Common Weakness Enumeration

CWE-353

Allowed

Missing Support for Integrity Check

Abstraction: Base · Status: Draft

The product uses a transmission protocol that does not include a mechanism for verifying the integrity of the data during transmission, such as a checksum.

79 vulnerabilities reference this CWE, most recent first.

CVE-2026-18536 (GCVE-0-2026-18536)

Vulnerability from cvelistv5 – Published: 2026-08-01 10:35 – Updated: 2026-08-03 19:55
VLAI
Title
Data::Entropy versions before 0.010 for Perl read remote entropy sources over plain HTTP
Summary
Data::Entropy versions before 0.010 for Perl read remote entropy sources over plain HTTP. The Data::Entropy::RawSource::RandomOrg and Data::Entropy::RawSource::RandomnumbersInfo remote sources are accessed over plain HTTP. The Data::Entropy::RawSource::RandomOrg integrity check trivially matches any non-empty byte string. Any on-path attacker, such as open WiFi, a compromised ISP, captive portal, or a hostile egress proxy substitutes the response and thereby chooses the bytes returned by rand_bits and rand_int for every application that selected one of these sources via with_entropy_source. The _checkbuf method response is equally attacker-controlled, so the retry/sleep behaviour is steerable too.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-03 19:55 UTC
CWE
  • CWE-319 - Cleartext Transmission of Sensitive Information
  • CWE-353 - Missing Support for Integrity Check
Assigner
CPANSec CNA under the redhat root
CNA scorecard C 64/100 over 265 records in the last 180 days details
Impacted products
Vendor Product Version
RRWO Data::Entropy Affected: 0 , < 0.010 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2026-08-01T15:23:24.896Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://www.openwall.com/lists/oss-security/2026/08/01/8"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2026-18536",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-03T19:55:08.843137Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-03T19:55:35.372Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "collectionURL": "https://cpan.org/modules",
          "defaultStatus": "unaffected",
          "packageName": "Data-Entropy",
          "product": "Data::Entropy",
          "programFiles": [
            "lib/Data/Entropy/RawSource/RandomOrg.pm",
            "lib/Data/Entropy/RawSource/RandomnumbersInfo.pm"
          ],
          "programRoutines": [
            {
              "name": "Data::Entropy::RawSource::RandomOrg::_checkbuf"
            },
            {
              "name": "Data::Entropy::RawSource::RandomOrg::_ensure_buffer"
            },
            {
              "name": "Data::Entropy::RawSource::RandomnumbersInfo::_ensure_buffer"
            }
          ],
          "repo": "https://github.com/robrwo/Data-Entropy",
          "vendor": "RRWO",
          "versions": [
            {
              "lessThan": "0.010",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Data::Entropy versions before 0.010 for Perl read remote entropy sources over plain HTTP.\n\nThe Data::Entropy::RawSource::RandomOrg and Data::Entropy::RawSource::RandomnumbersInfo remote sources are accessed over plain HTTP.\n\nThe Data::Entropy::RawSource::RandomOrg integrity check trivially matches any non-empty byte string.\n\nAny on-path attacker, such as open WiFi, a compromised ISP, captive portal, or a hostile egress proxy substitutes the response and thereby chooses the bytes returned by rand_bits and rand_int for every application that selected one of these sources via with_entropy_source. The _checkbuf method response is equally attacker-controlled, so the retry/sleep behaviour is steerable too."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-319",
              "description": "CWE-319 Cleartext Transmission of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-01T10:35:38.392Z",
        "orgId": "9b29abf9-4ab0-4765-b253-1875cd9b441e",
        "shortName": "CPANSec"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://github.com/robrwo/Data-Entropy/security/advisories/GHSA-845w-rcqw-jwvv"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://metacpan.org/release/RRWO/Data-Entropy-0.010/changes"
        },
        {
          "url": "https://metacpan.org/release/RRWO/Data-Entropy-0.008/view/lib/Data/Entropy.pm#STATUS"
        },
        {
          "tags": [
            "technical-description"
          ],
          "url": "https://security.metacpan.org/docs/guides/random-data-for-security.html"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Data::Entropy versions before 0.010 for Perl read remote entropy sources over plain HTTP",
      "workarounds": [
        {
          "lang": "en",
          "value": "Deployments should not use the RandomOrg or RandomnumbersInfo sources, as these are flawed.\n\nThey have been removed from Data::Entropy 0.010. (There was a change to use HTTPS to connect to these sources in version 0.009 that did not work.)\n\nNote that Data::Entropy has been deprecated since version 0.008. Users are advised to migrate to alternative solutions that use system sources of random data, such as Crypt::SysRandom, Crypt::URandom or Crypt::PRNG."
        }
      ],
      "x_generator": {
        "engine": "cpansec-cna-tool 0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9b29abf9-4ab0-4765-b253-1875cd9b441e",
    "assignerShortName": "CPANSec",
    "cveId": "CVE-2026-18536",
    "datePublished": "2026-08-01T10:35:38.392Z",
    "dateReserved": "2026-07-31T20:31:42.315Z",
    "dateUpdated": "2026-08-03T19:55:35.372Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-17583 (GCVE-0-2026-17583)

