CWE-119
Improper Restriction of Operations within the Bounds of a Memory Buffer
The product performs operations on a memory buffer, but it reads from or writes to a memory location outside the buffer's intended boundary. This may result in read or write operations on unexpected memory locations that could be linked to other variables, data structures, or internal program data.
CVE-2019-11933 (GCVE-0-2019-11933)
Vulnerability from cvelistv5 – Published: 2019-10-23 15:40 – Updated: 2024-08-04 23:10- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer (CWE-119)
| URL | Tags |
|---|---|
| https://www.facebook.com/security/advisories/cve-… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| WhatsApp for Android |
Affected:
2.19.291
Affected: unspecified , < 2.19.291 (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:29.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.facebook.com/security/advisories/cve-2019-11933"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "WhatsApp for Android",
"vendor": "Facebook",
"versions": [
{
"status": "affected",
"version": "2.19.291"
},
{
"lessThan": "2.19.291",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"dateAssigned": "2019-10-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A heap buffer overflow bug in libpl_droidsonroids_gif before 1.2.19, as used in WhatsApp for Android before version 2.19.291 could allow remote attackers to execute arbitrary code or cause a denial of service."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "Improper Restriction of Operations within the Bounds of a Memory Buffer (CWE-119)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-23T15:40:10.000Z",
"orgId": "4fc57720-52fe-4431-a0fb-3d2c8747b827",
"shortName": "facebook"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.facebook.com/security/advisories/cve-2019-11933"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve-assign@fb.com",
"DATE_ASSIGNED": "2019-10-22",
"ID": "CVE-2019-11933",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "WhatsApp for Android",
"version": {
"version_data": [
{
"version_affected": "!=\u003e",
"version_value": "2.19.291"
},
{
"version_affected": "\u003c",
"version_value": "2.19.291"
}
]
}
}
]
},
"vendor_name": "Facebook"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A heap buffer overflow bug in libpl_droidsonroids_gif before 1.2.19, as used in WhatsApp for Android before version 2.19.291 could allow remote attackers to execute arbitrary code or cause a denial of service."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Improper Restriction of Operations within the Bounds of a Memory Buffer (CWE-119)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.facebook.com/security/advisories/cve-2019-11933",
"refsource": "CONFIRM",
"url": "https://www.facebook.com/security/advisories/cve-2019-11933"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "4fc57720-52fe-4431-a0fb-3d2c8747b827",
"assignerShortName": "facebook",
"cveId": "CVE-2019-11933",
"datePublished": "2019-10-23T15:40:10.000Z",
"dateReserved": "2019-05-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:10:29.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12673 (GCVE-0-2019-12673)
Vulnerability from cvelistv5 – Published: 2019-10-02 19:00 – Updated: 2024-11-19 18:54| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco Adaptive Security Appliance (ASA) Software |
Affected:
unspecified , < n/a
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:24:39.388Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20191002 Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software FTP Inspection Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-asa-dos"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-12673",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-19T17:22:49.483667Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-19T18:54:42.216Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Adaptive Security Appliance (ASA) Software",
"vendor": "Cisco",
"versions": [
{
"lessThan": "n/a",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-10-02T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the FTP inspection engine of Cisco Adaptive Security (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of FTP data. An attacker could exploit this vulnerability by sending malicious FTP traffic through an affected device. A successful exploit could allow the attacker to cause a DoS condition on the affected device."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-02T19:00:18.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20191002 Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software FTP Inspection Denial of Service Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-asa-dos"
}
],
"source": {
"advisory": "cisco-sa-20191002-asa-dos",
"defect": [
[
"CSCvo83169"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software FTP Inspection Denial of Service Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-10-02T16:00:00-0700",
"ID": "CVE-2019-12673",
"STATE": "PUBLIC",
