CWE-248
AllowedUncaught Exception
Abstraction: Base · Status: Draft
An exception is thrown from a function, but it is not caught.
655 vulnerabilities reference this CWE, most recent first.
CVE-2019-6828 (GCVE-0-2019-6828)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:59 – Updated: 2024-08-04 20:31- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|
| Schneider Electric SE | Modicon M340 |
Affected:
firmware version prior to V3.10
|
|
| Schneider Electric SE | Modicon Premium |
Affected:
all versions
|
|
| Schneider Electric SE | Modicon Quantum |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.247Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:59:33.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6828",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists Modicon M580 (firmware version prior to V2.90), Modicon M340 (firmware version prior to V3.10), Modicon Premium (all versions), and Modicon Quantum (all versions), which could cause a possible denial of service when reading specific coils and registers in the controller over Modbus."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6828",
"datePublished": "2019-09-17T19:59:33.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.247Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6809 (GCVE-0-2019-6809)
Vulnerability from cvelistv5 – Published: 2019-09-17 19:50 – Updated: 2024-08-04 20:31- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| https://www.schneider-electric.com/en/download/do… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Schneider Electric SE | Modicon M580 |
Affected:
firmware version prior to V2.90
|
|
| Schneider Electric SE | Modicon M340 |
Affected:
firmware version prior to V3.10
|
|
| Schneider Electric SE | Modicon Premium |
Affected:
all versions
|
|
| Schneider Electric SE | Modicon Quantum |
Affected:
all versions
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:31:04.229Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V2.90"
}
]
},
{
"product": "Modicon M340",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "firmware version prior to V3.10"
}
]
},
{
"product": "Modicon Premium",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
},
{
"product": "Modicon Quantum",
"vendor": "Schneider Electric SE",
"versions": [
{
"status": "affected",
"version": "all versions"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-09-17T19:50:29.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2019-6809",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V2.90"
}
]
}
},
{
"product_name": "Modicon M340",
"version": {
"version_data": [
{
"version_value": "firmware version prior to V3.10"
}
]
}
},
{
"product_name": "Modicon Premium",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
},
{
"product_name": "Modicon Quantum",
"version": {
"version_data": [
{
"version_value": "all versions"
}
]
}
}
]
},
"vendor_name": "Schneider Electric SE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware versions prior to V2.90), Modicon M340 (firmware versions prior to V3.10), Modicon Premium (all versions), Modicon Quantum (all versions), which could cause a possible denial of service when reading invalid data from the controller."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "CONFIRM",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2019-6809",
"datePublished": "2019-09-17T19:50:29.000Z",
"dateReserved": "2019-01-25T00:00:00.000Z",
"dateUpdated": "2024-08-04T20:31:04.229Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2019-6575 (GCVE-0-2019-6575)
Vulnerability from cvelistv5 – Published: 2019-04-17 13:40 – Updated: 2026-06-03 13:25- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_MISC |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T20:23:22.041Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-6575",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-03T13:20:11.329732Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T13:25:38.925Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC CP 443-1 OPC UA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.7"
}
]
},
{
"product": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 4"
}
]
},
{
"product": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 4"
}
]
},
{
"product": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 4"
}
]
},
{
"product": "SIMATIC IPC DiagMonitor",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V5.1.3"
}
]
},
{
"product": "SIMATIC NET PC Software V13",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC NET PC Software V14",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP1 Update 14"
}
]
},
{
"product": "SIMATIC NET PC Software V15",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions"
}
]
},
{
"product": "SIMATIC RF188C",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.1.0"
}
]
},
{
"product": "SIMATIC RF600R family",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.2.1"
}
]
},
{
"product": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003e= V2.5 \u003c V2.6.1"
}
]
},
{
"product": "SIMATIC S7-1500 Software Controller",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions between V2.5 (including) and V2.7 (excluding)"
}
]
},
{
"product": "SIMATIC WinCC OA",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.15 P018"
}
]
},
{
"product": "SIMATIC WinCC Runtime Advanced",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V15.1 Upd 4"
