CVE-2020-25205 (GCVE-0-2020-25205)

Vulnerability from cvelistv5 – Published: 2021-07-20 18:45 – Updated: 2024-08-04 15:33
VLAI
Summary
The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device's filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message presented to unauthenticated users who visit the login page for the web console. This vulnerability does not occur in the older 1.5.x firmware versions.
CWE
  • n/a
Assigner
mitre CNA under the mitre root
CNA scorecard E 29/100 over 2146 records in the last 180 days details
References
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:33:04.419Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://labs.f-secure.com/advisories/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://labs.f-secure.com/advisories/mimosa-ptp-devices-multiple-vulnerabilities/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device\u0027s filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message presented to unauthenticated users who visit the login page for the web console. This vulnerability does not occur in the older 1.5.x firmware versions."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-07-20T18:45:21.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://labs.f-secure.com/advisories/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://labs.f-secure.com/advisories/mimosa-ptp-devices-multiple-vulnerabilities/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-25205",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device\u0027s filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message presented to unauthenticated users who visit the login page for the web console. This vulnerability does not occur in the older 1.5.x firmware versions."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://labs.f-secure.com/advisories/",
              "refsource": "MISC",
              "url": "https://labs.f-secure.com/advisories/"
            },
            {
              "name": "https://labs.f-secure.com/advisories/mimosa-ptp-devices-multiple-vulnerabilities/",
              "refsource": "MISC",
              "url": "https://labs.f-secure.com/advisories/mimosa-ptp-devices-multiple-vulnerabilities/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-25205",
    "datePublished": "2021-07-20T18:45:21.000Z",
    "dateReserved": "2020-09-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T15:33:04.419Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-25205",
      "date": "2026-11-13",
      "epss": "0.00905",
      "percentile": "0.60347"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mimosa:b5_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8F0CE000-9BD3-4EA6-B98B-F58FC97FC5BE",
                    "versionEndIncluding": "2.8.0.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mimosa:b5:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "AB6E4730-E018-43B4-827B-6266EECF81A8",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mimosa:b5c_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "C203C9BF-6730-4E5C-A855-895BFD9E199C",
                    "versionEndIncluding": "2.8.0.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mimosa:b5c:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B92406E6-A9B4-4070-B307-C341F770EF43",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:mimosa:c5c_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "E5DF58CB-D5CA-4924-A7C4-1A24CAD33F4A",
                    "versionEndIncluding": "2.8.0.3",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:mimosa:c5c:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B2435693-7699-4432-BC83-F31D967E181F",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The web console for Mimosa B5, B5c, and C5x firmware through 2.8.0.2 is vulnerable to stored XSS in the set_banner() function of /var/www/core/controller/index.php. An unauthenticated attacker may set the contents of the /mnt/jffs2/banner.txt file, stored on the device\u0027s filesystem, to contain arbitrary JavaScript. The file contents are then used as part of a welcome/banner message presented to unauthenticated users who visit the login page for the web console. This vulnerability does not occur in the older 1.5.x firmware versions."
          },
          {
            "lang": "es",
            "value": "La consola web para el firmware Mimosa B5, B5c y C5x versiones hasta 2.8.0.2, es vulnerable a un ataque de tipo XSS almacenado en la funci\u00f3n set_banner() del archivo /var/www/core/controller/index.php. Un atacante no autenticado puede ajustar el contenido del archivo /mnt/jffs2/banner.txt, almacenado en el sistema de archivos del dispositivo, para que contenga JavaScript arbitrario. El contenido del archivo es usado entonces como parte de un mensaje de welcome/banner presentado a usuarios no autenticados que visitan la p\u00e1gina de inicio de sesi\u00f3n de la consola web. Esta vulnerabilidad no ocurre en las versiones de firmware 1.5.x m\u00e1s antiguas"
          }
        ],
        "id": "CVE-2020-25205",
        "lastModified": "2024-11-21T05:17:38.623",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 2.7,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2021-07-20T19:15:09.563",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://labs.f-secure.com/advisories/"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://labs.f-secure.com/advisories/mimosa-ptp-devices-multiple-vulnerabilities/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://labs.f-secure.com/advisories/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://labs.f-secure.com/advisories/mimosa-ptp-devices-multiple-vulnerabilities/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-79"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Drag nodes to arrange them. Double-click a related vulnerability to open it, or a source to visit its link. The Physics button on the left tunes the layout and the simulation; the legend at the bottom left hides or shows nodes by kind and by sighting type.

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Vulnerability timeline

Sightings and recorded dates, grouped by day · UTC

JSON
How durations are calculated

Following the VTEM framework (Black Hat USA 2015), time to patch starts when the vendor or a coordinator was informed, total time to patch at discovery, and disclosure to patch at public disclosure; vendor response time runs from the report to its acknowledgement. Time to exploit and time unpatched start at the earliest discovery or report, falling back to public disclosure. Unpatched time ends at the first recorded patch, or the calculation time when no patch is recorded. Exploitation to patch shows the interval between those two events; a published proof of concept is a public exploit, not exploitation.

Each result shows its source dates. A negative interval means the end event came first; when date-only inputs leave the order open, the result says so. Date-only inputs are approximate. The earliest evidence wins: KEV report dates and sightings are labelled as such. Records describing another vulnerability are listed but never calculated from, and a PoC alone does not establish exploitation. Missing patch evidence does not prove that no patch exists. Filters below change the event list only.

Events included in the timeline

Loading timeline…


    Loading…

    Loading…

    Loading…

    Related by attack behaviour

    Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.