"TITLE": "Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software FTP Inspection Denial of Service Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Adaptive Security Appliance (ASA) Software",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the FTP inspection engine of Cisco Adaptive Security (ASA) Software and Cisco Firepower Threat Defense (FTD) Software could allow an unauthenticated, remote attacker to cause a denial of service (DoS) condition on an affected device. The vulnerability is due to insufficient validation of FTP data. An attacker could exploit this vulnerability by sending malicious FTP traffic through an affected device. A successful exploit could allow the attacker to cause a DoS condition on the affected device."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.6",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:C/C:N/I:N/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20191002 Cisco Adaptive Security Appliance Software and Firepower Threat Defense Software FTP Inspection Denial of Service Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-asa-dos"
}
]
},
"source": {
"advisory": "cisco-sa-20191002-asa-dos",
"defect": [
[
"CSCvo83169"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-12673",
"datePublished": "2019-10-02T19:00:18.444Z",
"dateReserved": "2019-06-04T00:00:00.000Z",
"dateUpdated": "2024-11-19T18:54:42.216Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12687 (GCVE-0-2019-12687)
Vulnerability from cvelistv5 – Published: 2019-10-02 19:06 – Updated: 2024-11-20 17:07| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco Firepower Management Center |
Affected:
unspecified , < n/a
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:24:39.286Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20191002 Cisco Firepower Management Center Remote Code Execution Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-12687",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T16:51:18.605254Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T17:07:28.601Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Firepower Management Center",
"vendor": "Cisco",
"versions": [
{
"lessThan": "n/a",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-10-02T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-02T19:06:44.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20191002 Cisco Firepower Management Center Remote Code Execution Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
],
"source": {
"advisory": "cisco-sa-20191002-fmc-rce",
"defect": [
[
"CSCvf87540",
"CSCvg04183"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Firepower Management Center Remote Code Execution Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-10-02T16:00:00-0700",
"ID": "CVE-2019-12687",
"STATE": "PUBLIC",
"TITLE": "Cisco Firepower Management Center Remote Code Execution Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Firepower Management Center",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.8",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20191002 Cisco Firepower Management Center Remote Code Execution Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
]
},
"source": {
"advisory": "cisco-sa-20191002-fmc-rce",
"defect": [
[
"CSCvf87540",
"CSCvg04183"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-12687",
"datePublished": "2019-10-02T19:06:44.191Z",
"dateReserved": "2019-06-04T00:00:00.000Z",
"dateUpdated": "2024-11-20T17:07:28.601Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12688 (GCVE-0-2019-12688)
Vulnerability from cvelistv5 – Published: 2019-10-02 19:06 – Updated: 2024-11-20 17:07| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco Firepower Management Center |
Affected:
unspecified , < n/a
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:24:39.182Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20191002 Cisco Firepower Management Center Remote Code Execution Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-12688",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T16:51:16.951590Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T17:07:21.920Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco Firepower Management Center",
"vendor": "Cisco",
"versions": [
{
"lessThan": "n/a",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-10-02T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-02T19:06:44.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20191002 Cisco Firepower Management Center Remote Code Execution Vulnerability",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
],
"source": {
"advisory": "cisco-sa-20191002-fmc-rce",
"defect": [
[
"CSCvf87540",
"CSCvg04183"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco Firepower Management Center Remote Code Execution Vulnerability",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-10-02T16:00:00-0700",
"ID": "CVE-2019-12688",
"STATE": "PUBLIC",
"TITLE": "Cisco Firepower Management Center Remote Code Execution Vulnerability"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco Firepower Management Center",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability in the web UI of the Cisco Firepower Management Center (FMC) could allow an authenticated, remote attacker to execute arbitrary commands on an affected device. The vulnerability is due to insufficient input validation. An attacker could exploit this vulnerability by sending crafted input to the web UI. A successful exploit could allow the attacker to execute arbitrary commands within the affected device."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any public announcements or malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.8",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20191002 Cisco Firepower Management Center Remote Code Execution Vulnerability",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191002-fmc-rce"