}
]
},
{
"product": "SINEC NMS",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V1.0 SP1"
}
]
},
{
"product": "SINEMA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V14 SP2"
}
]
},
{
"product": "SINUMERIK OPC UA Server",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.1"
}
]
},
{
"product": "TeleControl Server Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V3.1.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-10T11:16:36.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2019-6575",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC CP 443-1 OPC UA",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.7"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 4"
}
]
}
},
{
"product_name": "SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 4"
}
]
}
},
{
"product_name": "SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 4"
}
]
}
},
{
"product_name": "SIMATIC IPC DiagMonitor",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V5.1.3"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V13",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V14",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP1 Update 14"
}
]
}
},
{
"product_name": "SIMATIC NET PC Software V15",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "SIMATIC RF188C",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.1.0"
}
]
}
},
{
"product_name": "SIMATIC RF600R family",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.2.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants)",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.5 \u003c V2.6.1"
}
]
}
},
{
"product_name": "SIMATIC S7-1500 Software Controller",
"version": {
"version_data": [
{
"version_value": "All versions between V2.5 (including) and V2.7 (excluding)"
}
]
}
},
{
"product_name": "SIMATIC WinCC OA",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.15 P018"
}
]
}
},
{
"product_name": "SIMATIC WinCC Runtime Advanced",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V15.1 Upd 4"
}
]
}
},
{
"product_name": "SINEC NMS",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V1.0 SP1"
}
]
}
},
{
"product_name": "SINEMA Server",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V14 SP2"
}
]
}
},
{
"product_name": "SINUMERIK OPC UA Server",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.1"
}
]
}
},
{
"product_name": "TeleControl Server Basic",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.1.1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC CP 443-1 OPC UA (All versions), SIMATIC ET 200SP Open Controller CPU 1515SP PC2 (incl. SIPLUS variants) (All versions \u003c V2.7), SIMATIC HMI Comfort Outdoor Panels 7\" \u0026 15\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI Comfort Panels 4\" - 22\" (incl. SIPLUS variants) (All versions \u003c V15.1 Upd 4), SIMATIC HMI KTP Mobile Panels KTP400F, KTP700, KTP700F, KTP900 and KTP900F (All versions \u003c V15.1 Upd 4), SIMATIC IPC DiagMonitor (All versions \u003c V5.1.3), SIMATIC NET PC Software V13 (All versions), SIMATIC NET PC Software V14 (All versions \u003c V14 SP1 Update 14), SIMATIC NET PC Software V15 (All versions), SIMATIC RF188C (All versions \u003c V1.1.0), SIMATIC RF600R family (All versions \u003c V3.2.1), SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) (All versions \u003e= V2.5 \u003c V2.6.1), SIMATIC S7-1500 Software Controller (All versions between V2.5 (including) and V2.7 (excluding)), SIMATIC WinCC OA (All versions \u003c V3.15 P018), SIMATIC WinCC Runtime Advanced (All versions \u003c V15.1 Upd 4), SINEC NMS (All versions \u003c V1.0 SP1), SINEMA Server (All versions \u003c V14 SP2), SINUMERIK OPC UA Server (All versions \u003c V2.1), TeleControl Server Basic (All versions \u003c V3.1.1). Specially crafted network packets sent to affected devices on port 4840/tcp could allow an unauthenticated remote attacker to cause a denial of service condition of the OPC communication or crash the device. The security vulnerability could be exploited by an attacker with network access to the affected systems. Successful exploitation requires no system privileges and no user interaction. An attacker could use the vulnerability to compromise availability of the OPC communication."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-307392.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2019-6575",
"datePublished": "2019-04-17T13:40:24.000Z",
"dateReserved": "2019-01-22T00:00:00.000Z",
"dateUpdated": "2026-06-03T13:25:38.925Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
CVE-2018-11466 (GCVE-0-2018-11466)
Vulnerability from cvelistv5 – Published: 2018-12-12 16:00 – Updated: 2024-08-05 08:10- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/106185 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 |
Affected:
SINUMERIK 808D V4.7 : All versions
Affected: SINUMERIK 808D V4.8 : All versions Affected: SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1 Affected: SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5 Affected: SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.337Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106185",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106185"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "SINUMERIK 808D V4.7 : All versions"
},
{
"status": "affected",
"version": "SINUMERIK 808D V4.8 : All versions"
