GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2023-7017 (GCVE-0-2023-7017)

Vulnerability from cvelistv5 – Published: 2024-03-15 17:07 – Updated: 2025-11-04 18:22
VLAI
Title
CVE-2023-7017
Summary
Sciener locks' firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device.
SSVC
Exploitation: none Automatable: no Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-03-15 19:25 UTC
Impacted products
Vendor Product Version CPE status
Sciener Kontrol Lux Affected: 6.5.x , ≤ 6.5.07 (custom)
guessed Create a notification for this product.
sciener kontrol_lux_firmware Affected: 6.5.x , ≤ 6.5.07 (custom)
    cpe:2.3:o:sciener:kontrol_lux_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2025-11-04T18:22:12.788Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
          },
          {
            "url": "https://www.kb.cert.org/vuls/id/949046"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:sciener:kontrol_lux_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "kontrol_lux_firmware",
            "vendor": "sciener",
            "versions": [
              {
                "lessThanOrEqual": "6.5.07",
                "status": "affected",
                "version": "6.5.x",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2023-7017",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-15T19:25:24.356996Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-28T16:26:36.957Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Kontrol Lux",
          "vendor": "Sciener",
          "versions": [
            {
              "lessThanOrEqual": "6.5.07",
              "status": "affected",
              "version": "6.5.x",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Sciener locks\u0027 firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "CWE-494 Download of Code Without Integrity Check",
              "lang": "en"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-15T17:07:28.081Z",
        "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "shortName": "certcc"
      },
      "references": [
        {
          "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "CVE-2023-7017",
      "x_generator": {
        "engine": "VINCE 2.1.11",
        "env": "prod",
        "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-7017"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
    "assignerShortName": "certcc",
    "cveId": "CVE-2023-7017",
    "datePublished": "2024-03-15T17:07:28.081Z",
    "dateReserved": "2023-12-20T15:50:30.248Z",
    "dateUpdated": "2025-11-04T18:22:12.788Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-7017",
      "date": "2026-09-20",
      "epss": "0.00292",
      "percentile": "0.22058"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "Kontrol Lux",
                "vendor": "Sciener",
                "versions": [
                  {
                    "lessThanOrEqual": "6.5.07",
                    "status": "affected",
                    "version": "6.5.x",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "cret@cert.org"
          },
          {
            "affectedData": [
              {
                "cpes": [
                  "cpe:2.3:o:sciener:kontrol_lux_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "kontrol_lux_firmware",
                "vendor": "sciener",
                "versions": [
                  {
                    "lessThanOrEqual": "6.5.07",
                    "status": "affected",
                    "version": "6.5.x",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Sciener locks\u0027 firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device."
          },
          {
            "lang": "es",
            "value": "El mecanismo de actualizaci\u00f3n de firmware de las cerraduras Sciener no autentica ni valida las actualizaciones de firmware si se pasan a la cerradura a trav\u00e9s del servicio Bluetooth Low Energy. Se puede enviar una solicitud de desaf\u00edo a la cerradura con un comando para prepararse para una actualizaci\u00f3n, en lugar de una solicitud de desbloqueo, lo que permite a un atacante comprometer el dispositivo."
          }
        ],
        "id": "CVE-2023-7017",
        "lastModified": "2026-06-17T06:51:52.813",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-7017",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-15T19:25:24.356996Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2024-03-15T17:15:07.857",
        "references": [
          {
            "source": "cret@cert.org",
            "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "https://www.kb.cert.org/vuls/id/949046"
          }
        ],
        "sourceIdentifier": "cret@cert.org",
        "vulnStatus": "Deferred"
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-28T23:17:30+00:00",
      "cve": "CVE-2023-7017",
      "id": "CVE-2023-7017",
      "initial_release_date": "2023-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2023-7017",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-7017.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2025-11-04T18:22:12.788Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
              },
              {
                "url": "https://www.kb.cert.org/vuls/id/949046"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:sciener:kontrol_lux_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "kontrol_lux_firmware",
                "vendor": "sciener",
                "versions": [
                  {
                    "lessThanOrEqual": "6.5.07",
                    "status": "affected",
                    "version": "6.5.x",
                    "versionType": "custom"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-7017",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-03-15T19:25:24.356996Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-08-28T16:26:31.794Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "Kontrol Lux",
              "vendor": "Sciener",
              "versions": [
                {
                  "lessThanOrEqual": "6.5.07",
                  "status": "affected",
                  "version": "6.5.x",
                  "versionType": "custom"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "Sciener locks\u0027 firmware update mechanism do not authenticate or validate firmware updates if passed to the lock through the Bluetooth Low Energy service. A challenge request can be sent to the lock with a command to prepare for an update, rather than an unlock request, allowing an attacker to compromise the device."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "CWE-494 Download of Code Without Integrity Check",
                  "lang": "en"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-03-15T17:07:28.081Z",
            "orgId": "37e5125f-f79b-445b-8fad-9564f167944b",
            "shortName": "certcc"
          },
          "references": [
            {
              "url": "https://alephsecurity.com/2024/03/07/kontrol-lux-lock-2/"
            }
          ],
          "source": {
            "discovery": "UNKNOWN"
          },
          "title": "CVE-2023-7017",
          "x_generator": {
            "engine": "VINCE 2.1.11",
            "env": "prod",
            "origin": "https://cveawg.mitre.org/api/cve/CVE-2023-7017"
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "37e5125f-f79b-445b-8fad-9564f167944b",
        "assignerShortName": "certcc",
        "cveId": "CVE-2023-7017",
        "datePublished": "2024-03-15T17:07:28.081Z",
        "dateReserved": "2023-12-20T15:50:30.248Z",
        "dateUpdated": "2025-11-04T18:22:12.788Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…