}
]
},
"source": {
"advisory": "cisco-sa-20191002-fmc-rce",
"defect": [
[
"CSCvf87540",
"CSCvg04183"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-12688",
"datePublished": "2019-10-02T19:06:44.622Z",
"dateReserved": "2019-06-04T00:00:00.000Z",
"dateUpdated": "2024-11-20T17:07:21.920Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12806 (GCVE-0-2019-12806)
Vulnerability from cvelistv5 – Published: 2019-08-13 19:10 – Updated: 2024-08-04 23:32- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags |
|---|---|
| https://www.boho.or.kr/krcert/secNoticeView.do?bu… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:32:55.472Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35111"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "UniSign",
"vendor": "CROSSCERT",
"versions": [
{
"status": "affected",
"version": "2.0.4.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "UniSign 2.0.4.0 and earlier version contains a stack-based buffer overflow vulnerability which can overwrite the stack with arbitrary data, due to a buffer overflow in a library. That leads remote attacker to execute arbitrary code via crafted https packets."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-13T19:10:06.000Z",
"orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
"shortName": "krcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35111"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vuln@krcert.or.kr",
"ID": "CVE-2019-12806",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "UniSign",
"version": {
"version_data": [
{
"version_value": "2.0.4.0"
}
]
}
}
]
},
"vendor_name": "CROSSCERT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "UniSign 2.0.4.0 and earlier version contains a stack-based buffer overflow vulnerability which can overwrite the stack with arbitrary data, due to a buffer overflow in a library. That leads remote attacker to execute arbitrary code via crafted https packets."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35111",
"refsource": "MISC",
"url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35111"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
"assignerShortName": "krcert",
"cveId": "CVE-2019-12806",
"datePublished": "2019-08-13T19:10:06.000Z",
"dateReserved": "2019-06-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:32:55.472Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-12807 (GCVE-0-2019-12807)
Vulnerability from cvelistv5 – Published: 2019-08-13 19:22 – Updated: 2024-08-04 23:32- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags |
|---|---|
| https://www.boho.or.kr/krcert/secNoticeView.do?bu… | x_refsource_MISC |
| https://www.altools.co.kr/Download/ALZip.aspx#n | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:32:55.387Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35114"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.altools.co.kr/Download/ALZip.aspx#n"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "ALZIP",
"vendor": "ESTSOFT",
"versions": [
{
"status": "affected",
"version": "10.83"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Alzip 10.83 and earlier version contains a stack-based buffer overflow vulnerability, caused by improper bounds checking during the parsing of crafted ISO archive file format. By persuading a victim to open a specially-crafted ISO archive file, an attacker could execution arbitrary code."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-08-13T19:22:35.000Z",
"orgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
"shortName": "krcert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35114"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.altools.co.kr/Download/ALZip.aspx#n"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vuln@krcert.or.kr",
"ID": "CVE-2019-12807",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "ALZIP",
"version": {
"version_data": [
{
"version_value": "10.83"
}
]
}
}
]
},
"vendor_name": "ESTSOFT"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Alzip 10.83 and earlier version contains a stack-based buffer overflow vulnerability, caused by improper bounds checking during the parsing of crafted ISO archive file format. By persuading a victim to open a specially-crafted ISO archive file, an attacker could execution arbitrary code."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119 Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35114",
"refsource": "MISC",
"url": "https://www.boho.or.kr/krcert/secNoticeView.do?bulletin_writing_sequence=35114"
},
{
"name": "https://www.altools.co.kr/Download/ALZip.aspx#n",
"refsource": "MISC",
"url": "https://www.altools.co.kr/Download/ALZip.aspx#n"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cdd7a122-0fae-4202-8d86-14efbacc2863",
"assignerShortName": "krcert",
"cveId": "CVE-2019-12807",
"datePublished": "2019-08-13T19:22:35.000Z",
"dateReserved": "2019-06-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:32:55.387Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13522 (GCVE-0-2019-13522)
Vulnerability from cvelistv5 – Published: 2019-09-04 14:29 – Updated: 2024-08-04 23:57- CWE-119 - IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119
| URL | Tags |
|---|---|
| https://www.us-cert.gov/ics/advisories/icsa-19-246-02 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| n/a | EZ PLC Editor |
