CVE-2019-3929 (GCVE-0-2019-3929)
Vulnerability from cvelistv5 – Published: 2019-04-30 20:21 – Updated: 2025-10-21 23:45- CWE-79 - OS Command Injection
| URL | Tags |
|---|---|
| https://www.tenable.com/security/research/tra-2019-20 | x_refsource_MISC |
| https://www.exploit-db.com/exploits/46786/ | exploitx_refsource_EXPLOIT-DB |
| http://packetstormsecurity.com/files/152715/Barco… | x_refsource_MISC |
| http://packetstormsecurity.com/files/155948/Barco… | x_refsource_MISC |
| https://www.cisa.gov/known-exploited-vulnerabilit… | government-resource |
| Vendor | Product | Version | CPE status | |
|---|---|---|---|---|
| Crestron | Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. |
Affected:
Crestron AM-100 firmware 1.6.0.2
Affected: Crestron AM-101 firmware 2.7.0.1 Affected: Barco wePresent WiPG-1000P firmware 2.3.0.10 Affected: Barco wePresent WiPG-1600W before firmware 2.4.1.19 Affected: Extron ShareLink 200/250 firmware 2.0.3.4 Affected: Teq AV IT WIPS710 firmware 1.1.0.7 Affected: SHARP PN-L703WA firmware 1.4.2.3 Affected: Optoma WPS-Pro firmware 1.0.0.5 Affected: Blackbox HD WPS firmware 1.0.0.5 Affected: InFocus LiteShow3 firmware 1.0.16 Affected: and InFocus LiteShow4 2.0.0.7 |
guessed |
CISA
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Vendor Report
Signal: Successful Exploitation
Confidence: 80%
Source: cisa-kev
Details
| Cwes | CWE-79 |
|---|---|
| Feed | CISA Known Exploited Vulnerabilities Catalog |
| Product | Multiple Products |
| Due Date | 2022-05-06 |
| Date Added | 2022-04-15 |
| Vendorproject | Crestron |
| Vulnerabilityname | Crestron Multiple Products Command Injection Vulnerability |
| Knownransomwarecampaignuse | Unknown |
References
Shadowserver
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Characteristics
Timestamps
Scope
Evidence
Type: Honeypot
Signal: In The Wild Attempts
Confidence: 70%
Source: shadowserver
Details
| 1D | 3 |
|---|---|
| Iot | yes |
| Feed | Shadowserver Foundation honeypot/exploited-vulnerabilities |
| Type | http-scan |
| Class | embedded-system |
| 7D Avg | 3 |
| Vendor | Barco/AWIND |
| 30D Avg | 1 |
| 90D Avg | 1 |
| Product | Barco/AWIND OEM |
| Cisa Kev | yes |
| Connections | 5 |
| Observation Date | 2026-09-07 |
| Vulnerability Class | CVSS |
| Vulnerability Score | 9.8 |
| Vulnerability Severity | Critical |
References
Previdian
Known Exploited Vulnerability - GCVE BCP-07 Compliant
Exploited: Yes
Timestamps
Scope
Evidence
Type: Public Report
Signal: Successful Exploitation
Confidence: 70%
Source: kevintel
Details
| Feed | KEVIntel (kevintel.com) |
|---|---|
| Title | The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W... |
| Vendor | Crestron |
| Product | Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4. |
| Added Date | 2022-04-15T00:00:00.000Z |
| Cvss Score | 9.8 |
| Epss Score | None |
| Cvss Severity | CRITICAL |
| Epss Percentile | None |
| Used In Malware | unknown |
| Ahead Of Cisa Kev | None |
| Not Yet In Cisa Kev | False |
References
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-3929",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T20:26:27.910638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2022-04-15",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-21T23:45:38.287Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-04-15T00:00:00.000Z",
"value": "CVE-2019-3929 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "Crestron AM-100 firmware 1.6.0.2"
},
{
"status": "affected",
"version": "Crestron AM-101 firmware 2.7.0.1"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"status": "affected",
"version": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"status": "affected",
"version": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"status": "affected",
"version": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"status": "affected",
"version": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"status": "affected",
"version": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"status": "affected",
"version": "InFocus LiteShow3 firmware 1.0.16"
},
{
"status": "affected",
"version": "and InFocus LiteShow4 2.0.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-14T17:06:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"version": {
"version_data": [
{
"version_value": "Crestron AM-100 firmware 1.6.0.2"
},
{
"version_value": "Crestron AM-101 firmware 2.7.0.1"
},
{
"version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"version_value": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"version_value": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"version_value": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"version_value": "InFocus LiteShow3 firmware 1.0.16"
},
{
"version_value": "and InFocus LiteShow4 2.0.0.7"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"name": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"name": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3929",
"datePublished": "2019-04-30T20:21:09.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:45:38.287Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"cisa_known_exploited": {
"cveID": "CVE-2019-3929",
"cwes": [
"CWE-79"
],
"dateAdded": "2022-04-15",
"dueDate": "2022-05-06",
"forensicTriage": "No",
"knownRansomwareCampaignUse": "Unknown",
"notes": "https://nvd.nist.gov/vuln/detail/CVE-2019-3929",
"product": "Multiple Products",
