CVE-2021-27414 (GCVE-0-2021-27414)
Vulnerability from cvelistv5 – Published: 2022-03-11 17:54 – Updated: 2025-04-16 16:43- CWE-451 - User Interface (UI) Misrepresentation of Critical Information
| URL | Tags |
|---|---|
| https://www.cisa.gov/uscert/ics/advisories/icsa-2… | x_refsource_CONFIRM |
| https://search.abb.com/library/Download.aspx?Docu… | x_refsource_CONFIRM |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Hitachi ABB Power Grids | Ellipse Enterprise Asset Management (EAM) |
Affected:
unspecified , ≤ 9.0.25
(custom)
|
guessed |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-27414",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:55:39.882978Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T16:43:12.665Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Ellipse Enterprise Asset Management (EAM)",
"vendor": "Hitachi ABB Power Grids",
"versions": [
{
"lessThanOrEqual": "9.0.25",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-451",
"description": "CWE-451 User Interface (UI) Misrepresentation of Critical Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-11T17:54:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends users apply the update as soon as they are able. Ellipse EAM Version 9.0.23 fixes one of the vulnerabilities, and Ellipse EAM Version 9.0.26 fixes both.\n\nHitachi ABB Power Grids published cybersecurity advisory PGVU-PGGA-Ellipse-202027 to give users more information about this issue."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM",
"workarounds": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends following security best practices and firewall configurations to help protect a process control network from attacks originating from an outside the network. Such practices include:\n\n Ensure critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.\n Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.\n Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.\n Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing emails or malicious web pages.\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27414",
"STATE": "PUBLIC",
"TITLE": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ellipse Enterprise Asset Management (EAM)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "9.0.25"
}
]
}
}
]
},
"vendor_name": "Hitachi ABB Power Grids"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Hitachi ABB Power Grids reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-451 User Interface (UI) Misrepresentation of Critical Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "CONFIRM",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
]
},
"solution": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends users apply the update as soon as they are able. Ellipse EAM Version 9.0.23 fixes one of the vulnerabilities, and Ellipse EAM Version 9.0.26 fixes both.\n\nHitachi ABB Power Grids published cybersecurity advisory PGVU-PGGA-Ellipse-202027 to give users more information about this issue."
}
],
"source": {
"discovery": "INTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends following security best practices and firewall configurations to help protect a process control network from attacks originating from an outside the network. Such practices include:\n\n Ensure critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.\n Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.\n Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.\n Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing emails or malicious web pages.\n"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27414",
"datePublished": "2022-03-11T17:54:00.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:43:12.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2021-27414",
"date": "2026-11-12",
"epss": "0.00573",
"percentile": "0.47842"
},
"nvd": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hitachienergy:ellipse_enterprise_asset_management:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACF7B46F-8E2C-46C4-98B2-5F567CB6816F",
"versionEndExcluding": "9.0.23",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."
},
{
"lang": "es",
"value": "Un atacante podr\u00eda enga\u00f1ar a un usuario de Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versiones anteriores a 9.0.25, incluy\u00e9ndola, para que visite un sitio web malicioso que haga pasarse por una p\u00e1gina de inicio de sesi\u00f3n de la aplicaci\u00f3n Ellipse y consiga las credenciales de autenticaci\u00f3n"
}
],
"id": "CVE-2021-27414",
"lastModified": "2024-11-21T05:57:56.577",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 3.4,
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-03-11T18:15:12.010",
"references": [
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"source": "ics-cert@hq.dhs.gov",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
}
],
"sourceIdentifier": "ics-cert@hq.dhs.gov",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-451"
}
],
"source": "ics-cert@hq.dhs.gov",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-1021"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"redhat_vex": {
"current_release_date": "2025-05-29T04:01:28+00:00",
"cve": "CVE-2021-27414",
"id": "CVE-2021-27414",
"initial_release_date": "2021-01-01T00:00:00+00:00",
"product_status:known_not_affected": "1",
"source": "Red Hat CSAF VEX",
"status": "final",
"title": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM",
"url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-27414.json",
"version": "3"
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T20:48:16.843Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-27414",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-16T15:55:39.882978Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-16T15:55:42.365Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Ellipse Enterprise Asset Management (EAM)",
"vendor": "Hitachi ABB Power Grids",
"versions": [
{
"lessThanOrEqual": "9.0.25",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids reported these vulnerabilities to CISA."
}
],
"descriptions": [
{
"lang": "en",
"value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-451",
"description": "CWE-451 User Interface (UI) Misrepresentation of Critical Information",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-11T17:54:00.000Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
],
"solutions": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends users apply the update as soon as they are able. Ellipse EAM Version 9.0.23 fixes one of the vulnerabilities, and Ellipse EAM Version 9.0.26 fixes both.\n\nHitachi ABB Power Grids published cybersecurity advisory PGVU-PGGA-Ellipse-202027 to give users more information about this issue."
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM",
"workarounds": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends following security best practices and firewall configurations to help protect a process control network from attacks originating from an outside the network. Such practices include:\n\n Ensure critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.\n Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.\n Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.\n Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing emails or malicious web pages.\n"
}
],
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "ics-cert@hq.dhs.gov",
"ID": "CVE-2021-27414",
"STATE": "PUBLIC",
"TITLE": "User interface misrepresentation of critical information in Hitachi ABB Power Grids Ellipse EAM"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Ellipse Enterprise Asset Management (EAM)",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_value": "9.0.25"
}
]
}
}
]
},
"vendor_name": "Hitachi ABB Power Grids"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Hitachi ABB Power Grids reported these vulnerabilities to CISA."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An attacker could trick a user of Hitachi ABB Power Grids Ellipse Enterprise Asset Management (EAM) versions prior to and including 9.0.25 into visiting a malicious website posing as a login page for the Ellipse application and gather authentication credentials."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-451 User Interface (UI) Misrepresentation of Critical Information"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01",
"refsource": "CONFIRM",
"url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-061-01"
},
{
"name": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch",
"refsource": "CONFIRM",
"url": "https://search.abb.com/library/Download.aspx?DocumentID=9AKK107991A7777\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=Launch"
}
]
},
"solution": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends users apply the update as soon as they are able. Ellipse EAM Version 9.0.23 fixes one of the vulnerabilities, and Ellipse EAM Version 9.0.26 fixes both.\n\nHitachi ABB Power Grids published cybersecurity advisory PGVU-PGGA-Ellipse-202027 to give users more information about this issue."
}
],
"source": {
"discovery": "INTERNAL"
},
"work_around": [
{
"lang": "en",
"value": "Hitachi ABB Power Grids recommends following security best practices and firewall configurations to help protect a process control network from attacks originating from an outside the network. Such practices include:\n\n Ensure critical applications and systems are physically protected from direct access by unauthorized personnel, have no direct connections to the Internet, and are separated from other networks by means of a firewall.\n Firewalls should be configured to have the minimum number of ports exposed and open ports should be justified and documented.\n Critical systems should not be used for Internet surfing, instant messaging, or receiving e-mails.\n Portable computers and removable storage media should be carefully scanned for viruses before they are connected to a control system.\n It is important to implement robust security awareness training to ensure users are able to identify common attacks or content such as phishing emails or malicious web pages.\n"
}
]
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2021-27414",
"datePublished": "2022-03-11T17:54:00.000Z",
"dateReserved": "2021-02-19T00:00:00.000Z",
"dateUpdated": "2025-04-16T16:43:12.665Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline
Sightings and recorded dates, grouped by day · UTC
How durations are calculated
Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.
Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.
Loading timeline…
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.