Affected:
Versions 1.8.41 and prior
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:57:39.167Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-246-02"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EZ PLC Editor",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Versions 1.8.41 and prior"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker could use a specially crafted project file to corrupt the memory and execute code under the privileges of the EZ PLC Editor Versions 1.8.41 and prior."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-04T14:29:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-246-02"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2019-13522",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EZ PLC Editor",
"version": {
"version_data": [
{
"version_value": "Versions 1.8.41 and prior"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could use a specially crafted project file to corrupt the memory and execute code under the privileges of the EZ PLC Editor Versions 1.8.41 and prior."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "IMPROPER RESTRICTION OF OPERATIONS WITHIN THE BOUNDS OF A MEMORY BUFFER CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-246-02",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-246-02"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2019-13522",
"datePublished": "2019-09-04T14:29:00.000Z",
"dateReserved": "2019-07-11T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:57:39.167Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-13942 (GCVE-0-2019-13942)
Vulnerability from cvelistv5 – Published: 2019-12-12 19:08 – Updated: 2024-08-05 00:05- CWE-119 - Improper Restriction of Operations within the Bounds of a Memory Buffer
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
| https://www.us-cert.gov/ics/advisories/icsa-19-344-07 | x_refsource_MISC |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | EN100 Ethernet module DNP3 variant |
Affected:
All versions
|
|
| Siemens AG | EN100 Ethernet module IEC 61850 variant |
Affected:
All versions < V4.37
|
|
| Siemens AG | EN100 Ethernet module IEC104 variant |
Affected:
All versions
|
|
| Siemens AG | EN100 Ethernet module Modbus TCP variant |
Affected:
All versions
|
|
| Siemens AG | EN100 Ethernet module PROFINET IO variant |
Affected:
All versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:05:44.006Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "EN100 Ethernet module DNP3 variant",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module IEC 61850 variant",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V4.37"
}
]
},
{
"product": "EN100 Ethernet module IEC104 variant",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module Modbus TCP variant",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "EN100 Ethernet module PROFINET IO variant",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-16T15:35:24.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-13942",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "EN100 Ethernet module DNP3 variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module IEC 61850 variant",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V4.37"
}
]
}
},
{
"product_name": "EN100 Ethernet module IEC104 variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module Modbus TCP variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "EN100 Ethernet module PROFINET IO variant",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in EN100 Ethernet module DNP3 variant (All versions), EN100 Ethernet module IEC 61850 variant (All versions \u003c V4.37), EN100 Ethernet module IEC104 variant (All versions), EN100 Ethernet module Modbus TCP variant (All versions), EN100 Ethernet module PROFINET IO variant (All versions). An unauthorized user could exploit a buffer overflow vulnerability in the webserver. Specially crafted packets sent could cause a Denial-of-Service condition and if certain conditions are met, the affected devices must be restarted manually to fully recover. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119: Improper Restriction of Operations within the Bounds of a Memory Buffer"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-418979.pdf"
},
{
"name": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07",
"refsource": "MISC",
"url": "https://www.us-cert.gov/ics/advisories/icsa-19-344-07"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-13942",
"datePublished": "2019-12-12T19:08:46.000Z",
"dateReserved": "2019-07-18T00:00:00.000Z",
"dateUpdated": "2024-08-05T00:05:44.006Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-15240 (GCVE-0-2019-15240)
Vulnerability from cvelistv5 – Published: 2019-10-16 18:36 – Updated: 2024-11-20 17:06| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco SPA112 2-Port Phone Adapter |
Affected:
unspecified , < n/a
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:42:03.735Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-rce"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-15240",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T16:51:09.219109Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T17:06:47.206Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco SPA112 2-Port Phone Adapter",
"vendor": "Cisco",
"versions": [
{
