CVE-2024-11306 (GCVE-0-2024-11306)

Vulnerability from cvelistv5 – Published: 2024-11-18 01:31 – Updated: 2024-11-19 16:28
VLAI
Title
Altenergy Power Control Software database improper authorization
Summary
A vulnerability, which was classified as critical, has been found in Altenergy Power Control Software up to 20241108. This issue affects some unknown processing of the file /index.php/display/database/. The manipulation leads to improper authorization. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Other endpoints might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way.
SSVC
Exploitation: poc Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-11-19 16:27 UTC
CWE
  • CWE-285 - Improper Authorization
  • CWE-266 - Incorrect Privilege Assignment
Assigner
VulDB CNA under the mitre root
CNA scorecard B 83/100 over 3779 records in the last 180 days details
References
Impacted products
Vendor Product Version CPE status
Altenergy Power Control Software Affected: 20241108
guessed Create a notification for this product.
altenergy power_control_software Affected: 0 , ≤ 20241108 (custom)
    cpe:2.3:a:altenergy:power_control_software:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:altenergy:power_control_software:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "power_control_software",
            "vendor": "altenergy",
            "versions": [
              {
                "lessThanOrEqual": "20241108",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-11306",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-19T16:27:50.799495Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-11-19T16:28:22.622Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Power Control Software",
          "vendor": "Altenergy",
          "versions": [
            {
              "status": "affected",
              "version": "20241108"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "reporter",
          "value": "H0e4a0r1t_-_- (VulDB User)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability, which was classified as critical, has been found in Altenergy Power Control Software up to 20241108. This issue affects some unknown processing of the file /index.php/display/database/. The manipulation leads to improper authorization. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Other endpoints might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way."
        },
        {
          "lang": "de",
          "value": "Eine Schwachstelle wurde in Altenergy Power Control Software bis 20241108 entdeckt. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /index.php/display/database/. Durch Manipulation mit unbekannten Daten kann eine improper authorization-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0"
          }
        },
        {
          "cvssV3_1": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        {
          "cvssV3_0": {
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.0"
          }
        },
        {
          "cvssV2_0": {
            "baseScore": 5,
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
            "version": "2.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-285",
              "description": "Improper Authorization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        },
        {
          "descriptions": [
            {
              "cweId": "CWE-266",
              "description": "Incorrect Privilege Assignment",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-11-18T01:31:03.950Z",
        "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "shortName": "VulDB"
      },
      "references": [
        {
          "name": "VDB-284915 | Altenergy Power Control Software database improper authorization",
          "tags": [
            "vdb-entry"
          ],
          "url": "https://vuldb.com/?id.284915"
        },
        {
          "name": "VDB-284915 | CTI Indicators (IOB, IOC, TTP, IOA)",
          "tags": [
            "signature",
            "permissions-required"
          ],
          "url": "https://vuldb.com/?ctiid.284915"
        },
        {
          "name": "Submit #439804 | Altenergy Altenergy Power Control Software Altenergy Power Control Software Improper Authorization of Index Containing Sensitive Information",
          "tags": [
            "third-party-advisory"
          ],
          "url": "https://vuldb.com/?submit.439804"
        },
        {
          "tags": [
            "exploit"
          ],
          "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/HYO%3BY)v%3B4%5C)jLCjp/Altenergy%20Power%20Control%20Software%20Information%20Disclosure%20Vulnerability_database.pdf"
        }
      ],
      "timeline": [
        {
          "lang": "en",
          "time": "2024-11-17T00:00:00.000Z",
          "value": "Advisory disclosed"
        },
        {
          "lang": "en",
          "time": "2024-11-17T01:00:00.000Z",
          "value": "VulDB entry created"
        },
        {
          "lang": "en",
          "time": "2024-11-17T20:45:32.000Z",
          "value": "VulDB entry last update"
        }
      ],
      "title": "Altenergy Power Control Software database improper authorization"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
    "assignerShortName": "VulDB",
    "cveId": "CVE-2024-11306",
    "datePublished": "2024-11-18T01:31:03.950Z",
    "dateReserved": "2024-11-17T19:40:25.024Z",
    "dateUpdated": "2024-11-19T16:28:22.622Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2024-11306",
      "date": "2026-11-07",
      "epss": "0.00548",
      "percentile": "0.46128"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "Power Control Software",
                "vendor": "Altenergy",
                "versions": [
                  {
                    "status": "affected",
                    "version": "20241108"
                  }
                ]
              }
            ],
            "source": "cna@vuldb.com"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:a:altenergy:power_control_software:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "power_control_software",
                "vendor": "altenergy",
                "versions": [
                  {
                    "lessThanOrEqual": "20241108",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "A vulnerability, which was classified as critical, has been found in Altenergy Power Control Software up to 20241108. This issue affects some unknown processing of the file /index.php/display/database/. The manipulation leads to improper authorization. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Other endpoints might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way."
