CVE-2021-21503 (GCVE-0-2021-21503)

Vulnerability from cvelistv5 – Published: 2021-03-08 21:44 – Updated: 2024-09-17 03:43
VLAI
Summary
PowerScale OneFS 8.1.2,8.2.2 and 9.1.0 contains an improper input sanitization issue in a command. The Compadmin user could potentially exploit this vulnerability, leading to potential privileges escalation.
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
References
Impacted products
Vendor Product Version CPE status
Dell PowerScale OneFS Affected: unspecified , < 8.1.2, 8.2.2,9.1.0.x,EMPIRE (9.2.0), GOTHAM (custom)
guessed Create a notification for this product.
Date Public
2021-02-26 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T18:16:22.603Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/000183717"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "PowerScale OneFS",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "8.1.2, 8.2.2,9.1.0.x,EMPIRE (9.2.0), GOTHAM",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2021-02-26T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "PowerScale OneFS 8.1.2,8.2.2 and 9.1.0 contains an improper input sanitization issue in a command. The Compadmin user could potentially exploit this vulnerability, leading to potential privileges escalation."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-03-08T21:44:46.000Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.dell.com/support/kbdoc/000183717"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "secure@dell.com",
          "DATE_PUBLIC": "2021-02-26",
          "ID": "CVE-2021-21503",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "PowerScale OneFS",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1.2, 8.2.2,9.1.0.x,EMPIRE (9.2.0), GOTHAM"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Dell"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "PowerScale OneFS 8.1.2,8.2.2 and 9.1.0 contains an improper input sanitization issue in a command. The Compadmin user could potentially exploit this vulnerability, leading to potential privileges escalation."
            }
          ]
        },
        "impact": {
          "cvss": {
            "baseScore": 7.8,
            "baseSeverity": "High",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-78: Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.dell.com/support/kbdoc/000183717",
              "refsource": "MISC",
              "url": "https://www.dell.com/support/kbdoc/000183717"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2021-21503",
    "datePublished": "2021-03-08T21:44:46.106Z",
    "dateReserved": "2021-01-04T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:43:52.638Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-21503",
      "date": "2026-09-22",
      "epss": "0.00309",
      "percentile": "0.23973"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:8.1.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "575793FB-6E18-4A7F-B689-EA4FB7904DFE",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:8.2.2:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FF89B320-6D5A-4E46-A1FA-FCDB31F325C4",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:o:dell:emc_powerscale_onefs:9.1.0:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E08AB5B6-818B-4666-8DF8-32030BBE06A1",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "PowerScale OneFS 8.1.2,8.2.2 and 9.1.0 contains an improper input sanitization issue in a command. The Compadmin user could potentially exploit this vulnerability, leading to potential privileges escalation."
          },
          {
            "lang": "es",
            "value": "PowerScale OneFS versiones 8.1.2, 8.2.2 y 9.1.0, contiene un problema de saneamiento de entrada inapropiado en un comando.\u0026#xa0;El usuario de Compadmin podr\u00eda aprovechar esta vulnerabilidad, conllevando a una posible escalada de privilegios"
          }
        ],
        "id": "CVE-2021-21503",
        "lastModified": "2024-11-21T05:48:29.730",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "LOCAL",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 4.6,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "security_alert@emc.com",
              "type": "Secondary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "LOCAL",
                "availabilityImpact": "HIGH",
                "baseScore": 7.8,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "LOW",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 1.8,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-03-08T22:15:13.783",
        "references": [
          {
            "source": "security_alert@emc.com",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/kbdoc/000183717"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Vendor Advisory"
            ],
            "url": "https://www.dell.com/support/kbdoc/000183717"
          }
        ],
        "sourceIdentifier": "security_alert@emc.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "security_alert@emc.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T14:56:50+00:00",
      "cve": "CVE-2021-21503",
      "id": "CVE-2021-21503",
      "initial_release_date": "2021-02-26T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-21503",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-21503.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…