GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

CVE-2019-20464 (GCVE-0-2019-20464)

Vulnerability from cvelistv5 – Published: 2021-04-02 15:32 – Updated: 2024-08-05 02:39
VLAI
Summary
An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a password, the other streaming services do not. By initiating communication on the RTSP port, an attacker can obtain access to the video feed without authenticating.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator · CISA-ADP (v2.0.3)
Decision recorded 2024-07-30 14:24 UTC
CWE
  • n/a
  • CWE-287 - Improper Authentication
Impacted products
Vendor Product Version CPE status
sannce smart_hd_wifi_security_camera_ean_2_950004_595317_firmware Affected: 0
    cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:*:*:*:*:*:*:*:*
Create a notification for this product.
Date Public
2021-03-30 00:00
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "smart_hd_wifi_security_camera_ean_2_950004_595317_firmware",
            "vendor": "sannce",
            "versions": [
              {
                "status": "affected",
                "version": "0"
              }
            ]
          }
        ],
        "metrics": [
          {
            "cvssV3_1": {
              "attackComplexity": "LOW",
              "attackVector": "NETWORK",
              "availabilityImpact": "NONE",
              "baseScore": 7.5,
              "baseSeverity": "HIGH",
              "confidentialityImpact": "HIGH",
              "integrityImpact": "NONE",
              "privilegesRequired": "NONE",
              "scope": "UNCHANGED",
              "userInteraction": "NONE",
              "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
              "version": "3.1"
            }
          },
          {
            "other": {
              "content": {
                "id": "CVE-2019-20464",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-30T14:24:26.869059Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "problemTypes": [
          {
            "descriptions": [
              {
                "cweId": "CWE-287",
                "description": "CWE-287 Improper Authentication",
                "lang": "en",
                "type": "CWE"
              }
            ]
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-30T14:28:13.491Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T02:39:10.022Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          },
          {
            "name": "20240729 Bunch of IoT CVEs",
            "tags": [
              "mailing-list",
              "x_transferred"
            ],
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "datePublic": "2021-03-30T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a password, the other streaming services do not. By initiating communication on the RTSP port, an attacker can obtain access to the video feed without authenticating."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "description": "n/a",
              "lang": "en",
              "type": "text"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-30T00:07:44.152Z",
        "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "shortName": "mitre"
      },
      "references": [
        {
          "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
        },
        {
          "name": "20240729 Bunch of IoT CVEs",
          "tags": [
            "mailing-list"
          ],
          "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
        }
      ]
    }
  },
  "cveMetadata": {
    "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
    "assignerShortName": "mitre",
    "cveId": "CVE-2019-20464",
    "datePublished": "2021-04-02T15:32:59.000Z",
    "dateReserved": "2020-02-17T00:00:00.000Z",
    "dateUpdated": "2024-08-05T02:39:10.022Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2019-20464",
      "date": "2026-09-20",
      "epss": "0.01668",
      "percentile": "0.75717"
    },
    "nvd": {
      "cve": {
        "configurations": [
          {
            "nodes": [
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "8123D4F3-B94B-405B-9FF5-0CA27A0B719E",
                    "vulnerable": true
                  }
                ],
                "negate": false,
                "operator": "OR"
              },
              {
                "cpeMatch": [
                  {
                    "criteria": "cpe:2.3:h:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317:-:*:*:*:*:*:*:*",
                    "matchCriteriaId": "548EDA0C-3BBF-44AF-99DC-73796B27874D",
                    "vulnerable": false
                  }
                ],
                "negate": false,
                "operator": "OR"
              }
            ],
            "operator": "AND"
          }
        ],
        "cveTags": [],
        "descriptions": [
          {
            "lang": "en",
            "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a password, the other streaming services do not. By initiating communication on the RTSP port, an attacker can obtain access to the video feed without authenticating."
          },
          {
            "lang": "es",
            "value": "Se detect\u00f3 un problema en los dispositivos Sannce Smart HD Wifi Security Camera EAN 2 950004 595317.\u0026#xa0;Por defecto, una aplicaci\u00f3n m\u00f3vil es usada para transmitir por medio de UDP.\u0026#xa0;Sin embargo, el dispositivo ofrece muchos m\u00e1s servicios que tambi\u00e9n permiten la transmisi\u00f3n.\u0026#xa0;Aunque el servicio usado por la aplicaci\u00f3n m\u00f3vil requiere una contrase\u00f1a, los otros servicios de transmisi\u00f3n no la requieren.\u0026#xa0;Al iniciar la comunicaci\u00f3n en el puerto RTSP, un atacante puede obtener acceso a la transmisi\u00f3n de video sin autenticaci\u00f3n."
