GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2024-41968 (GCVE-0-2024-41968)

Vulnerability from cvelistv5 – Published: 2024-11-18 09:03 – Updated: 2025-08-27 21:33
VLAI
Title
WAGO: Docker Settings Manipulation in Multiple Devices
Summary
A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-19 14:56 UTC
CWE
  • CWE-306 - Missing Authentication for Critical Function
References
Impacted products
Vendor Product Version CPE status
WAGO CC100 0751-9x01 Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO PFC100 G2 0750-811x-xxxx-xxxx Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO PFC200 G2 750-821x-xxx-xxx Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO TP600 0762-420x/8000-000x Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO TP600 0762-430x/8000-000x Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO TP600 0762-520x/8000-000x Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO TP600 0762-530x/8000-000x Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO TP600 0762-620x/8000-000x Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO TP600 0762-630x/8000-000x Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO Edge Controller 0752-8303/8000-0002 Affected: 0.0.0 , ≤ 4.5.10 (FW27) (semver)
guessed Create a notification for this product.
WAGO PFC100 G1 0750-810x/xxxx-xxxx Affected: 0.0.0 , ≤ 3.10.10 (FW22 Patch 1) (semver)
guessed Create a notification for this product.
WAGO PFC200 G1 750-820x-xxx-xxx Affected: 0.0.0 , ≤ 3.10.10 (FW22 Patch 1) (semver)
guessed Create a notification for this product.
WAGO PFC200 G1 0750-820x/xxx-xxx Affected: 0.0.0 , ≤ 03.03.08 (80) (semver)
guessed Create a notification for this product.
WAGO PFC200 G2 0750-821x/xxx-xxx Affected: 0.0.0 , ≤ 04.04.03 (70) (semver)
guessed Create a notification for this product.
WAGO CC100 0751/9x01 Affected: 0.0.0 , ≤ 04.03.03 (72) (semver)
guessed Create a notification for this product.
WAGO CC100 0751/9x01 Affected: 0.0.0 , ≤ 04.04.03 (70) (semver)
guessed Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "LOW",
              "baseScore": 6.5,
              "baseSeverity": "MEDIUM",
              "confidentialityImpact": "NONE",
              "integrityImpact": "LOW",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2024-41968",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-19T14:56:16.336634Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-27T21:33:03.869Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CC100 0751-9x01",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PFC100 G2 0750-811x-xxxx-xxxx",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PFC200 G2 750-821x-xxx-xxx",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TP600 0762-420x/8000-000x",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TP600 0762-430x/8000-000x",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TP600 0762-520x/8000-000x",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TP600 0762-530x/8000-000x",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TP600 0762-620x/8000-000x",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TP600 0762-630x/8000-000x",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Edge Controller 0752-8303/8000-0002",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "4.5.10 (FW27)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PFC100 G1 0750-810x/xxxx-xxxx",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "3.10.10 (FW22 Patch 1)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PFC200 G1 750-820x-xxx-xxx",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "3.10.10 (FW22 Patch 1)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PFC200 G1 0750-820x/xxx-xxx",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "03.03.08 (80)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PFC200 G2 0750-821x/xxx-xxx",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "04.04.03 (70)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CC100 0751/9x01",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "04.03.03 (72)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CC100 0751/9x01",
          "vendor": "WAGO",
          "versions": [
            {
              "lessThanOrEqual": "04.04.03 (70)",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Diego Giubertoni"
        },
        {
          "lang": "en",
          "type": "reporter",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Nozomi Networks"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS.\u0026nbsp;\u003cbr\u003e"
            }
          ],
          "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.4,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-306",
              "description": "CWE-306 Missing Authentication for Critical Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-01-30T09:20:17.138Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://cert.vde.com/en/advisories/VDE-2024-047"
        }
      ],
      "source": {
        "advisory": "VDE-2024-047",
        "defect": [
          "CERT@VDE#641658"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "WAGO: Docker Settings Manipulation in Multiple Devices",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2024-41968",
    "datePublished": "2024-11-18T09:03:20.948Z",
    "dateReserved": "2024-07-25T09:07:31.463Z",
    "dateUpdated": "2025-08-27T21:33:03.869Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-41968",
      "date": "2026-09-20",
      "epss": "0.00339",
      "percentile": "0.27467"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "defaultStatus": "unaffected",
                "product": "CC100 0751-9x01",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "PFC100 G2 0750-811x-xxxx-xxxx",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "PFC200 G2 750-821x-xxx-xxx",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "TP600 0762-420x/8000-000x",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "TP600 0762-430x/8000-000x",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "TP600 0762-520x/8000-000x",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "TP600 0762-530x/8000-000x",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "TP600 0762-620x/8000-000x",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "TP600 0762-630x/8000-000x",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "Edge Controller 0752-8303/8000-0002",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "4.5.10 (FW27)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "PFC100 G1 0750-810x/xxxx-xxxx",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "3.10.10 (FW22 Patch 1)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "PFC200 G1 750-820x-xxx-xxx",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "3.10.10 (FW22 Patch 1)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "PFC200 G1 0750-820x/xxx-xxx",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "03.03.08 (80)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "PFC200 G2 0750-821x/xxx-xxx",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "04.04.03 (70)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "CC100 0751/9x01",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "04.03.03 (72)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              },
              {
                "defaultStatus": "unaffected",
                "product": "CC100 0751/9x01",
                "vendor": "WAGO",
                "versions": [
                  {
                    "lessThanOrEqual": "04.04.03 (70)",
                    "status": "affected",
                    "version": "0.0.0",
                    "versionType": "semver"
                  }
                ]
              }
            ],
            "source": "info@cert.vde.com"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS."
