CVE-2023-28343 (GCVE-0-2023-28343)

Vulnerability from cvelistv5 – Published: 2023-03-14 00:00 – Updated: 2025-02-27 15:13
VLAI Shadowserver Previdian
Summary
OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone parameter, because of set_timezone in models/management_model.php.
Severity
No CVSS data available.
SSVC
Exploitation: none Automatable: no Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-27 15:12 UTC
CWE
  • n/a
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2023-28343

Status: Confirmed

Status Updated: 2026-09-06 00:00 UTC

Exploited: Yes


Characteristics
Severity: 98.0

Timestamps
First Seen: 2023-10-14
Asserted: 2023-10-14
Last Seen: 2026-09-06

Scope
Asset Exposure: ['internet-facing']
Notes: Affected: APsystems / Altenergy Power Control Software | Class: other-software | Severity: Critical (CVSS 9.8) | IoT: yes | In CISA KEV: no | Honeypot connections on 2026-09-06: 40

Evidence

Type: Honeypot

Signal: In The Wild Attempts

Confidence: 70%

Source: shadowserver


Details
1D 2
Iot yes
Feed Shadowserver Foundation honeypot/exploited-vulnerabilities
Type http-scan
Class other-software
7D Avg 1
Vendor APsystems
30D Avg 0
90D Avg 1
Product Altenergy Power Control Software
Cisa Kev no
Connections 40
Observation Date 2026-09-06
Vulnerability Class CVSS
Vulnerability Score 9.8
Vulnerability Severity Critical

References

Created: 2026-07-01 07:17 UTC | Updated: 2026-09-08 01:01 UTC
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2023-28343

Status: Confirmed

Status Updated: 2025-07-07 00:00 UTC

Exploited: Yes


Timestamps
First Seen: 2025-07-07
Asserted: 2025-07-07

Scope
Notes: KEVIntel entry: OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone... | Affected: Altenergy / Power Control Software | CVSS: 9.8 (CRITICAL) | Used in malware: unknown | Not yet in CISA KEV: True

Evidence

Type: Public Report

Signal: Successful Exploitation

Confidence: 70%

Source: kevintel


Details
Feed KEVIntel (kevintel.com)
Title OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone...
Vendor Altenergy
Product Power Control Software
Added Date 2025-07-07T00:00:00.000Z
Cvss Score 9.8
Epss Score None
Cvss Severity CRITICAL
Epss Percentile None
Used In Malware unknown
Ahead Of Cisa Kev None
Not Yet In Cisa Kev True

References

Created: 2026-06-23 11:12 UTC | Updated: 2026-06-23 11:12 UTC
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T12:38:25.006Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://github.com/ahmedalroky/Disclosures/blob/main/apesystems/os_command_injection.md"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://apsystems.com"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "http://packetstormsecurity.com/files/171775/Altenergy-Power-Control-Software-C1.2.5-Command-Injection.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-28343",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T15:12:59.380835Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-02-27T15:13:32.712Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone parameter, because of set_timezone in models/management_model.php."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-04-10T00:00:00.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://github.com/ahmedalroky/Disclosures/blob/main/apesystems/os_command_injection.md"
        },
        {
          "url": "https://apsystems.com"
        },
        {
          "url": "http://packetstormsecurity.com/files/171775/Altenergy-Power-Control-Software-C1.2.5-Command-Injection.html"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2023-28343",
    "datePublished": "2023-03-14T00:00:00.000Z",
    "dateReserved": "2023-03-14T00:00:00.000Z",
    "dateUpdated": "2025-02-27T15:13:32.712Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2023-28343",
      "date": "2026-09-21",
      "epss": "0.84752",
      "percentile": "0.99703"
    },
    "nvd": {
      "cve": {
        "affected": [
          {
            "affectedData": [
              {
                "product": "n/a",
                "vendor": "n/a",
                "versions": [
                  {
                    "status": "affected",
                    "version": "n/a"
                  }
                ]
              }
            ],
            "source": "cve@mitre.org"
          }
        ],
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:apsystems:energy_communication_unit_firmware:c1.2.5:*:*:*:*:*:*:*",
                    "matchCriteriaId": "2D6A58A9-7602-43D7-B062-AEBED61CF0F3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:apsystems:energy_communication_unit:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "0FFFF6EC-8894-4437-BEBC-7D02516F8EB8",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone parameter, because of set_timezone in models/management_model.php."
          }
        ],
        "id": "CVE-2023-28343",
        "lastModified": "2026-06-17T05:47:29.573",
        "metrics": {
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ],
          "ssvcV203": [
            {
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "ssvcData": {
                "id": "CVE-2023-28343",
                "options": [
                  {
                    "exploitation": "none"
                  },
                  {
                    "automatable": "no"
                  },
                  {
                    "technicalImpact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-27T15:12:59.380835Z",
                "version": "2.0.3"
              }
            }
          ]
        },
        "published": "2023-03-14T20:15:10.123",
        "references": [
          {
            "source": "cve@mitre.org",
            "url": "http://packetstormsecurity.com/files/171775/Altenergy-Power-Control-Software-C1.2.5-Command-Injection.html"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Product"
            ],
            "url": "https://apsystems.com"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/ahmedalroky/Disclosures/blob/main/apesystems/os_command_injection.md"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://packetstormsecurity.com/files/171775/Altenergy-Power-Control-Software-C1.2.5-Command-Injection.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Product"
            ],
            "url": "https://apsystems.com"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://github.com/ahmedalroky/Disclosures/blob/main/apesystems/os_command_injection.md"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2025-05-29T01:01:54+00:00",
      "cve": "CVE-2023-28343",
      "id": "CVE-2023-28343",
      "initial_release_date": "2023-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2023-28343",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2023/cve-2023-28343.json",
      "version": "3"
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-02T12:38:25.006Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://github.com/ahmedalroky/Disclosures/blob/main/apesystems/os_command_injection.md"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://apsystems.com"
              },
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "http://packetstormsecurity.com/files/171775/Altenergy-Power-Control-Software-C1.2.5-Command-Injection.html"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "other": {
                  "content": {
                    "id": "CVE-2023-28343",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "no"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-27T15:12:59.380835Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-27T15:13:06.147Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "OS command injection affects Altenergy Power Control Software C1.2.5 via shell metacharacters in the index.php/management/set_timezone timezone parameter, because of set_timezone in models/management_model.php."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2023-04-10T00:00:00.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://github.com/ahmedalroky/Disclosures/blob/main/apesystems/os_command_injection.md"
            },
            {
              "url": "https://apsystems.com"
            },
            {
              "url": "http://packetstormsecurity.com/files/171775/Altenergy-Power-Control-Software-C1.2.5-Command-Injection.html"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2023-28343",
        "datePublished": "2023-03-14T00:00:00.000Z",
        "dateReserved": "2023-03-14T00:00:00.000Z",
        "dateUpdated": "2025-02-27T15:13:32.712Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…