"lessThan": "n/a",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-10-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent attacker to execute arbitrary code with elevated privileges. The vulnerabilities are due to improper validation of user-supplied input to the web-based management interface. An attacker could exploit these vulnerabilities by authenticating to the web-based management interface and sending crafted requests to an affected device. A successful exploit could allow the attacker to execute arbitrary code with elevated privileges. Note: The web-based management interface is enabled by default."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-16T18:36:30.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-rce"
}
],
"source": {
"advisory": "cisco-sa-20191016-spa-rce",
"defect": [
[
"CSCvq50494"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-10-16T16:00:00-0700",
"ID": "CVE-2019-15240",
"STATE": "PUBLIC",
"TITLE": "Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco SPA112 2-Port Phone Adapter",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent attacker to execute arbitrary code with elevated privileges. The vulnerabilities are due to improper validation of user-supplied input to the web-based management interface. An attacker could exploit these vulnerabilities by authenticating to the web-based management interface and sending crafted requests to an affected device. A successful exploit could allow the attacker to execute arbitrary code with elevated privileges. Note: The web-based management interface is enabled by default."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-rce"
}
]
},
"source": {
"advisory": "cisco-sa-20191016-spa-rce",
"defect": [
[
"CSCvq50494"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-15240",
"datePublished": "2019-10-16T18:36:30.976Z",
"dateReserved": "2019-08-20T00:00:00.000Z",
"dateUpdated": "2024-11-20T17:06:47.206Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-15241 (GCVE-0-2019-15241)
Vulnerability from cvelistv5 – Published: 2019-10-16 18:36 – Updated: 2024-11-20 17:06| URL | Tags |
|---|---|
| https://tools.cisco.com/security/center/content/C… | vendor-advisoryx_refsource_CISCO |
| Vendor | Product | Version | |
|---|---|---|---|
| Cisco | Cisco SPA112 2-Port Phone Adapter |
Affected:
unspecified , < n/a
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T00:42:03.628Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO",
"x_transferred"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-rce"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2019-15241",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-11-20T16:51:07.055031Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-11-20T17:06:40.283Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Cisco SPA112 2-Port Phone Adapter",
"vendor": "Cisco",
"versions": [
{
"lessThan": "n/a",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"datePublic": "2019-10-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent attacker to execute arbitrary code with elevated privileges. The vulnerabilities are due to improper validation of user-supplied input to the web-based management interface. An attacker could exploit these vulnerabilities by authenticating to the web-based management interface and sending crafted requests to an affected device. A successful exploit could allow the attacker to execute arbitrary code with elevated privileges. Note: The web-based management interface is enabled by default."
}
],
"exploits": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any malicious use of the vulnerability that is described in this advisory."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-119",
"description": "CWE-119",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-10-16T18:36:31.000Z",
"orgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"shortName": "cisco"
},
"references": [
{
"name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"tags": [
"vendor-advisory",
"x_refsource_CISCO"
],
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-rce"
}
],
"source": {
"advisory": "cisco-sa-20191016-spa-rce",
"defect": [
[
"CSCvq50494"
]
],
"discovery": "INTERNAL"
},
"title": "Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "psirt@cisco.com",
"DATE_PUBLIC": "2019-10-16T16:00:00-0700",
"ID": "CVE-2019-15241",
"STATE": "PUBLIC",
"TITLE": "Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Cisco SPA112 2-Port Phone Adapter",
"version": {
"version_data": [
{
"affected": "\u003c",
"version_affected": "\u003c",
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "Cisco"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Multiple vulnerabilities in Cisco SPA100 Series Analog Telephone Adapters (ATAs) could allow an authenticated, adjacent attacker to execute arbitrary code with elevated privileges. The vulnerabilities are due to improper validation of user-supplied input to the web-based management interface. An attacker could exploit these vulnerabilities by authenticating to the web-based management interface and sending crafted requests to an affected device. A successful exploit could allow the attacker to execute arbitrary code with elevated privileges. Note: The web-based management interface is enabled by default."
}
]
},
"exploit": [
{
"lang": "en",
"value": "The Cisco Product Security Incident Response Team (PSIRT) is not aware of any malicious use of the vulnerability that is described in this advisory."