"requiredAction": "Apply updates per vendor instructions.",
"shortDescription": "Multiple Crestron products are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root.",
"vendorProject": "Crestron",
"vulnerabilityName": "Crestron Multiple Products Command Injection Vulnerability"
},
"epss": {
"cve": "CVE-2019-3929",
"date": "2026-09-20",
"epss": "0.98952",
"percentile": "0.99928"
},
"nvd": {
"cve": {
"cisaActionDue": "2022-05-06",
"cisaExploitAdd": "2022-04-15",
"cisaRequiredAction": "Apply updates per vendor instructions.",
"cisaVulnerabilityName": "Crestron Multiple Products Command Injection Vulnerability",
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:am-100_firmware:1.6.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "913135BE-8FB4-40BA-85D8-AD0F824493C3",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:am-100:-:*:*:*:*:*:*:*",
"matchCriteriaId": "081E2B1B-027D-4846-8C61-54CE2D668CD0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:crestron:am-101_firmware:2.7.0.2:*:*:*:*:*:*:*",
"matchCriteriaId": "6AC584E7-9159-48E8-B499-F5CA68663503",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:crestron:am-101:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D0AB0523-6EFF-4C78-A8BA-B2764DBB04D0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:barco:wepresent_wipg-1000p_firmware:2.3.0.10:*:*:*:*:*:*:*",
"matchCriteriaId": "4102ECBE-C362-4D67-A8B8-E0C796991A05",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:barco:wepresent_wipg-1000p:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4CA49409-DD7A-443C-9C64-F7FC02AD572F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:barco:wepresent_wipg-1600w_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "CC11E306-2039-4981-B0DE-F0E086E82A99",
"versionEndExcluding": "2.4.1.19",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:barco:wepresent_wipg-1600w:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E6EDF943-F79F-4729-A15C-BEDFDAC42EA3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:extron:sharelink_200_firmware:2.0.3.4:*:*:*:*:*:*:*",
"matchCriteriaId": "A2A958C1-D420-4686-B16A-9F894D9D546B",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:extron:sharelink_200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9052908E-4A0A-4462-9054-FF8B81BE61AD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:extron:sharelink_250_firmware:2.0.3.4:*:*:*:*:*:*:*",
"matchCriteriaId": "4452FE8E-2FF1-4920-BE15-EDB36865E436",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:extron:sharelink_250:-:*:*:*:*:*:*:*",
"matchCriteriaId": "6D0429EC-69E4-40DF-8F58-92C14B1EE30F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:teqavit:wips710_firmware:1.1.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "30DE4653-931B-4EE4-997C-EDE3B4FD1103",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:teqavit:wips710:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C065DAA-CCAD-4551-A6D3-61A714EBEC2A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:sharp:pn-l703wa_firmware:1.4.2.3:*:*:*:*:*:*:*",
"matchCriteriaId": "1B378214-4F0E-4365-92B4-A1C1CA1BF8E9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:sharp:pn-l703wa:-:*:*:*:*:*:*:*",
"matchCriteriaId": "515FE3BB-C5C9-496C-A002-E5687D5D2B00",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:optoma:wps-pro_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "B85EAE85-7C54-4B93-96BA-72FCB1CFA94F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:optoma:wps-pro:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2033CAD9-390C-4AA4-A05E-951849AB16E8",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:blackbox:hd_wireless_presentation_system_firmware:1.0.0.5:*:*:*:*:*:*:*",
"matchCriteriaId": "2143F71D-47D5-4630-B1CF-74824682523C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:blackbox:hd_wireless_presentation_system:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E5722F58-47BA-4430-8F92-FA56348FD4A9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:infocus:liteshow3_firmware:1.0.16:*:*:*:*:*:*:*",
"matchCriteriaId": "A31899CB-CC41-446A-AB84-40D2BDED1F30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:infocus:liteshow3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7E81DF5B-9FD1-44E7-B23D-639ACAD4EED0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:infocus:liteshow4_firmware:2.0.0.7:*:*:*:*:*:*:*",
"matchCriteriaId": "D361E8D9-377E-4DBB-BFAC-35CB4333A6EB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:infocus:liteshow4:-:*:*:*:*:*:*:*",
"matchCriteriaId": "76B7C16D-C7D8-4502-B466-1D6A0183527A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
},
{
"lang": "es",
"value": "El firmware Crestron AM-100 versi\u00f3n 1.6.0.2, el firmware Crestron AM-101 versi\u00f3n 2.7.0.1, Barco wePresent WiPG-1000P firmware versi\u00f3n 2.3.0.10, Barco wePresent WiPG-1600W antes del firmware versi\u00f3n 2.4.1.19, Extron ShareLink 200/250 firmware versi\u00f3n 2.0.3.4, Teq AV IT WIPS710 firmware versi\u00f3n 1.1.0.7, SHARP PN-L703WA firmware versi\u00f3n 1.4.2.3, Optoma WPS-Pro firmware versi\u00f3n 1.0.0.5, Blackbox HD WPS firmware versi\u00f3n 1.0.0.5, InFocus LiteShow3 firmware versi\u00f3n 1.0.16 e InFocus LiteShow4 versi\u00f3n 2.0.0.7 son vulnerables para ordenar la inyecci\u00f3n por medio del endpoint HTTP file_transfer.cgi. Un atacante remoto no identificado puede usar esta vulnerabilidad para ejecutar comandos del sistema operativo como root."