},
{
"status": "affected",
"version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
},
{
"status": "affected",
"version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
},
{
"status": "affected",
"version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
}
]
}
],
"datePublic": "2018-12-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-14T10:57:02.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "106185",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106185"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-11466",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version": {
"version_data": [
{
"version_value": "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value": "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
},
{
"version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
},
{
"version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). Specially crafted network packets sent to port 102/tcp (ISO-TSAP) could allow a remote attacker to either cause a Denial-of-Service condition of the integrated software firewall or allow to execute code in the context of the software firewall. The security vulnerability could be exploited by an attacker with network access to the affected systems on port 102/tcp. Successful exploitation requires no user privileges and no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106185",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106185"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11466",
"datePublished": "2018-12-12T16:00:00.000Z",
"dateReserved": "2018-05-25T00:00:00.000Z",
"dateUpdated": "2024-08-05T08:10:14.337Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-11465 (GCVE-0-2018-11465)
Vulnerability from cvelistv5 – Published: 2018-12-12 16:00 – Updated: 2024-08-05 08:10- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/106185 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 |
Affected:
SINUMERIK 808D V4.7 : All versions
Affected: SINUMERIK 808D V4.8 : All versions Affected: SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1 Affected: SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5 Affected: SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.330Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106185",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106185"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "SINUMERIK 808D V4.7 : All versions"
},
{
"status": "affected",
"version": "SINUMERIK 808D V4.8 : All versions"
},
{
"status": "affected",
"version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
},
{
"status": "affected",
"version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
},
{
"status": "affected",
"version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
}
]
}
],
"datePublic": "2018-12-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-14T10:57:02.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "106185",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106185"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-11465",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK 808D V4.7, SINUMERIK 808D V4.8, SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version": {
"version_data": [
{
"version_value": "SINUMERIK 808D V4.7 : All versions"
},
{
"version_value": "SINUMERIK 808D V4.8 : All versions"
},
{
"version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
},
{
"version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
},
{
"version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SINUMERIK 808D V4.7 (All versions), SINUMERIK 808D V4.8 (All versions), SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). A local attacker could use ioctl calls to do out of bounds reads, arbitrary writes, or execute code in kernel mode. The security vulnerability could be exploited by an attacker with local access to the affected systems. Successful exploitation requires user privileges but no user interaction. The vulnerability could allow an attacker to compromise confidentiality, integrity and availability of the system. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106185",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106185"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11465",
"datePublished": "2018-12-12T16:00:00.000Z",
"dateReserved": "2018-05-25T00:00:00.000Z",
"dateUpdated": "2024-08-05T08:10:14.330Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2018-11464 (GCVE-0-2018-11464)
Vulnerability from cvelistv5 – Published: 2018-12-12 16:00 – Updated: 2024-08-05 08:10- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| http://www.securityfocus.com/bid/106185 | vdb-entryx_refsource_BID |
| https://cert-portal.siemens.com/productcert/pdf/s… | x_refsource_CONFIRM |
| Vendor | Product | Version | |
|---|---|---|---|
| Siemens AG | SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8 |
Affected:
SINUMERIK 828D V4.7 : All versions < V4.7 SP6 HF1
Affected: SINUMERIK 840D sl V4.7 : All versions < V4.7 SP6 HF5 Affected: SINUMERIK 840D sl V4.8 : All versions < V4.8 SP3 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T08:10:14.565Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"name": "106185",
"tags": [
"vdb-entry",
"x_refsource_BID",
"x_transferred"
],
"url": "http://www.securityfocus.com/bid/106185"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"vendor": "Siemens AG",