}
],
"impact": {
"cvss": {
"baseScore": "8.0",
"vectorString": "CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-119"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "20191016 Cisco SPA100 Series Analog Telephone Adapters Remote Code Execution Vulnerabilities",
"refsource": "CISCO",
"url": "https://tools.cisco.com/security/center/content/CiscoSecurityAdvisory/cisco-sa-20191016-spa-rce"
}
]
},
"source": {
"advisory": "cisco-sa-20191016-spa-rce",
"defect": [
[
"CSCvq50494"
]
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "d1c1063e-7a18-46af-9102-31f8928bc633",
"assignerShortName": "cisco",
"cveId": "CVE-2019-15241",
"datePublished": "2019-10-16T18:36:31.414Z",
"dateReserved": "2019-08-20T00:00:00.000Z",
"dateUpdated": "2024-11-20T17:06:40.283Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Mitigation ID: MIT-3
Phase: Requirements
Strategy: Language Selection
Description:
- Use a language that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
- For example, many languages that perform their own memory management, such as Java and Perl, are not subject to buffer overflows. Other languages, such as Ada and C#, typically provide overflow protection, but the protection can be disabled by the programmer.
- Be wary that a language's interface to native code may still be subject to overflows, even if the language itself is theoretically safe.
Mitigation ID: MIT-4.1
Phase: Architecture and Design
Strategy: Libraries or Frameworks
Description:
- Use a vetted library or framework that does not allow this weakness to occur or provides constructs that make this weakness easier to avoid.
- Examples include the Safe C String Library (SafeStr) by Messier and Viega [REF-57], and the Strsafe.h library from Microsoft [REF-56]. These libraries provide safer versions of overflow-prone string-handling functions.
Mitigation ID: MIT-10
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Use automatic buffer overflow detection mechanisms that are offered by certain compilers or compiler extensions. Examples include: the Microsoft Visual Studio /GS flag, Fedora/Red Hat FORTIFY_SOURCE GCC flag, StackGuard, and ProPolice, which provide various mechanisms including canary-based detection and range/index checking.
- D3-SFCV (Stack Frame Canary Validation) from D3FEND [REF-1334] discusses canary-based detection in detail.
Mitigation ID: MIT-9
Phase: Implementation
Description:
- Consider adhering to the following rules when allocating and managing an application's memory:
- Double check that the buffer is as large as specified.
- When using functions that accept a number of bytes to copy, such as strncpy(), be aware that if the destination buffer size is equal to the source buffer size, it may not NULL-terminate the string.
- Check buffer boundaries if accessing the buffer in a loop and make sure there is no danger of writing past the allocated space.
- If necessary, truncate all input strings to a reasonable length before passing them to the copy and concatenation functions.
Mitigation ID: MIT-11
Phases: Operation, Build and Compilation
Strategy: Environment Hardening
Description:
- Run or compile the software using features or extensions that randomly arrange the positions of a program's executable and libraries in memory. Because this makes the addresses unpredictable, it can prevent an attacker from reliably jumping to exploitable code.
- Examples include Address Space Layout Randomization (ASLR) [REF-58] [REF-60] and Position-Independent Executables (PIE) [REF-64]. Imported modules may be similarly realigned if their default memory addresses conflict with other modules, in a process known as "rebasing" (for Windows) and "prelinking" (for Linux) [REF-1332] using randomly generated addresses. ASLR for libraries cannot be used in conjunction with prelink since it would require relocating the libraries at run-time, defeating the whole purpose of prelinking.
- For more information on these techniques see D3-SAOR (Segment Address Offset Randomization) from D3FEND [REF-1335].
Mitigation ID: MIT-12
Phase: Operation
Strategy: Environment Hardening
Description:
- Use a CPU and operating system that offers Data Execution Protection (using hardware NX or XD bits) or the equivalent techniques that simulate this feature in software, such as PaX [REF-60] [REF-61]. These techniques ensure that any instruction executed is exclusively at a memory address that is part of the code segment.
- For more information on these techniques see D3-PSEP (Process Segment Execution Prevention) from D3FEND [REF-1336].