Vulnerability from cvelistv5 – Published: 2026-08-05 20:23 – Updated: 2026-08-06 13:34
VLAI
Title
Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check
Summary
The affected Thermo Fisher Applied Biosystems Genetic Analyzers are vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-08-06 13:34 UTC
CWE
Assigner
icscert CNA under the icscert root
CNA scorecard B 75/100 over 342 records in the last 180 days details
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-17583",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-08-06T13:34:47.788856Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-08-06T13:34:57.240Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Applied Biosystems 3500/3500xL Series Data Collection Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "4.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Applied Biosystems 3730/3730xL Series Data Collection Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "5.0.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Applied Biosystems SeqStudio Genetic Analyzer Data Collection Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "1.2.5",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Applied Biosystems SeqStudio Flex Series Instrument Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "1.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Applied Biosystems GeneMapper ID-X Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "1.7.3",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Applied Biosystems 3130 Series Data Collection Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "4.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ABI PRISM 3100/3100-Avant Data Collection Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ABI PRISM 310 Data Collection Software",
          "vendor": "Thermo Fisher",
          "versions": [
            {
              "lessThanOrEqual": "3.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Nathaniel Adams, Laura Gaydosh-Combs, and Kevin Dyer reported this vulnerability to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan\u003eThe affected\u003c/span\u003e\n\nThermo Fisher Applied Biosystems Genetic Analyzers are\u003cspan\u003e\u0026nbsp;vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes.\u003c/span\u003e"
            }
          ],
          "value": "The affected\n\nThermo Fisher Applied Biosystems Genetic Analyzers are\u00a0vulnerable because .fsa/.hid output files can be edited. An attacker could tamper with these files, altering DNA data and resulting in inaccurate DNA test outcomes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.3,
            "baseSeverity": "HIGH",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:N/VC:N/VI:H/VA:H/SC:N/SI:H/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-08-05T20:23:32.890Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf"
        },
        {
          "url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-26-216-01"
        },
        {
          "url": "https://www.cve.org/CVERecord?id=CVE-2026-17583"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThermo Fisher has developed security updates to address the vulnerability. The security updates implement the use of digital signatures on the instrument software that adds an extralayer of protection. Moving forward, this will help users verify that data files have not been modified.\u003c/p\u003e\u003cp\u003eApplied Biosystems 3500/3500xL Series Data Collection Software: Update to version 4.0.3\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe\"\u003ehttps://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems 3730/3730xL Series Data Collection Software: Update to version 5.0.3\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe\"\u003ehttps://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems SeqStudio Genetic Analyzer Data Collection Software: Update to version 1.2.6\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg\"\u003ehttps://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems SeqStudio Flex Series Instrument Software: Update to version 1.2.1\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg\"\u003ehttps://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg\u003c/a\u003e\u003c/p\u003e\u003cp\u003eApplied Biosystems GeneMapper ID-X Software: Update to version 1.7.4\u003cbr\u003e\u003ca href=\"https://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe\"\u003ehttps://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Thermo Fisher has developed security updates to address the vulnerability. The security updates implement the use of digital signatures on the instrument software that adds an extralayer of protection. Moving forward, this will help users verify that data files have not been modified.\n\n\n\nApplied Biosystems 3500/3500xL Series Data Collection Software: Update to version 4.0.3\n https://downloads.thermofisher.com/3500_DCS_v4.0.3_Patch/v4.0.3_Patch_Installer.exe \n\n\n\nApplied Biosystems 3730/3730xL Series Data Collection Software: Update to version 5.0.3\n https://downloads.thermofisher.com/3730xl_UDC_v5.0.3_Patch/3730xl_UDC_v5.0.3_Patch.exe \n\n\n\nApplied Biosystems SeqStudio Genetic Analyzer Data Collection Software: Update to version 1.2.6\n https://downloads.thermofisher.com/SeqStudio/1.2.6/SeqStudio-1.2.6.abpkg \n\n\n\nApplied Biosystems SeqStudio Flex Series Instrument Software: Update to version 1.2.1\n https://downloads.thermofisher.com/SeqStudioFlex/1.2.1/SeqStudioFlex-1.2.1.abpkg \n\n\n\nApplied Biosystems GeneMapper ID-X Software: Update to version 1.7.4\n https://downloads.thermofisher.com/GeneMapperID-Xv1.7.4_Patch/GMIDX_v1.7.4_Patch.exe"
        }
      ],
      "source": {
        "advisory": "ICSMA-26-216-01",
        "discovery": "EXTERNAL"
      },
      "title": "Thermo Fisher Applied Biosystems Genetic Analyzers Missing Support for Integrity Check",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eApplied Biosystems 3130 Series Data Collection Software: Product is End of Life (EoL), no update provided\u003cbr\u003eABI PRISM 3100/3100-Avant Data Collection Software: Product is End of Life (EoL), no update provided\u003cbr\u003eABI PRISM 310 Data Collection Software: Product is End of Life (EoL), no update provided\u003c/p\u003e\u003cp\u003eFor users who are unable to immediately implement all applicable security updates, Thermo Fisher Scientific recommends implementing the following interim mitigation measures until the applicable updates have been installed:\u0026nbsp;\u003c/p\u003e\u003cul\u003e\u003cli\u003eMaintain a secure chain of custody for files generated by the HID instrumentation throughout the analysis workflow.\u003c/li\u003e\u003cli\u003eStore generated files on encrypted, password-protected storage media (for example, encrypted USB drives or encrypted hard drives).\u003c/li\u003e\u003cli\u003eRestrict access to generated files to authorized personnel in accordance with your laboratory\u0027s access control policies.\u003c/li\u003e\u003cli\u003eApply the principle of least privilege by limiting user permissions on systems operating the HID instrumentation or hosting associated data analysis and secondary analysis software.\u003c/li\u003e\u003cli\u003eLeverage firewall rules and network access control lists (NACLs) to restrict internet connectivity to only trusted sources.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003eFor more information, refer to Thermo Fisher\u0027s security bulletin.\u003cbr\u003e\u003ca href=\"https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf\"\u003ehttps://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf\u003c/a\u003e\u003c/p\u003e"
            }
          ],
          "value": "Applied Biosystems 3130 Series Data Collection Software: Product is End of Life (EoL), no update provided\nABI PRISM 3100/3100-Avant Data Collection Software: Product is End of Life (EoL), no update provided\nABI PRISM 310 Data Collection Software: Product is End of Life (EoL), no update provided\n\n\n\nFor users who are unable to immediately implement all applicable security updates, Thermo Fisher Scientific recommends implementing the following interim mitigation measures until the applicable updates have been installed:\u00a0\n\n  *  Maintain a secure chain of custody for files generated by the HID instrumentation throughout the analysis workflow.\n  *  Store generated files on encrypted, password-protected storage media (for example, encrypted USB drives or encrypted hard drives).\n  *  Restrict access to generated files to authorized personnel in accordance with your laboratory\u0027s access control policies.\n  *  Apply the principle of least privilege by limiting user permissions on systems operating the HID instrumentation or hosting associated data analysis and secondary analysis software.\n  *  Leverage firewall rules and network access control lists (NACLs) to restrict internet connectivity to only trusted sources.\n\n\n\n\nFor more information, refer to Thermo Fisher\u0027s security bulletin.\n https://documents.thermofisher.com/TFS-Assets/CORP/Product-Guides/fsa_hid_bulletin.pdf"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 1.0.4"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2026-17583",
    "datePublished": "2026-08-05T20:23:32.890Z",
    "dateReserved": "2026-07-27T15:53:40.951Z",
    "dateUpdated": "2026-08-06T13:34:57.240Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-12705 (GCVE-0-2026-12705)