"versions": [
{
"status": "affected",
"version": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
},
{
"status": "affected",
"version": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
},
{
"status": "affected",
"version": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
}
]
}
],
"datePublic": "2018-12-12T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-12-14T10:57:02.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"name": "106185",
"tags": [
"vdb-entry",
"x_refsource_BID"
],
"url": "http://www.securityfocus.com/bid/106185"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2018-11464",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SINUMERIK 828D V4.7, SINUMERIK 840D sl V4.7, SINUMERIK 840D sl V4.8",
"version": {
"version_data": [
{
"version_value": "SINUMERIK 828D V4.7 : All versions \u003c V4.7 SP6 HF1"
},
{
"version_value": "SINUMERIK 840D sl V4.7 : All versions \u003c V4.7 SP6 HF5"
},
{
"version_value": "SINUMERIK 840D sl V4.8 : All versions \u003c V4.8 SP3"
}
]
}
}
]
},
"vendor_name": "Siemens AG"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SINUMERIK 828D V4.7 (All versions \u003c V4.7 SP6 HF1), SINUMERIK 840D sl V4.7 (All versions \u003c V4.7 SP6 HF5), SINUMERIK 840D sl V4.8 (All versions \u003c V4.8 SP3). The integrated VNC server on port 5900/tcp of the affected products could allow a remote attacker to cause a Denial-of-Service condition of the VNC server. Please note that this vulnerability is only exploitable if port 5900/tcp is manually opened in the firewall configuration of network port X130. The security vulnerability could be exploited by an attacker with network access to the affected devices and port. Successful exploitation requires no privileges and no user interaction. The vulnerability could allow an attacker to compromise availability of the VNC server. At the time of advisory publication no public exploitation of this security vulnerability was known."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "106185",
"refsource": "BID",
"url": "http://www.securityfocus.com/bid/106185"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-170881.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2018-11464",
"datePublished": "2018-12-12T16:00:00.000Z",
"dateReserved": "2018-05-25T00:00:00.000Z",
"dateUpdated": "2024-08-05T08:10:14.565Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2016-10363 (GCVE-0-2016-10363)
Vulnerability from cvelistv5 – Published: 2017-06-16 21:00 – Updated: 2024-08-06 03:21- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| https://www.elastic.co/community/security | x_refsource_CONFIRM |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-06T03:21:51.334Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.elastic.co/community/security"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Logstash",
"vendor": "Elastic",
"versions": [
{
"status": "affected",
"version": "before 2.3.3"
}
]
}
],
"datePublic": "2016-09-22T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Logstash versions prior to 2.3.3, when using the Netflow Codec plugin, a remote attacker crafting malicious Netflow v5, Netflow v9 or IPFIX packets could perform a denial of service attack on the Logstash instance. The errors resulting from these crafted inputs are not handled by the codec and can cause the Logstash process to exit."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248: Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2017-06-16T20:57:02.000Z",
"orgId": "271b6943-45a9-4f3a-ab4e-976f3fa05b5a",
"shortName": "elastic"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.elastic.co/community/security"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security@elastic.co",
"ID": "CVE-2016-10363",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Logstash",
"version": {
"version_data": [
{
"version_value": "before 2.3.3"
}
]
}
}
]
},
"vendor_name": "Elastic"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Logstash versions prior to 2.3.3, when using the Netflow Codec plugin, a remote attacker crafting malicious Netflow v5, Netflow v9 or IPFIX packets could perform a denial of service attack on the Logstash instance. The errors resulting from these crafted inputs are not handled by the codec and can cause the Logstash process to exit."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-248: Uncaught Exception"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.elastic.co/community/security",
"refsource": "CONFIRM",
"url": "https://www.elastic.co/community/security"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "271b6943-45a9-4f3a-ab4e-976f3fa05b5a",
"assignerShortName": "elastic",
"cveId": "CVE-2016-10363",
"datePublished": "2017-06-16T21:00:00.000Z",
"dateReserved": "2017-05-02T00:00:00.000Z",
"dateUpdated": "2024-08-06T03:21:51.334Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2013-10065 (GCVE-0-2013-10065)
Vulnerability from cvelistv5 – Published: 2025-08-05 20:05 – Updated: 2025-11-21 00:20- CWE-248 - Uncaught Exception
| URL | Tags |
|---|---|
| https://www.mattandreko.com/2013/04/08/sysax-mult… | technical-descriptionexploit |
| https://raw.githubusercontent.com/rapid7/metasplo… | exploit |
| https://www.sysax.com/ | product |
| https://www.vulncheck.com/advisories/sysax-multi-… | third-party-advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| Sysax Software | Multi-Server |