Mitigation ID: MIT-13
Phase: Implementation
Description:
- Replace unbounded copy functions with analogous functions that support length arguments, such as strcpy with strncpy. Create these if they are not available.
CAPEC-10: Buffer Overflow via Environment Variables
This attack pattern involves causing a buffer overflow through manipulation of environment variables. Once the adversary finds that they can modify an environment variable, they may try to overflow associated buffers. This attack leverages implicit trust often placed in environment variables.
CAPEC-100: Overflow Buffers
Buffer Overflow attacks target improper or missing bounds checking on buffer operations, typically triggered by input injected by an adversary. As a consequence, an adversary is able to write past the boundaries of allocated buffer regions in memory, causing a program crash or potentially redirection of execution as per the adversaries' choice.
CAPEC-123: Buffer Manipulation
An adversary manipulates an application's interaction with a buffer in an attempt to read or modify data they shouldn't have access to. Buffer attacks are distinguished in that it is the buffer space itself that is the target of the attack rather than any code responsible for interpreting the content of the buffer. In virtually all buffer attacks the content that is placed in the buffer is immaterial. Instead, most buffer attacks involve retrieving or providing more input than can be stored in the allocated buffer, resulting in the reading or overwriting of other unintended program memory.
CAPEC-14: Client-side Injection-induced Buffer Overflow
This type of attack exploits a buffer overflow vulnerability in targeted client software through injection of malicious content from a custom-built hostile service. This hostile service is created to deliver the correct content to the client software. For example, if the client-side application is a browser, the service will host a webpage that the browser loads.
CAPEC-24: Filter Failure through Buffer Overflow
In this attack, the idea is to cause an active filter to fail by causing an oversized transaction. An attacker may try to feed overly long input strings to the program in an attempt to overwhelm the filter (by causing a buffer overflow) and hoping that the filter does not fail securely (i.e. the user input is let into the system unfiltered).
CAPEC-42: MIME Conversion
An attacker exploits a weakness in the MIME conversion routine to cause a buffer overflow and gain control over the mail server machine. The MIME system is designed to allow various different information formats to be interpreted and sent via e-mail. Attack points exist when data are converted to MIME compatible format and back.
CAPEC-44: Overflow Binary Resource File
An attack of this type exploits a buffer overflow vulnerability in the handling of binary resources. Binary resources may include music files like MP3, image files like JPEG files, and any other binary file. These attacks may pass unnoticed to the client machine through normal usage of files, such as a browser loading a seemingly innocent JPEG file. This can allow the adversary access to the execution stack and execute arbitrary code in the target process.
CAPEC-45: Buffer Overflow via Symbolic Links
This type of attack leverages the use of symbolic links to cause buffer overflows. An adversary can try to create or manipulate a symbolic link file such that its contents result in out of bounds data. When the target software processes the symbolic link file, it could potentially overflow internal buffers with insufficient bounds checking.
CAPEC-46: Overflow Variables and Tags
This type of attack leverages the use of tags or variables from a formatted configuration data to cause buffer overflow. The adversary crafts a malicious HTML page or configuration file that includes oversized strings, thus causing an overflow.
CAPEC-47: Buffer Overflow via Parameter Expansion
In this attack, the target software is given input that the adversary knows will be modified and expanded in size during processing. This attack relies on the target software failing to anticipate that the expanded data may exceed some internal limit, thereby creating a buffer overflow.
CAPEC-8: Buffer Overflow in an API Call
This attack targets libraries or shared code modules which are vulnerable to buffer overflow attacks. An adversary who has knowledge of known vulnerable libraries or shared code can easily target software that makes use of these libraries. All clients that make use of the code library thus become vulnerable by association. This has a very broad effect on security across a system, usually affecting more than one software process.
CAPEC-9: Buffer Overflow in Local Command-Line Utilities
This attack targets command-line utilities available in a number of shells. An adversary can leverage a vulnerability found in a command-line utility to escalate privilege to root.