CVE-2020-13174 (GCVE-0-2020-13174)

Vulnerability from cvelistv5 – Published: 2020-08-11 17:31 – Updated: 2024-08-04 12:11
VLAI
Summary
The web server in the Teradici Managament console versions 20.04 and 20.01.1 did not properly set the X-Frame-Options HTTP header, which could allow an attacker to trick a user into clicking a malicious link via clickjacking.
CWE
Assigner
References
Impacted products
Vendor Product Version CPE status
n/a - Management Console Affected: 20.04 and 20.01.1
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T12:11:19.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://advisory.teradici.com/security-advisories/58/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "- Management Console",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "20.04 and 20.01.1"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The web server in the Teradici Managament console versions 20.04 and 20.01.1 did not properly set the X-Frame-Options HTTP header, which could allow an attacker to trick a user into clicking a malicious link via clickjacking."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1021",
              "description": "Clickjacking (CWE-1021)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-08-11T17:31:57.000Z",
        "orgId": "ba3c294d-a544-4fff-ad44-2de7c7bbb6be",
        "shortName": "Teradici"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://advisory.teradici.com/security-advisories/58/"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "security@teradici.com",
          "ID": "CVE-2020-13174",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "- Management Console",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "20.04 and 20.01.1"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The web server in the Teradici Managament console versions 20.04 and 20.01.1 did not properly set the X-Frame-Options HTTP header, which could allow an attacker to trick a user into clicking a malicious link via clickjacking."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Clickjacking (CWE-1021)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://advisory.teradici.com/security-advisories/58/",
              "refsource": "MISC",
              "url": "https://advisory.teradici.com/security-advisories/58/"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ba3c294d-a544-4fff-ad44-2de7c7bbb6be",
    "assignerShortName": "Teradici",
    "cveId": "CVE-2020-13174",
    "datePublished": "2020-08-11T17:31:57.000Z",
    "dateReserved": "2020-05-19T00:00:00.000Z",
    "dateUpdated": "2024-08-04T12:11:19.389Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2020-13174",
      "date": "2026-09-24",
      "epss": "0.00661",
      "percentile": "0.49428"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:a:teradici:pcoip_management_console:20.01.1:*:*:*:*:*:*:*",
                    "matchCriteriaId": "78283EF0-FF09-4B16-AC47-880321FA19F1",
                    "vulnerable": true
                  },
                  {
                    "criteria": "cpe:2.3:a:teradici:pcoip_management_console:20.04:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B9C100F3-9C76-4BE8-94CA-C9E7BE70FBD8",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ]
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The web server in the Teradici Managament console versions 20.04 and 20.01.1 did not properly set the X-Frame-Options HTTP header, which could allow an attacker to trick a user into clicking a malicious link via clickjacking."
          },
          {
            "lang": "es",
            "value": "El servidor web en la consola de Teradici Managament versiones 20.04 y 20.01.1, no configur\u00f3 apropiadamente el encabezado HTTP X-Frame-Options, lo que podr\u00eda permitir a un atacante enga\u00f1ar a un usuario para que haga clic en un enlace malicioso mediante un secuestro de clic"
          }
        ],
        "id": "CVE-2020-13174",
        "lastModified": "2024-11-21T05:00:48.230",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "MEDIUM",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 4.3,
                "confidentialityImpact": "NONE",
                "integrityImpact": "PARTIAL",
                "vectorString": "AV:N/AC:M/Au:N/C:N/I:P/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 8.6,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": true
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 6.1,
                "baseSeverity": "MEDIUM",
                "confidentialityImpact": "LOW",
                "integrityImpact": "LOW",
                "privilegesRequired": "NONE",
                "scope": "CHANGED",
                "userInteraction": "REQUIRED",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:C/C:L/I:L/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 2.8,
              "impactScore": 2.7,
              "source": "nvd@nist.gov",
              "type": "Primary"
            }
          ]
        },
        "published": "2020-08-11T18:15:12.393",
        "references": [
          {
            "source": "security@teradici.com",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://advisory.teradici.com/security-advisories/58/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Patch",
              "Vendor Advisory"
            ],
            "url": "https://advisory.teradici.com/security-advisories/58/"
          }
        ],
        "sourceIdentifier": "security@teradici.com",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-1021"
              }
            ],
            "source": "security@teradici.com",
            "type": "Secondary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-1021"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          }
        ]
      }
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…