GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2020-10987 (GCVE-0-2020-10987)

Vulnerability from cvelistv5 – Published: 2020-07-13 18:46 – Updated: 2025-10-21 23:35
VLAI CISA Previdian
Summary
The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter.
SSVC
Exploitation: active Automatable: yes Technical Impact: total
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2025-02-04 19:51 UTC
CWE
  • n/a
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
References
CISA
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2020-10987

Status: Confirmed

Status Updated: 2021-11-03 00:00 UTC

Exploited: Yes


Timestamps
First Seen: 2021-11-03
Asserted: 2021-11-03

Scope
Notes: KEV entry: Tenda AC1900 Router AC15 Model Remote Code Execution Vulnerability | Affected: Tenda / AC1900 Router AC15 Model | Description: Tenda AC1900 Router AC15 Model contains an unspecified vulnerability that allows remote attackers to execute system commands via the deviceName POST parameter. | Required action: Apply updates per vendor instructions. | Due date: 2022-05-03 | Known ransomware campaign use (KEV): Unknown | Notes (KEV): https://nvd.nist.gov/vuln/detail/CVE-2020-10987

Evidence

Type: Vendor Report

Signal: Successful Exploitation

Confidence: 80%

Source: cisa-kev


Details
Cwes CWE-78
Feed CISA Known Exploited Vulnerabilities Catalog
Product AC1900 Router AC15 Model
Due Date 2022-05-03
Date Added 2021-11-03
Vendorproject Tenda
Vulnerabilityname Tenda AC1900 Router AC15 Model Remote Code Execution Vulnerability
Knownransomwarecampaignuse Unknown

References

Created: 2026-02-02 13:26 UTC | Updated: 2026-02-06 07:53 UTC
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant

Vulnerability ID: CVE-2020-10987

Status: Confirmed

Status Updated: 2021-11-03 00:00 UTC

Exploited: Yes


Timestamps
First Seen: 2021-11-03
Asserted: 2021-11-03

Scope
Notes: KEVIntel entry: The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the... | Affected: Tenda / AC15 AC1900 | CVSS: 9.8 (CRITICAL) | Used in malware: unknown | Not yet in CISA KEV: False

Evidence

Type: Public Report

Signal: Successful Exploitation

Confidence: 70%

Source: kevintel


Details
Feed KEVIntel (kevintel.com)
Title The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the...
Vendor Tenda
Product AC15 AC1900
Added Date 2021-11-03T00:00:00.000Z
Cvss Score 9.8
Epss Score None
Cvss Severity CRITICAL
Epss Percentile None
Used In Malware unknown
Ahead Of Cisa Kev None
Not Yet In Cisa Kev False