          },
          {
            "lang": "es",
            "value": "Un atacante remoto con pocos privilegios puede modificar la configuraci\u00f3n de Docker del dispositivo, lo que genera un DoS limitado."
          }
        ],
        "id": "CVE-2024-41968",
        "lastModified": "2026-06-17T07:48:32.640",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 2.5,
              "source": "info@cert.vde.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 6.5,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 2.5,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-41968",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-19T14:56:16.336634Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-11-18T09:15:05.410",
        "references": [
          {
            "source": "info@cert.vde.com",
            "url": "https://cert.vde.com/en/advisories/VDE-2024-047"
          }
        ],
        "sourceIdentifier": "info@cert.vde.com",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-306"
              }
            ],
            "source": "info@cert.vde.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T18:37:06+00:00",
      "cve": "CVE-2024-41968",
      "id": "CVE-2024-41968",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "WAGO: Docker Settings Manipulation in Multiple Devices",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-41968.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "LOW",
                  "baseScore": 6.5,
                  "baseSeverity": "MEDIUM",
                  "confidentialityImpact": "NONE",
                  "integrityImpact": "LOW",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:L",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-41968",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-19T14:56:16.336634Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-19T14:56:46.841Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "defaultStatus": "unaffected",
              "product": "CC100 0751-9x01",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 G2 0750-811x-xxxx-xxxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 G2 750-821x-xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TP600 0762-420x/8000-000x",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TP600 0762-430x/8000-000x",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TP600 0762-520x/8000-000x",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TP600 0762-530x/8000-000x",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TP600 0762-620x/8000-000x",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "TP600 0762-630x/8000-000x",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "Edge Controller 0752-8303/8000-0002",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "4.5.10 (FW27)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC100 G1 0750-810x/xxxx-xxxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "3.10.10 (FW22 Patch 1)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 G1 750-820x-xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "3.10.10 (FW22 Patch 1)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 G1 0750-820x/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "03.03.08 (80)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "PFC200 G2 0750-821x/xxx-xxx",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "04.04.03 (70)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CC100 0751/9x01",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "04.03.03 (72)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            },
            {
              "defaultStatus": "unaffected",
              "product": "CC100 0751/9x01",
              "vendor": "WAGO",
              "versions": [
                {
                  "lessThanOrEqual": "04.04.03 (70)",
                  "status": "affected",
                  "version": "0.0.0",
                  "versionType": "semver"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "finder",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Diego Giubertoni"
            },
            {
              "lang": "en",
              "type": "reporter",
              "user": "00000000-0000-4000-9000-000000000000",
              "value": "Nozomi Networks"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "supportingMedia": [
                {
                  "base64": false,
                  "type": "text/html",
                  "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS.\u0026nbsp;\u003cbr\u003e"
                }
              ],
              "value": "A low privileged remote attacker may modify the docker settings setup of the device, leading to a limited DoS."
            }
          ],
          "metrics": [
            {
              "cvssV3_1": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "LOW",
                "baseScore": 5.4,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "NONE",
                "integrityImpact": "LOW",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:L",
                "version": "3.1"
              },
              "format": "CVSS",
              "scenarios": [
                {
                  "lang": "en",
                  "value": "GENERAL"
                }
              ]
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-306",
                  "description": "CWE-306 Missing Authentication for Critical Function",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2025-01-30T09:20:17.138Z",
            "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
            "shortName": "CERTVDE"
          },
          "references": [
            {
              "url": "https://cert.vde.com/en/advisories/VDE-2024-047"
            }
          ],
          "source": {
            "advisory": "VDE-2024-047",
            "defect": [
              "CERT@VDE#641658"
            ],
            "discovery": "UNKNOWN"
          },
          "title": "WAGO: Docker Settings Manipulation in Multiple Devices",
          "x_generator": {
            "engine": "Vulnogram 0.1.0-dev"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "assignerShortName": "CERTVDE",
        "cveId": "CVE-2024-41968",
        "datePublished": "2024-11-18T09:03:20.948Z",
        "dateReserved": "2024-07-25T09:07:31.463Z",
        "dateUpdated": "2025-08-27T21:33:03.869Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…