Vulnerability from cvelistv5 – Published: 2026-07-17 14:30 – Updated: 2026-07-17 15:25
VLAI
Title
Integrity mechanism of KNX-device FW-files can be bypassed in ABB Update Tool
Summary
Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE). This issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-07-17 15:25 UTC
CWE
  • CWE-353 - Missing support for integrity check
Assigner
ABB CNA under the icscert root
CNA scorecard C 68/100 over 15 records in the last 180 days details
Impacted products
Vendor Product Version
ABB KNX Update Tool (ABB) Affected: 0 , ≤ 2.0.175 (custom)
Create a notification for this product.
ABB KNX Update Tool (BJE) Affected: 0 , ≤ 2.0.175 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-12705",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-07-17T15:25:25.663244Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-07-17T15:25:38.129Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "KNX Update Tool (ABB)",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.0.175",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "KNX Update Tool (BJE)",
          "vendor": "ABB",
          "versions": [
            {
              "lessThanOrEqual": "2.0.175",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).\u003cp\u003eThis issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175.\u003c/p\u003e"
            }
          ],
          "value": "Missing support for integrity check vulnerability in ABB KNX Update Tool (ABB), ABB KNX Update Tool (BJE).\n\nThis issue affects KNX Update Tool (ABB): through 2.0.175; KNX Update Tool (BJE): through 2.0.175."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "NONE",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:N/PR:L/UI:N/VC:N/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing support for integrity check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-07-17T14:30:48.974Z",
        "orgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
        "shortName": "ABB"
      },
      "references": [
        {
          "url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK108472A9270\u0026LanguageCode=en\u0026DocumentPartId=pdf\u0026Action=Launch"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Integrity mechanism of KNX-device FW-files can be bypassed in ABB Update Tool",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "2b718523-d88f-4f37-9bbd-300c20644bf9",
    "assignerShortName": "ABB",
    "cveId": "CVE-2026-12705",
    "datePublished": "2026-07-17T14:30:48.974Z",
    "dateReserved": "2026-06-19T10:24:46.696Z",
    "dateUpdated": "2026-07-17T15:25:38.129Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-7574 (GCVE-0-2026-7574)

Vulnerability from cvelistv5 – Published: 2026-06-23 23:54 – Updated: 2026-06-24 13:04
VLAI
Title
Anthropic Claude Desktop Cowork VM Image Contents Not Validated Before Use
Summary
Anthropic Claude Desktop Cowork VM image handling (confirmed across v1.1348.0 through v1.2278.0, including v1.1348.0, v1.1617.0, and v1.2278.0) validates only file presence and a version marker string before booting rootfs.img, but does not verify image content integrity at time-of-use. A local attacker with unprivileged code execution as the victim macOS user can modify the VM root filesystem image and have it trusted on subsequent Cowork VM boots, enabling persistent arbitrary code execution in the VM and access to host-mounted directories. The estimated CWE mapping is CWE-353 (Missing Support for Integrity Check).
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CNA · AHA (v2.0.3)
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-06-24 13:03 UTC
CWE
  • CWE-353 - Missing support for integrity check
Assigner
AHA CNA under the mitre root
CNA scorecard – unranked: 5 records in the last 180 days, 10 needed details
References
Impacted products
Vendor Product Version
Anthropic Claude Desktop Cowork Affected: 1.1348.0 , ≤ 1.2278.0 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-7574",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-24T13:03:53.789182Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-24T13:04:11.984Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Claude Desktop Cowork",
          "vendor": "Anthropic",
          "versions": [
            {
              "lessThanOrEqual": "1.2278.0",
              "status": "affected",
              "version": "1.1348.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Todd Manning"
        },
        {
          "lang": "en",
          "type": "coordinator",
          "value": "todb of AHA!"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Anthropic Claude Desktop Cowork VM image handling (confirmed across v1.1348.0 through v1.2278.0, including v1.1348.0, v1.1617.0, and v1.2278.0) validates only file presence and a version marker string before booting rootfs.img, but does not verify image content integrity at time-of-use. A local attacker with unprivileged code execution as the victim macOS user can modify the VM root filesystem image and have it trusted on subsequent Cowork VM boots, enabling persistent arbitrary code execution in the VM and access to host-mounted directories. The estimated CWE mapping is CWE-353 (Missing Support for Integrity Check)."
            }
          ],
          "value": "Anthropic Claude Desktop Cowork VM image handling (confirmed across v1.1348.0 through v1.2278.0, including v1.1348.0, v1.1617.0, and v1.2278.0) validates only file presence and a version marker string before booting rootfs.img, but does not verify image content integrity at time-of-use. A local attacker with unprivileged code execution as the victim macOS user can modify the VM root filesystem image and have it trusted on subsequent Cowork VM boots, enabling persistent arbitrary code execution in the VM and access to host-mounted directories. The estimated CWE mapping is CWE-353 (Missing Support for Integrity Check)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 8.7,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "other": {
            "content": {
              "options": [
                {
                  "Exploitation": "poc"
                },
                {
                  "Automatable": "no"
                },
                {
                  "Technical Impact": "total"
                }
              ],
              "role": "CNA",
              "version": "2.0.3"
            },
            "type": "ssvc"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing support for integrity check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-23T23:54:21.635Z",
        "orgId": "26969f82-7e87-44d8-9cb5-f6fb926ddd43",
        "shortName": "AHA"
      },
      "references": [
        {
          "tags": [
            "related"
          ],
          "url": "https://cfp.recon.cx/recon-2026/talk/DZUQYU/"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://takeonme.org/gcves/GCVE-1337-2026-00000000000000000000000000000000000000000000000001110111111101011111111110000000000000000000000000000000000000000000000000000001010"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Anthropic Claude Desktop Cowork VM Image Contents Not Validated Before Use",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "26969f82-7e87-44d8-9cb5-f6fb926ddd43",
    "assignerShortName": "AHA",
    "cveId": "CVE-2026-7574",
    "datePublished": "2026-06-23T23:54:21.635Z",
    "dateReserved": "2026-05-01T02:06:20.230Z",
    "dateUpdated": "2026-06-24T13:04:11.984Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2026-3856 (GCVE-0-2026-3856)