}
],
"id": "CVE-2019-3929",
"lastModified": "2025-11-03T18:59:33.857",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 10.0,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2019-04-30T21:29:00.713",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"VDB Entry"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory",
"VDB Entry"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"tags": [
"US Government Resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "vulnreport@tenable.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
},
"vulnrichment": {
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T19:26:27.549Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB",
"x_transferred"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2019-3929",
"options": [
{
"Exploitation": "active"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-06T20:26:27.910638Z",
"version": "2.0.3"
},
"type": "ssvc"
}
},
{
"other": {
"content": {
"dateAdded": "2022-04-15",
"reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
},
"type": "kev"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-06T20:25:53.616Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"government-resource"
],
"url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2019-3929"
}
],
"timeline": [
{
"lang": "en",
"time": "2022-04-15T00:00:00.000Z",
"value": "CVE-2019-3929 added to CISA KEV"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"vendor": "Crestron",
"versions": [
{
"status": "affected",
"version": "Crestron AM-100 firmware 1.6.0.2"
},
{
"status": "affected",
"version": "Crestron AM-101 firmware 2.7.0.1"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"status": "affected",
"version": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"status": "affected",
"version": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"status": "affected",
"version": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"status": "affected",
"version": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"status": "affected",
"version": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"status": "affected",
"version": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"status": "affected",
"version": "InFocus LiteShow3 firmware 1.0.16"
},
{
"status": "affected",
"version": "and InFocus LiteShow4 2.0.0.7"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-14T17:06:03.000Z",
"orgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"shortName": "tenable"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"tags": [
"exploit",
"x_refsource_EXPLOIT-DB"
],
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vulnreport@tenable.com",
"ID": "CVE-2019-3929",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Crestron AirMedia, Barco WePresent, Extron ShareLink, Teq AV IT WIPS710, SHARP PN-L703WA, Optoma WPS-Pro, Blackbox HD WPS, InFocus LiteShow3, and InFocus LiteShow4.",
"version": {
"version_data": [
{
"version_value": "Crestron AM-100 firmware 1.6.0.2"
},
{
"version_value": "Crestron AM-101 firmware 2.7.0.1"
},
{
"version_value": "Barco wePresent WiPG-1000P firmware 2.3.0.10"
},
{
"version_value": "Barco wePresent WiPG-1600W before firmware 2.4.1.19"
},
{
"version_value": "Extron ShareLink 200/250 firmware 2.0.3.4"
},
{
"version_value": "Teq AV IT WIPS710 firmware 1.1.0.7"
},
{
"version_value": "SHARP PN-L703WA firmware 1.4.2.3"
},
{
"version_value": "Optoma WPS-Pro firmware 1.0.0.5"
},
{
"version_value": "Blackbox HD WPS firmware 1.0.0.5"
},
{
"version_value": "InFocus LiteShow3 firmware 1.0.16"
},
{
"version_value": "and InFocus LiteShow4 2.0.0.7"
}
]
}
}
]
},
"vendor_name": "Crestron"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The Crestron AM-100 firmware 1.6.0.2, Crestron AM-101 firmware 2.7.0.1, Barco wePresent WiPG-1000P firmware 2.3.0.10, Barco wePresent WiPG-1600W before firmware 2.4.1.19, Extron ShareLink 200/250 firmware 2.0.3.4, Teq AV IT WIPS710 firmware 1.1.0.7, SHARP PN-L703WA firmware 1.4.2.3, Optoma WPS-Pro firmware 1.0.0.5, Blackbox HD WPS firmware 1.0.0.5, InFocus LiteShow3 firmware 1.0.16, and InFocus LiteShow4 2.0.0.7 are vulnerable to command injection via the file_transfer.cgi HTTP endpoint. A remote, unauthenticated attacker can use this vulnerability to execute operating system commands as root."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 OS Command Injection"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2019-20",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2019-20"
},
{
"name": "46786",
"refsource": "EXPLOIT-DB",
"url": "https://www.exploit-db.com/exploits/46786/"
},
{
"name": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/152715/Barco-AWIND-OEM-Presentation-Platform-Unauthenticated-Remote-Command-Injection.html"
},
{
"name": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html",
"refsource": "MISC",
"url": "http://packetstormsecurity.com/files/155948/Barco-WePresent-file_transfer.cgi-Command-Injection.html"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "5ac1ecc2-367a-4d16-a0b2-35d495ddd0be",
"assignerShortName": "tenable",
"cveId": "CVE-2019-3929",
"datePublished": "2019-04-30T20:21:09.000Z",
"dateReserved": "2019-01-03T00:00:00.000Z",
"dateUpdated": "2025-10-21T23:45:38.287Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Browse all ATT&CK techniques and the vulnerabilities related to each.
Related by attack behaviour
Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.