References

Created: 2026-06-23 11:13 UTC | Updated: 2026-06-23 11:13 UTC
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T11:21:14.161Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.ise.io/research/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "HIGH",
              "baseScore": 9.8,
              "baseSeverity": "CRITICAL",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "HIGH",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2020-10987",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-02-04T19:51:03.118238Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2021-11-03",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2020-10987"
              },
              "type": "kev"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-78",
                "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:35:40.165Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2020-10987"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2021-11-03T00:00:00.000Z",
            "value": "CVE-2020-10987 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-07-13T18:46:12.000Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.ise.io/research/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "cve@mitre.org",
          "ID": "CVE-2020-10987",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.ise.io/research/",
              "refsource": "MISC",
              "url": "https://www.ise.io/research/"
            },
            {
              "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68",
              "refsource": "MISC",
              "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2020-10987",
    "datePublished": "2020-07-13T18:46:12.000Z",
    "dateReserved": "2020-03-26T00:00:00.000Z",
    "dateUpdated": "2025-10-21T23:35:40.165Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "cisa_known_exploited": {
      "cveID": "CVE-2020-10987",
      "cwes": [
        "CWE-78"
      ],
      "dateAdded": "2021-11-03",
      "dueDate": "2022-05-03",
      "forensicTriage": "No",
      "knownRansomwareCampaignUse": "Unknown",
      "notes": "https://nvd.nist.gov/vuln/detail/CVE-2020-10987",
      "product": "AC1900 Router AC15 Model",
      "requiredAction": "Apply updates per vendor instructions.",
      "shortDescription": "Tenda AC1900 Router AC15 Model contains an unspecified vulnerability that allows remote attackers to execute system commands via the deviceName POST parameter.",
      "vendorProject": "Tenda",
      "vulnerabilityName": "Tenda AC1900 Router AC15 Model Remote Code Execution Vulnerability"
    },
    "epss": {
      "cve": "CVE-2020-10987",
      "date": "2026-09-19",
      "epss": "0.7981",
      "percentile": "0.99591"
    },
    "nvd": {
      "cve": {
        "cisaActionDue": "2022-05-03",
        "cisaExploitAdd": "2021-11-03",
        "cisaRequiredAction": "Apply updates per vendor instructions.",
        "cisaVulnerabilityName": "Tenda AC1900 Router AC15 Model Remote Code Execution Vulnerability",
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:tenda:ac15_firmware:15.03.05.19:*:*:*:*:*:*:*",
                    "matchCriteriaId": "A14A19EE-FB4E-4371-AC85-1401EB78B16D",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:tenda:ac15:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "B73E7C1C-F121-486A-8B15-E97EA0C219A5",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter."
          },
          {
            "lang": "es",
            "value": "El endpoint goform/setUsbUnload de Tenda AC15 AC1900 versi\u00f3n 15.03.05.19, permite a atacantes remotos ejecutar comandos del sistema arbitrarios por medio del par\u00e1metro POST deviceName"
          }
        ],
        "id": "CVE-2020-10987",
        "lastModified": "2025-11-07T19:32:57.680",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "HIGH",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "COMPLETE",
                "baseScore": 10.0,
                "confidentialityImpact": "COMPLETE",
                "integrityImpact": "COMPLETE",
                "vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 10.0,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "HIGH",
                "baseScore": 9.8,
                "baseSeverity": "CRITICAL",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "HIGH",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 5.9,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ]
        },
        "published": "2020-07-13T19:15:12.207",
        "references": [
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.ise.io/research/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Third Party Advisory"
            ],
            "url": "https://www.ise.io/research/"
          },
          {
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "tags": [
              "US Government Resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2020-10987"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Analyzed",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-78"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-04T11:21:14.161Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://www.ise.io/research/"
              },
              {
                "tags": [
                  "x_refsource_MISC",
                  "x_transferred"
                ],
                "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "HIGH",
                  "baseScore": 9.8,
                  "baseSeverity": "CRITICAL",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "HIGH",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2020-10987",
                    "options": [
                      {
                        "Exploitation": "active"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "total"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2025-02-04T19:51:03.118238Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              },
              {
                "other": {
                  "content": {
                    "dateAdded": "2021-11-03",
                    "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2020-10987"
                  },
                  "type": "kev"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-78",
                    "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2025-02-04T19:50:51.331Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "references": [
              {
                "tags": [
                  "government-resource"
                ],
                "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2020-10987"
              }
            ],
            "timeline": [
              {
                "lang": "en",
                "time": "2021-11-03T00:00:00.000Z",
                "value": "CVE-2020-10987 added to CISA KEV"
              }
            ],
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "descriptions": [
            {
              "lang": "en",
              "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2020-07-13T18:46:12.000Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://www.ise.io/research/"
            },
            {
              "tags": [
                "x_refsource_MISC"
              ],
              "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
            }
          ],
          "x_legacyV4Record": {
            "CVE_data_meta": {
              "ASSIGNER": "cve@mitre.org",
              "ID": "CVE-2020-10987",
              "STATE": "PUBLIC"
            },
            "affects": {
              "vendor": {
                "vendor_data": [
                  {
                    "product": {
                      "product_data": [
                        {
                          "product_name": "n/a",
                          "version": {
                            "version_data": [
                              {
                                "version_value": "n/a"
                              }
                            ]
                          }
                        }
                      ]
                    },
                    "vendor_name": "n/a"
                  }
                ]
              }
            },
            "data_format": "MITRE",
            "data_type": "CVE",
            "data_version": "4.0",
            "description": {
              "description_data": [
                {
                  "lang": "eng",
                  "value": "The goform/setUsbUnload endpoint of Tenda AC15 AC1900 version 15.03.05.19 allows remote attackers to execute arbitrary system commands via the deviceName POST parameter."
                }
              ]
            },
            "problemtype": {
              "problemtype_data": [
                {
                  "description": [
                    {
                      "lang": "eng",
                      "value": "n/a"
                    }
                  ]
                }
              ]
            },
            "references": {
              "reference_data": [
                {
                  "name": "https://www.ise.io/research/",
                  "refsource": "MISC",
                  "url": "https://www.ise.io/research/"
                },
                {
                  "name": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68",
                  "refsource": "MISC",
                  "url": "https://blog.securityevaluators.com/tenda-ac1900-vulnerabilities-discovered-and-exploited-e8e26aa0bc68"
                }
              ]
            }
          }
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2020-10987",
        "datePublished": "2020-07-13T18:46:12.000Z",
        "dateReserved": "2020-03-26T00:00:00.000Z",
        "dateUpdated": "2025-10-21T23:35:40.165Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…