Vulnerability from cvelistv5 – Published: 2026-03-17 22:20 – Updated: 2026-03-18 20:15
VLAI
Title
IBM Db2 Recovery Expert Missing Integrity Check
Summary
IBM Db2 Recovery Expert for Linux, UNIX and Windows 5.5 IF 2 could allow an attacker to modify or corrupt data due to an insecure mechanism used for verifying the integrity of the data during transmission.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-03-18 20:15 UTC
CWE
  • CWE-353 - Missing support for integrity check
Assigner
ibm CNA under the mitre root
CNA scorecard B 88/100 over 1242 records in the last 180 days details
References
URL Tags
https://www.ibm.com/support/pages/node/7266272 vendor-advisorypatch
Impacted products
Vendor Product Version
IBM Db2 Recovery Expert Affected: 5.5 IF 2
    cpe:2.3:a:ibm:db2_recovery_expert:5.5:if2:*:*:*:windows:*:*
    cpe:2.3:a:ibm:db2_recovery_expert:5.5:if2:*:*:*:unix:*:*
    cpe:2.3:a:ibm:db2_recovery_expert:5.5:if2:*:*:*:linux:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-3856",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-03-18T20:15:02.658665Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-18T20:15:13.762Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "cpes": [
            "cpe:2.3:a:ibm:db2_recovery_expert:5.5:if2:*:*:*:windows:*:*",
            "cpe:2.3:a:ibm:db2_recovery_expert:5.5:if2:*:*:*:unix:*:*",
            "cpe:2.3:a:ibm:db2_recovery_expert:5.5:if2:*:*:*:linux:*:*"
          ],
          "defaultStatus": "unaffected",
          "product": "Db2 Recovery Expert",
          "vendor": "IBM",
          "versions": [
            {
              "status": "affected",
              "version": "5.5 IF 2"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "IBM Db2 Recovery Expert for Linux, UNIX and Windows 5.5 IF 2 could allow an attacker to modify or corrupt data due to an insecure mechanism used for verifying the integrity of the data during transmission.\u003cbr\u003e"
            }
          ],
          "value": "IBM Db2 Recovery Expert for Linux, UNIX and Windows 5.5 IF 2 could allow an attacker to modify or corrupt data due to an insecure mechanism used for verifying the integrity of the data during transmission."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing support for integrity check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-03-17T22:22:43.825Z",
        "orgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
        "shortName": "ibm"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://www.ibm.com/support/pages/node/7266272"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cdiv\u003e\u003cp\u003eUpgrade to DB2 Recovery Expert for Linux, Unix and Windows v5.5.0.1 Interim Fix 8 available on Fix Central\u0026nbsp;\u003ca href=\"https://www.ibm.com/support/fixcentral/swg/selectFixes?parent=ibm%7EInformation%20Management\u0026amp;product=ibm/Information+Management/DB2+Recovery+Expert+for+Linux+UNIX+and+Windows\u0026amp;release=5.5.0.1\u0026amp;platform=All\u0026amp;function=all\" rel=\"nofollow\"\u003ehere\u003c/a\u003e.\u003c/p\u003e\u003c/div\u003e"
            }
          ],
          "value": "Upgrade to DB2 Recovery Expert for Linux, Unix and Windows v5.5.0.1 Interim Fix 8 available on Fix Central\u00a0 here https://www.ibm.com/support/fixcentral/swg/selectFixes ."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "IBM Db2 Recovery Expert Missing Integrity Check",
      "x_generator": {
        "engine": "Vulnogram 1.0.1"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9a959283-ebb5-44b6-b705-dcc2bbced522",
    "assignerShortName": "ibm",
    "cveId": "CVE-2026-3856",
    "datePublished": "2026-03-17T22:20:14.968Z",
    "dateReserved": "2026-03-09T20:48:18.685Z",
    "dateUpdated": "2026-03-18T20:15:13.762Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-48811 (GCVE-0-2025-48811)