          }
        ],
        "id": "CVE-2019-20464",
        "lastModified": "2024-11-21T04:38:32.650",
        "metrics": {
          "cvssMetricV2": [
            {
              "acInsufInfo": false,
              "baseSeverity": "MEDIUM",
              "cvssData": {
                "accessComplexity": "LOW",
                "accessVector": "NETWORK",
                "authentication": "NONE",
                "availabilityImpact": "NONE",
                "baseScore": 5.0,
                "confidentialityImpact": "PARTIAL",
                "integrityImpact": "NONE",
                "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
                "version": "2.0"
              },
              "exploitabilityScore": 10.0,
              "impactScore": 2.9,
              "obtainAllPrivilege": false,
              "obtainOtherPrivilege": false,
              "obtainUserPrivilege": false,
              "source": "nvd@nist.gov",
              "type": "Primary",
              "userInteractionRequired": false
            }
          ],
          "cvssMetricV31": [
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "nvd@nist.gov",
              "type": "Primary"
            },
            {
              "cvssData": {
                "attackComplexity": "LOW",
                "attackVector": "NETWORK",
                "availabilityImpact": "NONE",
                "baseScore": 7.5,
                "baseSeverity": "HIGH",
                "confidentialityImpact": "HIGH",
                "integrityImpact": "NONE",
                "privilegesRequired": "NONE",
                "scope": "UNCHANGED",
                "userInteraction": "NONE",
                "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                "version": "3.1"
              },
              "exploitabilityScore": 3.9,
              "impactScore": 3.6,
              "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "type": "Secondary"
            }
          ]
        },
        "published": "2021-04-02T16:15:13.053",
        "references": [
          {
            "source": "cve@mitre.org",
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          },
          {
            "source": "cve@mitre.org",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
          },
          {
            "source": "af854a3a-2127-422b-91ae-364da2661108",
            "tags": [
              "Exploit",
              "Third Party Advisory"
            ],
            "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
          }
        ],
        "sourceIdentifier": "cve@mitre.org",
        "vulnStatus": "Modified",
        "weaknesses": [
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "nvd@nist.gov",
            "type": "Primary"
          },
          {
            "description": [
              {
                "lang": "en",
                "value": "CWE-287"
              }
            ],
            "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
            "type": "Secondary"
          }
        ]
      }
    },
    "vulnrichment": {
      "containers": {
        "adp": [
          {
            "providerMetadata": {
              "dateUpdated": "2024-08-05T02:39:10.022Z",
              "orgId": "af854a3a-2127-422b-91ae-364da2661108",
              "shortName": "CVE"
            },
            "references": [
              {
                "tags": [
                  "x_transferred"
                ],
                "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
              },
              {
                "name": "20240729 Bunch of IoT CVEs",
                "tags": [
                  "mailing-list",
                  "x_transferred"
                ],
                "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
              }
            ],
            "title": "CVE Program Container"
          },
          {
            "affected": [
              {
                "cpes": [
                  "cpe:2.3:o:sannce:smart_hd_wifi_security_camera_ean_2_950004_595317_firmware:*:*:*:*:*:*:*:*"
                ],
                "defaultStatus": "unknown",
                "product": "smart_hd_wifi_security_camera_ean_2_950004_595317_firmware",
                "vendor": "sannce",
                "versions": [
                  {
                    "status": "affected",
                    "version": "0"
                  }
                ]
              }
            ],
            "metrics": [
              {
                "cvssV3_1": {
                  "attackComplexity": "LOW",
                  "attackVector": "NETWORK",
                  "availabilityImpact": "NONE",
                  "baseScore": 7.5,
                  "baseSeverity": "HIGH",
                  "confidentialityImpact": "HIGH",
                  "integrityImpact": "NONE",
                  "privilegesRequired": "NONE",
                  "scope": "UNCHANGED",
                  "userInteraction": "NONE",
                  "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
                  "version": "3.1"
                }
              },
              {
                "other": {
                  "content": {
                    "id": "CVE-2019-20464",
                    "options": [
                      {
                        "Exploitation": "none"
                      },
                      {
                        "Automatable": "yes"
                      },
                      {
                        "Technical Impact": "partial"
                      }
                    ],
                    "role": "CISA Coordinator",
                    "timestamp": "2024-07-30T14:24:26.869059Z",
                    "version": "2.0.3"
                  },
                  "type": "ssvc"
                }
              }
            ],
            "problemTypes": [
              {
                "descriptions": [
                  {
                    "cweId": "CWE-287",
                    "description": "CWE-287 Improper Authentication",
                    "lang": "en",
                    "type": "CWE"
                  }
                ]
              }
            ],
            "providerMetadata": {
              "dateUpdated": "2024-07-30T14:25:03.456Z",
              "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
              "shortName": "CISA-ADP"
            },
            "title": "CISA ADP Vulnrichment"
          }
        ],
        "cna": {
          "affected": [
            {
              "product": "n/a",
              "vendor": "n/a",
              "versions": [
                {
                  "status": "affected",
                  "version": "n/a"
                }
              ]
            }
          ],
          "datePublic": "2021-03-30T00:00:00.000Z",
          "descriptions": [
            {
              "lang": "en",
              "value": "An issue was discovered on Sannce Smart HD Wifi Security Camera EAN 2 950004 595317 devices. By default, a mobile application is used to stream over UDP. However, the device offers many more services that also enable streaming. Although the service used by the mobile application requires a password, the other streaming services do not. By initiating communication on the RTSP port, an attacker can obtain access to the video feed without authenticating."
            }
          ],
          "problemTypes": [
            {
              "descriptions": [
                {
                  "description": "n/a",
                  "lang": "en",
                  "type": "text"
                }
              ]
            }
          ],
          "providerMetadata": {
            "dateUpdated": "2024-07-30T00:07:44.152Z",
            "orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
            "shortName": "mitre"
          },
          "references": [
            {
              "url": "https://www.eurofins-cybersecurity.com/news/connected-devices-baby-monitors-part-2/"
            },
            {
              "name": "20240729 Bunch of IoT CVEs",
              "tags": [
                "mailing-list"
              ],
              "url": "http://seclists.org/fulldisclosure/2024/Jul/14"
            }
          ]
        }
      },
      "cveMetadata": {
        "assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
        "assignerShortName": "mitre",
        "cveId": "CVE-2019-20464",
        "datePublished": "2021-04-02T15:32:59.000Z",
        "dateReserved": "2020-02-17T00:00:00.000Z",
        "dateUpdated": "2024-08-05T02:39:10.022Z",
        "state": "PUBLISHED"
      },
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…