CVE-2025-59109 (GCVE-0-2025-59109)

Vulnerability from cvelistv5 – Published: 2026-01-26 10:06 – Updated: 2026-03-03 18:11
VLAI
Title
UART Leaking Sensitive Data in dormakaba registration unit 9002
Summary
The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi).
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2026-01-26 12:24 UTC
CWE
  • CWE-1295 - Debug Messages Revealing Unnecessary Information
Assigner
SEC-VLab CNA under the mitre root
CNA scorecard B 83/100 over 23 records in the last 180 days details
Impacted products
Vendor Product Version CPE status
dormakaba dormakaba registration unit 9002 Affected: <SW0039
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2026-01-27T06:06:05.350Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "url": "http://seclists.org/fulldisclosure/2026/Jan/24"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-59109",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-26T12:24:28.914159Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-03-03T18:11:39.321Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "dormakaba registration unit 9002",
          "vendor": "dormakaba",
          "versions": [
            {
              "status": "affected",
              "version": "\u003cSW0039"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Clemens Stockenreitner, SEC Consult Vulnerability Lab"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "Werner Schober, SEC Consult Vulnerability Lab"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi).\u003cbr\u003e"
            }
          ],
          "value": "The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi)."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-121",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-121: Exploit Non-Production Interfaces"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "PHYSICAL",
            "baseScore": 5.1,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "ACTIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1295",
              "description": "CWE-1295: Debug Messages Revealing Unnecessary Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-26T10:06:45.739Z",
        "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "shortName": "SEC-VLab"
      },
      "references": [
        {
          "tags": [
            "technical-description"
          ],
          "url": "https://r.sec-consult.com/dormakaba"
        },
        {
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://r.sec-consult.com/dkaccess"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dormakabagroup.com/en/security-advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "If the 9002 is installed in an insecure location, it could be manipulated. Hardware access and special equipment is needed to exploit this vulnerability. Also, the manipulated device would need to be reinstalled. To mitigate this vulnerability for 9002 in insecure locations, a newer version of the 9002 (Serial number starts with: 0700039\u2026) could be installed. Important: The version of the installed 9002 can only be checked on-site.\u003cbr\u003e"
            }
          ],
          "value": "If the 9002 is installed in an insecure location, it could be manipulated. Hardware access and special equipment is needed to exploit this vulnerability. Also, the manipulated device would need to be reinstalled. To mitigate this vulnerability for 9002 in insecure locations, a newer version of the 9002 (Serial number starts with: 0700039\u2026) could be installed. Important: The version of the installed 9002 can only be checked on-site."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "UART Leaking Sensitive Data in dormakaba registration unit 9002",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
    "assignerShortName": "SEC-VLab",
    "cveId": "CVE-2025-59109",
    "datePublished": "2026-01-26T10:06:45.739Z",
    "dateReserved": "2025-09-09T07:53:12.880Z",
    "dateUpdated": "2026-03-03T18:11:39.321Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2025-59109",
      "date": "2026-11-15",
      "epss": "0.00448",
      "percentile": "0.39493"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "dormakaba registration unit 9002",
                "vendor": "dormakaba",
                "versions": [
                  {
                    "status": "affected",
                    "version": "\u003cSW0039"
                  }
                ]
              }
            ],
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi)."
          },
          {
            "lang": "es",
            "value": "Las unidades de registro dormakaba 9002 (Unidades de teclado PIN) tienen un encabezado UART expuesto en la parte trasera. El teclado PIN est\u00e1 enviando cada pulsaci\u00f3n de bot\u00f3n a la interfaz UART. Un atacante puede usar la interfaz para exfiltrar PINs. Dado que los dispositivos est\u00e1n expl\u00edcitamente construidos como Plug-and-Play para ser f\u00e1cilmente reemplazados, un atacante puede f\u00e1cilmente retirar el dispositivo, instalar un implante de hardware que se conecta al UART y exfiltrar los datos expuestos a trav\u00e9s de UART a otro sistema (p. ej., v\u00eda WiFi)."
