GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2020-24987 (GCVE-0-2020-24987)

Vulnerability from cvelistv5 – Published: 2020-09-04 19:24 – Updated: 2024-08-04 15:26
VLAI
Summary
Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to "radius".
CWE
  • n/a
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:26:09.361Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.tendacn.com/en/product/AC18.html"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://cwe.mitre.org/data/definitions/287.html"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\"."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-07-10T20:20:05.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.tendacn.com/en/product/AC18.html"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://cwe.mitre.org/data/definitions/287.html"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-24987",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\"."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.tendacn.com/en/product/AC18.html",
              "refsource": "MISC",
              "url": "https://www.tendacn.com/en/product/AC18.html"
            },
            {
              "name": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing",
              "refsource": "MISC",
              "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing"
            },
            {
              "name": "https://cwe.mitre.org/data/definitions/287.html",
              "refsource": "MISC",
              "url": "https://cwe.mitre.org/data/definitions/287.html"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-24987",
    "datePublished": "2020-09-04T19:24:39.000Z",
    "dateReserved": "2020-08-28T00:00:00.000Z",
    "dateUpdated": "2024-08-04T15:26:09.361Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-24987",
      "date": "2026-09-20",
      "epss": "0.03104",
      "percentile": "0.87176"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "5798E4A8-6F1D-45DB-A253-88033163218C",
                    "versionEndIncluding": "v15.03.05.05_en",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          },
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tendacn:ac18_firmware:*:*:*:*:*:*:*:*",
                    "matchCriteriaId": "677F497C-FD6E-4A6C-A7A9-281E5453A78B",
                    "versionEndIncluding": "v15.03.05.19\\(6318\\)_cn",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tendacn:ac18:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "FCF0F551-6E6C-48D6-9C2A-740B84AF0349",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "Tenda AC18 Router through V15.03.05.05_EN and through V15.03.05.19(6318) CN devices could cause a remote code execution due to incorrect authentication handling of vulnerable logincheck() function in /usr/lib/lua/ngx_authserver/ngx_wdas.lua file if the administrator UI Interface is set to \"radius\"."
          },
          {
            "lang": "es",
            "value": "El enrutador Tenda AC18 versiones hasta V15.03.05.05_EN y versiones hasta V15.03.05.19(6318), los dispositivos CN podr\u00edan causar una ejecuci\u00f3n remota de c\u00f3digo debido a un manejo de autenticaci\u00f3n incorrecto de la funci\u00f3n vulnerable logincheck() en el archivo /usr/lib/lua/ngx_authserver/ngx_wdas.lua si la interfaz de usuario del administrador est\u00e1 configurada en \"radius\""
          }
        ],
        "id": "CVE-2020-24987",
        "lastModified": "2024-11-21T05:16:23.240",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "PARTIAL",
                "baseScore": 6.8,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 6.4,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-09-04T20:15:13.480",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cwe.mitre.org/data/definitions/287.html"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Broken Link"
            ],
            "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Product",
              "Vendor Advisory"
            ],
            "url": "https://www.tendacn.com/en/product/AC18.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://cwe.mitre.org/data/definitions/287.html"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Broken Link"
            ],
            "url": "https://drive.google.com/file/d/1iqpr0EofOBC6kCq2USTOBPRlJu_naFjQ/view?usp=sharing"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Product",
              "Vendor Advisory"
            ],
            "url": "https://www.tendacn.com/en/product/AC18.html"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…