Vulnerability from cvelistv5 – Published: 2025-07-08 16:57 – Updated: 2026-02-26 18:27
VLAI
Title
Windows Virtualization-Based Security (VBS) Enclave Elevation of Privilege Vulnerability
Summary
Missing support for integrity check in Windows Virtualization-Based Security (VBS) Enclave allows an authorized attacker to elevate privileges locally.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-09 04:01 UTC
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
microsoft CNA under the mitre root
CNA scorecard B 82/100 over 3924 records in the last 180 days details
References
Impacted products
Vendor Product Version
Microsoft Windows 10 Version 1507 Affected: 10.0.10240.0 , < 10.0.10240.21073 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1607 Affected: 10.0.14393.0 , < 10.0.14393.8246 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1809 Affected: 10.0.17763.0 , < 10.0.17763.7558 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 21H2 Affected: 10.0.19044.0 , < 10.0.19044.6093 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 22H2 Affected: 10.0.19045.0 , < 10.0.19045.6093 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H2 Affected: 10.0.22621.0 , < 10.0.22621.5624 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H3 Affected: 10.0.22631.0 , < 10.0.22631.5624 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 23H2 Affected: 10.0.22631.0 , < 10.0.22631.5624 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 24H2 Affected: 10.0.26100.0 , < 10.0.26100.4652 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 Affected: 10.0.14393.0 , < 10.0.14393.8246 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 (Server Core installation) Affected: 10.0.14393.0 , < 10.0.14393.8246 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 Affected: 10.0.17763.0 , < 10.0.17763.7558 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 (Server Core installation) Affected: 10.0.17763.0 , < 10.0.17763.7558 (custom)
Create a notification for this product.
Microsoft Windows Server 2022 Affected: 10.0.20348.0 , < 10.0.20348.3932 (custom)
Create a notification for this product.
Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) Affected: 10.0.25398.0 , < 10.0.25398.1732 (custom)
Create a notification for this product.
Microsoft Windows Server 2025 Affected: 10.0.26100.0 , < 10.0.26100.4652 (custom)
Create a notification for this product.
Microsoft Windows Server 2025 (Server Core installation) Affected: 10.0.26100.0 , < 10.0.26100.4652 (custom)
Create a notification for this product.
Date Public
2025-07-08 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48811",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-09T04:01:43.158520Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T18:27:40.717Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1507",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.10240.21073",
              "status": "affected",
              "version": "10.0.10240.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1607",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.8246",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7558",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19044.6093",
              "status": "affected",
              "version": "10.0.19044.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19045.6093",
              "status": "affected",
              "version": "10.0.19045.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22621.5624",
              "status": "affected",
              "version": "10.0.22621.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 22H3",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.5624",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 23H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.5624",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 24H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.4652",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.8246",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.8246",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7558",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7558",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.20348.3932",
              "status": "affected",
              "version": "10.0.20348.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.25398.1732",
              "status": "affected",
              "version": "10.0.25398.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2025",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.4652",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2025 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.4652",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.17763.7558",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.7558",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.7558",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.20348.3932",
                  "versionStartIncluding": "10.0.20348.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.19044.6093",
                  "versionStartIncluding": "10.0.19044.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22621.5624",
                  "versionStartIncluding": "10.0.22621.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.19045.6093",
                  "versionStartIncluding": "10.0.19045.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.26100.4652",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22631.5624",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22631.5624",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.25398.1732",
                  "versionStartIncluding": "10.0.25398.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_24H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.26100.4652",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.26100.4652",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.10240.21073",
                  "versionStartIncluding": "10.0.10240.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.14393.8246",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.8246",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.8246",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2025-07-08T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Missing support for integrity check in Windows Virtualization-Based Security (VBS) Enclave allows an authorized attacker to elevate privileges locally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353: Missing Support for Integrity Check",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-13T19:07:17.419Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Windows Virtualization-Based Security (VBS) Enclave Elevation of Privilege Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-48811"
        }
      ],
      "title": "Windows Virtualization-Based Security (VBS) Enclave Elevation of Privilege Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2025-48811",
    "datePublished": "2025-07-08T16:57:42.075Z",
    "dateReserved": "2025-05-26T17:09:49.056Z",
    "dateUpdated": "2026-02-26T18:27:40.717Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-48803 (GCVE-0-2025-48803)