Affected:
6.10
cpe:2.3:a:sysax:multi_server:6.10:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2013-10065",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-08-07T15:14:58.420516Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-08-07T15:15:02.627Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://www.mattandreko.com/2013/04/08/sysax-multi-server-6.10-ssh-dos/"
},
{
"tags": [
"exploit"
],
"url": "https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/auxiliary/dos/windows/ssh/sysax_sshd_kexchange.rb"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Multi-Server",
"vendor": "Sysax Software",
"versions": [
{
"status": "affected",
"version": "6.10"
}
]
}
],
"cpeApplicability": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:sysax:multi_server:6.10:*:*:*:*:*:*:*",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "OR"
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Matt \"hostess\" Andreko"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eA denial-of-service vulnerability exists in\u0026nbsp;\u003c/span\u003eSysax Multi-Server version 6.10 via its SSH daemon. A specially crafted SSH key exchange packet can trigger a crash in the service, resulting in loss of availability. The flaw is triggered during the handling of malformed key exchange data, including a non-standard byte (\u003ccode\u003e\\x28\u003c/code\u003e) in place of the expected SSH protocol delimiter.\u003c/p\u003e"
}
],
"value": "A denial-of-service vulnerability exists in\u00a0Sysax Multi-Server version 6.10 via its SSH daemon. A specially crafted SSH key exchange packet can trigger a crash in the service, resulting in loss of availability. The flaw is triggered during the handling of malformed key exchange data, including a non-standard byte (\\x28) in place of the expected SSH protocol delimiter."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-248",
"description": "CWE-248 Uncaught Exception",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-11-21T00:20:54.941Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"technical-description",
"exploit"
],
"url": "https://www.mattandreko.com/2013/04/08/sysax-multi-server-6.10-ssh-dos/"
},
{
"tags": [
"exploit"
],
"url": "https://raw.githubusercontent.com/rapid7/metasploit-framework/master/modules/auxiliary/dos/windows/ssh/sysax_sshd_kexchange.rb"
},
{
"tags": [
"product"
],
"url": "https://www.sysax.com/"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/sysax-multi-server-sshd-key-exchange-dos"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Sysax Multi-Server \u003c= 6.10 SSHD Key Exchange DoS",
"x_generator": {
"engine": "vulncheck"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2013-10065",
"datePublished": "2025-08-05T20:05:06.769Z",
"dateReserved": "2025-08-05T13:37:32.199Z",
"dateUpdated": "2025-11-21T00:20:54.941Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
GHSA-22WV-V5WX-CM9X
Vulnerability from github – Published: 2026-07-18 15:31 – Updated: 2026-07-18 15:31SurrealDB versions before 1.1.1 fail to properly validate invocation of custom parameters and functions at root or namespace levels, causing server panic. Authorized clients can invoke these entities at unsupported levels to crash the SurrealDB server, resulting in denial of service.
{
"affected": [],
"aliases": [
"CVE-2024-58369"
],
"database_specific": {
"cwe_ids": [
"CWE-248"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2026-07-18T14:17:10Z",
"severity": "HIGH"
},
"details": "SurrealDB versions before 1.1.1 fail to properly validate invocation of custom parameters and functions at root or namespace levels, causing server panic. Authorized clients can invoke these entities at unsupported levels to crash the SurrealDB server, resulting in denial of service.",
"id": "GHSA-22wv-v5wx-cm9x",
"modified": "2026-07-18T15:31:49Z",
"published": "2026-07-18T15:31:49Z",
"references": [
{
"type": "WEB",
"url": "https://github.com/surrealdb/surrealdb/security/advisories/GHSA-jm4v-58r5-66hj"
},
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2024-58369"
},
{
"type": "WEB",
"url": "https://www.vulncheck.com/advisories/surrealdb-before-denial-of-service-via-global-parameters"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
},
{
"score": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"type": "CVSS_V4"
}
]
}
GHSA-25R4-295R-FVQM
Vulnerability from github – Published: 2022-05-24 16:56 – Updated: 2026-05-29 15:30A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus.
{
"affected": [],
"aliases": [
"CVE-2019-6829"
],
"database_specific": {
"cwe_ids": [
"CWE-248",
"CWE-755"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-09-17T20:15:00Z",
"severity": "HIGH"
},
"details": "A CWE-248: Uncaught Exception vulnerability exists in Modicon M580 (firmware version prior to V2.90) and Modicon M340 (firmware version prior to V3.10), which could cause a possible denial of service when writing to specific memory addresses in the controller over Modbus.",
"id": "GHSA-25r4-295r-fvqm",
"modified": "2026-05-29T15:30:21Z",
"published": "2022-05-24T16:56:24Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2019-6829"
},
{
"type": "WEB",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
No mitigation information available for this CWE.
No CAPEC attack patterns related to this CWE.