CVE-2021-20157 (GCVE-0-2021-20157)

Vulnerability from cvelistv5 – Published: 2021-12-30 21:31 – Updated: 2024-08-03 17:30
VLAI
Summary
It is possible for an unauthenticated, malicious user to force the device to reboot due to a hidden administrative command.
CWE
  • Denial of Service
References
Impacted products
Vendor Product Version CPE status
n/a Trendnet AC2600 TEW-827DRU Affected: 2.08B01
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T17:30:07.471Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tenable.com/security/research/tra-2021-54"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Trendnet AC2600 TEW-827DRU",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "2.08B01"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "It is possible for an unauthenticated, malicious user to force the device to reboot due to a hidden administrative command."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "Denial of Service",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-12-30T21:31:03.000Z",
        "orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
        "shortName": "tenable"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tenable.com/security/research/tra-2021-54"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "vulnreport@tenable.com",
          "ID": "CVE-2021-20157",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Trendnet AC2600 TEW-827DRU",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.08B01"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "It is possible for an unauthenticated, malicious user to force the device to reboot due to a hidden administrative command."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Denial of Service"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tenable.com/security/research/tra-2021-54",
              "refsource": "MISC",
              "url": "https://www.tenable.com/security/research/tra-2021-54"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
    "assignerShortName": "tenable",
    "cveId": "CVE-2021-20157",
    "datePublished": "2021-12-30T21:31:03.000Z",
    "dateReserved": "2020-12-17T00:00:00.000Z",
    "dateUpdated": "2024-08-03T17:30:07.471Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2021-20157",
      "date": "2026-09-27",
      "epss": "0.01549",
      "percentile": "0.74045"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:trendnet:tew-827dru_firmware:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E8A7ED82-21A9-435F-B092-7AAFA135FE22",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:trendnet:tew-827dru:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "4079F0DD-CD82-4315-934F-3F49F9823760",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "It is possible for an unauthenticated, malicious user to force the device to reboot due to a hidden administrative command."
          },
          {
            "lang": "es",
            "value": "Es posible que un usuario malicioso no autenticado fuerce el reinicio del dispositivo debido a un comando administrativo oculto."
          }
        ],
        "id": "CVE-2021-20157",
        "lastModified": "2024-11-21T05:46:01.973",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 7.8,
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 6.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "NONE",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-12-30T22:15:08.940",
        "references": [
          {
            "source": "vulnreport@tenable.com",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.tenable.com/security/research/tra-2021-54"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.tenable.com/security/research/tra-2021-54"
          }
        ],
        "sourceIdentifier": "vulnreport@tenable.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "NVD-CWE-noinfo"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    },
    "redhat_vex": {
      "current_release_date": "2026-03-27T15:03:22+00:00",
      "cve": "CVE-2021-20157",
      "id": "CVE-2021-20157",
      "initial_release_date": "2021-01-01T00:00:00+00:00",
      "product_status:known_not_affected": "1",
      "source": "Red Hat CSAF VEX",
      "status": "final",
      "title": "CVE-2021-20157",
      "url": "https://security.access.redhat.com/data/csaf/v2/vex/2021/cve-2021-20157.json",
      "version": "3"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…