CVE-2022-40691 (GCVE-0-2022-40691)
Vulnerability from cvelistv5 – Published: 2023-02-07 16:52 – Updated: 2024-08-03 12:21
VLAI
EPSS
VEX
Summary
An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability.
Severity
5.3 (Medium)
SSVC
Exploitation: poc
Automatable: yes
Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-08-01 17:20 UTC
CWE
- CWE-200 - Information Exposure
Assigner
References
Impacted products
3 products
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Moxa | SDS-3008 Series Industrial Ethernet Switch |
Affected:
2.1
|
guessed | |
| moxa | sds-3008_firmware |
Affected:
0 , ≤ 2.1
(custom)
cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:* |
||
| moxa | sds-3008-t_firmware |
Affected:
0 , ≤ 2.1
(custom)
cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:* |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T12:21:46.623Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
},
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621",
"tags": [
"x_transferred"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
},
{
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
"tags": [
"x_transferred"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sds-3008_firmware",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sds-3008-t_firmware",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40691",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T17:20:38.057437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T17:26:19.735Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SDS-3008 Series Industrial Ethernet Switch",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-07T16:52:02.533Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
},
{
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-40691",
"datePublished": "2023-02-07T16:52:02.533Z",
"dateReserved": "2022-09-21T20:53:42.822Z",
"dateUpdated": "2024-08-03T12:21:46.623Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2022-40691",
"date": "2026-09-23",
"epss": "0.01458",
"percentile": "0.72409"
},
"nvd": {
"cve": {
"affected": [
{
"affectedData": [
{
"product": "SDS-3008 Series Industrial Ethernet Switch",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "2.1"
}
]
}
],
"source": "talos-cna@cisco.com"
},
{
"affectedData": [
{
"cpes": [
"cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sds-3008_firmware",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sds-3008-t_firmware",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0"
}
],
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DA5A52AA-CABE-48D5-96AE-5C35DBFC05B0",
"versionEndIncluding": "2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:moxa:sds-3008:-:*:*:*:*:*:*:*",
"matchCriteriaId": "07865F6F-F008-48BB-8FAE-CC397042F4B9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B751F6A7-8555-4080-B278-D7A4E982F726",
"versionEndIncluding": "2.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:moxa:sds-3008-t:-:*:*:*:*:*:*:*",
"matchCriteriaId": "C49175C2-3568-43F5-B75F-E89E3BB41190",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability."
}
],
"id": "CVE-2022-40691",
"lastModified": "2026-06-17T05:01:50.870",
"metrics": {
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "talos-cna@cisco.com",
"type": "Secondary"
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
],
"ssvcV203": [
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"ssvcData": {
"id": "CVE-2022-40691",
"options": [
{
"exploitation": "poc"
},
{
"automatable": "yes"
},
{
"technicalImpact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T17:20:38.057437Z",
"version": "2.0.3"
}
}
]
},
"published": "2023-02-07T17:15:10.330",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "talos-cna@cisco.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T01:36:48+00:00",
"cve": "CVE-2022-40691",
"id": "CVE-2022-40691",
"initial_release_date": "2022-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "CVE-2022-40691",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2022/cve-2022-40691.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-07-31T20:11:54.274Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
}
],
"title": "CVE Program Container"
},
{
"affected": [
{
"cpes": [
"cpe:2.3:o:moxa:sds-3008_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sds-3008_firmware",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"cpes": [
"cpe:2.3:o:moxa:sds-3008-t_firmware:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "sds-3008-t_firmware",
"vendor": "moxa",
"versions": [
{
"lessThanOrEqual": "2.1",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-40691",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-01T17:20:38.057437Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-01T17:26:12.501Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "SDS-3008 Series Industrial Ethernet Switch",
"vendor": "Moxa",
"versions": [
{
"status": "affected",
"version": "2.1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An information disclosure vulnerability exists in the web application functionality of Moxa SDS-3008 Series Industrial Ethernet Switch 2.1. A specially-crafted HTTP request can lead to a disclosure of sensitive information. An attacker can send an HTTP request to trigger this vulnerability."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200: Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-02-07T16:52:02.533Z",
"orgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"shortName": "talos"
},
"references": [
{
"name": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621",
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2022-1621"
},
{
"name": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities",
"url": "https://www.moxa.com/en/support/product-support/security-advisory/sds-3008-series-multiple-web-vulnerabilities"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "b86d76f8-0f8a-4a96-a78d-d8abfc7fc29b",
"assignerShortName": "talos",
"cveId": "CVE-2022-40691",
"datePublished": "2023-02-07T16:52:02.533Z",
"dateReserved": "2022-09-21T20:53:42.822Z",
"dateUpdated": "2024-08-01T17:26:19.735Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Loading…
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.
Loading…