Vulnerability from cvelistv5 – Published: 2025-07-08 16:57 – Updated: 2026-02-13 19:07
VLAI
Title
Windows Virtualization-Based Security (VBS) Elevation of Privilege Vulnerability
Summary
Missing support for integrity check in Windows Virtualization-Based Security (VBS) Enclave allows an authorized attacker to elevate privileges locally.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-07-08 19:19 UTC
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
microsoft CNA under the mitre root
CNA scorecard B 82/100 over 3924 records in the last 180 days details
References
Impacted products
Vendor Product Version
Microsoft Windows 10 Version 1507 Affected: 10.0.10240.0 , < 10.0.10240.21073 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1607 Affected: 10.0.14393.0 , < 10.0.14393.8246 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 1809 Affected: 10.0.17763.0 , < 10.0.17763.7558 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 21H2 Affected: 10.0.19044.0 , < 10.0.19044.6093 (custom)
Create a notification for this product.
Microsoft Windows 10 Version 22H2 Affected: 10.0.19045.0 , < 10.0.19045.6093 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H2 Affected: 10.0.22621.0 , < 10.0.22621.5624 (custom)
Create a notification for this product.
Microsoft Windows 11 version 22H3 Affected: 10.0.22631.0 , < 10.0.22631.5624 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 23H2 Affected: 10.0.22631.0 , < 10.0.22631.5624 (custom)
Create a notification for this product.
Microsoft Windows 11 Version 24H2 Affected: 10.0.26100.0 , < 10.0.26100.4652 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 Affected: 10.0.14393.0 , < 10.0.14393.8246 (custom)
Create a notification for this product.
Microsoft Windows Server 2016 (Server Core installation) Affected: 10.0.14393.0 , < 10.0.14393.8246 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 Affected: 10.0.17763.0 , < 10.0.17763.7558 (custom)
Create a notification for this product.
Microsoft Windows Server 2019 (Server Core installation) Affected: 10.0.17763.0 , < 10.0.17763.7558 (custom)
Create a notification for this product.
Microsoft Windows Server 2022 Affected: 10.0.20348.0 , < 10.0.20348.3932 (custom)
Create a notification for this product.
Microsoft Windows Server 2022, 23H2 Edition (Server Core installation) Affected: 10.0.25398.0 , < 10.0.25398.1732 (custom)
Create a notification for this product.
Microsoft Windows Server 2025 Affected: 10.0.26100.0 , < 10.0.26100.4652 (custom)
Create a notification for this product.
Microsoft Windows Server 2025 (Server Core installation) Affected: 10.0.26100.0 , < 10.0.26100.4652 (custom)
Create a notification for this product.
Date Public
2025-07-08 07:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48803",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-07-08T19:19:22.205726Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-07-08T19:45:50.528Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1507",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.10240.21073",
              "status": "affected",
              "version": "10.0.10240.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1607",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.8246",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 1809",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7558",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 21H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19044.6093",
              "status": "affected",
              "version": "10.0.19044.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "32-bit Systems",
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 10 Version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.19045.6093",
              "status": "affected",
              "version": "10.0.19045.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 version 22H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22621.5624",
              "status": "affected",
              "version": "10.0.22621.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems"
          ],
          "product": "Windows 11 version 22H3",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.5624",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 23H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.22631.5624",
              "status": "affected",
              "version": "10.0.22631.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "ARM64-based Systems",
            "x64-based Systems"
          ],
          "product": "Windows 11 Version 24H2",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.4652",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.8246",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2016 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.14393.8246",
              "status": "affected",
              "version": "10.0.14393.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7558",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2019 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.17763.7558",
              "status": "affected",
              "version": "10.0.17763.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.20348.3932",
              "status": "affected",
              "version": "10.0.20348.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2022, 23H2 Edition (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.25398.1732",
              "status": "affected",
              "version": "10.0.25398.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2025",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.4652",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        },
        {
          "platforms": [
            "x64-based Systems"
          ],
          "product": "Windows Server 2025 (Server Core installation)",
          "vendor": "Microsoft",
          "versions": [
            {
              "lessThan": "10.0.26100.4652",
              "status": "affected",
              "version": "10.0.26100.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1809:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.17763.7558",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.7558",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2019:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.17763.7558",
                  "versionStartIncluding": "10.0.17763.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2022:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.20348.3932",
                  "versionStartIncluding": "10.0.20348.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_21H2:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.19044.6093",
                  "versionStartIncluding": "10.0.19044.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_22H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22621.5624",
                  "versionStartIncluding": "10.0.22621.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_22H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.19045.6093",
                  "versionStartIncluding": "10.0.19045.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.26100.4652",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.22631.5624",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_23H2:*:*:*:*:*:*:x64:*",
                  "versionEndExcluding": "10.0.22631.5624",
                  "versionStartIncluding": "10.0.22631.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_23h2:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.25398.1732",
                  "versionStartIncluding": "10.0.25398.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_11_24H2:*:*:*:*:*:*:arm64:*",
                  "versionEndExcluding": "10.0.26100.4652",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2025:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.26100.4652",
                  "versionStartIncluding": "10.0.26100.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1507:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.10240.21073",
                  "versionStartIncluding": "10.0.10240.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_10_1607:*:*:*:*:*:*:x86:*",
                  "versionEndExcluding": "10.0.14393.8246",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.8246",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:o:microsoft:windows_server_2016:*:*:*:*:*:*:*:*",
                  "versionEndExcluding": "10.0.14393.8246",
                  "versionStartIncluding": "10.0.14393.0",
                  "vulnerable": true
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ]
        }
      ],
      "datePublic": "2025-07-08T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en-US",
          "value": "Missing support for integrity check in Windows Virtualization-Based Security (VBS) Enclave allows an authorized attacker to elevate privileges locally."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 6.7,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H/E:U/RL:O/RC:C",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en-US",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353: Missing Support for Integrity Check",
              "lang": "en-US",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-13T19:07:13.164Z",
        "orgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
        "shortName": "microsoft"
      },
      "references": [
        {
          "name": "Windows Virtualization-Based Security (VBS) Elevation of Privilege Vulnerability",
          "tags": [
            "vendor-advisory",
            "patch"
          ],
          "url": "https://msrc.microsoft.com/update-guide/vulnerability/CVE-2025-48803"
        }
      ],
      "title": "Windows Virtualization-Based Security (VBS) Elevation of Privilege Vulnerability"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "f38d906d-7342-40ea-92c1-6c4a2c6478c8",
    "assignerShortName": "microsoft",
    "cveId": "CVE-2025-48803",
    "datePublished": "2025-07-08T16:57:37.872Z",
    "dateReserved": "2025-05-26T17:09:49.055Z",
    "dateUpdated": "2026-02-13T19:07:13.164Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-48500 (GCVE-0-2025-48500)

Vulnerability from cvelistv5 – Published: 2025-08-13 14:46 – Updated: 2026-02-26 17:48
VLAI
Title
BIG-IP APM VPN web client for macOS vulnerability
Summary
A missing file integrity check vulnerability exists on MacOS F5 VPN browser client installer that may allow a local, authenticated attacker with access to the local file system to replace it with a malicious package installer.  Note: Software versions which have reached End of Technical Support (EoTS) are not evaluated.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-08-14 03:56 UTC
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
f5 CNA under the mitre root
CNA scorecard B 84/100 over 87 records in the last 180 days details
References
Impacted products
Vendor Product Version
F5 BIG-IP Edge Client Affected: 7.2.4 , < 7.2.5.3 (custom)
Create a notification for this product.
F5 BIG-IP Affected: 17.5.0 , < * (custom)
Affected: 17.1.0 , < * (custom)
Affected: 16.1.0 , < * (custom)
Affected: 15.1.0 , < * (custom)
Create a notification for this product.
Date Public
2025-08-13 14:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-48500",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-14T03:56:00.540232Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-26T17:48:40.742Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "modules": [
            "BIG-IP Edge Client for MacOS"
          ],
          "platforms": [
            "MacOS"
          ],
          "product": "BIG-IP Edge Client",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "7.2.5.3",
              "status": "affected",
              "version": "7.2.4",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "modules": [
            "APM"
          ],
          "product": "BIG-IP",
          "vendor": "F5",
          "versions": [
            {
              "lessThan": "*",
              "status": "affected",
              "version": "17.5.0",
              "versionType": "custom"
            },
            {
              "lessThan": "*",
              "status": "affected",
              "version": "17.1.0",
              "versionType": "custom"
            },
            {
              "lessThan": "*",
              "status": "affected",
              "version": "16.1.0",
              "versionType": "custom"
            },
            {
              "lessThan": "*",
              "status": "affected",
              "version": "15.1.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "F5 acknowledges Adwiteeya Agrawal of Snapchat, Inc for bringing this issue to our attention and following the highest standards of coordinated disclosure."
        }
      ],
      "datePublic": "2025-08-13T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA missing file integrity check vulnerability exists on MacOS F5 VPN browser client installer that may allow a local, authenticated attacker with access to the local file system to replace it with a malicious package installer.\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;\u003c/span\u003e\nNote: Software versions which have reached End of Technical Support (EoTS) are not evaluated.\n\n\u003c/span\u003e"
            }
          ],
          "value": "A missing file integrity check vulnerability exists on MacOS F5 VPN browser client installer that may allow a local, authenticated attacker with access to the local file system to replace it with a malicious package installer.\u00a0\nNote: Software versions which have reached End of Technical Support (EoTS) are not evaluated."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 7,
            "baseSeverity": "HIGH",
            "privilegesRequired": "LOW",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:L/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353: Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-13T14:46:54.682Z",
        "orgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
        "shortName": "f5"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://my.f5.com/manage/s/article/K000151782"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "BIG-IP APM VPN web client for macOS vulnerability",
      "x_generator": {
        "engine": "F5 SIRTBot v1.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9dacffd4-cb11-413f-8451-fbbfd4ddc0ab",
    "assignerShortName": "f5",
    "cveId": "CVE-2025-48500",
    "datePublished": "2025-08-13T14:46:54.682Z",
    "dateReserved": "2025-07-29T17:12:25.024Z",
    "dateUpdated": "2026-02-26T17:48:40.742Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-15364 (GCVE-0-2025-15364)