          },
          {
            "lang": "es",
            "value": "Se ha encontrado una vulnerabilidad, que se ha clasificado como cr\u00edtica, en Altenergy Power Control Software hasta 20241108. Este problema afecta a algunos procesos desconocidos del archivo /index.php/display/database/. La manipulaci\u00f3n conduce a una autorizaci\u00f3n incorrecta. El ataque puede iniciarse de forma remota. El exploit se ha divulgado al p\u00fablico y puede utilizarse. Tambi\u00e9n podr\u00edan verse afectados otros endpoints. Se contact\u00f3 al proveedor con anticipaci\u00f3n sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
          }
        ],
        "id": "CVE-2024-11306",
        "lastModified": "2026-06-17T06:57:30.237",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "cna@vuldb.com",
              "type": "Secondary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 1.4,
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "cvssMetricV40": [
            {
              "cvssData": {
                "Automatable": "NOT_DEFINED",
                "Recovery": "NOT_DEFINED",
                "Safety": "NOT_DEFINED",
                "attackComplexity": "LOW",
                "attackRequirements": "NONE",
                "attackVector": "NETWORK",
                "availabilityRequirement": "NOT_DEFINED",
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "confidentialityRequirement": "NOT_DEFINED",
                "exploitMaturity": "NOT_DEFINED",
                "integrityRequirement": "NOT_DEFINED",
                "modifiedAttackComplexity": "NOT_DEFINED",
                "modifiedAttackRequirements": "NOT_DEFINED",
                "modifiedAttackVector": "NOT_DEFINED",
                "modifiedPrivilegesRequired": "NOT_DEFINED",
                "modifiedSubAvailabilityImpact": "NOT_DEFINED",
                "modifiedSubConfidentialityImpact": "NOT_DEFINED",
                "modifiedSubIntegrityImpact": "NOT_DEFINED",
                "modifiedUserInteraction": "NOT_DEFINED",
                "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
                "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
                "modifiedVulnIntegrityImpact": "NOT_DEFINED",
                "privilegesRequired": "NONE",
                "providerUrgency": "NOT_DEFINED",
                "subAvailabilityImpact": "NONE",
                "subConfidentialityImpact": "NONE",
                "subIntegrityImpact": "NONE",
                "userInteraction": "NONE",
                "valueDensity": "NOT_DEFINED",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
                "version": "4.0",
                "vulnAvailabilityImpact": "NONE",
                "vulnConfidentialityImpact": "LOW",
                "vulnIntegrityImpact": "NONE",
                "vulnerabilityResponseEffort": "NOT_DEFINED"
              },
              "source": "cna@vuldb.com",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2024-11306",
                "options": [
                  {
                    "exploitation": "poc"
                  },
                  {
                    "automatable": "yes"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-11-19T16:27:50.799495Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-11-18T02:15:15.577",
        "references": [
          {
            "source": "cna@vuldb.com",
            "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/HYO%3BY)v%3B4%5C)jLCjp/Altenergy%20Power%20Control%20Software%20Information%20Disclosure%20Vulnerability_database.pdf"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?ctiid.284915"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?id.284915"
          },
          {
            "source": "cna@vuldb.com",
            "url": "https://vuldb.com/?submit.439804"
          }
        ],
        "sourceIdentifier": "cna@vuldb.com",
        "vulnStatus": "Deferred",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-266"
              },
              {
                "lang": "en",
                "value": "CWE-285"
              }
            ],
            "source": "cna@vuldb.com",
            "type": "Secondary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T19:39:40+00:00",
      "cve": "CVE-2024-11306",
      "id": "CVE-2024-11306",
      "initial_release_date": "2024-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "Altenergy Power Control Software database improper authorization",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2024/cve-2024-11306.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:a:altenergy:power_control_software:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "power_control_software",
                "vendor": "altenergy",
                "versions": [
                  {
                    "lessThanOrEqual": "20241108",
                    "status": "affected",
                    "version": "0",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2024-11306",
                    "options": [
                      {
                        "Exploitation": "poc"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-11-19T16:27:50.799495Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-11-19T16:28:17.233Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Power Control Software",
              "vendor": "Altenergy",
              "versions": [
                {
                  "status": "affected",
                  "version": "20241108"
                }
              ]
            }
          ],
          "credits": [
            {
              "lang": "en",
              "type": "reporter",
              "value": "H0e4a0r1t_-_- (VulDB User)"
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "A vulnerability, which was classified as critical, has been found in Altenergy Power Control Software up to 20241108. This issue affects some unknown processing of the file /index.php/display/database/. The manipulation leads to improper authorization. The attack may be initiated remotely. The exploit has been disclosed to the public and may be used. Other endpoints might be affected as well. The vendor was contacted early about this disclosure but did not respond in any way."
