE XR324-12M TS (24V), SCALANCE XR324-12M TS (24V), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on front), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (24V, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on front), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 100-240VAC/60-250VDC, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on front), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M EEC (2x 24V, ports on rear), SCALANCE XR324-4M PoE (230V, ports on front), SCALANCE XR324-4M PoE (230V, ports on rear), SCALANCE XR324-4M PoE (24V, ports on front), SCALANCE XR324-4M PoE (24V, ports on rear), SCALANCE XR324-4M PoE TS (24V, ports on front), SIPLUS NET SCALANCE X308-2. Affected devices do not properly validate the GET parameter XNo of incoming HTTP requests. This could allow an unauthenticated remote attacker to crash affected devices."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-120: Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf",
              "refsource": "MISC",
              "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836527.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
    "assignerShortName": "siemens",
    "cveId": "CVE-2022-26334",
    "datePublished": "2022-04-12T09:07:54.000Z",
    "dateReserved": "2022-03-01T00:00:00.000Z",
    "dateUpdated": "2024-08-03T05:03:32.480Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

Mitigation ID: MIT-3

Phase: Requirements

Strategy: Language Selection

Description:

  • Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
  • For example, many languages that perform their own memory management, such as Java and Perl, are not subject to buffer overflows. Other languages, such as Ada and C#, typically provide overflow protection, but the protection can be disabled by the programmer.
  • Be wary that a language's interface to native code may still be subject to overflows, even if the language itself is theoretically safe.
Mitigation ID: MIT-4.1

Phase: Architecture and Design

Strategy: Libraries or Frameworks

Description:

  • Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
  • Examples include the Safe C String Library (SafeStr) by Messier and Viega [REF-57], and the Strsafe.h library from Microsoft [REF-56]. These libraries provide safer versions of overflow-prone string-handling functions.
Mitigation ID: MIT-10

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
  • D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation ID: MIT-9

Phase: Implementation

Description:

  • Consider adhering to the following rules when allocating and managing an application's memory:
  • Double check that your buffer is as large as you specify.
  • When using functions that accept a number of bytes to copy, such as strncpy(), be aware that if the destination buffer size is equal to the source buffer size, it may not NULL-terminate the string.
  • Check buffer boundaries if accessing the buffer in a loop and make sure there is no danger of writing past the allocated space.
  • If necessary, truncate all input strings to a reasonable length before passing them to the copy and concatenation functions.
Mitigation ID: MIT-5

Phase: Implementation

Strategy: Input Validation

Description:

  • Assume all input is malicious. Use an "accept known good" input validation strategy, i.e., use a list of acceptable inputs that strictly conform to specifications. Reject any input that does not strictly conform to specifications, or transform it into something that does.
  • When performing input validation, consider all potentially relevant properties, including length, type of input, the full range of acceptable values, missing or extra inputs, syntax, consistency across related fields, and conformance to business rules. As an example of business rule logic, "boat" may be syntactically valid because it only contains alphanumeric characters, but it is not valid if the input is only expected to contain colors such as "red" or "blue."
  • Do not rely exclusively on looking for malicious or malformed inputs. This is likely to miss at least one undesirable input, especially if the code's environment changes. This can give attackers enough room to bypass the intended validation. However, denylists can be useful for detecting potential attacks or determining which inputs are so malformed that they should be rejected outright.
Mitigation ID: MIT-15

Phase: Architecture and Design

Description:

  • For any security checks that are performed on the client side, ensure that these checks are duplicated on the server side, in order to avoid CWE-602. Attackers can bypass the client-side checks by modifying values after the checks have been performed, or by changing the client to remove the client-side checks entirely. Then, these modified values would be submitted to the server.
Mitigation ID: MIT-11

Phases: Operation, Build and Compilation

Strategy: Environment Hardening

Description:

  • Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
  • Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
  • For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
Mitigation ID: MIT-12

Phase: Operation

Strategy: Environment Hardening

Description:

  • Use a CPU and operating system that offers Data Execution Protection (using hardware NX or XD bits) or the equivalent techniques that simulate this feature in software, such as PaX [REF-60] [REF-61]. These techniques ensure that any instruction executed is exclusively at a memory address that is part of the code segment.
  • For more information on these techniques see D3-PSEP (Process Segment Execution Prevention) from D3FEND [REF-1336].
Mitigation

Phases: Build and Compilation, Operation

Description:

  • Most mitigating technologies at the compiler or OS level to date address only a subset of buffer overflow problems and rarely provide complete protection against even that subset. It is good practice to implement strategies to increase the workload of an attacker, such as leaving the attacker to guess an unknown value that changes every program execution.
Mitigation ID: MIT-13

Phase: Implementation

Description:

  • Replace unbounded copy functions with analogous functions that support length arguments, such as strcpy with strncpy. Create these if they are not available.
Mitigation ID: MIT-21

Phase: Architecture and Design

Strategy: Enforcement by Conversion

Description:

  • When the set of acceptable objects, such as filenames or URLs, is limited or known, create a mapping from a set of fixed input values (such as numeric IDs) to the actual filenames or URLs, and reject all other inputs.
Mitigation ID: MIT-17

