Common Weakness Enumeration

CWE-710

Discouraged

Improper Adherence to Coding Standards

Abstraction: Pillar · Status: Incomplete

The product does not follow certain coding rules for development, which can lead to resultant weaknesses or increase the severity of the associated vulnerabilities.

13 vulnerabilities reference this CWE, most recent first.

GHSA-H69J-H5Q5-6QW6

Vulnerability from github – Published: 2025-11-24 21:31 – Updated: 2025-11-24 21:31
VLAI
Details

Insufficient validation within Xilinx Run Time framework could allow a local attacker to escalate privileges from user space to kernel space, potentially compromising confidentiality, integrity, and/or availability.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2025-0007"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-710"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2025-11-24T21:16:02Z",
    "severity": "MODERATE"
  },
  "details": "Insufficient validation within Xilinx Run Time framework could allow a local attacker to escalate privileges from user space to kernel space, potentially compromising confidentiality, integrity, and/or availability.",
  "id": "GHSA-h69j-h5q5-6qw6",
  "modified": "2025-11-24T21:31:00Z",
  "published": "2025-11-24T21:31:00Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2025-0007"
    },
    {
      "type": "WEB",
      "url": "https://www.amd.com/en/resources/product-security/bulletin/AMD-SB-8014.html"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:L",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-M34M-MFQ8-3JHW

Vulnerability from github – Published: 2023-09-27 15:30 – Updated: 2024-04-04 07:51
VLAI
Details

Palantir Gotham was found to be vulnerable to a bug where under certain circumstances, the frontend could have applied an incorrect classification to a newly created property or link.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2023-30961"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-1021",
      "CWE-710"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2023-09-27T15:18:52Z",
    "severity": "MODERATE"
  },
  "details": "Palantir Gotham was found to be vulnerable to a bug where under certain circumstances, the frontend could have applied an incorrect classification to a newly created property or link.",
  "id": "GHSA-m34m-mfq8-3jhw",
  "modified": "2024-04-04T07:51:38Z",
  "published": "2023-09-27T15:30:34Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2023-30961"
    },
    {
      "type": "WEB",
      "url": "https://palantir.safebase.us/?tcuUid=2755c49f-2c30-459e-8bdf-f95ef3692da4"
    }
  ],
  "schema_version": "1.4.0",
  "severity": [
    {
      "score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:N/A:N",
      "type": "CVSS_V3"
    }
  ]
}

GHSA-Q573-WGW4-2H26

Vulnerability from github – Published: 2022-05-24 19:06 – Updated: 2022-05-24 19:06
VLAI
Details

In Weidmueller Industrial WLAN devices in multiple versions an exploitable privilege escalation vulnerability exists in the iw_console functionality. A specially crafted menu selection string can cause an escape from the restricted console, resulting in system access as the root user. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.

Show details on source website

{
  "affected": [],
  "aliases": [
    "CVE-2021-33528"
  ],
  "database_specific": {
    "cwe_ids": [
      "CWE-710"
    ],
    "github_reviewed": false,
    "github_reviewed_at": null,
    "nvd_published_at": "2021-06-25T19:15:00Z",
    "severity": "HIGH"
  },
  "details": "In Weidmueller Industrial WLAN devices in multiple versions an exploitable privilege escalation vulnerability exists in the iw_console functionality. A specially crafted menu selection string can cause an escape from the restricted console, resulting in system access as the root user. An attacker can send commands while authenticated as a low privilege user to trigger this vulnerability.",
  "id": "GHSA-q573-wgw4-2h26",
  "modified": "2022-05-24T19:06:17Z",
  "published": "2022-05-24T19:06:17Z",
  "references": [
    {
      "type": "ADVISORY",
      "url": "https://nvd.nist.gov/vuln/detail/CVE-2021-33528"
    },
    {
      "type": "WEB",
      "url": "https://cert.vde.com/en-us/advisories/vde-2021-026"
    }
  ],
  "schema_version": "1.4.0",
  "severity": []
}

Mitigation
Policy

Select and require coding standards. Ensure that they include security concerns.

Mitigation
Implementation

Closely follow coding standards, possibly enforcing them upon checkin of the code into a source control system or with periodic analyses.

No CAPEC attack patterns related to this CWE.