            },
            {
              "lang": "de",
              "value": "Eine Schwachstelle wurde in Altenergy Power Control Software bis 20241108 entdeckt. Sie wurde als kritisch eingestuft. Davon betroffen ist unbekannter Code der Datei /index.php/display/database/. Durch Manipulation mit unbekannten Daten kann eine improper authorization-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk erfolgen. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
            }
          ],
          "metrics": [
            {
              "cvssV4_0": {
                "baseScore": 6.9,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
                "version": "4.0"
              }
            },
            {
              "cvssV3_1": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.1"
              }
            },
            {
              "cvssV3_0": {
                "baseScore": 5.3,
                "baseSeverity": "MEDIUM",
                "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
                "version": "3.0"
              }
            },
            {
              "cvssV2_0": {
                "baseScore": 5,
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              }
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "cweId": "CWE-285",
                  "description": "Improper Authorization",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            },
            {
              "descriptions": [
                {
                  "cweId": "CWE-266",
                  "description": "Incorrect Privilege Assignment",
                  "lang": "en",
                  "type": "CWE"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-11-18T01:31:03.950Z",
            "orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
            "shortName": "VulDB"
          },
          "references": [
            {
              "name": "VDB-284915 | Altenergy Power Control Software database improper authorization",
              "tags": [
                "vdb-entry"
              ],
              "url": "https://vuldb.com/?id.284915"
            },
            {
              "name": "VDB-284915 | CTI Indicators (IOB, IOC, TTP, IOA)",
              "tags": [
                "signature",
                "permissions-required"
              ],
              "url": "https://vuldb.com/?ctiid.284915"
            },
            {
              "name": "Submit #439804 | Altenergy Altenergy Power Control Software Altenergy Power Control Software Improper Authorization of Index Containing Sensitive Information",
              "tags": [
                "third-party-advisory"
              ],
              "url": "https://vuldb.com/?submit.439804"
            },
            {
              "tags": [
                "exploit"
              ],
              "url": "https://github.com/h0e4a0r1t/h0e4a0r1t.github.io/blob/master/2024/HYO%3BY)v%3B4%5C)jLCjp/Altenergy%20Power%20Control%20Software%20Information%20Disclosure%20Vulnerability_database.pdf"
            }
          ],
          "timeline": [
            {
              "lang": "en",
              "time": "2024-11-17T00:00:00.000Z",
              "value": "Advisory disclosed"
            },
            {
              "lang": "en",
              "time": "2024-11-17T01:00:00.000Z",
              "value": "VulDB entry created"
            },
            {
              "lang": "en",
              "time": "2024-11-17T20:45:32.000Z",
              "value": "VulDB entry last update"
            }
          ],
          "title": "Altenergy Power Control Software database improper authorization"
        }
      },
      "cveMetadata": {
        "assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
        "assignerShortName": "VulDB",
        "cveId": "CVE-2024-11306",
        "datePublished": "2024-11-18T01:31:03.950Z",
        "dateReserved": "2024-11-17T19:40:25.024Z",
        "dateUpdated": "2024-11-18T01:31:03.950Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.