Phases: Architecture and Design, Operation

Strategy: Environment Hardening

Description:

  • Run your code using the lowest privileges that are required to accomplish the necessary tasks [REF-76]. If possible, create isolated accounts with limited privileges that are only used for a single task. That way, a successful attack will not immediately give the attacker access to the rest of the software or its environment. For example, database applications rarely need to run as the database administrator, especially in day-to-day operations.
Mitigation ID: MIT-22

Phases: Architecture and Design, Operation

Strategy: Sandbox or Jail

Description:

  • Run the code in a "jail" or similar sandbox environment that enforces strict boundaries between the process and the operating system. This may effectively restrict which files can be accessed in a particular directory or which commands can be executed by the software.
  • OS-level examples include the Unix chroot jail, AppArmor, and SELinux. In general, managed code may provide some protection. For example, java.io.FilePermission in the Java SecurityManager allows the software to specify restrictions on file operations.
  • This may not be a feasible solution, and it only limits the impact to the operating system; the rest of the application may still be subject to compromise.
  • Be careful to avoid CWE-243 and other weaknesses related to jails.
CAPEC-10: Buffer Overflow via Environment Variables

This attack pattern involves causing a buffer overflow through manipulation of environment variables. Once the adversary finds that they can modify an environment variable, they may try to overflow associated buffers. This attack leverages implicit trust often placed in environment variables.

CAPEC-100: Overflow Buffers

Buffer Overflow attacks target improper or missing bounds checking on buffer operations, typically triggered by input injected by an adversary. As a consequence, an adversary is able to write past the boundaries of allocated buffer regions in memory, causing a program crash or potentially redirection of execution as per the adversaries' choice.

CAPEC-14: Client-side Injection-induced Buffer Overflow

This type of attack exploits a buffer overflow vulnerability in targeted client software through injection of malicious content from a custom-built hostile service. This hostile service is created to deliver the correct content to the client software. For example, if the client-side application is a browser, the service will host a webpage that the browser loads.

CAPEC-24: Filter Failure through Buffer Overflow

In this attack, the idea is to cause an active filter to fail by causing an oversized transaction. An attacker may try to feed overly long input strings to the program in an attempt to overwhelm the filter (by causing a buffer overflow) and hoping that the filter does not fail securely (i.e. the user input is let into the system unfiltered).

CAPEC-42: MIME Conversion

An attacker exploits a weakness in the MIME conversion routine to cause a buffer overflow and gain control over the mail server machine. The MIME system is designed to allow various different information formats to be interpreted and sent via e-mail. Attack points exist when data are converted to MIME compatible format and back.

CAPEC-44: Overflow Binary Resource File

An attack of this type exploits a buffer overflow vulnerability in the handling of binary resources. Binary resources may include music files like MP3, image files like JPEG files, and any other binary file. These attacks may pass unnoticed to the client machine through normal usage of files, such as a browser loading a seemingly innocent JPEG file. This can allow the adversary access to the execution stack and execute arbitrary code in the target process.

CAPEC-45: Buffer Overflow via Symbolic Links

This type of attack leverages the use of symbolic links to cause buffer overflows. An adversary can try to create or manipulate a symbolic link file such that its contents result in out of bounds data. When the target software processes the symbolic link file, it could potentially overflow internal buffers with insufficient bounds checking.

CAPEC-46: Overflow Variables and Tags

This type of attack leverages the use of tags or variables from a formatted configuration data to cause buffer overflow. The adversary crafts a malicious HTML page or configuration file that includes oversized strings, thus causing an overflow.

CAPEC-47: Buffer Overflow via Parameter Expansion

In this attack, the target software is given input that the adversary knows will be modified and expanded in size during processing. This attack relies on the target software failing to anticipate that the expanded data may exceed some internal limit, thereby creating a buffer overflow.

CAPEC-67: String Format Overflow in syslog()

This attack targets applications and software that uses the syslog() function insecurely. If an application does not explicitely use a format string parameter in a call to syslog(), user input can be placed in the format string parameter leading to a format string injection attack. Adversaries can then inject malicious format string commands into the function call leading to a buffer overflow. There are many reported software vulnerabilities with the root cause being a misuse of the syslog() function.

CAPEC-8: Buffer Overflow in an API Call

This attack targets libraries or shared code modules which are vulnerable to buffer overflow attacks. An adversary who has knowledge of known vulnerable libraries or shared code can easily target software that makes use of these libraries. All clients that make use of the code library thus become vulnerable by association. This has a very broad effect on security across a system, usually affecting more than one software process.

CAPEC-9: Buffer Overflow in Local Command-Line Utilities

This attack targets command-line utilities available in a number of shells. An adversary can leverage a vulnerability found in a command-line utility to escalate privilege to root.

CAPEC-92: Forced Integer Overflow

This attack forces an integer variable to go out of range. The integer variable is often used as an offset such as size of memory allocation or similarly. The attacker would typically control the value of such variable and try to get it out of range. For instance the integer in question is incremented past the maximum possible value, it may wrap to become a very small, or negative number, therefore providing a very incorrect value which can lead to unexpected behavior. At worst the attacker can execute arbitrary code.

Back to CWE stats page