Vulnerability from cvelistv5 – Published: 2026-01-06 01:50 – Updated: 2026-04-08 16:33
VLAI
Title
Download Manager <= 3.3.40 - Unauthenticated Limited Privilege Escalation via updatePassword
Summary
The Download Manager plugin for WordPress is vulnerable to privilege escalation via account takeover in all versions up to, and including, 3.3.40. This is due to the plugin not properly validating a user's identity prior to updating their details like password. This makes it possible for unauthenticated attackers to change user's passwords, except administrators, and leverage that to gain access to their account.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-06 14:20 UTC
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
Wordfence CNA under the mitre root
CNA scorecard C 65/100 over 2187 records in the last 180 days details
Impacted products
Vendor Product Version
codename065 Download Manager Affected: 0 , ≤ 3.3.40 (semver)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-15364",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-06T14:20:09.826991Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-06T18:57:23.139Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Download Manager",
          "vendor": "codename065",
          "versions": [
            {
              "lessThanOrEqual": "3.3.40",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Drew Webber"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The Download Manager plugin for WordPress is vulnerable to privilege escalation via account takeover in all versions up to, and including, 3.3.40. This is due to the plugin not properly validating a user\u0027s identity prior to updating their details like password. This makes it possible for unauthenticated attackers to change user\u0027s passwords, except administrators, and leverage that to gain access to their account."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "baseScore": 7.3,
            "baseSeverity": "HIGH",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-04-08T16:33:45.276Z",
        "orgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
        "shortName": "Wordfence"
      },
      "references": [
        {
          "url": "https://www.wordfence.com/threat-intel/vulnerabilities/id/067031e8-6aa8-451c-a318-b1848c7a4f92?source=cve"
        },
        {
          "url": "https://plugins.trac.wordpress.org/browser/download-manager/tags/3.3.40/src/__/Crypt.php#L18"
        },
        {
          "url": "https://plugins.trac.wordpress.org/changeset/3431915/download-manager#file7"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2025-12-30T14:38:48.000Z",
          "value": "Vendor Notified"
        },
        {
          "lang": "en",
          "time": "2026-01-05T13:11:34.000Z",
          "value": "Disclosed"
        }
      ],
      "title": "Download Manager \u003c= 3.3.40 - Unauthenticated Limited Privilege Escalation via updatePassword"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "b15e7b5b-3da4-40ae-a43c-f7aa60e62599",
    "assignerShortName": "Wordfence",
    "cveId": "CVE-2025-15364",
    "datePublished": "2026-01-06T01:50:12.652Z",
    "dateReserved": "2025-12-30T14:21:41.555Z",
    "dateUpdated": "2026-04-08T16:33:45.276Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-10010 (GCVE-0-2025-10010)