          }
        ],
        "id": "CVE-2025-59109",
        "lastModified": "2026-06-17T09:45:34.140",
        "metrics": {
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2025-59109",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-26T12:24:28.914159Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2026-01-26T10:16:08.890",
        "references": [
          {
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "url": "https://r.sec-consult.com/dkaccess"
          },
          {
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "url": "https://r.sec-consult.com/dormakaba"
          },
          {
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "url": "https://www.dormakabagroup.com/en/security-advisories"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://seclists.org/fulldisclosure/2026/Jan/24"
          }
        ],
        "sourceIdentifier": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-1295"
              }
            ],
            "source": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T08:29:00+00:00",
      "cve": "CVE-2025-59109",
      "id": "CVE-2025-59109",
      "initial_release_date": "2025-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "UART Leaking Sensitive Data in dormakaba registration unit 9002",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2025/cve-2025-59109.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2026-01-27T06:06:05.350Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "url": "http://seclists.org/fulldisclosure/2026/Jan/24"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2025-59109",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2026-01-26T12:24:28.914159Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2026-03-03T18:11:36.292Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "dormakaba registration unit 9002",
              "vendor": "dormakaba",
              "versions": [
                {
                  "status": "affected",
                  "version": "\u003cSW0039"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "value": "Clemens Stockenreitner, SEC Consult Vulnerability Lab"
            },
            {
              "lang": "en",
              "type": "finder",
              "value": "Werner Schober, SEC Consult Vulnerability Lab"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi).\u003cbr\u003e"
                }
              ],
              "value": "The dormakaba registration units 9002 (PIN Pad Units) have an exposed UART header on the backside. The PIN pad is sending every button press to the UART interface. An attacker can use the interface to exfiltrate PINs. As the devices are explicitly built as Plug-and-Play to be easily replaced, an attacker is easily able to remove the device, install a hardware implant which connects to the UART and exfiltrates the data exposed via UART to another system (e.g. via WiFi)."
            }
          ],
          "impacts": [
            {
              "capecId": "CAPEC-121",
              "descriptions": [
                {
                  "lang": "en",
                  "value": "CAPEC-121: Exploit Non-Production Interfaces"
                }
              ]
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "PHYSICAL",
                "baseScore": 5.1,
                "baseSeverity": "MEDIUM",
                "exploitMaturity": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "ACTIVE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:P/AC:L/AT:N/PR:N/UI:A/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "HIGH",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-1295",
                  "description": "CWE-1295: Debug Messages Revealing Unnecessary Information",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2026-01-26T10:06:45.739Z",
            "orgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
            "shortName": "SEC-VLab"
          },
          "references": [
            {
              "tags": [
                "technical-description"
              ],
              "url": "https://r.sec-consult.com/dormakaba"
            },
            {
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://r.sec-consult.com/dkaccess"
            },
            {
              "tags": [
                "vendor-advisory"
              ],
              "url": "https://www.dormakabagroup.com/en/security-advisories"
            }
          ],
          "solutions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "If the 9002 is installed in an insecure location, it could be manipulated. Hardware access and special equipment is needed to exploit this vulnerability. Also, the manipulated device would need to be reinstalled. To mitigate this vulnerability for 9002 in insecure locations, a newer version of the 9002 (Serial number starts with: 0700039\u2026) could be installed. Important: The version of the installed 9002 can only be checked on-site.\u003cbr\u003e"
                }
              ],
              "value": "If the 9002 is installed in an insecure location, it could be manipulated. Hardware access and special equipment is needed to exploit this vulnerability. Also, the manipulated device would need to be reinstalled. To mitigate this vulnerability for 9002 in insecure locations, a newer version of the 9002 (Serial number starts with: 0700039\u2026) could be installed. Important: The version of the installed 9002 can only be checked on-site."
            }
          ],
          "source": {
            "discovery": "EXTERNAL"
          },
          "title": "UART Leaking Sensitive Data in dormakaba registration unit 9002",
          "x_generator": {
            "engine": "Vulnogram 0.5.0"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "551230f0-3615-47bd-b7cc-93e92e730bbf",
        "assignerShortName": "SEC-VLab",
        "cveId": "CVE-2025-59109",
        "datePublished": "2026-01-26T10:06:45.739Z",
        "dateReserved": "2025-09-09T07:53:12.880Z",
        "dateUpdated": "2026-03-03T18:11:39.321Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.