Vulnerability from cvelistv5 – Published: 2026-02-24 14:13 – Updated: 2026-03-12 23:06
VLAI
Title
Integrity Validation Bypass in CryptoPro Secure Disk for BitLocker
Summary
The CPSD CryptoPro Secure Disk application boots a small Linux operating system to perform user authentication before using BitLocker to decrypt the Windows partition. The system is located on a separate unencrypted partition which can be reached by anyone with access to the hard disk. Multiple checks are performed to validate the integrity of the Linux operating system and the CryptoPro Secure Disk application files. When files are changed an error is shown on system start. One of the checks is the Linux kernel's Integrity Measurement Architecture (IMA). It was identified that configuration files are not validated by the IMA and can then (if not checked by other measures) be changed. This allows an attacker to execute arbitrary code in the context of the root user and enables an attacker to e.g., plant a backdoor and access data during execution.
SSVC
Exploitation: poc Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-02-24 14:50 UTC
CWE
  • CWE-353 - Missing Support for Integrity Check
Assigner
SEC-VLab CNA under the mitre root
CNA scorecard B 81/100 over 22 records in the last 180 days details
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "PHYSICAL",
              "availabilityImpact": "HIGH",
              "baseScore": 6.8,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2025-10010",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-02-24T14:50:57.464414Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-02-24T14:53:28.726Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2026-03-12T23:06:38.952Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2026/Mar/0"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CryptoPro Secure Disk for BitLocker",
          "vendor": "CPSD IT SERVICES GMBH",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c7.6.6 / 7.7.1"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Gorazd Jank, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Stefan Viehb\u00f6ck, SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The CPSD CryptoPro Secure Disk application boots a small Linux operating system to perform user authentication before using BitLocker to decrypt the Windows partition. The system is located on a separate unencrypted partition which can be reached by anyone with access to the hard disk.\u003cbr\u003e\u003cbr\u003eMultiple checks are performed to validate the integrity of the Linux operating system and the CryptoPro Secure Disk application files. When files are changed an error is shown on system start. One of the checks is the Linux kernel\u0027s Integrity Measurement Architecture (IMA). It was identified that configuration files are not validated by the IMA and can then (if not checked by other measures) be changed. This allows an attacker to execute arbitrary code in the context of the root user and enables an attacker to e.g., plant a backdoor and access data during execution.\u003cbr\u003e"
            }
          ],
          "value": "The CPSD CryptoPro Secure Disk application boots a small Linux operating system to perform user authentication before using BitLocker to decrypt the Windows partition. The system is located on a separate unencrypted partition which can be reached by anyone with access to the hard disk.\n\nMultiple checks are performed to validate the integrity of the Linux operating system and the CryptoPro Secure Disk application files. When files are changed an error is shown on system start. One of the checks is the Linux kernel\u0027s Integrity Measurement Architecture (IMA). It was identified that configuration files are not validated by the IMA and can then (if not checked by other measures) be changed. This allows an attacker to execute arbitrary code in the context of the root user and enables an attacker to e.g., plant a backdoor and access data during execution."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-75",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-75 Manipulating Writeable Configuration Files"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-353",
              "description": "CWE-353 Missing Support for Integrity Check",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-24T14:13:29.155Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/cpsd"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The vendor provides a patch with version 7.6.6 / 7.7.1. Encryption is activated by default starting with version 7.7.\u003cbr\u003e"
            }
          ],
          "value": "The vendor provides a patch with version 7.6.6 / 7.7.1. Encryption is activated by default starting with version 7.7."
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Integrity Validation Bypass in CryptoPro Secure Disk for BitLocker",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Encryption of the PBA partition is possible (since version 7.6.0) and prevents changing of the configuration files. Encryption can be activated via \"Client Security/Verschiedenes/PBA Linux Partition verschl\u00fcsseln\". Clients will be informed by the vendor about the risk if the PBA partition is not encrypted.\u003cbr\u003e"
            }
          ],
          "value": "Encryption of the PBA partition is possible (since version 7.6.0) and prevents changing of the configuration files. Encryption can be activated via \"Client Security/Verschiedenes/PBA Linux Partition verschl\u00fcsseln\". Clients will be informed by the vendor about the risk if the PBA partition is not encrypted."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-10010",
    "datePublished": "2026-02-24T14:13:29.155Z",
    "dateReserved": "2025-09-05T08:13:43.528Z",
    "dateUpdated": "2026-03-12T23:06:38.952Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

Mitigation
Architecture and Design

Add an appropriately sized checksum to the protocol, ensuring that data received may be simply validated before it is parsed and used.

Mitigation
Implementation

Ensure that the checksums present in the protocol design are properly implemented and added to each message before it is sent.

CAPEC-13: Subverting Environment Variable Values

The adversary directly or indirectly modifies environment variables used by or controlling the target software. The adversary's goal is to cause the target software to deviate from its expected operation in a manner that benefits the adversary.

CAPEC-14: Client-side Injection-induced Buffer Overflow

This type of attack exploits a buffer overflow vulnerability in targeted client software through injection of malicious content from a custom-built hostile service. This hostile service is created to deliver the correct content to the client software. For example, if the client-side application is a browser, the service will host a webpage that the browser loads.

CAPEC-389: Content Spoofing Via Application API Manipulation

An attacker manipulates either egress or ingress data from a client within an application framework in order to change the content of messages. Performing this attack allows the attacker to manipulate content in such a way as to produce messages or content that look authentic but may contain deceptive links, spam-like content, or links to the attackers' code. In general, content-spoofing within an application API can be employed to stage many different types of attacks varied based on the attackers' intent. The techniques require use of specialized software that allow the attacker to use adversary-in-the-middle (CAPEC-94) communications between the web browser and the remote system.

CAPEC-39: Manipulating Opaque Client-based Data Tokens

In circumstances where an application holds important data client-side in tokens (cookies, URLs, data files, and so forth) that data can be manipulated. If client or server-side application components reinterpret that data as authentication tokens or data (such as store item pricing or wallet information) then even opaquely manipulating that data may bear fruit for an Attacker. In this pattern an attacker undermines the assumption that client side tokens have been adequately protected from tampering through use of encryption or obfuscation.

CAPEC-665: Exploitation of Thunderbolt Protection Flaws

An adversary leverages a firmware weakness within the Thunderbolt protocol, on a computing device to manipulate Thunderbolt controller firmware in order to exploit vulnerabilities in the implementation of authorization and verification schemes within Thunderbolt protection mechanisms. Upon gaining physical access to a target device, the adversary conducts high-level firmware manipulation of the victim Thunderbolt controller SPI (Serial Peripheral Interface) flash, through the use of a SPI Programing device and an external Thunderbolt device, typically as the target device is booting up. If successful, this allows the adversary to modify memory, subvert authentication mechanisms, spoof identities and content, and extract data and memory from the target device. Currently 7 major vulnerabilities exist within Thunderbolt protocol with 9 attack vectors as noted in the Execution Flow.

CAPEC-74: Manipulating State

The adversary modifies state information maintained by the target software or causes a state transition in hardware. If successful, the target will use this tainted state and execute in an unintended manner.

State management is an important function within a software application. User state maintained by the application can include usernames, payment information, browsing history as well as application-specific contents such as items in a shopping cart. Manipulating user state can be employed by an adversary to elevate privilege, conduct fraudulent transactions or otherwise modify the flow of the application to derive certain benefits.

If there is a hardware logic error in a finite state machine, the adversary can use this to put the system in an undefined state which could cause a denial of service or exposure of secure data.

CAPEC-75: Manipulating Writeable Configuration Files

Generally these are manually edited files that are not in the preview of the system administrators, any ability on the attackers' behalf to modify these files, for example in a CVS repository, gives unauthorized access directly to the application, the same as authorized users.